6W DC-DC Converter P6E-Series
●
●
●
●
●
SIL 8 Pin
Wide input range 2:1
Up to 3000 VDC isolation
Continuous short circuit protection
Remote control input
Model guide
Type
Single output
P6E053R3SC
P6E0505SC
P6E0509SC
P6E0512SC
P6E0515SC
P6E0524SC
P6E123R3SC
P6E1205SC
P6E1209SC
P6E1212SC
P6E1215SC
P6E1224SC
P6E243R3SC
P6E2405SC
P6E2409SC
P6E2412SC
P6E2415SC
P6E2424SC
P6E483R3SC
P6E4805SC
P6E4809SC
P6E4812SC
P6E4815SC
P6E4824SC
Dual output
P6E0505DC
P6E0512DC
P6E0515DC
P6E1205DC
P6E1212DC
P6E1215DC
P6E2405DC
P6E2412DC
P6E2415DC
P6E4805DC
P6E4812DC
P6E4815DC
Input voltage
range
[VDC]
Input current
no load
[mA]
Input current
full load
[mA]
4.5…9
4.5…9
4.5…9
4.5…9
4.5…9
4.5…9
9…18
9…18
9…18
9…18
9…18
9…18
18…36
18…36
18…36
18…36
18…36
18…36
36...72
36...72
36...72
36...72
36...72
36...72
105
105
105
105
105
105
55
55
55
55
55
55
30
30
30
30
30
30
15
15
15
15
15
15
1145
1520
1445
1430
1430
1430
470
600
595
590
590
580
230
300
295
295
290
290
115
155
145
150
145
150
4.5…9
4.5…9
4.5…9
9…18
9…18
9…18
18…36
18…36
18…36
36...72
36...72
36...72
105
105
105
55
55
55
30
30
30
15
15
15
1480
1430
1430
610
595
580
305
300
300
150
145
145
Part number structure
Output power
Series
P6
E
6 Watt
Input voltage
05
05
4.5..9 V
12
9..18 V
24
18..36 V
48
36..72 V
Output
voltage
[VDC]
Output
current min.
[mA]
Output
current max.
[mA]
Efficiency typ.
@ full load
[%]
Capacitive load
max. (note3)
[µF]
3.3
5.0
9.0
12.0
15.0
24.0
3.3
5.0
9.0
12.0
15.0
24.0
3.3
5.0
9.0
12.0
15.0
24.0
3.3
5.0
9.0
12.0
15.0
24.0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1300
1200
667
500
400
250
1300
1200
667
500
400
250
1300
1200
667
500
400
250
1300
1200
667
500
400
250
75
79
83
84
84
84
76
83
84
85
85
86
78
83
85
85
87
87
76
80
85
84
86
84
6600
3300
2000
1600
1400
680
6600
3300
2000
1600
1400
680
6600
3300
2000
1600
1400
680
6600
3300
2000
1600
1400
680
±5.0
±12.0
±15.0
±5.0
±12.0
±15.0
±5.0
±12.0
±15.0
±5.0
±12.0
±15.0
0
0
0
0
0
0
0
0
0
0
0
0
±600
±250
±200
±600
±250
±200
±600
±250
±200
±600
±250
±200
81
84
84
82
84
86
82
84
84
82
85
85
2 x 2000
2 x 900
2 x 660
2 x 2000
2 x 900
2 x 660
2 x 2000
2 x 900
2 x 660
2 x 2000
2 x 900
2 x 660
Output voltage
3R3
3R3
3.3 V
05
5V
09
9V
12
12 V
15
15 V
24
24 V
Outputs
S
S
single
D
dual
Isolation
H
Blank
1 kV
H
3 kV
Remote control
C
C
control
Input
Blank
without
remote
control
function
Page 1 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
6W DC-DC Converter P6E-Series
Specifications
Input
Absolute max. voltage for
100 ms
Input reflected ripple current
Filter
On / off controll pin
Standby current consumption
Isolation:
Rated voltage for 60 s, input /
output (Tested for 3 s)
Resistance
Capacitance
Output
Voltage accuracy
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Short circuit restart
Start up time
Line voltage regulation
Load regulation
Dual output cross regulation
Temperature coefficient
Transient recovery time
Transient response deviation
(see note 4)
P6E05xxxx –0.7..15 VDC
P6E12xxxx – 0.7..36 VDC
P6E24xxxx – 0.7..50 VDC
P6E48xxxx – 0.7..100 VDC
30 mApp, typ.
(see note 5 & figure 2)
Capacitors
on: open
off: -2...-4 mA control current
(via series resistor 1 kΩ,
see figure 3)
2.5 mA typ.
1500 VDC
3000 VDC (Suffix “H”)
9
10 Ω, min.
50 pF, typ.
±1%
75 mVpp, max.
(see note 2 & figure 1)
Continuous
Automatic
30 ms, typ.
± 0.2 %
±1%
(at 0…100 % load change)
± 5 % (note 1)
± 0.02 % / °C
500 µs, typ. (see note 4)
± 3 %, max.
P6Exx3R3xx ± 5 %, max.
P6Exx05xx ± 5 %, max.
General
Switching frequency
Safety standard in
accordance with
EMC specifications
Conducted emissions
Radiated emissions
ESD
RS
EFT (see note 9)
Surge (see note 9)
CS
PFMF
General
Switching frequency
Safety standard in
accordance with
Environmental
Operating temperature
(ambient)
Case temperature
Storage temperature
Derating
Humidity
100...650 kHz
IEC60950
EN55022 class A
EN55022 class A
IEC61000-4-2 perf. criteria A
IEC61000-4-3 perf. criteria A
IEC61000-4-4 perf. criteria A
IEC61000-4-5 perf. criteria A
IEC61000-4-6 perf. criteria A
IEC61000-4-8 perf. criteria A
100 kHz, min.
IEC60950
-40 °C to 65 °C
105 °C, max.
-55 °C ... +125 °C
See SOA curve
Up to 95 %,
non-condensing
Cooling
(see note 6)
Physical
Dimensions SIP8
Weight
Case material standard
version
Potting material
Pin soldering temperature
21.85 x 9.2 x 11,1 mm
4.8 g
non-conductive black plastic,
UL94-V0
Epoxy (UL94-V0 rated)
260 C° for 10 s, 1.5 mm
distance from body
Notes:
1. One output is 25 % to 100 % burdened, the other output is 100 % burdened. The output voltage deviation can be ± 5 %.
2. Measured with a 1 µF ceramic capacitor. (see Figure 1)
3. Test by minimal Vin and constant resistive load.
4. Test by nominal Vin and 100 % to 25 % load at 25 % load step change.
5. Measured input reflected ripple current with a simulated source inductance of 12 µH and source capacitance of 47 µF,
ESR <1 Ω at 100 kHz. (see Figure 2)
6. Natural air convection is usually about 30…65 LFM but is not equal to still air.
7. Exceeding the absolute ratings of the converter could cause damage. It is not allowed for continuous operatin ratings.
8. Input filter components are be required to help meet conducted emission class A, which application refer to the EMI filter of
design and feature configuration.
9. An external filter capacitor is required if the module has to meet IEC61000-4-4 and IEC61000-4-5.
Suggested is a value of 330 µF / 100 V of Nippon Chemicon’s KY-Series.
10. All specifications are typical at 25 °C, nominal input voltage and full load unless otherwise noted.
Application circuit IEC61000-4-4 and IEC61000-4-5, see note 9
+ Vin
Nippon Chemicon
KY – Series
330 µF / 100 V
+
Load
- Vin
Page 2 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
6W DC-DC Converter P6E-Series
Output ripple & noise measurement test method
(Figure 1)
Use the following measurement circuit. The oscilloscope mesurement bandwidth must be > 20 MHz.
+Vou
Resistive
load
Cout
1 µF
DC/DC-Converter
Measure points for
oscilloscope
-Vout
Input reflected ripple current measure circuit
(Figure 2)
Input reflected current is measured through a source inductor and a source capacitor at nominal input voltage and full load.
Oscilloscope current probe
+ Vin
12 µH
Measure
point
47 µF
ESR <1Ω
at 100 kHz
Load
- Vin
Remote control function
(Figure 3)
+ Vin
2
“On” state at open
remote control input
Rem.-Ctrl-Input
1k
3
- Vin
“Off” state at remote
control current
-2…-4 mA
1
6
+ Vout
7
- Vout
EMI Filter
The filter components are used to help meet conducted emissions requirement for the module. These components should be closed
mounted as possible to the module. All leads should be minimized to decrease radiated noise.
L
CY
+ Vin

Cin
Load
CX
CX
- Vin
CY
Type
P6E05xxxx
P6E12xxxx
P6E24xxxx
P6E48xxxx
Cin
330 µF
-
CX
22 µF Ceramic
10 µF Ceramic
10 µF Ceramic
2.2 µF Ceramic
CY
220 pF / 3 kV
220 pF / 3 kV
220 pF / 3 kV
220 pF / 3 kV
L
10 µH
10 µH
10 µH
10 µH
Page 3 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
6W DC-DC Converter P6E-Series
Dimensions
Pin connections
Pin
1
2
3
5
6
7
8
Single
-V Input
+V Input
Omitted
Omitted
+V Output
-V Output
N.C.
Single with RC
-V Input
+V Input
Remote contr. on/off
N.C.
+V Output
-V Output
N.C.
Dual
-V Input
+V Input
N.C.
N.C.
+V Output
Common
-V Output
Dual with RC
-V Input
+V Input
Remote contr. on/off
N.C.
+V Output
Common
-V Output
PHI-CON is a trademark of HY-LINE Holding GmbH.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions
carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without
the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and
whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably
expected to result in significant injury to the user. Rev: 02.15 f
Page 4 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
Similar pages