5W DC-DC Converter P5D-Series
●
●
●
●
Wide 2:1 input range
Up to 3500 VDC isolation
Continuous short circuit protection
MTBF 1.12 M hours
Model selection guide
Typ
Input voltage
range
Input
quiescent
current
[mA]
Output voltage
Output current
Efficiency typ.
[VDC]
[VDC]
[mA]
[%]
Single output
P5D123R3S
9...18
20
3.3
1300
73
P5D1205S
9...18
20
5.0
1000
75
P5D1209S
9...18
20
9.0
555
78
P5D1212S
9...18
20
12.0
417
81
P5D1215S
9...18
20
15.0
333
80
P5D1224S
9...18
20
24.0
208
80
P5D243R3S
18...36
15
3.3
1300
75
P5D2405S
18...36
15
5.0
1000
78
P5D2409S
18...36
15
9.0
555
80
P5D2412S
18...36
15
12.0
417
82
P5D2415S
18...36
15
15.0
333
82
P5D2424S
18...36
15
24.0
208
82
P5D483R3S
36...72
8
3.3
1300
73
P5D4805S
36...72
8
5.0
1000
77
P5D4809S
36...72
8
9.0
555
79
P5D4812S
36...72
8
12.0
417
80
P5D4815S
36...72
8
15.0
333
80
P5D4824S
36...72
8
24.0
208
80
Dual output
P5D123R3D
9...18
20
±3.3
±750
73
P5D1205D
9...18
20
±5.0
±500
77
P5D1209D
9...18
20
±9.0
±278
80
P5D1212D
9...18
20
±12.0
±208
80
P5D1215D
9...18
20
±15.0
±167
79
P5D1224D
9...18
20
±24.0
±104
80
P5D243R3D
18...36
15
±3.3
±750
75
P5D2405D
18...36
15
±5.0
±500
78
P5D2409D
18...36
15
±9.0
±278
80
P5D2412D
18...36
15
±12.0
±208
80
P5D2415D
18...36
15
±15.0
±167
80
P5D2424D
18...36
15
±24.0
±104
80
P5D483R3D
36...72
8
±3.3
±750
73
P5D4805D
36...72
8
±5.0
±500
79
P5D4809D
36...72
8
±9.0
±278
79
P5D4812D
36...72
8
±12.0
±208
80
P5D4815D
36...72
8
±15.0
±167
80
P5D4824D
36...72
8
±24.0
±104
80
Input voltage range reach from 9V to 72V and the output voltage range reach from 3.3V to 24V
Suffix: “H” for 3.5kV isolation voltage
Capacitive
Load
[µF]
1000
1000
680
330
220
68
1000
1000
680
330
220
68
1000
1000
680
330
220
68
2 x 680
2 x 330
2 x 220
2 x 100
2 x 47
2 x 33
2 x 680
2 x 330
2 x 220
2 x 100
2 x 47
2 x 33
2 x 680
2 x 330
2 x 220
2 x 100
2 x 47
2 x 33
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
5W DC-DC Converter P5D-Series
Specifications
Input
Voltage range
Filter
Isolation:
Rated voltage
Resistance
Capacitance
Output
Voltage accuracy
Voltage balance
(dual outputs)
Ripple and noise
(at 20 MHz BW)
Over current protection
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
12 VDC, 9…18 VDC
24 VDC, 18…36 VDC
48 VDC, 36…72 VDC
Pi Network
General
Efficiency
Switching frequency
Safety Standard in
accordance with
Environmental
Operating temperature
(ambient)
Case temperature
Storage temperature
Derating
Humidity
1500 VDC, Standard
3500 VDC, Suffix “H”
109 Ω
470 pF, typ.
± 1%
± 1%
Cooling
Physical
Potting Material
Dimensions
Weight
Soldering temperature
1.5mm distance from case
60 mVp-p, max.
120% of max. Iout
Continuous
Automatic
± 0.5%, max.
± 0.5%, max.
± 0.02% / °C
73% to 82%
100 kHz…400 kHz
IEC 60950-1:2001
-40 °C to +71 °C
100 °C max.
-40 °C to +125 °C
None required
Up to 95%,
non-condensing
Free-air convection
Epoxy (UL94V-0 rated)
31.75 x 20.32 x 10.16 mm
17 g
260°C for 10 s
Dimensions
27.94
31.75
0.5
P5D1205D
PHI-CON
bottom view
20.32
All dimensions in mm
Tolerance ±0.25 mm
0.5
15.24
2.54
Pin connections
Pin
1
2
3
9
10
11
12
13
14
15
16
22
23
24
Standard
Single
Dual
+V Input
+V Input
N.C.
-V Output
N.C.
Common
Omitted
Omitted
-V Output
Common
+V Output
+V Output
-V Input
-V Input
-V Input
-V Input
+V Output
+V Output
-V Output
Common
Omitted
Omitted
N.C.
Common
N.C.
-V Output
+V Input
+V Input
3.5 kVDC
Single
Dual
Omitted
Omitted
-V Input
-V Input
-V Input
-V Input
Omitted
Common
Omitted
Omitted
N.C.
-V Output
Omitted
Omitted
Omitted
Omitted
+V Output
+V Output
Omitted
Omitted
-V Output
Common
+V Input
+V Input
+V Input
+V Input
Omitted
Omitted
10.16
3.05 min.
Life Support Policy: HY-LINE does not authorize
the use of any of its products for use in life support
devices or systems without the express written
approval of an officer of the Company. Life support
systems are devices which support or sustain life,
and whose failure to perform, when properly used
in accordance with instructions for use provided in
the labeling, can be reasonably expected to result
in significant injury to the user. Rev: 04.07 f
Page 2 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
Similar pages