fm320a-fm3200a.pdf

SURFACE MOUNT SCHOTTKY BARRIER RECTIFIER
FM320A
THRU
FM3200A
VOLTAGE RANGE 20 to 200 Volts CURRENT 3.0 Amperes
FEATURES
*
*
*
*
*
Ideal for surface mounted applications
Low leakage current
Metallurgically bonded construction
Mounting position: Any
Weight: 0.057 gram
DO-214AC
0.067 (1.70 )
0.051 (1.29 )
MECHANICAL DATA
0.110 ( 2.79 )
0.086 ( 2.18 )
* Epoxy: Device has UL flammability classification 94V-O
0.180 ( 4.57 )
0.160 ( 4.06 )
0.012 ( 0.305 )
0.006 ( 0.152 )
0.091 ( 2.31 )
0.067 ( 1.70 )
0.059 ( 1.50 )
0.035 ( 0.89 )
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
0.008 ( 0.203 )
0.004 ( 0.102 )
Ratings at 25 o C ambient temperature unless otherwise specified.
0.209 ( 5.31 )
0.185 ( 4.70 )
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL FM320A FM330A FM340A FM350A FM360A FM380A FM3100A FM3150A FM3200A UNITS
RATINGS
Maximum Recurrent Peak Reverse Voltage
VRRM
20
30
40
50
60
80
100
150
200
Maximum RMS Voltage
VRMS
14
21
28
35
42
56
70
105
140
Volts
VDC
20
30
40
50
60
80
100
150
200
Volts
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at Ambient Temperature
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Thermal Resistance (Note 1)
Volts
IO
3.0
Amps
I FSM
80
Amps
RqJA
55
RqJL
17
0
C/W
Typical Junction Capacitance (Note 2)
CJ
200
pF
Operating Temperature Range
TJ
150
0
C
T STG
-55 to + 150
0
C
Storage Temperature Range
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
SYMBOL FM320A FM330A FM340A FM350A FM360A FM380A FM3100A FM3150A FM3200A UNITS
Maximum Instantaneous Forward Voltage at 3.0A DC
Maximum Average Reverse Current
@T A = 25 o C
at Rated DC Blocking Voltage
@T A = 100 o C
VF
IR
NOTES : 1. Thermal Resistance : Mounted on PCB.
2. Measured at 1 MHz and applied reverse voltage of 4.0 volts.
3. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
.55
.75
.85
0.2
2
Volts
mA
mA
2007-08
INSTANTANEOUS REVERSE CURRENT, (mA)
3.0
FM3
2.5
~F M
32
P.C.B. Mounted on
0.4X0.4"(10 X10mm)
copper pad areas
M3
0A
~F
320
0A
1.5
50A
2.0
FM
40
A
AVERAGE FORWARD CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( FM320A THRU FM3200A )
1.0
Single Phase Half Wave 60Hz
Resistive or Inductive Load
0.375" (9.5mm) Lead Length
0.5
0
0
25
50
75
100
125
150
10
TA = 100 OC
1.0
0.1
0.01
FM320A~FM340A
FM350A~FM360A
FM380A~FM3200A
0.001
0
20
O
CJ, JUNCTION CAPACITANCE, (pF)
10
FM320A~FM340A
FM380A~FM3200A
1.0
FM350A~FM360A
TJ = 25 C
Pulse width=300mS
1% Duty Cycle
O
0.1
0.2
0.3
0.4
0.5
0.6
0.7
40
60
100
120
140
0.8
FIG.2 TYPICAL REVERSE
CHARACTERISTICS
500
TJ = 25 OC
200
100
50
20
10
5
0.9
0.1
0.2
INSTANTANEOUS FORWARD VOLTAGE, (V)
0.5
1
2
5
10
20
REVERSE VOLTAGE, (V)
FIG.3 TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
FIG.4 TYPICAL JUNCTION CAPACITANCE
80
At rated TL
8.3mS Single Half Sine-Wave
JEDEC Method
70
60
50
40
30
20
10
1
80
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS FORWARD CURRENT, (A)
AMBIENT TEMPERATURE, ( C)
20
TA = 75 OC
TA = 25 OC
2
5
10
20
50
100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
40
Mounting Pad Layout
0.094 MAX.
(2.38 MAX.)
0.060MIN.
( 1.52 MIN.)
0.052 MAX.
(1.32 MAX.)
0.220
(5.58) REF
Dimensions in inches and (millimeters)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.