Download

6W DC-DC Converter P6Y-Series
●
●
●
●
Wide 2:1input range
Up to 3500 VDC isolation
Continuous short circuit protection
None conductive plastic case
Model selection guide
Typ
Input nominal voltage Output voltage
[VDC]
[VDC]
Output current
[mA]
Efficiency typ.
[%]
Single output
P6Y1205S
9...18
5.0
1200
P6Y1209S
9...18
9.0
667
P6Y1212S
9...18
12.0
500
P6Y1215S
9...18
15.0
400
P6Y1224S
9...18
24.0
250
P6Y2405S
18...36
5.0
1200
P6Y2409S
18...36
9.0
667
P6Y2412S
18...36
12.0
500
P6Y2415S
18...36
15.0
400
P6Y2424S
18...36
24.0
250
P6Y483R3S
36...72
3.3
1400
P6Y4805S
36...72
5.0
1200
P6Y4809S
36...72
9.0
667
P6Y4812S
36...72
12.0
500
P6Y4815S
36...72
15.0
400
P6Y4824S
36...72
24.0
250
Dual output
P6Y1205D
9...18
±5.0
±600
P6Y1209D
9...18
±9.0
±334
P6Y1212D
9...18
±12.0
±250
P6Y1215D
9...18
±15.0
±200
P6Y1224D
9...18
±24.0
±125
P6Y2405D
18...36
±5.0
±600
P6Y2409D
18...36
±9.0
±334
P6Y2412D
18...36
±12.0
±250
P6Y2415D
18...36
±15.0
±200
P6Y2424D
18...36
±24.0
±125
P6Y4805D
36...72
±5.0
±600
P6Y4809D
36...72
±9.0
±334
P6Y4812D
36...72
±12.0
±250
P6Y4815D
36...72
±15.0
±200
P6Y4824D
36...72
±24.0
±125
Input voltage range reach from 4.5V to 72V and the output voltage range reach from 3.3V to 24V
Suffix: “H” for 3.5kV isolation voltage
77
75
80
80
80
80
83
83
83
83
75
80
83
83
83
83
77
75
80
80
80
80
83
83
83
83
80
83
83
82
82
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
6W DC-DC Converter P6Y-Series
Specifications
Input
Voltage range
Filter
Isolation:
Rated voltage
Resistance
Capacitance
Output
Voltage accuracy
Voltage balance
(dual outputs)
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
12 VDC, 9…18 VDC
24 VDC, 18…36 VDC
48 VDC, 36…72 VDC
Pi Network
1500 VDC, Standard
3500 VDC, Suffix “H”
109 Ω
390 pF, typ.
± 1%, max.
± 1%
60 mVp-p, max.
Continuous
Automatic
± 0.5%, max.
± 0.5%, max.
± 0.02% / °C
General
Efficiency
Switching frequency
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
74% to 83%
100 kHz…400 kHz
-40 °C to +71 °C
100 °C max.
-40 °C to +125 °C
None required
Up to 90%,
None condensing
Free-air convection
Cooling
Physical
Dimensions
Weight
31.75x20.32x10.16 mm
17 g plastic standard,
19 g metal suffix “M”
None conductive plastic
Case material
Dimensions
27.94
31.75
0.5
P6Y1205S
PHI-CON
1
12
bottom view
20.32
24
All dimensions in mm
Tolerance ±0.25 mm
13
0.5
2.54
Pin connections
Pin
1
2
3
9
10
11
12
13
14
15
16
22
23
24
1.5kV version
Single
Dual
+V Input
+V Input
N.C.
-V Output
N.C.
Common
Omitted
Omitted
-V Output
Common
+V Output
+V Output
-V Input
-V Input
-V Input
-V Input
+V Output
+V Output
-V Output
Common
Omitted
Omitted
N.C.
Common
N.C.
-V Output
+V Input
+V Input
15.24
10.16
3.5kV version
Single
Dual
Omitted
Omitted
-V Input
-V Input
-V Input
-V Input
Omitted
Common
Omitted
Omitted
N.C.
-V Output
Omitted
Omitted
Omitted
Omitted
+V Output
+V Output
Omitted
Omitted
-V Output
Common
+V Input
+V Input
+V Input
+V Input
Omitted
Omitted
3.05 min.
Life Support Policy: HY-LINE does not
authorize the use of any of its products
for use in life support devices or systems
without the express written approval of
an officer of the Company. Life support
systems are devices which support or
sustain life, and whose failure to perform,
when properly used in accordance with
instructions for use provided in the
labeling, can be reasonably expected to
result in significant injury to the user.
Rev: 2.06 f
Page 2 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
Similar pages