05s2l-05s6l.pdf

SURFACE MOUNT SCHOTTKY BARRIER RECTIFIER
05S2L
THRU
05S6L
VOLTAGE RANGE 20 to 60 Volts CURRENT 0.5 Ampere
FEATURES
*
*
*
*
*
*
*
Low power loss, high efficiency
Low leakage
Low forward voltage
High current capability
High speed switching
High surge capabitity
High reliability
SOD-123FL
.114 (2.9)
MECHANICAL DATA
.106 (2.7)
* Epoxy: Device has UL flammability classification 94V-O
* Mounting position: Any
* Weight: 0.016 gram
.035 (0.90)
.077 (1.95)
.028 (0.70)
.069 (1.75)
.008 (0.20)
.039 (1.00)
.035 (0.90)
.150 (3.8)
.142 (3.6)
.052 (1.32)
.050 (1.28)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
.033 (0.85)
Single phase, half wave, 60 Hz, resistive or inductive load.
.030 (0.75)
.033 (0.85)
.044 (1.12)
.030 (0.75)
.043 (1.08)
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
05S2L
05S3L
05S4L
05S5L
05S6L
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
20
30
40
50
60
Volts
Maximum RMS Voltage
VRMS
14
21
28
35
42
Volts
VDC
20
30
40
50
60
Volts
RATINGS
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
.375” (9.5mm) lead length at T A=55 0C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Junction Capacitance (Note 1)
Typical Thermal Resistance (Note 3)
Operating Temperature Range
Storage Temperature Range
IO
0.5
Amps
I FSM
15
Amps
CJ
110
RqJA
110
0
C/W
RqJL
30
0
C/W
TJ
150
0
C
T STG
-55 to + 150
0
C
pF
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
SYMBOL
Maximum Instantaneous Forward Voltage at 0.5A DC
Maximum Average Reverse Current
@T A = 25 o C
at Rated DC Blocking Voltage
@T A = 100o C
NOTES : 1. Measured at 1 MHz and applied reverse voltage of 4.0 volts.
2. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
3. Thermal Resistance: Mounted on PCB.
VF
IR
05S2L
05S3L
05S4L
.55
05S5L
05S6L
.70
UNITS
Volts
0.2
mAmps
2
mAmps
2006-11
AVERAGE FORWARD CURRENT, (A)
0.5
0.4
0.3
Single
Half Wave 60HZ
Resistive or
Inductive Load
0.375" (9.5mm) Lead Length
0.2
0.1
0
25
50
75
100
125
150
175
INSTANTANEOUS FORWARD CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( 05S2L THRU 05S6L )
20
10
05S2L
05S3L
05S4L
05S5L
05S6L
1.0
0.1
T J = 25 OC
Pulse Width = 300mS
1% Duty Cycle
0.1
O
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
100
05S2L~05S4L
10
TA = 125 OC
1.0
TA = 75 OC
0.1
0.01
0.001
TA = 25 C
O
0
20
40
60
80
100
120
140
0.7
0.9
1.1
1.3 1.5
1.7
1.9
2.1
FIG.2 TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
100
05S5L~05S6L
10
1.0
TA = 125 OC
0.1
TA = 75 OC
0.01
0.001
0
20
TA = 25 OC
40
60
80
100
120
140
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
FIG.3 TYPICAL REVERSE CHARACTERISTICS
PEAK FORWARD SURGE CURRENT, (A)
CT, TOTAL CAPACITANCE, (pF)
0.5
FIG.3 TYPICAL REVERSE CHARACTERISTICS
400
TJ = 25 OC
200
100
80
60
40
20
10
0.3
INSTANTANEOUS FORWARD VOLTAGE, (V)
INSTANTANEOUS REVERSE CURRENT, (mA)
INSTANTANEOUS REVERSE CURRENT, (mA)
AMBIENT TEMPERATURE, ( C)
0.1
0.4
1.0
4
10
40
REVERSE VOLTAGE, (V)
FIG.4 TYPICAL JUNCTION CAPACITANCE
80
25
8.3mS Single Half Sine-Wave
JEDEC Method
20
15
10
5
0
1
2
4
6
8
10
20
40
80 100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT
Mounting Pad Layout
.052 MIN.
(1.32 MIN.)
.033 MIN.
(0.85 MIN.)
.044 MIN.
(1.12 MIN.)
0.165
(4.19) REF
Dimensions in inches and (millimeters)
.033 MIN.
(0.85 MIN.)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.