www.altechcorp.com/test-equipment/PDFs/TestMeasurement28.pdf

Measuring Leads
2 mm System
MVL 2/25; MVL 2/50; MVL 2/100
Type
Injection-moulded measuring lead, at
either end 2 mm diameter nickelplated brass connector and 2 mm
diameter socket with contact spring,
for tower constructions. Highly
flexible stranded lead, grip and lead
shatter-proof.
MAL S WS 2-4 100/1
Safety measuring lead according to IEC
61010, one end with 2 mm safety plug and
other end with 4 mm safety plug, as well
as 2 mm and 4 mm socket for onward
connection capability. Gold-plated / nickelplated copper-beryllium contact spring.
Highly flexible, double insulated stranded
lead and shatter-proof grip sleeves. Built in
colour indicator for easy identification of
insulation damages.
Cable length
0.25m (9.8”), 0.5m (19.7”), 1.0m (39.4”)
100 m (39.4”)
Cable size
0.5 mm2 (20AWG)
1 mm2 (18 AWG)
Cable material
PVC
PVC
Pin dimensions
2 mm (0.078”)
2 mm (0.078”) / 4 mm (0.157”)
Cable type
LF-Y
PART NO. / Housing color
LEH-XY
0.25 m 973594100
0.5 m 973595100
973594101
975163100
975163105
973595101
975163101
975163106
1.0 m 973596100
973596101
975163102
975163107
975163103
975163109
975163104
Technical Data
Contact Type
stationary pin
spring-loaded pin
Voltage Rating
30 VAC / 60 VDC
CAT I
AC/DC 1000V
CAT II
6A
26 mOhm
10 A
21 mOhm
Contact Pin
nickel plated brass
nickel plated brass
Contact Spring
copper beryllium
gold plated copper beryllium
Polypropylene
Polyamide
-40 °C to +60 °C (-40°F to 140°F)
-15 °C to +70 °C (5°F to 158°F)
UL 94 HB
UL 94 V-2
Measurement Category (IEC61010)
Current Rating*
Contact Resistance
Material Specifications
Housing
Environmental Conditions
Temperature Range
Flamability Rating
Housing
Drawing
Measurements are shown in millimeters.
Multiply by 0.03937 to convert to inches.
Socket for 2 mm plug
ø2
12
L
18
23,5
ø4
ø 7,8
ø4
ø 2,8
9
ø2
ø2
ø2
Socket for 2 mm plug
L
38,5
20
32
* Please consider derating graph on page 80.