murs220-murs260.pdf

MURS220
MURS240
MURS260
ULTRAFAST RECTIFIER
VOLTAGE RANGE 200 to 600 Volts CURRENT 2.0 Amperes
FEATURES
*
*
*
*
*
*
*
High reliability
Low leakage
Low forward voltage
High current capability
Ultrafast switching speed
High surge capability
Good for switching mode circuit
m
i
l
e
MECHANICAL DATA
*
*
*
*
*
Case: Molded plastic
Epoxy: Device has UL flammability classification 94V-O
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 0.098 gram
Pr
in
y
r
a
DO-214AA
0.083 (2.11)
0.077 (1.96)
0.155 (3.94)
0.130 (3.30)
0.180 (4.57)
0.160 (4.06)
0.012 (0.305)
0.006 (0.152)
0.096 (2.44)
0.084 (2.13)
0.060 (1.52)
0.030 (0.76)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
0.008 (0.203)
0.004 (0.102)
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
0.220 (5.59)
0.205 (5.21)
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
MURS220
MURS240
MURS260
UNITS
Maximum Recurrent Peak Reverse Voltage
RATINGS
VRRM
200
400
600
Volts
Maximum RMS Voltage
VRMS
140
280
420
Volts
VDC
200
400
600
Volts
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at T A=55 OC
IO
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
I FSM
Operating and Storage Temperature Range
Amps
2.0
40
T J, T STG
Amps
35
0
-55 to + 150
C
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
SYMBOL
MURS220
MURS240
VF
0.95
1.30
Maximum Instantaneous Forward Voltage at 2.0A DC
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@T J = 25 o C
@T J = 150 o C
Maximum Reverse Recovery Time (Note 1)
NOTES : 1. Test Conditions: IF = 0.5A, IR = -1.0A, IRR = -0.25A
2. "Fully ROHS complaint", "100% Sn plating (Pb-free)"
1.45
5
IR
trr
MURS260
Volts
uAmps
150
25
UNITS
50
nSec
2010-02
REV: O
RATING AND CHARACTERISTICS CURVES ( MURS220 THRU MURS260 )
50 W
NONINDUCTIVE
(-)
D.U.T
(+)
25 Vdc
(approx)
(-)
PULSE
GENERATOR
(NOTE 2)
1
NONINDUCTIVE
trr
+0.5A
10 W
NONINDUCTIVE
0
-0.25A
(+)
OSCILLOSCOPE
(NOTE 1)
NOTES: 1 Rise Time = 7ns max. Input Impedance =
1 megohm. 22pF.
-1.0A
2. Rise Time = 10ns max. Source Impedance =
50 ohms.
1cm
SET TIME BASE FOR 15/1 ns/cm
AVERAGE FORWARD CURRENT, (A)
4
3
2
Single Phase
Half Wave 60Hz
Resistive or
Inductive Load
1
0
0
25
50
75
100
125
150
175
INSTANTANEOUS REVERSE CURRENT, (uA)
FIG.1 TEST CIRCUIT DIAGRAM AND REVERSE RECOVERY TIME CHARACTERISTIC
5
1000
TA = 150 OC
100
TA = 75 OC
10
TA = 25 OC
1.0
0.1
0
AMBIENT TEMPERATURE, ( C)
TJ = 25 C
O
3.0
MURS260
1.0
MURS240
0.3
0.1
MURS220
0.03
0.01
Pulse Width=300uS
1% Duty Cycle
0
0.5
1.0
1.5
2.0
2.5
40
60
80
100
120
140
FIG.3 TYPICAL REVERSE
CHARACTERISTICS
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS FORWARD CURRENT, (A)
FIG.2 TYPICAL FORWARD CURRENT
DERATING CURVE
20
10
20
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
O
3.0
3.5
INSTANTANEOUS FORWARD VOLTAGE, (V)
FIG.4 TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
200
8.3ms Single Half Sine-Wave
(JEDED Method)
100
50
30
20
10
1
5
10
50
100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
Mounting Pad Layout
0.106 MAX.
(2.69 MAX.)
0.083MIN.
( 2.10 MIN.)
0.050 MAX.
(1.27 MAX.)
0.220
(5.58) REF
Dimensions in inches and (millimeters)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.