Download

30W DC-DC Converter P30A-Series
●
●
●
●
●
●
Wide 2:1 input range
1500 VDC isolation
Continuous short circuit protection
Standard package 2” x 2” x 0.4”
MTBF >1,12 Mhrs
-40...+85°C operating temperature range
Model guide
Type
Single output
P30A1205S
P30A127R2S
P30A1209S
P30A1212S
P30A1215S
P30A1218S
P30A1224S
P30A243R3S
P30A2405S
P30A247R2S
P30A2409S
P30A2412S
P30A2415S
P30A2418S
P30A2424S
P30A483R3S
P30A4805S
P30A487R2S
P30A4809S
P30A4812S
P30A4815S
P30A4818S
P30A4824S
Dual output
P30A123R3D
P30A1205D
P30A127R2D
P30A1209D
P30A1212D
P30A1215D
P30A1218D
P30A1224D
P30A243R3D
P30A2405D
P30A247R2D
P30A2409D
P30A2412D
P30A2415D
P30A2418D
P30A2424D
P30A483R3D
P30A4805D
P30A487R2D
P30A4809D
P30A4812D
P30A4815D
P30A4818D
P30A4824D
Input voltage
range
[VDC]
Input current
no load
full load
[mA]
[mA]
Output voltage
Output current
Efficiency typ.
[VDC]
[mA]
[%]
Capacitive
load max.
[µF]
9...18
9...18
9...18
9...18
9...18
9...18
9...18
18...36
18...36
18...36
18...36
18...36
18...36
18...36
18...36
36...72
36...72
36...72
36...72
36...72
36...72
36...72
36...72
30
30
30
30
30
30
30
25
25
25
25
25
35
35
35
25
25
25
25
25
25
25
30
3048
3012
2976
2976
2941
2941
2941
1031
1488
1488
1436
1436
1436
1436
1436
522
753
744
744
726
710
710
710
5.0
7.2
9.0
12.0
15.0
18.0
24.0
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
3.3
5.0
7.2
9.0
12.0
15.0
18.0
24.0
6000
4166
3333
2500
2000
1666
1250
6000
6000
4166
3333
2500
2000
1666
1250
6000
6000
4166
3333
2500
2000
1666
1250
82
83
84
84
85
85
85
80
84
84
87
87
87
87
87
79
83
84
84
86
88
88
88
3300
3300
2200
1000
1000
680
680
3300
3300
3300
2200
1000
1000
680
680
3300
3300
3300
2200
1000
1000
680
680
9...18
9...18
9...18
9...18
9...18
9...18
9...18
9...18
18...36
18...36
18...36
18...36
18...36
18...36
18...36
18...36
36...72
36...72
36...72
36...72
36...72
36...72
36...72
36...72
25
25
25
25
25
35
35
35
25
25
25
25
25
25
25
30
20
20
20
20
20
20
20
20
2115
3048
3012
2976
2976
2941
2941
2941
1057
1488
1488
1470
1470
1436
1436
1436
515
735
735
735
718
710
710
710
±3.3
±5.0
±7.2
±9.0
±12.0
±15.0
±18.0
±24.0
±3.3
±5.0
±7.2
±9.0
±12.0
±15.0
±18.0
±24.0
±3.3
±5.0
±7.2
±9.0
±12.0
±15.0
±18.0
±24.0
±3000
±3000
±2083
±1666
±1250
±1000
±833
±625
±3000
±3000
±2083
±1666
±1250
±1000
±833
±625
±3000
±3000
±2083
±1666
±1250
±1000
±833
±625
78
82
83
84
84
85
85
85
78
84
84
85
85
87
87
87
80
85
85
85
87
88
88
88
2 x 2200
2 x 2200
2 x 1000
2 x 1000
2 x 1000
2 x 470
2 x 330
2 x 220
2 x 2200
2 x 2200
2 x 1000
2 x 1000
2 x 1000
2 x 470
2 x 330
2 x 220
2 x 2200
2 x 2200
2 x 1000
2 x 1000
2 x 1000
2 x 470
2 x 330
2 x 220
Page 1 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
30W DC-DC Converter P30A-Series
Specifications
Input
Start up time
Filter
Isolation:
Rated voltage, input to output
Rated voltage,
input or output to case
Resistance
Capacitance
Output
Voltage accuracy
Voltage balance
(dual outputs)
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Over load protection
Short circuit restart
Line voltage regulation
Load regulation, single outp. type
Load regulation, dual outp. type
Temperature coefficient
General
Switching frequency
Safety standard
Reliability Calculated MBTF
Environmental
Operating ambient temperature
Case temperature
Storage temperature
Derating
Humidity
20 mS, typ.
Capacitors
1500 VDC, 3s tested
1000 VDC
109 Ω
1000 pF, typ.
±1%
±1%
100 mVp-p
Indefinite (Automatic recovery)
140 %, typ.
Automatic
± 0.5 %
± 0.5% @ 0%...100% load
± 0.5% @ 10%...100% load
± 0.02% / °C
Cooling
Physical
Dimensions
Weight
Case material
Potting Material
Absolute maximum ratings
Vin 12 V models
Vin 24 V models
Vin 48 V models
Pin soldering temperature
distance 1.5 mm from body
125 kHz, typ.
IEC 60950-1
1.12 Mio. h
-40 °C to 85 °C see derating
100 °C, max.
-40 °C to 125 °C
None required
Up to 95%,
non-condensing
Free-air convection
50.80 x 50.80 x 10.16 mm
60 g
Nickel-coated brass
Epoxy UL94V-0 rated
25 VDC max. for 0.1 s max.
50 VDC max. for 0.1 s max.
100 VDC max. for 0.1 s max.
260°C for 10sec
Efficiency vias load change
Page 2 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
30W DC-DC Converter P30A-Series
Dimensions
Pin connections
Pin Single
output
1
+V input
2
-V input
3
+V output
4
Omitted
5
-V output
Dual
output
+V input
-V input
+V output
Common
-V output
Output ripple and noise reduction
1.
2.
3.
4.
5.
6.
Ripple and Noise measured with 20 MHz bandwidth
Tested by minimal Vin and constant resistive load.
Measured Input reflected ripple current with a simulated source inductance of 12 µH.
Exceeding the absolute ratings of the unit could cause damage. It is not allowed for continuous operating.
Operation under no-load conditions will not damage these devices, however they may not meet all listed specifications.
For reduce converter’s ripple and noise, it is recommended to add a 4.7..100 μF(2 x 4.7..68 μF for dual output) capacitor
on output. For EMI performance improvement, it is recommended to add a 12μH inductor and a 10..100 μF capacitor in
input end.
PHI-CON is a trademark of HY-LINE Power Components.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the
instructions for use carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems
without the express written approval of an officer of the Company. Life support systems are devices which support or
sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the
labeling, can be reasonably expected to result in significant injury to the user. Rev: 04.13 f
Page 3 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
Similar pages