Download

12W DC-DC Converter P12A-Series
●
●
●
●
●
●
●
Efficiency up to 90 %
Wide 2:1 input range
1500 VDC isolation
Continuous short circuit protection
Five – sided continuous shield
Standard package 2” x 1” x 0.4”
MTBF 1.12 M hours
Model selection guide
Typ
Single output
P12A123R3S
P12A1205S
P12A127R2S
P12A1209S
P12A1212S
P12A1215S
P12A1218S
P12A1224S
P12A243R3S
P12A2405S
P12A247R2S
P12A2409S
P12A2412S
P12A2415S
P12A2418S
P12A2424S
P12A483R3S
P12A4805S
P12A487R2S
P12A4809S
P12A4812S
P12A4815S
P12A4818S
P12A4824S
Dual output
P12A123R3D
P12A1205D
P12A127R2D
P12A1209D
P12A1212D
P12A1215D
P12A1218D
P12A1224D
P12A243R3D
P12A2405D
P12A247R2D
P12A2409D
P12A2412D
P12A2415D
P12A2418D
P12A2424D
P12A483R3D
P12A4805D
P12A487R2D
P12A4809D
P12A4812D
P12A4815D
P12A4818D
P12A4824D
Input nominal
voltage
[VDC]
Input quiescent
current
[mA]
Output voltage
Output current
Efficiency typ.
capacitive load
[VDC]
[mA]
[%]
[µF]
9...18
9...18
9...18
9...18
9...18
9...18
9...18
9...18
18...36
18...36
18...36
18...36
18...36
18...36
18...36
18...36
36...72
36...72
36...72
36...72
36...72
36...72
36...72
36...72
30
30
30
30
30
30
30
30
25
25
25
25
25
25
25
25
20
20
20
20
20
20
20
20
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
2400
2400
1670
1330
1000
800
670
500
2400
2400
1670
1330
1000
800
670
500
2400
2400
1670
1330
1000
800
670
500
78
83
83
84
84
85
85
85
78
83
83
84
85
85
85
85
78
83
83
84
85
85
85
85
6800
6800
4700
2200
1000
1000
470
470
6800
6800
4700
2200
1000
1000
470
470
6800
6800
4700
2200
1000
1000
470
470
9...18
9...18
9...18
9...18
9...18
9...18
9...18
9...18
18...36
18...36
18...36
18...36
18...36
18...36
18...36
18...36
36...72
36...72
36...72
36...72
36...72
36...72
36...72
36...72
30
30
30
30
30
30
30
30
25
25
25
25
25
25
25
25
20
20
20
20
20
20
20
20
±3.3
±5.0
±7.2
±9.0
±12.0
±15.0
±18.0
±24.0
±3.3
±5.0
±7.2
±9.0
±12.0
±15.0
±18.0
±24.0
±3.3
±5.0
±7.2
±9.0
±12.0
±15.0
±18.0
±24.0
±1200
±1200
±830
±670
±500
±400
±330
±250
±1200
±1200
±830
±670
±500
±400
±330
±250
±1200
±1200
±830
±670
±500
±400
±330
±250
78
82
82
83
83
85
85
85
78
83
83
84
85
85
85
85
78
83
84
84
85
86
86
86
2 x 3300
2 x 3300
2 x 2200
2 x 1000
2 x 680
2 x 330
2 x 220
2 x 220
2 x 3300
2 x 3300
2 x 2200
2 x 1000
2 x 680
2 x 330
2 x 220
2 x 220
2 x 3300
2 x 3300
2 x 2200
2 x 1000
2 x 680
2 x 330
2 x 220
2 x 220
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
12W DC-DC Converter P12A-Series
Specifications
Input
Voltage range
Filter
Isolation Voltage:
Input to Output
Input/Output to Case
Resistance
Capacitance
Output
Voltage accuracy
Voltage balance
(dual outputs)
Ripple and noise
(at 20 MHz BW)
Over current protection
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
12 VDC, 9…18 VDC
24 VDC, 18…36 VDC
48 VDC, 36…72 VDC
Pi - type
1500 VDC for 1 min., tested 1s
1000 VDC for 1 min.
109 Ω
470 pF, typ.
± 1%, max.
± 1%
General
Efficiency
Switching frequency
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
78...86 %
200 kHz, typ.
-40 °C to +85 °C
100 °C, max.
-40 °C to +125 °C
None required
Up to 90%,
non-condensing
Free-air convection
Cooling
Physical
Dimensions
Weight
Case material
100 mVp-p, max.
> 120% of max. current
Continuous
Automatic
± 0.5%, max.
± 0.5%, max.
± 0.02% / °C
50.80 x 25.40 x 10.16 mm
30.0 g
Nickel-coated copper
metal
Epoxy (UL94V-0 rated)
Potting material
Soldering temperature
1.5mm distance from case
260°C for 10s
Dimensions
Output ripple and noise reduction
+
DC Power
Source
-
+input
+output
DC/DC Converter
-input
Scope
Load
To reduce ripple and noise, it is recommended to use
4.7µF capacitors to the output
-output
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without
the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and
whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably
expected to result in significant injury to the user. Rev: 3 / 08f
Page 2 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
Similar pages