6W DC-DC Converter P6E-Series ● ● ● ● ● SIL 8 Pin Wide input range 2:1 Up to 3000 VDC isolation Continuous short circuit protection Remote control input Model guide Type Single output P6E053R3SC P6E0505SC P6E0509SC P6E0512SC P6E0515SC P6E0524SC P6E123R3SC P6E1205SC P6E1209SC P6E1212SC P6E1215SC P6E1224SC P6E243R3SC P6E2405SC P6E2409SC P6E2412SC P6E2415SC P6E2424SC P6E483R3SC P6E4805SC P6E4809SC P6E4812SC P6E4815SC P6E4824SC Dual output P6E0505DC P6E0512DC P6E0515DC P6E1205DC P6E1212DC P6E1215DC P6E2405DC P6E2412DC P6E2415DC P6E4805DC P6E4812DC P6E4815DC Input voltage range [VDC] Input current no load [mA] Input current full load [mA] 4.5…9 4.5…9 4.5…9 4.5…9 4.5…9 4.5…9 9…18 9…18 9…18 9…18 9…18 9…18 18…36 18…36 18…36 18…36 18…36 18…36 36...72 36...72 36...72 36...72 36...72 36...72 105 105 105 105 105 105 55 55 55 55 55 55 30 30 30 30 30 30 15 15 15 15 15 15 1145 1520 1445 1430 1430 1430 470 600 595 590 590 580 230 300 295 295 290 290 115 155 145 150 145 150 4.5…9 4.5…9 4.5…9 9…18 9…18 9…18 18…36 18…36 18…36 36...72 36...72 36...72 105 105 105 55 55 55 30 30 30 15 15 15 1480 1430 1430 610 595 580 305 300 300 150 145 145 Part number structure Output power Series P6 E 6 Watt Input voltage 05 05 4.5..9 V 12 9..18 V 24 18..36 V 48 36..72 V Output voltage [VDC] Output current min. [mA] Output current max. [mA] Efficiency typ. @ full load [%] Capacitive load max. (note3) [µF] 3.3 5.0 9.0 12.0 15.0 24.0 3.3 5.0 9.0 12.0 15.0 24.0 3.3 5.0 9.0 12.0 15.0 24.0 3.3 5.0 9.0 12.0 15.0 24.0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1300 1200 667 500 400 250 1300 1200 667 500 400 250 1300 1200 667 500 400 250 1300 1200 667 500 400 250 75 79 83 84 84 84 76 83 84 85 85 86 78 83 85 85 87 87 76 80 85 84 86 84 6600 3300 2000 1600 1400 680 6600 3300 2000 1600 1400 680 6600 3300 2000 1600 1400 680 6600 3300 2000 1600 1400 680 ±5.0 ±12.0 ±15.0 ±5.0 ±12.0 ±15.0 ±5.0 ±12.0 ±15.0 ±5.0 ±12.0 ±15.0 0 0 0 0 0 0 0 0 0 0 0 0 ±600 ±250 ±200 ±600 ±250 ±200 ±600 ±250 ±200 ±600 ±250 ±200 81 84 84 82 84 86 82 84 84 82 85 85 2 x 2000 2 x 900 2 x 660 2 x 2000 2 x 900 2 x 660 2 x 2000 2 x 900 2 x 660 2 x 2000 2 x 900 2 x 660 Output voltage 3R3 3R3 3.3 V 05 5V 09 9V 12 12 V 15 15 V 24 24 V Outputs S S single D dual Isolation H Blank 1 kV H 3 kV Remote control C C control Input Blank without remote control function Page 1 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 6W DC-DC Converter P6E-Series Specifications Input Absolute max. voltage for 100 ms Input reflected ripple current Filter On / off controll pin Standby current consumption Isolation: Rated voltage for 60 s, input / output (Tested for 3 s) Resistance Capacitance Output Voltage accuracy Ripple and noise (at 20 MHz BW) Short circuit protection Short circuit restart Start up time Line voltage regulation Load regulation Dual output cross regulation Temperature coefficient Transient recovery time Transient response deviation (see note 4) P6E05xxxx –0.7..15 VDC P6E12xxxx – 0.7..36 VDC P6E24xxxx – 0.7..50 VDC P6E48xxxx – 0.7..100 VDC 30 mApp, typ. (see note 5 & figure 2) Capacitors on: open off: -2...-4 mA control current (via series resistor 1 kΩ, see figure 3) 2.5 mA typ. 1500 VDC 3000 VDC (Suffix “H”) 9 10 Ω, min. 50 pF, typ. ±1% 75 mVpp, max. (see note 2 & figure 1) Continuous Automatic 30 ms, typ. ± 0.2 % ±1% (at 0…100 % load change) ± 5 % (note 1) ± 0.02 % / °C 500 µs, typ. (see note 4) ± 3 %, max. P6Exx3R3xx ± 5 %, max. P6Exx05xx ± 5 %, max. General Switching frequency Safety standard in accordance with EMC specifications Conducted emissions Radiated emissions ESD RS EFT (see note 9) Surge (see note 9) CS PFMF General Switching frequency Safety standard in accordance with Environmental Operating temperature (ambient) Case temperature Storage temperature Derating Humidity 100...650 kHz IEC60950 EN55022 class A EN55022 class A IEC61000-4-2 perf. criteria A IEC61000-4-3 perf. criteria A IEC61000-4-4 perf. criteria A IEC61000-4-5 perf. criteria A IEC61000-4-6 perf. criteria A IEC61000-4-8 perf. criteria A 100 kHz, min. IEC60950 -40 °C to 65 °C 105 °C, max. -55 °C ... +125 °C See SOA curve Up to 95 %, non-condensing Cooling (see note 6) Physical Dimensions SIP8 Weight Case material standard version Potting material Pin soldering temperature 21.85 x 9.2 x 11,1 mm 4.8 g non-conductive black plastic, UL94-V0 Epoxy (UL94-V0 rated) 260 C° for 10 s, 1.5 mm distance from body Notes: 1. One output is 25 % to 100 % burdened, the other output is 100 % burdened. The output voltage deviation can be ± 5 %. 2. Measured with a 1 µF ceramic capacitor. (see Figure 1) 3. Test by minimal Vin and constant resistive load. 4. Test by nominal Vin and 100 % to 25 % load at 25 % load step change. 5. Measured input reflected ripple current with a simulated source inductance of 12 µH and source capacitance of 47 µF, ESR <1 Ω at 100 kHz. (see Figure 2) 6. Natural air convection is usually about 30…65 LFM but is not equal to still air. 7. Exceeding the absolute ratings of the converter could cause damage. It is not allowed for continuous operatin ratings. 8. Input filter components are be required to help meet conducted emission class A, which application refer to the EMI filter of design and feature configuration. 9. An external filter capacitor is required if the module has to meet IEC61000-4-4 and IEC61000-4-5. Suggested is a value of 330 µF / 100 V of Nippon Chemicon’s KY-Series. 10. All specifications are typical at 25 °C, nominal input voltage and full load unless otherwise noted. Application circuit IEC61000-4-4 and IEC61000-4-5, see note 9 + Vin Nippon Chemicon KY – Series 330 µF / 100 V + Load - Vin Page 2 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 6W DC-DC Converter P6E-Series Output ripple & noise measurement test method (Figure 1) Use the following measurement circuit. The oscilloscope mesurement bandwidth must be > 20 MHz. +Vou Resistive load Cout 1 µF DC/DC-Converter Measure points for oscilloscope -Vout Input reflected ripple current measure circuit (Figure 2) Input reflected current is measured through a source inductor and a source capacitor at nominal input voltage and full load. Oscilloscope current probe + Vin 12 µH Measure point 47 µF ESR <1Ω at 100 kHz Load - Vin Remote control function (Figure 3) + Vin 2 “On” state at open remote control input Rem.-Ctrl-Input 1k 3 - Vin “Off” state at remote control current -2…-4 mA 1 6 + Vout 7 - Vout EMI Filter The filter components are used to help meet conducted emissions requirement for the module. These components should be closed mounted as possible to the module. All leads should be minimized to decrease radiated noise. L CY + Vin Cin Load CX CX - Vin CY Type P6E05xxxx P6E12xxxx P6E24xxxx P6E48xxxx Cin 330 µF - CX 22 µF Ceramic 10 µF Ceramic 10 µF Ceramic 2.2 µF Ceramic CY 220 pF / 3 kV 220 pF / 3 kV 220 pF / 3 kV 220 pF / 3 kV L 10 µH 10 µH 10 µH 10 µH Page 3 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 6W DC-DC Converter P6E-Series Dimensions Pin connections Pin 1 2 3 5 6 7 8 Single -V Input +V Input Omitted Omitted +V Output -V Output N.C. Single with RC -V Input +V Input Remote contr. on/off N.C. +V Output -V Output N.C. Dual -V Input +V Input N.C. N.C. +V Output Common -V Output Dual with RC -V Input +V Input Remote contr. on/off N.C. +V Output Common -V Output PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 02.15 f Page 4 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]