Download

4W DC-DC Converter P4D-Series
●
●
●
●
Wide 2:1 input range
Up to 3500 VDC isolation
Continuous short circuit protection
24 Pin Standard Package
Model selection guide
Typ
Input voltage range
[VDC]
Output voltage
[VDC]
Output current
[mA]
Efficiency typ.
[%]
Single output
P4D1205S
9...18
5.0
800
P4D1209S
9...18
9.0
445
P4D1212S
9...18
12.0
333
P4D1215S
9...18
15.0
267
P4D1224S
9...18
24.0
167
P4D2405S
18...36
5.0
800
P4D2409S
18...36
9.0
445
P4D2412S
18...36
12.0
333
P4D2415S
18...36
15.0
267
P4D2424S
18...36
24.0
167
P4D4805S
36...72
5.0
800
P4D4809S
36...72
9.0
445
P4D4812S
36...72
12.0
333
P4D4815S
36...72
15.0
267
P4D4824S
36...72
24.0
167
Dual output
P4D1205D
9...18
±5.0
±400
P4D1209D
9...18
±9.0
±223
P4D1212D
9...18
±12.0
±167
P4D1215D
9...18
±15.0
±134
P4D1224D
9...18
±24.0
±84
P4D2405D
18...36
±5.0
±400
P4D2409D
18...36
±9.0
±223
P4D2412D
18...36
±12.0
±167
P4D2415D
18...36
±15.0
±134
P4D2424D
18...36
±24.0
±84
P4D4805D
36...72
±5.0
±400
P4D4809D
36...72
±9.0
±223
P4D4812D
36...72
±12.0
±167
P4D4815D
36...72
±15.0
±134
P4D4824D
36...72
±24.0
±84
Input voltage range reach from 9V to 72V and the output voltage range reach from 3.3V to 24V
Suffix: “H” for 3.5kV isolation voltage
77
80
80
80
80
79
82
82
82
82
78
82
82
82
82
77
80
80
80
80
79
82
82
82
82
76
82
82
82
82
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
4W DC-DC Converter P4D-Series
Specifications
Input
Voltage range
Filter
Isolation:
Rated voltage
Resistance
Capacitance
Output
Voltage accuracy
Voltage balance
(dual outputs)
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
General
Efficiency
Switching frequency
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
12 VDC, 9…18 VDC
24 VDC, 18…36 VDC
48 VDC, 36…72 VDC
Pi Network
1500 VDC, Standard
3500 VDC, Suffix “H”
109 Ω
390 pF, typ.
77% to 82%
100 kHz…400 kHz
-40 °C to +85 °C
100 °C max.
-40 °C to +125 °C
None required
Up to 90%,
non-condensing
Free-air convection
Cooling
Physical
Dimensions
Weight
± 1%, max.
± 1%
60 mVp-p, max.
31.75 x 20.32 x 10.16 mm
16.3 g metal, suffix “M”,
14.5 g plastic standard
Continuous
Automatic
± 0.5%, max.
± 0.5%, max.
± 0.02% / °C
Dimensions
27.94
31.75
0.5
P4D1205D
PHI-CON
bottom view
20.32
All dimensions in mm
Tolerance ±0.25 mm
0.5
15.24
2.54
Pin connections
Pin
1
2
3
9
10
11
12
13
14
15
16
22
23
24
Standard
Single
Dual
+V Input
+V Input
N.C.
-V Output
N.C.
Common
Omitted
Omitted
-V Output
Common
+V Output
+V Output
-V Input
-V Input
-V Input
-V Input
+V Output
+V Output
-V Output
Common
Omitted
Omitted
N.C.
Common
N.C.
-V Output
+V Input
+V Input
3.5 kVDC
Single
Dual
Omitted
Omitted
-V Input
-V Input
-V Input
-V Input
Omitted
Common
Omitted
Omitted
N.C.
-V Output
Omitted
Omitted
Omitted
Omitted
+V Output
+V Output
Omitted
Omitted
-V Output
Common
+V Input
+V Input
+V Input
+V Input
Omitted
Omitted
10.16
3.05 min.
Life Support Policy: HY-LINE does not authorize
the use of any of its products for use in life support
devices or systems without the express written
approval of an officer of the Company. Life support
systems are devices which support or sustain life,
and whose failure to perform, when properly used
in accordance with instructions for use provided in
the labeling, can be reasonably expected to result
in significant injury to the user. Rev: 11.10 f
Page 2 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
Similar pages