RR017_2016.pdf

2-18 GHz Radar
Warning Receiver
RR017
2-18 GHz Radar Warning Receiver
The RR017 is designed for Radar Warning Receiver (RWR)
applications where low cost and small size and are of prime
importance, with filtering, amplification, detection and pulse
parameter measurement being combined into one multifunction unit.
Two amplitude measurement channels allow direction
finding by amplitude comparison between adjacent
antennas. A 20dB switched attenuator can be selected to
allow amplitude measurement above –15dBm. An IFM, fed
from one of the amplitude channels via an SPDT switch,
performs 10 bits of frequency measurement on the selected
input. Frequency resolution is nominally 25 MHz over a 2 to
18 GHz band. The RR017 is internally triggered and
generates a full PDW giving the following data: Time of
arrival, Pulse amplitude (from the two selected antennas),
Pulse frequency and Pulse width.
The standard data interface is USB2 with optional 50MHz
clocked 16-bit parallel interface via a separate 37 way MDM
connector.
The small size eases the burden on UAV and AFV payloads
in particular and the reduced power consumption renders a
double benefit, as a smaller, lighter power supply is
required.RF connections are made by SMA, DC power &
USB2 uses a 25 way MDM, parallel data uses a separate 37
way MDM connector.
External 50 MHz clock input can be selected to operate the
time of arrival (TOA) counter (shared clock source for the
parallel data output PDWs), hence the PDWs generated have
fully correlated TOA digits.
FEATURES
APPLICATIONS
•
2 to 18 GHz Frequency range
•
25MHz Frequency resolution
•
•
•
•
•
0.2dB Amplitude resolution
•
Pulse Descriptor Word Output
•
USB2 interface
•
Sensitivity –57dBm (or better)
•
Small form factor
Affordable Radar Warning Receiver for
AFV
UAV
Remote sensing
• Air, sea and land platforms
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence, Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] | Web: www.teledynedefence.co.uk
RR017 | 022016 | Page 1 of 7
RR017
Electrical Specification: -20ºC to +85ºC
Operating Frequency
2 to 18 GHz
Out of Band Rejection
DC to 1.5 GHz > 40 dB 20 to 26 GHz > 30 dB
Operating Dynamic Range - Digital attenuator unselected
-57 to -15 dBm
Operating Dynamic Range - Digital attenuator selected
-37 to +5 dBm
Frequency Measurement Coding
1900 + 25xCode MHz
Frequency Measurement Resolution
10 bits, 25 MHz nom
Frequency Measurement Accuracy over operating dynamic range
< 15 MHz RMS
Minimum Pulse Width
75 nsec
Frequency Measurement Triggering
Internal
Pulse Width & Time of Arrival Resolution
10 nsec
Amplitude Measurement Resolution
9 bits, 0.2dB nom
Amplitude Measurement Coding
-70 + 0.2xCode dB
Amplitude Measurement Accuracy
Amplitude Measurement Tracking
(Between video outputs at the Same Frequency, Temperature & Power
level)
Amplitude Measurement Tracking (at same frequency and temperature,
with less than 20dB difference between
2 signals)
Pulse on Pulse performance (Simultaneous signal >10dB)
< 1.5 dB abs ave
Amplitude measurement Video Coupling
DC coupled
Recovery Time
300 ns typical (500 nsec max)
RF Input Switch Isolation (RF inputs 1-2)
30 dB min
RF Input Switch Isolation (A-B)
70 dB min
RF Input Switch Speed
< 200 nsec
< 0.5 dB abs ave
< 1.5 dB abs ave
Yes (see Note 1)
RF Input Switch Control
LVTTL
Input Return Loss at Ports A1,A2,B1,B2
7 dB min (10 dB typ)
Clock Input (req’d if using Parallel data port
or TOA Correlation)
50 MHz
Dimensions
160 x 160 x 20mm
Weight
975 grams max
Microwave Input Connectors
SMA Female
Power and control
25 & 37 way MDM
Power Dissipation (operating)
20W max
Power-up Time
2 seconds max
Note 1: Minimum Frequency separation 100MHz, Leading edge separation > 500ns.
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence Ltd Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] Web: www.teledynedefence.co.uk
RR017 | 022016 | Page 2 OF 7
BLOCK DIAGRAM
OPERATING MODES
LVTTL Control inputs are provided for direct control over the Input selection, the IFM measurement channel and the
switched attenuator but in addition these functions may be controlled from the USB2 interface although this introduces a
delay depending on the USB2 transfer time. An auto mode is available for the attenuator and the IFM channel to simplify the
operation.
The IFM can be directed to either of the measurement channels by the use of a TTL or USB command or alternatively using
Auto Freq mode the internal thresholding determines the amplitude channel with the highest signal and route the IFM
accordingly. This process functions on a pulse-by-pulse basis but reduces the minimum pulse width to 120ns due to the
switching delay. The mode of operation can be specified from the USB2 interface and can be changed as required.
The switched attenuator can be introduced, to both channels simultaneously, to enable the amplitude of high-level signals to
be measured. This can be manually controlled or using Auto Atten mode the system detects on over- range measurement
and switch the attenuation automatically. This process functions on a pulse-by-pulse basis but reduces the minimum pulse
width to 200ns due to the switching delay.
RR017 generates a PDW following the end of a received pulse, the maximum reported pulse width is 650us. Under CW
conditions a PDW is generated after a pre-settable time, up to the maximum 650us with the CW Present flag set, PDWs
continue to be generated with the same interval for the duration of the CW signal.
PARALLEL DATA TRANSFER
Each PDW is transferred in 8 clock cycles. The diagram illustrates a full transfer plus the start of the
next transfer. Each Word block represents a portion of PDW data.
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence Ltd Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] Web: www.teledynedefence.co.uk
RR017 | 022016 | Page 3 OF 7
RR017
Pulse Descriptor Word (PDW) Format
Each PDW is transferred in 8 clock cycles. The diagram illustrates a full transfer plus the start of the next transfer.
Each Word block represents a portion of PDW data.
BIT
DataWords (1/2)
DataWords (3/4)
DataWords (3/4)
0
Frequency
0
Pulse Width 0
Time
of
Arrival
0
1
Frequency
1
Pulse Width 1
Time
of
Arrival
1
2
Frequency
2
Pulse Width 2
Time
of
Arrival
2
3
Frequency
3
Pulse Width 3
Time
of
Arrival
3
4
Frequency
4
Pulse Width 4
Time
of
Arrival
4
5
Frequency
5
Pulse Width 5
Time
of
Arrival
5
6
Frequency
6
Pulse Width 6
Time
of
Arrival
6
7
Frequency
7
Pulse Width 7
Time
of
Arrival
7
8
Frequency
8
Pulse Width 8
Time
of
Arrival
8
9
Frequency
9
Pulse Width 9
Time
of
Arrival
9
10
Reserved
Pulse Width 10
Time
of
Arrival
10
11
Reserved
Pulse Width 11
Time
of
Arrival
11
12
Amplitude
CHA
0
Pulse Width 12
Time
of
Arrival
12
13
Amplitude
CHA
1
Pulse Width 13
Time
of
Arrival
13
14
Amplitude
CHA
2
Pulse Width 14
Time
of
Arrival
14
15
Amplitude
CHA
3
Pulse Width 15
Time
of
Arrival
15
0
Amplitude
CHA
4
POP Present CHA
Time
of
Arrival
16
1
Amplitude
CHA
5
POP Present CHB
Time
of
Arrival
17
2
Amplitude
CHA
6
CW present
Time
of
Arrival
18
3
Amplitude
CHA
7
Ambiguity Bad Data
Time
of
Arrival
19
4
Amplitude
CHA
8
Threshold Bad Data
Time
of
Arrival
20
5
Reserved
Active IFM Channel
Time
of
Arrival
21
6
Amplitude
CHB
0
Ant Select 0 state
Time
of
Arrival
22
7
Amplitude
CHB
1
Ant Select 1 state
Time
of
Arrival
23
8
Amplitude
CHB
2
Re-Measure state
Time
of
Arrival
24
9
Amplitude
CHB
3
Auto Freq state
Time
of
Arrival
25
10
Amplitude
CHB
4
Auto Atten state
Time
of
Arrival
26
11
Amplitude
CHB
5
Reserved
Time
of
Arrival
27
12
Amplitude
CHB
6
Reserved
Time
of
Arrival
28
13
Amplitude
CHB
7
Reserved
Time
of
Arrival
29
14
Amplitude
CHB
8
Reserved
Time
of
Arrival
30
15
Reserved
Reserved
Time
of
Arrival
31
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence Ltd Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] Web: www.teledynedefence.co.uk
RR017 | 022016 | Page 4 OF 7
RR017
PSU & Control Interface: 25-way MDM
Pin
Signal
Direction
Description
1
USBDM
Bi-dir
USB data minus
2
USB Vcc
USB Power
Power from host USB controller
3
Re-Measure
Input – LVTTL2
Initiate manual measurement
4
IFM Channel Select
Input – LVTTL2
IFM channel selection (A-B)
5
Antenna Select (0)
Input – LVTTL2
Antenna channel A selection
6
CLK IN (-)
Input – LVDS
Master clock input 1
7
~BLANKING
Input – LVTTL2
Blanking signal input
8
Reserved1
Output – LVTTL
Spare logic output
9
+5V
Input
Positive supply (2A max)
10
GND
Ground
Supply ground
11
+5V
Input
Positive supply (2A max)
12
GND
Ground
Supply ground
13
+3.3V
Input
Positive supply (1A max)
14
USBDP
Bi-dir
USB data plus
15
Reserved1
Input
Spare logic input
16
DGND
Ground
Digital ground
17
Attenuator
Input – LVTTL2
Attenuator control
18
Antenna Select (1)
Input – LVTTL2
Antenna channel B selection
19
CLK IN (+)
Input - LVDS
Master clock input 1
20
Reserved1
Input
Spare logic input
21
GND
Ground
Supply ground
22
-5V
Input
Negative supply (300mA typ)
23
GND
Ground
Supply ground
24
GND
Ground
Supply ground
25
+3.3V
Input
Positive supply (1A max)
1 This pin is reserved and must be left floating for normal unit operation.
2 LVTTL inputs are +5V tolerant.
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence Ltd Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] Web: www.teledynedefence.co.uk
RR017 | 022016 | Page 5 OF 7
RR017
Parallel Data Interface: 37-way MDM
Pin
Signal
Direction
Description
1
DGND
Ground
Digital Ground
2
Data(15)+
Output -LVDS
Parallel Data Word
3
Data(14)+
Output –LVDS
Parallel Data Word
4
Data(13)+
Output –LVDS
Parallel Data Word
5
Data(12)+
Output –LVDS
Parallel Data Word
6
Data(11)+
Output –LVDS
Parallel Data Word
7
Data(10)+
Output –LVDS
Parallel Data Word
8
Data(09)+
Output –LVDS
Parallel Data Word
9
Data(08)+
Output –LVDS
Parallel Data Word
10
Data(07)+
Output –LVDS
Parallel Data Word
11
Data(06)+
Output –LVDS
Parallel Data Word
12
Data(05)+
Output –LVDS
Parallel Data Word
13
Data(04)+
Output –LVDS
Parallel Data Word
14
Data(03)+
Output –LVDS
Parallel Data Word
15
Data(02)+
Output –LVDS
Parallel Data Word
16
Data(01)+
Output –LVDS
Parallel Data Word
17
Data(00)+
Output –LVDS
Parallel Data Word
18
DataSync+
Output –LVDS
Data Sync
19
CLK_IN+
Input - LVDS
Master Clock Input
20
Data(15)-
Output -LVDS
Parallel Data Word
21
Data(14)-
Output –LVDS
Parallel Data Word
22
Data(13)-
Output –LVDS
Parallel Data Word
23
Data(12)-
Output –LVDS
Parallel Data Word
24
Data(11)-
Output –LVDS
Parallel Data Word
25
Data(10)-
Output –LVDS
Parallel Data Word
26
Data(09)-
Output –LVDS
Parallel Data Word
27
Data(08)-
Output –LVDS
Parallel Data Word
28
Data(07)-
Output –LVDS
Parallel Data Word
29
Data(06)-
Output –LVDS
Parallel Data Word
30
Data(05)-
Output –LVDS
Parallel Data Word
31
Data(04)-
Output - LVDS
Parallel Data Word
32
Data(03)-
Output - LVDS
Parallel Data Word
33
Data(02)-
Output - LVDS
Parallel Data Word
34
Data(01)-
Output - LVDS
Parallel Data Word
35
Data(00)-
Output - LVDS
Parallel Data Word
36
DataSync-
Output - LVDS
Data Sync
37
CLK_IN-
Input - LVDS
Master Clock Input
2
2
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence Ltd Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] Web: www.teledynedefence.co.uk
RR017 | 022016 | Page 6 OF 7
RR017
OUTLINE DRAWING
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence Ltd Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] Web: www.teledynedefence.co.uk
RR017 | 022016 | Page 7 OF 7