Download

5W DC-DC Converter P5B-Series
●
●
●
●
Wide 2:1 input range
Up to 3500 VDC isolation
MTBF >1.121 MHours
Continuous short circuit protection
Model selection guide
Typ
Input nominal
voltage
[VDC]
Single output
P5B123R3S
9...18
P5B1205S
9...18
P5B1209S
9...18
P5B1212S
9...18
P5B1215S
9...18
P5B1224S
9...18
P5B243R3S
18...36
P5B2405S
18...36
P5B2409S
18...36
P5B2412S
18...36
P5B2415S
18...36
P5B2424S
18...36
P5B483R3S
36...72
P5B4805S
36...72
P5B4809S
36...72
P5B4812S
36...72
P5B4815S
36...72
P5B4824S
36...72
Dual output
P5B123R3D
9...18
P5B1205D
9...18
P5B1209D
9...18
P5B1212D
9...18
P5B1215D
9...18
P5B1224D
9...18
P5B243R3D
18...36
P5B2405D
18...36
P5B2409D
18...36
P5B2412D
18...36
P5B2415D
18...36
P5B2424D
18...36
P5B483R3D
36...72
P5B4805D
36...72
P5B4809D
36...72
P5B4812D
36...72
P5B4815D
36...72
P5B4824D
36...72
Suffix: “H” for 3.5kV isolation voltage
Output voltage
Output current
Efficiency typ.
[VDC]
[mA]
[%]
Capacitor load
max.
[mA]
3.3
5.0
9.0
12.0
15.0
24.0
3.3
5.0
9.0
12.0
15.0
24.0
3.3
5.0
9.0
12.0
15.0
24.0
1300
1000
556
417
333
209
1300
1000
556
417
333
209
1300
1000
556
417
333
209
73
77
78
81
80
80
75
80
82
80
82
82
75
80
82
80
83
83
1000
1000
680
330
220
68
1000
1000
680
330
220
68
1000
1000
680
330
220
68
±3.3
±5.0
±9.0
±12.0
±15.0
±24.0
±3.3
±5.0
±9.0
±12.0
±15.0
±24.0
±3.3
±5.0
±9.0
±12.0
±15.0
±24.0
±750
±500
±278
±208
±167
±105
±750
±500
±278
±208
±167
±105
±750
±500
±278
±208
±167
±105
73
77
80
80
79
80
75
78
83
80
80
80
73
79
79
80
80
80
2 x 680
2 x 330
2 x 220
2 x 100
2 x 47
2 x 33
2 x 680
2 x 330
2 x 220
2 x 100
2 x 47
2 x 33
2 x 680
2 x 330
2 x 220
2 x 100
2 x 47
2 x 33
Page 1 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
5W DC-DC Converter P5B-Series
Specifications
Input
no load current
Filter
Isolation:
Rated voltage (3 sec.,
input to output)
Resistance
Capacitance
Output
Voltage accuracy
Voltage balance
(dual outputs)
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Current limiting
Line voltage regulation
Load voltage regulation
Temperature coefficient
12 V series 30 mADC, typ.
24 V series 20 mADC, typ.
48 V series 12 mADC, typ.
Pi Network
1500 VDC, Standard
3500 VDC, Suffix “H”
109 Ω
470 pF, typ.
± 1%
± 1%
60 mVp-p, max.
Continuous (automatic restart)
120% of full load
± 0.5%, ±[email protected] type
± 0.5%, max.
± 0.02% / °C
General
Efficiency
Switching frequency
Safety in accordance with
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
Cooling
Physical
Dimensions
Weight
Base material
Case material
Lead soldering
Temperature
73% to 83%
265 kHz, typ.
IEC60950-1:2001
-40 °C to +85 °C
100 °C max.
-40 °C to +125 °C
None required
Up to 95%,
non-condensing
Free-air convection
31.75x20.32x10.16 mm
17 g metal, standard
Epoxy (UL94-V-0 rated)
Standard, nickel-coated
copper metal
260°C for 10 s, distance
from package 1.5 mm
Page 2 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
5W DC-DC Converter P5B-Series
Dimensions
27.94
31.75
0.5
P5B2405S
PHI-CON
1
12
15.24
bottom view
20.32
24
All dimensions in mm
Tolerance ±0.25 mm
0.5
13
2.54
10.16
3.05 min.
Pin connections
Pin
1
2
3
9
10
11
12
13
14
15
16
22
23
24
Standard
Single
Dual
+V Input
+V Input
N.C.
-V Output
N.C.
Common
Omitted
Omitted
-V Output
Common
+V Output
+V Output
-V Input
-V Input
-V Input
-V Input
+V Output
+V Output
-V Output
Common
Omitted
Omitted
N.C.
Common
N.C.
-V Output
+V Input
+V Input
3.5 kVDC
Single
Dual
Omitted
Omitted
-V Input
-V Input
-V Input
-V Input
Omitted
Common
Omitted
Omitted
N.C.
-V Output
Omitted
Omitted
Omitted
Omitted
+V Output
+V Output
Omitted
Omitted
-V Output
Common
+V Input
+V Input
+V Input
+V Input
Omitted
Omitted
Life Support Policy: HY-LINE does not
authorize the use of any of its products
for use in life support devices or systems
without the express written approval of
an officer of the Company. Life support
systems are devices which support or
sustain life, and whose failure to perform,
when properly used in accordance with
instructions for use provided in the
labeling, can be reasonably expected to
result in significant injury to the user.
Rev: 7.08 f
Page 3 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz: