S2CP20201.pdf

9/2010
DC TO 20 GHz
NON REFLECTIVE SINGLE-POLE
DOUBLE-THROW SWITCH
S2CP20201
S2CP20201
Typical Values
Low Insertion Loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Output Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Third Order I.P. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Stage CougarPak™ for Switches
<3.0 dB
>45 dB
+22.0 dBm
+XX dBm
S2CP20201
2 Stage CougarPak™ for Switches
SPECIFICATIONS*
Parameter
Typical
Frequency (Min.)
DC - 20 GHz
DC - 20 GHz
DC - 20 GHz
<1.5 dB
<2.2 dB
<3.0 dB
1.8 dB
3.5 dB
3.8 dB
2.0 dB
3.7 dB
4.0 dB
DC-500 MHz
500-18000 MHz
18000-20000 MHz
63 dB
45 dB
45 dB
60.0 dB
42.0 dB
42.0 dB
60.0 dB
42.0 dB
42.0 dB
Input/Output
DC-500 MHz
500-18000 MHz
18000-20000 MHz
<1.3:1
<1.3:1
<1.4:1
1.9:1
1.9:1
1.9:1
2.0:1
2.0:1
2.0:1
+22.0 dBm
+24.0 dBm
+22.0 dBm
+20.0 dBm
+22.0 dBm
+20.0 dBm
+19.0 dBm
+21.0 dBm
+19.0 dBm
75/50 ηsec
80/60 ηsec
80/60 ηsec
4 mA
5 mA
5 mA
Insertion Loss (Max.)
DC-500 MHz
500-18000 MHz
18000-20000 MHz
Isolation (Min.)
SWR (Max.)^
Guaranteed*
0 to 50 °C
-55 to +85 °C
Power Output (Min.)
@ 1dB comp. DC-500 MHz
500-18000 MHz
18000-20000 MHz
Switching Time†
DC-20 GHz
DC Current (Max.)
* Measured in a 50-ohm system at –5 Vdc unless otherwise specified.
^ Insertion loss state. † 50% TTL control to 10% or 90% RF.
INTERMODULATION PERFORMANCE
Typical @ 25 °C, –5 Volts, and 1000 MHz
LOGIC TABLE
TTL
CONTROL
J1-J2
J1-J3
LOW
ISOLATION
INSERTION
LOSS
HI
INSERTION
LOSS
ISOLATION
LOW is defined as 0 to +0.8 V
HI is defined as +2.4 V to +5.5 V
S2CP20201
Second Order Two Tone Intercept Point . . . . . . . . . . . . . . .
Third Order Two Tone Intercept Point . . . . . . . . . . . . . . . . .
+XX dBm
+XX dBm
ABSOLUTE MAXIMUM RATINGS
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65 to +125 °C
Maximum Case Temperature . . . . . . . . . . . . . . . . . . . . . . . .
+150 °C
Maximum DC Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–5.5 Volts
Maximum Continuous RF Input Power . . . . . . . . . . . . . . . .
+28 dBm
Maximum Short Term Input Power (1 Minute Max.) . . . . . .
+31 dBm
Maximum Peak Power (3 µsec Max.) . . . . . . . . . . . . . . . . . .
+34 dBm
Burn-in Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+125 °C
DIMENSIONS ARE IN INCHES [MILLIMETERS]