DR024-F2_2016.pdf

2 to 18GHz Instantaneous
Frequency Measurement Unit
DR024-F2
2 to 18GHz Instantaneous Frequency Measurement Unit
The DR024-F2 uses proprietary Teledyne Defence technology
to provide state of the art performance in a package measuring
152mm x 147mm x 30mm weighing 1.45kg.
The DR024-F2 is an externally triggered IFM, providing a digital
12-bit output word of the RF input with every sample. The
internal analogue bandwidth is sufficient to capture a 50ns
pulse.
With a resolution of 12 bits, the DR024-F2 gives a nominal
frequency resolution of 3.93MHz and an rms accuracy of
4.5MHz with an SNR of 3dB or better.
Designed specifically for fast jet applications this product will
withstand the most demanding of environments. It is
characterised for –40ºC to +85ºC. For applications outside this
range, please contact the Sales Dept.
External connections are made via a 51 way high density D type
for power and digital I/O and SMA for the RF input.
This product is recommended for new designs. Other IFM
configurations are available; please contact the Sales
Department for further information.
FEATURES
APPLICATIONS
•
•
•
•
•
•
•
•
•
•
•
•
•
•
12 Bit resolution
External trigger
50ns pulse capable
16GHz Instantaneous bandwidth
-50dBm sensitivity
Small form factor
Low weight
Low power consumption
Electronic support measures (ESM)
Radar warning receivers (RWR)
ECM set-on
Airborne, fixed wing & rotary
Land
Naval
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] Web: www.teledynedefence.co.uk
DR024-F2 | 022016 | Page 1 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR024-F2
ELECTRICAL SPECIFICATIONS
Ref
Parameter
Units
Value
1
Operating Frequency Range
GHz
1.955
18.045
2
Unambiguous Bandwidth
GHz
1.5
18.5
3
Frequency Resolution
MHz
3.93
4
Digital Frequency Resolution
Bits
12
5
Throughput Time
6
RF Input Dynamic Range
7
RF Input Signal/Noise Ratio
dB
3
8
RF Input Pulse Width
ns
50
9
Recovery Time
ns
10
RF Input VSWR
11
Frequency Error (RMS) at 3 dB SNR
MHz
12
Frequency Peak Error at 3 dB SNR
MHz
13
Peak Error Rate at 3 dB SNR
14
Bad Data Error Rate at 3 dB SNR
15
Simultaneous Signal: Level
dBc
16
Simultaneous Signal: Frequency Separation
MHz
17
Overload Power
dBm
18
Temperature Range (operating)
19
Power Consumption
20
Min
Nom
Notes
Max
1
ns
330
370
dBm
-50
10
2
3
CW
4
50
5
2.2:1
%
%
°C
4.5
6
0.04
7
2
8
15
9
10
100
9
20
-40
10
85
Watts
18.5
Power Supply Current: +15v Rail
mA
850
21
Power Supply Current: +5v Rail
mA
1000
22
Weight (Approx.)
kg
1.55
1.
2.
3.
4.
5.
Nominal frequency resolution is unambiguous bandwidth divided by number of bits.
See timing diagrams.
Minimum SNR required for nominal operation.
Minimum pulse width is defined by internal video bandwidth.
Given as the maximum time required between the removal of a pulse of RF at any power within the operating dynamic
range and the arrival of the next pulse to ensure the correct measurement of the second pulse.
6. The actual resolution, i.e., the change of frequency required to change 1 bit of the output word varies with frequency. The
rms accuracy is calculated as the standard deviation of the frequency distribution. The rms accuracy is specified for 3dB.
The rms error excludes those measurements that are flagged as “bad data”.
7. The percentage number of measurements that exceed the peak error frequency.
8. The percentage number of measurements that cause the “bad data” signal to be asserted.
9. Simultaneous signals are defined as signals which overlap by at least 30ns during a measurement cycle.
10. A valid measurement will be made on the larger of two signals provided that a) the amplitude difference between them is
10dB and b) there is at least 100MHz frequency separation.
11. Maximum input power without damage.
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] Web: www.teledynedefence.co.uk
DR024-F2 | 022016 | Page 2 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR024-F2
TIMING INFORMATION
Operation with external trigger
Parameter
Description
Min
Timings
Max
Trfd
Delay from RF to External Trigger
4 ns
Tetrgw
External Trigger width
50 ns
Tst
Delay from External Trigger to Strobe
40 ns
300 ns
Tdvld
Delay from External Trigger to data Valid
330 ns
370 ns
Tdvldw
Data Valid width
330 ns
370 ns
Tsu
Data set up time w.r.t. Data Valid
20 ns
Thld
Data hold time w.r.t. Data Valid
20 ns
Tshol
Strobe hold time w.r.t. Data Valid
0 ns
12 ns
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] Web: www.teledynedefence.co.uk
DR024-F2 | 022016 | Page 3 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR024-F2
TIMING INFORMATION
Strobe only, no external trigger.
Parameter
Description
Tdvldst
Delay from Strobe to data Valid
Tdvldw
Data Valid width
Tsu
Data set up time w.r.t. Data Valid
Thld
Data hold time w.r.t. Data Valid
Tshol
Strobe hold time w.r.t. Data Valid
Min
320 ns
330 ns
Timings
Max
360 ns
370 ns
20 ns
20 ns
0 ns
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] Web: www.teledynedefence.co.uk
DR024-F2 | 022016 | Page 4 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR024-F2
PIN DESIGNATIONS
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
Signal
+15V
+15V
+15V
0V
Not Used
0V
External Trig
0V
Strobe
0V
Data Valid +
Data Valid 0V
Not Used
Not Used
0V
Bad Data Bad Data +
0V
Not Used
Not Used
Not Used
Not Used
+5V
+5V
+5V
Freq 11+
Freq 11 Freq 10+
Freq 10 Freq 9+
Freq 9 Freq 8+
Freq 8 Freq 7+
Freq 7 Freq 6+
Freq 6 Freq 5 +
Freq 5 Freq 4+
Freq 4 Freq 3+
Freq 3 Freq 2+
Freq 2 Freq 1 +
Freq 1 Freq 0+
Freq 0 0V
Direction
Power
Power
Power
Return
Return
Input
Return
Input
Return
Output
Output
Return
Return
Output
Output
Return
Power
Power
Power
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Return
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] Web: www.teledynedefence.co.uk
DR024-F2 | 022016 | Page 5 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR024-F2
Environmental Screening
100% of units subjected to: burn in 8 hours operational at 71ºC, random vibration (as below), 5min per axis, thermal
shock (as
Below), random vibration (as below), 5min per axis.
Environmental Data
Compliance can be shown by similarity to the following environmental conditions
Sinusoidal Vibration: MIL-STD-202F, Method 204 - 5g profile between 5 and 104Hz for 90 min per axis
Random Vibration: MIL-STD-810D, Method 514.3 – specified profile (below) with max of 0.2g²/Hz for 60 min per axis,
20 to 2000Hz
Mechanical Shock: MIL-STD-202F, Method 213B – 15g/11ms, 3 shocks in each axis in each direction (18 total)
Acceleration: MIL-STD-202F, Method 212A, condition B, 6 to 14g
High Temperature storage: MIL-STD-810D, Method 501.2 - 95ºC for 8 hours
High Temperature operational: MIL-STD-820D, Method 501.2 – 71ºC / 30min, 60ºC / 60min, 55ºC / 4hr Thermal
Shock: 10 Cycles of –40ºC to 71ºC, 5 min ramp, 2hr dwell
Low Temperature storage: MIL-STD-810D, Method 502.2 - -54ºC for 8hours. Low temperature operational: MILSTD-810D, Method 502.2 - -40ºC / 60min.
Combined temperature, altitude & humidity: MIL-STD-810D. Method 520 – temperature –40ºC to 70ºC, storage
condition sea level to 17000m (87.6mb), operating condition sea level to 11000m (228mb), relative humidity at sea
level 75%, 10 Cycles.
Humidity: MIL-STD-810D, Method 507.2, procedure 2 – RH 85% to 95%, temperature 30ºC to 60ºC, 24 hour
cycle, 10 cycles.
EMI/EMC: Generally in accordance with MIL-STD-461E. Please note that system precautions must be taken to
prevent interfering signals entering the high gain RF front end.
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] Web: www.teledynedefence.co.uk
DR024-F2 | 022016 | Page 6 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR024-F2
OUTLINE DRAWING
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] Web: www.teledynedefence.co.uk
DR024-F2 | 022016 | Page 7 of 7