Download

5W DC-DC Converter P5U-Series
●
●
●
●
●
Wide 2:1input range
Up to 3500 VDC isolation
Continuous short circuit protection
24 Pin DIL Package
Regulated
Model selection guide
Typ
Single output
P5U1205S
P5U1209S
P5U1212S
P5U1215S
P5U1224S
P5U2405S
P5U2409S
P5U2412S
P5U2415S
P5U2424S
P5U4805S
P5U4809S
P5U4812S
P5U4815S
P5U4824S
Dual output
P5U1205D
P5U1209D
P5U1212D
P5U1215D
P5U1224D
P5U2405D
P5U2409D
P5U2412D
P5U2415D
P5U2424D
P5U4805D
P5U4809D
P5U4812D
P5U4815D
P5U4824D
Input voltage range
[VDC]
Output voltage
[VDC]
Output current
[mA]
Efficiency typ.
[%]
9...18
9...18
9...18
9...18
9...18
18...36
18...36
18...36
18...36
18...36
36...72
36...72
36...72
36...72
36...72
5.0
9.0
12.0
15.0
24.0
5.0
9.0
12.0
15.0
24.0
5.0
9.0
12.0
15.0
24.0
1000
560
420
330
210
1000
560
420
330
210
1000
560
420
330
210
77
80
80
80
80
78
82
82
82
82
80
82
82
82
82
9...18
9...18
9...18
9...18
9...18
18...36
18...36
18...36
18...36
18...36
36...72
36...72
36...72
36...72
36...72
±5.0
±9.0
±12.0
±15.0
±24.0
±5.0
±9.0
±12.0
±15.0
±24.0
±5.0
±9.0
±12.0
±15.0
±24.0
±500
±280
±210
±170
±105
±500
±280
±210
±170
±105
±500
±280
±210
±170
±105
77
80
80
80
80
78
82
82
82
82
80
82
82
80
80
Input voltage range reach from 9V to 72V and the output voltage range reach from 3.3V to 24V
Suffix: “H” for 3.5kV isolation voltage
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
5W DC-DC Converter P5U-Series
Specifications
Input
Voltage range
General
Efficiency
Switching frequency
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
12 VDC, 9…18 VDC
24 VDC, 18…36 VDC
48 VDC, 36…72 VDC
Pi Network
Filter
Isolation:
Rated voltage
Resistance
Capacitance
Output
Voltage accuracy
Voltage balance
(dual outputs)
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
1500 VDC, Standard
3500 VDC, Suffix “H”
109 Ω
390 pF, typ.
Cooling
Physical
Dimensions
Weight
± 1%, max.
± 1%
60 mVp-p, max.
77% to 82%
100…400 kHz, typ.
-40 °C to +85 °C
100 °C max.
-40 °C to +125 °C
None required
Up to 90%,
non-condensing
Free-air convection
31.75 x 20.32 x 10.16 mm
15 g
Continuous
Automatic
± 0.5%, max.
± 0.5%, max.
± 0.02% / °C
Dimensions
27.94
31.75
0.5
P5U2405S
PHI-CON
1
12
15.24
bottom view
20.32
24
All dimensions in mm
Tolerance ±0.25 mm
0.5
13
2.54
Pin connections
Pin
1
2
3
9
10
11
12
13
14
15
16
22
23
24
Standard
Single
Dual
Omitted
Omitted
-V Input
-V Input
-V Input
-V Input
Omitted
Common
Omitted
Omitted
N.C.
-V Output
Omitted
Omitted
Omitted
Omitted
+V Output
+V Output
Omitted
Omitted
-V Output
Common
+V Input
+V Input
+V Input
+V Input
Omitted
Omitted
3.5 kVDC
Single
Dual
Omitted
Omitted
-V Input
-V Input
-V Input
-V Input
Omitted
Common
Omitted
Omitted
N.C.
-V Output
Omitted
Omitted
Omitted
Omitted
+V Output
+V Output
Omitted
Omitted
-V Output
Common
+V Input
+V Input
+V Input
+V Input
Omitted
Omitted
10.16
3.05 min.
Life Support Policy: HY-LINE does not authorize
the use of any of its products for use in life support
devices or systems without the express written
approval of an officer of the Company. Life support
systems are devices which support or sustain life,
and whose failure to perform, when properly used
in accordance with instructions for use provided in
the labeling, can be reasonably expected to result
in significant injury to the user. Rev: 09.06f
Page 2 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
Similar pages