Express5800/R120g-2M - May 17, 2016

NEC Express5800/R120g-2M
System Configuration Guide
Introduction
This document contains product and configuration information that will enable you to configure your system. The
guide will ensure fast and proper configuration of your NEC Express5800 server.
May 17, 2016
Revision 1.1
NEC Corporation
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Contents
TECHNICAL SPECIFICATION ........................................................................................ 3
Key Features .......................................................................................................................................... 3
Specification .......................................................................................................................................... 3
EXTERNAL VIEWS ....................................................................................................... 10
Front and Rear Views ......................................................................................................................... 10
Dimensions (mm) ................................................................................................................................ 12
CONFIGURATION DIAGRAM ....................................................................................... 13
Expansion Slots .................................................................................................................................. 14
SERVER CONFIGURATION ......................................................................................... 15
1
2
3
Base Models ................................................................................................................................. 15
Processors and Heat Sink .......................................................................................................... 15
Memory ......................................................................................................................................... 17
3.1
Memory Configuration........................................................................................................ 17
4 Internal Hard Disk Drives ............................................................................................................ 20
4.1
RAID Configuration ............................................................................................................ 20
4.2
Required Components for RAID Configuration ................................................................. 21
4.3
Supported HDD/SDD ......................................................................................................... 23
5 2.5-inch PCIe SSD ........................................................................................................................ 25
5.1
2.5-inch PCIeSSD Installation Kit ...................................................................................... 25
5.2
PCIe SSD ........................................................................................................................... 26
6 Optical Drive ................................................................................................................................. 26
7 Internal RDX Drive ....................................................................................................................... 26
7.1
RDX Configuration ............................................................................................................. 26
8 PCI Riser Card / PCI Card ........................................................................................................... 27
8.1
PCI Riser Card ................................................................................................................... 27
8.2
Full Length PCI Card installation Kit .................................................................................. 27
8.3
Graphics Card Installation Kit ............................................................................................ 27
8.4
Network Interface Controller .............................................................................................. 28
8.5
InfiniBand ........................................................................................................................... 30
8.6
External Storage Controller ............................................................................................... 31
8.7
Serial Port Adapter ............................................................................................................. 31
9 Other Add-in Components .......................................................................................................... 32
9.1
Power Supply Module ........................................................................................................ 32
9.2
Redundant Fan Kit ............................................................................................................. 32
9.3
Trusted Platform Module Kit .............................................................................................. 32
9.4
Internal Flash Memory ....................................................................................................... 32
9.5
High Temperature Support Option ..................................................................................... 33
9.6
Flash FDD .......................................................................................................................... 33
10 Add-on Components .................................................................................................................. 34
10.1 17-inch LCD Console Drawer ............................................................................................ 34
10.2 KVM Switch ........................................................................................................................ 34
10.3 Cable Management Arm .................................................................................................... 35
10.4 Server Management License ............................................................................................. 35
10.5 Medium and Cartridge ....................................................................................................... 35
REFERENCES............................................................................................................... 36
Boot Mode Setting .............................................................................................................................. 36
NEC Corporation
Revision 1.1 – May, 2016
2
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Server Management ............................................................................................................................ 37
Endurance of SSD ............................................................................................................................... 38
OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 39
Supported PCI Cards and Installable Slots ...................................................................................... 40
Copyright Notice and Liability Disclaimer ........................................................................................ 48
REVISION HISTORY ..................................................................................................... 49
Technical Specification
Key Features




High performance with the latest Intel® Xeon® processor E5-2600 v4 product family
Up to 1.5 TB of high speed DDR4 memory
High energy efficiency with power capping feature and 80 PLUS® Platinum power supply
Full manageability by integrated EXPRESSSCOPE Engine 3
Specification
(1 / 4)
Model
Part Number
Processor
R120g-2M
Type
Clock speed
Number of Processors
Cache
Cores and Threads
Chipset
Memory
Type
Standard Capacity
Maximum Capacity
Memory protection
Internal Storage
Standard Capacity
Maximum Capacity
Disk Controller
RAID
Hot Plug
Optical Disk Drive
Optical Drive Bays
3.5-inch Media Bays
Disk Drive Bays
NEC Corporation
N8100-2420F, N8100-2421F, N8100-2422F, N8100-2423F
Intel® Xeon® Intel® Xeon® Intel® Xeon® Intel® Xeon®
processor
processor
processor
processor
E5-2603 V4
E5-2620 V4
E5-2623 v4
E5-2630 v4
1.70 GHz
2.10 GHz
2.60 GHz
2.20 GHz
1 to 2
15 MB
20 MB
10 MB
25 MB
6C-12T
8C-16T
4C-8T
10C-20T
Intel® C612 Chipset
DDR4-2400 Registered DIMM (4/8/16/32GB)
DDR4-2400 TSV Registered DIMM (64GB)
0 GB
1.5 TB (24 x 64 GB)
ECC, x4 SDDC, Memory Mirroring, Memory Lockstep, Memory
Sparing
0 GB
SAS HDD : 28.8 TB (16 x 1.8 TB)
SATA HDD : 32 TB (16 x 2 TB)
SAS SSD : 6.4 TB ( 16 x 400 GB)
SATA SSD : 25.6 TB ( 16 x 1.6 TB)
SATA : 6Gb/s (Integrated)
SAS: 12 Gb/s (Optional)
SATA : RAID 0/1/5/6/10/50/60 (Optional)
SAS : RAID 0/1/5/6/10/50/60 (Optional)
Supported
Optional
1
1
1
16
Revision 1.1 – May, 2016
3
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Model
R120g-2M
Expansion Slots
Standard
Video
Controller (VRAM)
Resolution / Color
Interfaces
Server Management
Redundant Fan
Redundant Power Supply
Power Supply
Power
Consumption
(Max. Config, Idling)
(Max. Config,
Operating)
Acoustical Noise
Max. Config, Idling
(Sound Pressure
Max. Config, Operating
5
Level)
Dimensions (W x D x H )
Weight (Minimum / Maximum)
Temperature, Relative Humidity
(non-condensing)
Regulatory and Safety
Operating Systems
1
2
3
4
5
6
Total: 8 slots available
2 PCIe 3.0 x8 (x8 connector)
2
4 PCIe 3.0 x8 (x8 connector)
1 PCIe 3.0 x8 (x8 connector) flexible LOM slot
1 PCIe 3.0 x8 (x8 connector) dedicated RAID slot
* The slot mix changes by installing an optional riser card.
Integrated in Server Management Controller (32MB)
3
1600 x 1200 / 16.7M
2 x VGA (15-pin mini D-sub, 1 x front, 1 x rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2rear)
5 x USB3.0 (2 x front, 2 x rear, 1 x internal)
3 x USB2.0 (2 x rear, 1 x internal)
1 x Flexible Integrated NIC (4x 1000BASE-T, 2x 10GBASE-T, or
2x 1000BASE-T + 2x 10GBASE-SFP+)
1 x Management LAN connector (1000BASE-T, RJ-45, 1 x rear)
EXPRESSSCOPE Engine 3
4
Standard (N+1) , Optional kit for N+N redundancy, hot plug
Optional, hot plug
1 to 2 x 460 Watt or 800 Watt or 1000 Watt 80 PLUS® Platinum
certified hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz, or
800 Watt 80 PLUS® Titanium certified hot plug PSU
200-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
335 VA /
336 VA /
332 VA /
355 VA /
333 Watt
334 Watt
330 Watt
352 Watt
710 VA /
738 VA /
790 VA /
831 VA /
705 Watt
733 Watt
785 Watt
825 Watt
49.6dB
54.0dB
448.0 x 735.8 x 87.2 mm / 17.6 x 28.9 x 3.4 in (2U)
19.7 kg / 32.3 kg, 43.43 lbs. / 71.21 lbs.
Operating: 5° to 40° C / 41° to 104° F (Standard)
or 5° to 45° C / 41° to 113° F (Optional), 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
FCC, UL, CB, CE, BSMI, UL(Mexico), KC, CCC, RCM, BIS,
RoHS, WEEE
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Datacenter
6
Red Hat Enterprise Linux 6.7 or later (x86_64)
6
Red Hat Enterprise Linux 7.2 or later
VMware ESXi™ 5.5 Update 3
VMware ESXi™ 6.0 Update 1
An optional drive cage is required to install more than 8 hard drives.
Available only when the second processor is configured.
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
Redundant at ambient temperatures up to 35° C.
Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating
environment.
For Linux support, contact our sales representative or go to the NEC website at:
http://www.nec.com/global/prod/express/linux/index.html
NEC Corporation
Revision 1.1 – May, 2016
4
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
(2 / 4)
Model
Part Number
Processor
R120g-2M
Type
Clock speed
Number of Processors
Cache
Cores and Threads
Chipset
Memory
Type
Standard Capacity
Maximum Capacity
Memory protection
Internal Storage
Standard Capacity
Maximum Capacity
Disk Controller
RAID
Expansion Slots
Video
Hot Plug
Optical Disk Drive
Optical Drive Bays
3.5-inch Media Bays
Disk Drive Bays
Standard
Controller (VRAM)
Resolution / Color
Interfaces
Server Management
Redundant Fan
Redundant Power Supply
Power Supply
NEC Corporation
N8100-2420F, N8100-2421F, N8100-2422F, N8100-2423F
Intel® Xeon® Intel® Xeon® Intel® Xeon® Intel® Xeon®
processor
processor
processor
processor
E5-2637 V4
E5-2640 V4
E5-2643 v4
E5-2650 v4
3.50 GHz
2.40 GHz
3.40 GHz
2.20 GHz
1 to 2
15 MB
25 MB
20 MB
30 MB
4C-8T
10C-20T
6C-12T
12C-24T
Intel® C612 Chipset
DDR4-2400 Registered DIMM (4/8/16/32GB)
DDR4-2400 TSV Registered DIMM (64GB)
0 GB
1.5 TB (24 x 64 GB)
ECC, x4 SDDC, Memory Mirroring, Memory Lockstep, Memory
Sparing
0 GB
SAS HDD : 28.8 TB (16 x 1.8 TB)
SATA HDD : 32 TB (16 x 2 TB)
SAS SSD : 6.4 TB ( 16 x 400 GB)
SATA SSD : 25.6 TB ( 16 x 1.6 TB)
SATA : 6Gb/s (Integrated)
SAS: 12 Gb/s (Optional)
SATA : RAID 0/1/5/6/10/50/60 (Optional)
SAS : RAID 0/1/5/6/10/50/60 (Optional)
Supported
Optional
1
1
1
16
Total: 8 slots available
2 PCIe 3.0 x8 (x8 connector)
2
4 PCIe 3.0 x8 (x8 connector)
1 PCIe 3.0 x8 (x8 connector) flexible LOM slot
1 PCIe 3.0 x8 (x8 connector) dedicated RAID slot
* The slot mix changes by installing an optional riser card.
Integrated in Server Management Controller (32MB)
3
1600 x 1200 / 16.7M
2 x VGA (15-pin mini D-sub, 1 x front, 1 x rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2rear)
5 x USB3.0 (2 x front, 2 x rear, 1 x internal)
3 x USB2.0 (2 x rear, 1 x internal)
1 x Flexible Integrated NIC (4x 1000BASE-T, 2x 10GBASE-T, or
2x 1000BASE-T + 2x 10GBASE-SFP+)
1 x Management LAN connector (1000BASE-T, RJ-45, 1 x rear)
EXPRESSSCOPE Engine 3
4
Standard (N+1) , Optional kit for N+N redundancy, hot plug
Optional, hot plug
1 to 2 x 460 Watt or 800 Watt or 1000 Watt 80 PLUS® Platinum
certified hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz, or
800 Watt 80 PLUS® Titanium certified hot plug PSU
200-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Revision 1.1 – May, 2016
5
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Model
Power
Consumption
R120g-2M
(Max. Config, Idling)
(Max. Config,
Operating)
Acoustical Noise
Max. Config, Idling
(Sound Pressure
Max. Config, Operating
5
Level)
Dimensions (W x D x H )
Weight (Minimum / Maximum)
Temperature, Relative Humidity
(non-condensing)
Regulatory and Safety
Operating Systems
1
2
3
4
5
6
365 VA /
362 Watt
876 VA /
870 Watt
49.6dB
57.7dB
333 VA /
330 Watt
809 VA /
803 Watt
49.6dB
54.4dB
364 VA /
361 Watt
988 VA /
981 Watt
49.6dB
57.7dB
332 VA /
330 Watt
876 VA /
870 Watt
49.6dB
55.6dB
448.0 x 735.8 x 87.2 mm / 17.6 x 28.9 x 3.4 in (2U)
19.7 kg / 32.3 kg, 43.43 lbs. / 71.21 lbs.
Operating: 5° to 40° C / 41° to 104° F (Standard)
or 5° to 45° C / 41° to 113° F (Optional), 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
FCC, UL, CB, CE, BSMI, UL(Mexico), KC, CCC, RCM, BIS,
RoHS, WEEE
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Datacenter
6
Red Hat Enterprise Linux 6.7 or later (x86_64)
6
Red Hat Enterprise Linux 7.2 or later
VMware ESXi™ 5.5 Update 3
VMware ESXi™ 6.0 Update 1
An optional drive cage is required to install more than 8 hard drives.
Available only when the second processor is configured.
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
Redundant at ambient temperatures up to 35° C.
Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating
environment.
For Linux support, contact our sales representative or go to the NEC website at:
http://www.nec.com/global/prod/express/linux/index.html
(3 / 4)
Model
Part Number
Processor
R120g-2M
Type
Clock speed
Number of Processors
Cache
Cores and Threads
Chipset
Memory
Type
Standard Capacity
Maximum Capacity
Memory protection
Internal Storage
NEC Corporation
Standard Capacity
Maximum Capacity
N8100-2420F, N8100-2421F, N8100-2422F, N8100-2423F
Intel® Xeon® Intel® Xeon® Intel® Xeon® Intel® Xeon®
processor
processor
processor
processor
E5-2667 V4
E5-2680 V4
E5-2690 v4
E5-2697 v4
3.20 GHz
2.40 GHz
2.60 GHz
2.30 GHz
1 to 2
25 MB
35 MB
45 MB
8C-16T
14C-28T
18C-36T
Intel® C612 Chipset
DDR4-2400 Registered DIMM (4/8/16/32GB)
DDR4-2400 TSV Registered DIMM (64GB)
0 GB
1.5 TB (24 x 64 GB)
ECC, x4 SDDC, Memory Mirroring, Memory Lockstep, Memory
Sparing
0 GB
SAS HDD : 28.8 TB (16 x 1.8 TB)
SATA HDD : 32 TB (16 x 2 TB)
SAS SSD : 6.4 TB ( 16 x 400 GB)
SATA SSD : 25.6 TB ( 16 x 1.6 TB)
Revision 1.1 – May, 2016
6
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Model
Internal Storage
(cont’d)
R120g-2M
Disk Controller
RAID
Expansion Slots
Video
Hot Plug
Optical Disk Drive
Optical Drive Bays
3.5-inch Media Bays
Disk Drive Bays
Standard
Controller (VRAM)
Resolution / Color
Interfaces
Server Management
Redundant Fan
Redundant Power Supply
Power Supply
Power
Consumption
(Max. Config, Idling)
(Max. Config,
Operating)
Acoustical Noise
Max. Config, Idling
(Sound Pressure
Max. Config, Operating
5
Level)
Dimensions (W x D x H )
Weight (Minimum / Maximum)
Temperature, Relative Humidity
(non-condensing)
Regulatory and Safety
Operating Systems
1
2
SATA : 6Gb/s (Integrated)
SAS: 12 Gb/s (Optional)
SATA : RAID 0/1/5/6/10/50/60 (Optional)
SAS : RAID 0/1/5/6/10/50/60 (Optional)
Supported
Optional
1
1
1
16
Total: 8 slots available
2 PCIe 3.0 x8 (x8 connector)
2
4 PCIe 3.0 x8 (x8 connector)
1 PCIe 3.0 x8 (x8 connector) flexible LOM slot
1 PCIe 3.0 x8 (x8 connector) dedicated RAID slot
* The slot mix changes by installing an optional riser card.
Integrated in Server Management Controller (32MB)
3
1600 x 1200 / 16.7M
2 x VGA (15-pin mini D-sub, 1 x front, 1 x rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2rear)
5 x USB3.0 (2 x front, 2 x rear, 1 x internal)
3 x USB2.0 (2 x rear, 1 x internal)
1 x Flexible Integrated NIC (4x 1000BASE-T, 2x 10GBASE-T, or
2x 1000BASE-T + 2x 10GBASE-SFP+)
1 x Management LAN connector (1000BASE-T, RJ-45, 1 x rear)
EXPRESSSCOPE Engine 3
4
Standard (N+1) , Optional kit for N+N redundancy, hot plug
Optional, hot plug
1 to 2 x 460 Watt or 800 Watt or 1000 Watt 80 PLUS® Platinum
certified hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz, or
800 Watt 80 PLUS® Titanium certified hot plug PSU
200-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
362 VA /
336 VA /
362 VA /
368 VA /
360 Watt
334 Watt
360 Watt
365 Watt
984 VA /
963 VA /
987 VA /
994 VA /
977 Watt
957 Watt
980 Watt
987 Watt
49.6dB
49.6dB
49.6dB
49.6dB
57.7dB
56.6dB
57.7dB
58.3dB
448.0 x 735.8 x 87.2 mm / 17.6 x 28.9 x 3.4 in (2U)
19.7 kg / 32.3 kg, 43.43 lbs. / 71.21 lbs.
Operating: 5° to 40° C / 41° to 104° F (Standard)
or 5° to 45° C / 41° to 113° F (Optional), 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
FCC, UL, CB, CE, BSMI, UL(Mexico), KC, CCC, RCM, BIS,
RoHS, WEEE
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Datacenter
6
Red Hat Enterprise Linux 6.7 or later (x86_64)
6
Red Hat Enterprise Linux 7.2 or later
VMware ESXi™ 5.5 Update 3
VMware ESXi™ 6.0 Update 1
An optional drive cage is required to install more than 8 hard drives.
Available only when the second processor is configured.
NEC Corporation
Revision 1.1 – May, 2016
7
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
3
4
5
6
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
Redundant at ambient temperatures up to 35° C.
Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating
environment.
For Linux support, contact our sales representative or go to the NEC website at:
http://www.nec.com/global/prod/express/linux/index.html
(4 / 4)
Model
R120g-2M
Part Number
Processor
N8100-2420F, N8100-2421F, N8100-2422F, N8100-2423F
Intel® Xeon®
Intel® Xeon®
Intel® Xeon®
processor
processor E5-2698
processor E5-2699
E5-2697A V4
V4
v4
2.60 GHz
2.20 GHz
2.20 GHz
1 to 2
40 MB
50 MB
55 MB
16C-32T
20C-40T
22C-44T
Intel® C612 Chipset
DDR4-2400 Registered DIMM (4/8/16/32GB)
DDR4-2400 TSV Registered DIMM (64GB)
0 GB
1.5 TB (24 x 64 GB)
ECC, x4 SDDC, Memory Mirroring, Memory Lockstep, Memory
Sparing
0 GB
SAS HDD : 28.8 TB (16 x 1.8 TB)
SATA HDD : 32 TB (16 x 2 TB)
SAS SSD : 6.4 TB ( 16 x 400 GB)
SATA SSD : 25.6 TB ( 16 x 1.6 TB)
SATA : 6Gb/s (Integrated)
SAS: 12 Gb/s (Optional)
SATA : RAID 0/1/5/6/10/50/60 (Optional)
SAS : RAID 0/1/5/6/10/50/60 (Optional)
Supported
Optional
1
1
1
16
Total: 8 slots available
2 PCIe 3.0 x8 (x8 connector)
2
4 PCIe 3.0 x8 (x8 connector)
1 PCIe 3.0 x8 (x8 connector) flexible LOM slot
1 PCIe 3.0 x8 (x8 connector) dedicated RAID slot
* The slot mix changes by installing an optional riser card.
Integrated in Server Management Controller (32MB)
3
1600 x 1200 / 16.7M
2 x VGA (15-pin mini D-sub, 1 x front, 1 x rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2rear)
5 x USB3.0 (2 x front, 2 x rear, 1 x internal)
3 x USB2.0 (2 x rear, 1 x internal)
1 x Flexible Integrated NIC (4x 1000BASE-T, 2x 10GBASE-T, or
2x 1000BASE-T + 2x 10GBASE-SFP+)
1 x Management LAN connector (1000BASE-T, RJ-45, 1 x rear)
EXPRESSSCOPE Engine 3
4
Standard (N+1) , Optional kit for N+N redundancy, hot plug
Optional, hot plug
Type
Clock speed
Number of Processors
Cache
Cores and Threads
Chipset
Memory
Type
Standard Capacity
Maximum Capacity
Memory protection
Internal Storage
Standard Capacity
Maximum Capacity
Disk Controller
RAID
Expansion Slots
Video
Hot Plug
Optical Disk Drive
Optical Drive Bays
3.5-inch Media Bays
Disk Drive Bays
Standard
Controller (VRAM)
Resolution / Color
Interfaces
Server Management
Redundant Fan
Redundant Power Supply
NEC Corporation
Revision 1.1 – May, 2016
8
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Model
R120g-2M
Power Supply
1 to 2 x 460 Watt or 800 Watt or 1000 Watt 80 PLUS® Platinum
certified hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz, or
800 Watt 80 PLUS® Titanium certified hot plug PSU
200-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
364 VA /
364 VA /
364 VA /
362 Watt
362 Watt
362 Watt
996 VA /
996 VA /
996 VA /
989 Watt
989 Watt
989 Watt
49.6dB
49.6dB
49.6dB
58.3dB
57.7dB
58.3dB
Power
Consumption
(Max. Config, Idling)
(Max. Config,
Operating)
Acoustical Noise
Max. Config, Idling
(Sound Pressure
Max. Config, Operating
5
Level)
Dimensions (W x D x H )
Weight (Minimum / Maximum)
Temperature, Relative Humidity
(non-condensing)
Regulatory and Safety
Operating Systems
1
2
3
4
5
6
448.0 x 735.8 x 87.2 mm / 17.6 x 28.9 x 3.4 in (2U)
19.7 kg / 32.3 kg, 43.43 lbs. / 71.21 lbs.
Operating: 5° to 40° C / 41° to 104° F (Standard)
or 5° to 45° C / 41° to 113° F (Optional), 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
FCC, UL, CB, CE, BSMI, UL(Mexico), KC, CCC, RCM, BIS,
RoHS, WEEE
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Datacenter
6
Red Hat Enterprise Linux 6.7 or later (x86_64)
6
Red Hat Enterprise Linux 7.2 or later
VMware ESXi™ 5.5 Update 3
VMware ESXi™ 6.0 Update 1
An optional drive cage is required to install more than 8 hard drives.
Available only when the second processor is configured.
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
Redundant at ambient temperatures up to 35° C.
Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating
environment.
For Linux support, contact our sales representative or go to the NEC website at:
http://www.nec.com/global/prod/express/linux/index.html
NEC Corporation
Revision 1.1 – May, 2016
9
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
External Views
Front and Rear Views
Front View
C D E
A
F H I J K MN O P
B
G
Q
L
R
S
Legend
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
2.5-inch Drive Bays
2.5-inch Drive Cage Bay
Power Button / Power LED
UID LED Button
System Reset Button
Dump (NMI) Button
USB Connectors
BMC Reset Button
System Status LED 1
System Status LED 2
NEC Corporation
K.
L.
M.
N.
O.
P.
Q.
R.
S.
Power Capping LED
VGA Connector
Data LAN 1 Activity LED
Data LAN 2 Activity LED
Data LAN 3 Activity LED
Data LAN 4 Activity LED
Media Bay
Optical Drive Bay
Pull-out Tab
Revision 1.1 – May, 2016
10
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Rear View
B
A
C
D E
F
G
H
I
J
K
L
Legend
A.
B.
C.
D.
E.
F.
PCI Slots (Full-Height)
PCI Slots (Low-Profile)
Power Supply
AC Inlet
AC Power LED
USB Connectors
NEC Corporation
G.
H.
I.
J.
K.
L.
UID Button/LED
Serial Port Connector
VGA Connector
Management LAN Connector
LOM Card Slot
Additional Power Supply Slot
Revision 1.1 – May, 2016
11
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Dimensions (mm)
Without Cable Arm
87.4
32.7
829.0
88.3
735.8
87.2
482.0
448.0
482.6
With Cable Arm
948.4
867.0
NEC Corporation
Revision 1.1 – May, 2016
12
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Configuration Diagram
NEC Corporation
CPU 2
Standard Components
PSU
2
LOM
#1D
#1C
PCIe 3.0
RAID Slot
6x DIMM Slots
Hot Plug
Power Supply 1
PSU
1
Cooling
Fan
(CPU2)
PCI Riser
#2C
6x DIMM Slots
PCIe 3.0
#3D
#2D
2xDIMM
6x DIMM Slots
LOM
Card
#3C
Cooling Fan
Optical Drive Bay
Media Bay
Legend:
Redundant Cooling Fan
8x 2.5-inch
Drives
Optical Driver
Bay /
Media Bay
CPU 1
4x Flash Backup Unit Slots
8x 2.5-inch
Drives
2.5-inch
Hot Plug
Drive Cage
2.5-inch
Hot Plug
Drive Cage
Hot Plug
Power Supply 2
6x DIMM Slots
Mandatory components
Revision 1.1 – May, 2016
13
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Expansion Slots
Slot #1A
Slot #3C
Slot #3D
Slot #2C
Slot #2D
Slot #1C
Slot #1D
Slot #1B
Legend
Standard
Remarks
#1A
#1B
#1C
#2C
#3C
N8116-34/-34A
PCIe x16 Riser
Card Kit
N8116-45
PCIe x4/x16 FH
Riser Card Kit
#1D
#2D
#3D
#1A
#1B
#1C
#2C
#1D
#2D
#3D
#1A
#1B
#1C
#2C
#3C
N8116-49
PCIe x4/x16 FH/LP
Riser Card Kit
or
N8116-45
PCIe x4/x16 FH
Riser Card Kit and
N8116-46
PCIe x4/x16 LP
Riser Card Kit
#1D
#2D
#3D
#1A
#1B
#1C
#2C
#3C
#1D
#2D
#3D
PCIe 3.0 x8, x8 connector, for a dedicated RAID controller
PCIe 3.0 x8, x8 connector, for a dedicated LOM Card
PCIe 3.0 x8, x8 connector, Full-height, up to 220 mm length
PCIe 3.0 x8, x8 connector, Full-height, up to 220/312 mm
length
PCIe 3.0 x8, x8 connector, Full-height, up to 220/312 mm
length
PCIe 3.0 x8, x8 connector, Low-profile, up to 220 mm length
PCIe 3.0 x8, x8 connector, Low-profile, up to 220 mm length
PCIe 3.0 x8, x8 connector, Low-profile, up to 220 mm length
PCIe 3.0 x8, x8 connector, for a dedicated RAID controller
PCIe 3.0 x8, x8 connector, for a dedicated LOM Card
PCIe 3.0 x8, x16 connector, Full-height, up to 220 mm length
PCIe 3.0 x16, x16 connector, Full-height, up to 220/312 mm
length
PCIe 3.0 x8, x8 connector, Low-profile, up to 220 mm length
PCIe 3.0 x8, x8 connector, Low-profile, up to 220 mm length
PCIe 3.0 x8, x8 connector, Low-profile, up to 220 mm length
PCIe 3.0 x8, x8 connector, for a dedicated RAID controller
PCIe 3.0 x8, x8 connector, for a dedicated LOM Card
PCIe 3.0 x4, x8 connector, Full-height, up to 220 mm length
PCIe 3.0 x4, x8 connector, Full-height, up to 220/312 mm
length
PCIe 3.0 x16, x16 connector, Full-height, up to 312 mm
length
PCIe 3.0 x8, x8 connector, Low-profile, up to 220 mm length
PCIe 3.0 x8, x8 connector, Low-profile, up to 220 mm length
PCIe 3.0 x8, x8 connector, Low-profile, up to 220 mm length
PCIe 3.0 x8, x8 connector, for a dedicated RAID controller
PCIe 3.0 x8, x8 connector, for a dedicated LOM Card
PCIe 3.0 x4, x8 connector, Full-height, up to 220 mm length
PCIe 3.0 x4, x8 connector, Full-height, up to 220/312 mm
length
PCIe 3.0 x16, x16 connector, Full-height, up to 312 mm
length
PCIe 3.0 x4, x8 connector, Low-profile, up to 220 mm length
PCIe 3.0 x4, x8 connector, Low-profile, up to 220 mm length
PCIe 3.0 x16, x16 connector, Low-profile, up to 220 mm
length
2CPU required
2CPU required
2CPU required
2CPU required
2CPU required
2CPU required
2CPU required
2CPU required
2CPU required
2CPU required
2CPU required
2CPU required
NOTE:


Up to 312 mm length card can be installed into slot #2C when N8116-37 Full Length PCI Card
installation Kit is installed.
The slot #3C is not available when using N8116-34/34A PCIe x16 Riser Card Kit.
NEC Corporation
Revision 1.1 – May, 2016
14
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Server Configuration
1 Base Models
Product Name / Description
Part Number
NEC Express5800/R120g-2M Server
no processor, no RAM, no HDD, no ODD, no LOM Card
Including : 1 x 460 Watt 80 PLUS® Platinum Power Supply Unit, Front Bezel, 2.5-inch
Drive Cage
NEC Express5800/R120g-2M Server
no processor, no RAM, no HDD, no ODD, no LOM Card
Including : 1 x 800 Watt 80 PLUS® Platinum Power Supply Unit, Front Bezel, 2.5-inch
Drive Cage
NEC Express5800/R120g-2M Server
no processor, no RAM, no HDD, no ODD, no LOM Card
Including : 1 x 800 Watt 80 PLUS® Titanium Power Supply Unit, Front Bezel, 2.5-inch
Drive Cage
NEC Express5800/R120g-2M Server
no processor, no RAM, no HDD, no ODD, no LOM Card
Including : 1 x 1000 Watt 80 PLUS® Platinum Power Supply Unit, Front Bezel, 2.5-inch
Drive Cage
N8100-2420F
N8100-2421F
N8100-2422F
N8100-2423F
NOTE:


The base model must be ordered with a processor kit, a memory kit, and LOM card.
Use the NEC Power Supply Selector to select appropriate size for power units. For details, please
visit the NEC website at:
http://www.nec.com/en/global/prod/express/collateral/tools/PowerSelector_G01.xls
2 Processors and Heat Sink
Available sockets: 2
Product Name / Description
Part Number
Processors
1 Processor
Required
N8101-1029F
NEC Corporation
Xeon E5-2603 v4 Processor Kit
Intel® Xeon ® Processor E5-2603v4 (1.70 GHz, 6C/6T, 15 MB)
Xeon E5-2620 v4 Processor Kit
Intel® Xeon ® Processor E5-2620 v4 (2.10 GHz, 8C/16T, 20 MB)
Xeon E5-2623 v4 Processor Kit
Intel® Xeon ® Processor E5-2623 v4 (2.60 GHz, 4C/8T, 10 MB)
Xeon E5-2630 v4 Processor Kit
Intel® Xeon ® Processor E5-2630 v4 (2.20 GHz, 10C/20T, 25 MB)
Xeon E5-2637 v4 Processor Kit
Intel® Xeon ® Processor E5-2637 v4 (3.50 GHz, 4C/8T, 15 MB)
Xeon E5-2640 v4 Processor Kit
Intel® Xeon ® Processor E5-2640 v4 (2.40 GHz, 10C/20T, 25 MB)
Xeon E5-2643 v4 Processor Kit
Intel® Xeon ® Processor E5-2643 v4 (3.40 GHz, 6C/12T, 20 MB)
Xeon E5-2650 v4 Processor Kit
Intel® Xeon ® Processor E5-2650 v4 (2.20 GHz, 12C/24T, 30 MB)
Xeon E5-2667 v4 Processor Kit
Intel® Xeon ® Processor E5-2667 v4 (3.20 GHz, 8C/16T, 25 MB)
Xeon E5-2680 v4 Processor Kit
Intel® Xeon ® Processor E5-2680 v4 (2.40 GHz, 14C/28T, 35 MB)
Xeon E5-2690 v4 Processor Kit
Intel® Xeon ® Processor E5-2690 v4 (2.60 GHz, 14C/28T, 35 MB)
Xeon E5-2697 v4 Processor Kit
Intel® Xeon ® Processor E5-2697 v4 (2.30 GHz, 18C/36T, 45 MB)
Revision 1.1 – May, 2016
N8101-1030F
N8101-1031F
N8101-1032F
N8101-1033F
N8101-1034F
N8101-1035F
N8101-1036F
N8101-1038F
N8101-1039F
N8101-1040F
N8101-1041F
15
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Heat Sink
1st
2nd
Xeon E5-2697A v4 Processor Kit
Intel® Xeon ® Processor E5-2697A v4(2.60 GHz,16C/32T, 40
MB)
Xeon E5-2698 v4 Processor Kit
Intel® Xeon ® Processor E5-2698 v4 (2.20 GHz, 20C/40T, 50 MB)
Xeon E5-2699 v4 Processor Kit
Intel® Xeon ® Processor E5-2699 v4 (2.20 GHz, 22C/44T, 55 MB)
Processor Heat Sink
st
For 1 Processor
Processor Heat Sink
nd
For 2 Processor, including cooling fan kit
N8101-1042F
N8101-1043F
N8101-1044F
(Standard)
N8101-781F
NOTE:

Minimum one processor kit from above must be installed.

The processors must be the same to configure dual processor system.
The maximum number of logical processors supported by OS
See the table below for the maximum number of logical processors that you can actually use on your
system.
Number of Logical Processors Supported by Operating Systems
Microsoft Windows Server 2008 R2 Standard (x64)
Microsoft Windows Server 2008 R2 Enterprise (x64)
Microsoft Windows Server 2012 Standard
Microsoft Windows Server 2012 Datacenter
Microsoft Windows Server 2012 R2 Standard
Microsoft Windows Server 2012 R2 Datacenter
Red Hat Enterprise Linux 6 (x86_64)
Red Hat Enterprise Linux 7
VMware ESXi 5.5
VMware ESXi 6.0
1
Maximum Available
Number of logical
Processors
256
1
88
640
1
88
240
88
320
480
88
88
The maximum numbers of logical processors when using Hyper-V are below
- Windows Server 2008 R2 : 64
- Windows Server 2012, Windows Server 2012 R2 : 320
NEC Corporation
Revision 1.1 – May, 2016
16
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
3 Memory
3.1
Memory Configuration
Refer to the section in accordance with your operating system and memory configuration:



Independent Channel: Refer to 3.1.1
Memory Sparing Configuration: Refer to 3.1.2
Memory Mirroring / Memory Lockstep Configuration: Refer to 3.1.3
Memory Configuration Feature Comparison
See the table below for feature comparisons of memory configurations supported.
Independent
Channel
Memory
Sparing
Memory
Lockstep
Memory
Mirroring
Performance
Data Protection
Best
No
Better
Multiple single bit
error protection
Better
No
Redundancy
Data Correction
Available Memory
No
ECC, x4 SDDC
Full physical
memory
4
Partly
ECC, x4 SDDC
5/6 physical memory
No
ECC, x8 SDDC
Full physical
memory
4
Good
Multiple single bit
and multi bit error
protection
Fully
ECC, x4 SDDC
Half physical
memory
4
-
All DIMMs in the
system must be
identical.
Paired DIMMs must
be identical.
Paired DIMMs must
be identical.
Available Memory
Channels
Notes
3.1.1
4
Independent Channel Configuration
Available slots: 12 per processor
Category
Product Name / Description
Part Number
Registered DIMM
(RDIMM)
8GB DDR4-2400 REG Memory Kit (2x4GB)
2 x 4GB Registered ECC DIMM, DDR4-2400(PC4-2400)
16GB DDR4-2400 REG Memory Kit (2x8GB)
2 x 8GB Registered ECC DIMM, DDR4-2400(PC4-2400)
32GB DDR4-2400 REG Memory Kit (2x16GB)
2 x 16GB Registered ECC DIMM, DDR4-2400(PC4-2400)
64GB DDR4-2400 REG Memory Kit (2x32GB)
2 x 32GB Registered ECC DIMM, DDR4-2400(PC4-2400)
128GB DDR4-2400 TSV REG Memory Kit (2x64GB)
2 x 64GB Registered ECC DIMM, DDR4-2400(PC4-2400)
N8102-663F
N8102-664F
N8102-665F
N8102-666F
N8102-667F
NOTE:

Minimum one memory kit per processor must be installed.

It is recommended to install memory kits in multiples of two (four identical DIMMs) for quad-channel
symmetric memory configurations to increase memory transfer speed.

When two processors are installed, balance the DIMMs across the two processors.

Mix configurations of 128GB memory kit and 8GB/16GB/32GB/64GB memory kit are not supported.
NEC Corporation
Revision 1.1 – May, 2016
17
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
3.1.2
Memory Sparing Configuration
Available slots: 12 per processor
Product Name / Description
Part Number
24GB DDR4-2400 REG Memory Kit (3x8GB)
3 x 8GB Registered ECC DIMM, DDR4-2400(PC4-2400)
48GB DDR4-2400 REG Memory Kit (3x16GB)
3 x 16GB Registered ECC DIMM, DDR4-2400(PC4-2400)
N8102-672
N8102-673
NOTE:





Minimum one memory kit per processor must be installed.
The configured memories must be identical.
When two processors are installed, balance the DIMMs across the two processors.
The logical memory capacity at the time of memory sparing becomes five-sixthes of physical capacity
with configurations less than DIMM
The maximum memory speed is 1866 MHz.
3.1.3
Memory Mirroring / Memory Lockstep Configuration
Available slots: 12 per processor
Product Name / Description
Part Number
16GB DDR4-2400 REG Memory Kit (2x8GB)
2 x 8GB Registered ECC DIMM, DDR4-2400(PC4-2400)
32GB DDR4-2400 REG Memory Kit (2x16GB)
2 x 16GB Registered ECC DIMM, DDR4-2400(PC4-2400)
N8102-669
N8102-670
NOTE:

Minimum one memory kit per processor must be installed.
NEC Corporation
Revision 1.1 – May, 2016
18
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Maximum Memory Speed
See the table below for the actual maximum memory transfer speed in Independent Channel / Memory
Sparing Configuration.
DDR4 memory speed depends on the type of DIMMs, the native memory bus speed of the memory
controller and memory configuration. All memory buses operate at the clock frequency of the DIMM with
the lowest frequency.
The maximum memory speed is 1866 MHz with Memory Sparing Configuration.
Processor Type
E5-2603 v4
E5-2620 v4
E5-2623 v4
E5-2630 v4
E5-2640 v4
E5-2637 v4
E5-2643 v4
E5-2650 v4
E5-2667 v4
E5-2680 v4
E5-2690 v4
E5-2697 v4
E5-2697A v4
E5-2698 v4
E5-2699 v4
Populated DIMMs
# of DIMMs per
processor
DIMM Speed
RDIMM: 4, 8, 16, 32, 64GB
-
1866 MHz
Memory Sparing
RDIMM: 4, 8, 16, 32, 64GB
Up to 8 DIMMs 10 or more DIMMs
-
1866 MHz
2133 MHz
1866 MHz
1866 MHz
Up to 8 DIMMs 10 or more DIMMs
-
2400 MHz
1866 MHz
1866 MHz
Memory Sparing
RDIMM: 4, 8, 16, 32, 64GB
Memory Sparing
Maximum Available Memory
See the table below for the maximum memory size that you can actually use on your system.
Maximum Memory Size Supported by Operating Systems
1
Microsoft Windows Server 2008 R2 Standard
1
Microsoft Windows Server 2008 R2 Enterprise
1
Microsoft Windows Server 2012 Standard
1
Microsoft Windows Server 2012 Datacenter
1
Microsoft Windows Server 2012 R2 Standard
1
Microsoft Windows Server 2012 R2 Datacenter
Red Hat Enterprise Linux 6 (x86_64)
Red Hat Enterprise Linux 7
2
VMware ESXi 5.5
3
VMware ESXi 6.0
1
2
3
Maximum Available Memory
32 GB
2 TB
4 TB
32 GB
1.5 TB
1.5 TB
6TB
1.5 TB
4 TB
6 TB
1.5 TB
1.5 TB
The maximum available memory size of Hyper-V systems are below:
- Windows Server 2008 R2 Standard : 32 GB
- Windows Server 2008 R2 Enterprise : 1TB
- Windows Server 2012, Windows Server 2012 R2:4 TB
Up to 1TB of main memory is available to each virtual machine.
Up to 4TB of main memory is available to each virtual machine.
NEC Corporation
Revision 1.1 – May, 2016
19
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
4 Internal Hard Disk Drives
4.1
RAID Configuration
Refer to the section in accordance with your OS and RAID configuration. For example, when you would like
to configure RAID 0/1/10 1GB cache with Windows Server 2012 R2, refer to the section 4.2.2 for the
required components and then refer to the section 4.3.2 for the hard drives.
Operating System
Supported RAID configuration
RAID and Cache
Section
Supported
HDD/SSD
Windows Server 2008 R2
VMware ESXi 5.5u3
VMware ESXi 6.0u1
KVM in Red Hat Enterprise Linux 6
(x86_64)
Non-RAID (Embedded SATA)
RAID 0/1/10
1GB Cache
4.2.1
4.3.1
4.2.2
4.3.2
RAID 5/6/50/60
RAID 5/6/50/60
1GB Cache
2GB Cache
4.2.3
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux 6 (x86_64)
without KVM feature
Red Hat Enterprise Linux 7
Non-RAID (Embedde SATA)
RAID 0/1/10
1GB Cache
4.2.1
4.3.1
4.2.2
4.3.3
RAID 5/6/50/60
RAID 5/6/50/60
4.2.3
1GB Cache
2GB Cache
4.2.4
4.2.4
NOTE:

Up to four hard drives can be installed in the Embedded SATA configuration.

All drives within a RAID array should be of the same type, capacity and rotation speed.

Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs,
SATA SSDs (ME) and SATA SSDs (VE) can be mixed in each drive cage.

It is recommended to set RAID array configuration drives less than eight per disk group in order to
minimize the risk of becoming multiple hard drives failure.

To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in
order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
NEC Corporation
Revision 1.1 – May, 2016
20
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
4.2
Required Components for RAID Configuration
4.2.1
Up to four Drives with Embedded SATA Controller
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4 x 6Gb/s SATA
Internal SATA Cable
1 x mini-SAS HD to 1 x mini-SAS HD
2.5-inch Drive Cage
8 x 2.5-inch Hot-plug hard drive bays
(Standard)
Cable
Drive Cage
(Standard)
(Standard)
NOTE:

Up to 4 SATA drives are supported.

For supported HDD/SSD, refer to 4.3.1

Hot plug insertion/removal are not supported in the configuration.
4.2.2
RAID 0/1 Controller with 1 GB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1)
LSI MegaRAID SAS 9362-8i
RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA
6Gb/s
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 2 sets
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
Including six sets of 1 x Mini SAS HD to 1 x Mini SAS HD
cable, SAS expander card
N8103-176
Flash Backup
Recommended
Cable
Drive Cage
Optional Drive Cage
(Required when
more than 8 drives)
N8103-181
(Standard)
(Standard)
N8154-69
NOTE:

For Supported HDD/SSD, refer to 4.3.2 for Windows Server 2008R2, Red Hat Enterprise Linux
6(x86_64) with KVM feature, or VMware. Refet to 4.3.3 for Windows Server 2012/2012R2, Red Hat
Enterprise Linux 6(x86_64) without KVM feature, or Red Hat Enterprise Linux 7.

All drives within a RAID array should be of the same type, capacity and rotation speed.

Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs,
SATA SSDs (ME) and SATA SSDs (VE) can be mixed in each drive cage.
NEC Corporation
Revision 1.1 – May, 2016
21
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
4.2.3
RAID 5/6 Controller with 1 GB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s,
SATA 6Gb/s
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 2 sets
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
Including six sets of 1 x Mini SAS HD to 1 x Mini SAS HD
cable, SAS expander card
N8103-177
Flash Backup
Recommended
Cable
Drive Cage
Optional Drive Cage
(Required when
more than 8 drives)
N8103-181
(Standard)
(Standard)
N8154-69
NOTE:

For Supported HDD/SSD, refer to 4.3.2 for Windows Server 2008R2, Red Hat Enterprise Linux
6(x86_64) with KVM feature, or VMware. Refet to 4.3.3 for Windows Server 2012/2012R2, Red Hat
Enterprise Linux 6(x86_64) without KVM feature, or Red Hat Enterprise Linux 7.

All drives within a RAID array should be of the same type, capacity and rotation speed.

Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs,
SATA SSDs (ME) and SATA SSDs (VE) can be mixed in each drive cage.
4.2.4
RAID 5/6 Controller with 2 GB Cache
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (2GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s,
SATA 6Gb/s
Flash Backup Unit
for LSI MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 2 sets
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
Including six sets of 1 x Mini SAS HD to 1 x Mini SAS HD
cable, SAS expander card
N8103-178
Flash Backup
Recommended
Cable
Drive Cage
Optional Drive Cage
(Required when
more than 8 drives)
N8103-181
(Standard)
(Standard)
N8154-69
NOTE:

For Supported HDD/SSD, refer to 4.3.2 for Windows Server 2008R2, Red Hat Enterprise Linux
6(x86_64) with KVM feature, or VMware. Refet to 4.3.3 for Windows Server 2012/2012R2, Red Hat
Enterprise Linux 6(x86_64) without KVM feature, or Red Hat Enterprise Linux 7.

All drives within a RAID array should be of the same type, capacity and rotation speed.

Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs,
SATA SSDs (ME) and SATA SSDs (VE) can be mixed in each drive cage.
NEC Corporation
Revision 1.1 – May, 2016
22
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
4.3
Supported HDD/SDD
4.3.1
For Embedded SATA Controller
Category
Drive
4 slots
available
4.3.2
SATA
HDD
(512n)
Product Name / Description
Part Number
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm,
512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm,
512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm,
512n sector
N8150-488
N8150-489
N8150-527
For RAID Controller Configuration (1)
For Windows Server 2008R2, KVM in Red Hat Enterprise Linux 6(x86_64), or VMware
Category
Drive
Standard :
8 slots
available
Max :
16 slots
available
SAS
HDD
(512n)
SATA
HDD
(512n)
SAS
SSD
(ME)
NEC Corporation
Product Name / Description
Part Number
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm,
512n sector
450GB 15K Hot Plug 2.5-inch SAS HDD
1x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm,
512n sector
600GB 15K Hot Plug 2.5-inch SAS HDD
1x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm,
512n sector
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm,
512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm,
512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm,
512n sector
200GB Hot Plug 2.5-inch SAS SSD
1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
400GB Hot Plug 2.5-inch SAS SSD
1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
N8150-479
Revision 1.1 – May, 2016
N8150-480
N8150-481
N8150-482
N8150-483
N8150-485
N8150-486
N8150-518
N8150-488
N8150-489
N8150-527
N8150-721
N8150-722
23
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
SATA
SSD
(ME)
SATA
SSD
(VE)
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-725
N8150-726
N8150-727
N8150-732
N8150-733
N8150-734
N8150-735
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.

Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs,
SATA SSDs (ME) and SATA SSDs (VE) can be mixed in each drive cage.

For monitoring SATA SSD life on VMware, NEC ESMPRO Manager Ver.6.05 or later is required.
Please download the latest version on the NEC web site.

The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details.
4.3.3
For RAID Controller Configuration (2)
For Windows Server 2012/2012R2, Red Hat Enterprise Linux 6(x86_64) without KVM, or Red Hat
Enterprise Linux 7
Category
Drive
Standard :
8 slots
available
Max :
16 slots
available
SAS
HDD
(512n)
SAS
HDD
(4Kn)
SATA
HDD
(512n)
NEC Corporation
Product Name / Description
Part Number
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm,
512n sector
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm,
512n sector
450GB 15K Hot Plug 2.5-inch SAS HDD
1x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm,
512n sector
600GB 15K Hot Plug 2.5-inch SAS HDD
1x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm,
512n sector
1.8TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.8TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 4Kn sector
N8150-479
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm,
512n sector
N8150-488
Revision 1.1 – May, 2016
N8150-480
N8150-481
N8150-482
N8150-483
N8150-485
N8150-486
N8150-518
N8150-490
24
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
SAS
SSD
(ME)
SATA
SSD
(ME)
SATA
SSD
(VE)
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm,
512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm,
512n sector
200GB Hot Plug 2.5-inch SAS SSD
1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
400GB Hot Plug 2.5-inch SAS SSD
1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-489
N8150-527
N8150-721
N8150-722
N8150-725
N8150-726
N8150-727
N8150-732
N8150-733
N8150-734
N8150-735
NOTE:

All drives within a RAID array should be of the same type, capacity and rotation speed.

Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs, SAS SSDs,
SATA SSDs (ME) and SATA SSDs (VE) can be mixed in each drive cage.

The 4Kn sector drives are make-to-order products. Please consult your sales representative in regard
to production lead time.

When you select 4Kn sector HDD, confirm whether your applications support hard drives with 4Kn
sector size. For more information, visit the NEC website at:
http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN.pdf


512n sector HDD and 4Kn sector HDD cannot be mixed.
The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to Endurance of SSD for details.
5 2.5-inch PCIe SSD
5.1
2.5-inch PCIeSSD Installation Kit
Product Name / Description
Part Number
2.5-inch PCIeSSD Installation Kit
2.5-inch Drive Cage for 4 x SDDs, PCIe SSD switch card, and PCIe cable
N8118-301
NOTE:

One PCIe slot is required to install the PCIe SSD switch card.

2.5-inch Additional HDD Cage Bay is used to install 2.5-inch PCIeSSDs. Therefore, the 2.5-inch Drive
Cage N8154-69 cannot be installed at the same time.
Four PCIe SSDs
can be installed



The PCIe SSD slots do not support hot-plug.
RAID configuration of PCIe SSDs is not supported.
Operating system cannot be installed on any PCIe SSD.
NEC Corporation
Revision 1.1 – May, 2016
25
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
5.2
PCIe SSD
Category
Product Name / Description
Part Number
PCIe SSD
4 slots available
800GB Non-Hot Plug 2.5-inch PCIe SSD
- 1x 800 GB PCIe SSD, 2.5-inch
N8118-500
NOTE:

2.5-inch PCIeSSD Installation Kit is required to install this product.

Warranty period is 3 years (36 months) or until the total bytes of written value (TBW) exceeds the limit
value, whichever occurs first. It is recommended to check the TBW periodically.

Operating system cannot be installed on any PCIe SSD.
6 Optical Drive
Category
Product Name / Description
Part Number
Internal
1 slot available
Internal Slim DVD-ROM drive
Slim DVD-ROM drive
DVD read speed: 8x (DVD-ROM / DVD-R / DVD-RW)
CD read speed: 24x (CD-ROM / CD-R/RW)
Internal DVD Super Multi Drive
Slim DVD Super Multi drive, not including writing software
DVD Read speed: 8x (DVD-R / DVD-RW / DVD-R DL / DVD+R /
DVD+RW / DVD+R DL / DVD-ROM)
DVD-RAM read speed: 5x
CD read speed: 24x (CD-ROM / CD-R/RW)
External DVD Super MULTI Drive
USB, Slim DVD Super Multi drive, not including writing software
DVD Read speed: 8x (DVD-R / DVD-RW / DVD-R DL / DVD+R /
DVD+RW / DVD+R DL / DVD-ROM)
DVD-RAM read speed: 5x
CD read speed: 24x (CD-ROM / CD-R/RW)
N8151-134
External
N8151-135F
N8160-97F
NOTE:

Up to 1 optical drive can be connected.
7 Internal RDX Drive
7.1
RDX Configuration
Category
Product Name / Description
Part Number
Controller
Internal USB Controller
1 x USB port
Internal USB cable
1 x Internal USB to 1 x USB device, USB 3.0
(Standard)
Internal RDX (USB)
N8151-125
Cable
Drive
1 bay available
NEC Corporation
Revision 1.1 – May, 2016
K410-275(00)
26
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
8 PCI Riser Card / PCI Card
Please refer to Supported PCI Cards and Installable Slots with regard to the position of PCI slot which
can mount PCI card supported.
8.1
PCI Riser Card
Product Name / Description
Part Number
PCIe Riser Card Kit
8 x PCIe 3.0 x8
PCIe x16 Riser Card Kit
1 x PCIe 3.0 x16, 6x PCIe 3.0 x8, auxiliary power connector (8pin)
PCIe x16 Riser Card Kit
1 x PCIe 3.0 x16, 6x PCIe 3.0 x8, auxiliary power connector (8+6pin)
PCIe x4/x16 FH Riser Card Kit set
1x PCIe 3.0 x16, 5x PCIe 3.0 x8, 2x PCIe 3.0 x4
For PCI Slot C
PCIe x4/x16 LP Riser Card Kit set
2x PCIe 3.0 x16, 2x PCIe 3.0 x8, 4x PCIe 3.0 x4
For PCI Slot D
NOTE:
- N8116-45 is required to use this option.
PCIe x4/x16 FH/LP Riser Card Kit set
- 2x PCIe 3.0 x16, 2x PCIe 3.0 x8, 4x PCIe 3.0 x4
For PCI Slot C, Slot D
(Standard)
N8116-34
N8116-34A
N8116-45
N8116-46
N8116-49
NOTE:




PCI Slot #2C, #3C, #2D, #3D are support in dual processor configurations only.
PCI Slot #3C is not available when N8116-34/-34A Riser Card(PCIex16) is installed.
PCI Slot #3C, #3D of N8116-49 are support in dual processor configurations only.
N8116-45 and N8116-46 will be available in June, 2016.
8.2
Full Length PCI Card installation Kit
For a full-length PCI card (D=312mm/12.28 in) installation in PCI Slot #2C
Product Name / Description
Part Number
Full Length PCI Card installation Kit
For a full-length installation, contains special heat sinks
N8116-37
NOTE:

Since this product is make-to-order manufacturing, the support is provided individually. Contact your
sales representative for details.
8.3
Graphics Card Installation Kit
For GPU card installation
Product Name / Description
Part Number
Graphics Card Installation Kit
Power cables for video card (6+2pin) , a retainer to secure the graphics board
NOTE:
- N8116-34, N8116-37, and two processors are required to use this option.
N8116-38
Graphics Card Installation Kit
Power cables for video card (6+2pin, 6pin) , two retainers to secure the graphics board
NOTE:
- N8116-34A, N8116-37, and two processors are required to use this option.
N8116-38A
NEC Corporation
Revision 1.1 – May, 2016
27
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Graphics Card Installation Kit
Power cables for video card (8pin), a retainer to secure the graphics board, heat sink and
air duct included
NOTE:
- This option is applicable to N8100-2423F (1000W power supply model) only.
- N8116-34/34A, two processors, and N8181-125 are required to use this option.
N8116-47
NOTE:

Since this product is make-to-order manufacturing, the support is provided individually. Contact your
sales representative for details.

This product does not support/guarantee installation of general video cards on R120g-2M. Please
consult with your sales representative for the tested GPU cards.
8.4
Network Interface Controller
Category
LOM card
Required
1GbE
10GbE
Adapter
1GbE
10GbE
NEC Corporation
Product Name / Description
Part Number
Quad Port 1000BASE-T LOM Card
Broadcom® BCM5719
PCIe 2.0 x4
Dual Port 10GBASE-T LOM Card
Intel® Ethernet Controller X540
PCIe 2.0 x8
Dual Port 10GBASE-T LOM Card
Intel Ethernet Controller X550
PCIe 3.0(x8)
NOTE:
- Available in June, 2016
Dual Port 10G-SFP + Dual Port 1000BASE-T LOM Card
Qlogic NetXtreme II BCM57800S
PCIe 2.0 x8
NOTE:
- N8104-129 SFP+ Module is required to connect with an optical
cable.
- Up to two SFP+ Modules can be installed.
N8104-154F
1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller
PCIe 2.0 x1
Dual Port 1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller
PCIe 2.0 x1
Dual Port 1000BASE-T Adapter
Intel® 82580 Gigabit Ethernet Controller
PCIe 2.0 x4
NOTE:
- PXE boot is not supported on UEFI environment.
Quad Port 1000BASE-T Adapter
Broadcom ® BCM5719 Gigabit Ethernet Controller
PCIe 2.0 x4
NOTE:
- Network cables with RJ-45 plug covers cannot be used.
N8104-150
Dual Port 10GBASE SFP+ Adapter (SFP+/2ch)
Intel® 82599ES 10 Gigabit Ethernet Controller
PCIe 2.0 x8, Low Profile / Full Height
NOTE:
- N8104-129 SFP+ Module is required to connect with an optical
cable.
- Up to 2 SFP+ Modules can be installed.
N8104-148
Revision 1.1 – May, 2016
N8104-155F
N8104-160F
N8104-156F
N8104-151
N8104-145
N8104-152
28
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
SPF+
Module
10GBASE SFP+ Adapter (SFP+/2ch)
Qlogic NetXtreme II BCM57810S
PCIe 2.0 x8, Low Profile / Full Height
NOTE:
- N8104-129 SFP+ Module is required to connect with an optical
cable.
Dual Port 10GBASE-T Adapter
Intel® Ethernet Controller X540
PCIe 2.0(x8) , Low Profile / Full Height
Dual Port 10GBASE-T Adapter
Intel® Ethernet Controller X550
PCIe 3.0 x4, Low Profile / Full Height
SFP+ Module (10G-SR)
1 x SFP+ Module for N8104-148, N8104-149, and N8104-156F
N8104-149
N8104-153
N8104-157
N8104-129
NOTE:

Supports up to three 10GbE network adapters in a single-processor configuration, and up to five in a
dual-processor configuration.

Network performance may be reduced depending on the applications and memory performance when
three or more 10Gb Network Adapters are installed.

For VMware ESXi 5.5 and ESXi 6.0, there are some limitations concerning the number of installable
PCI cards. Refer to Supported PCI Cards and Installable Slots for details.
NIC Teaming feature – NIC Teaming and bonding features
See the table below for supported network interfaces and OS combinations.
Windows Server 2008 R2 supports BASP (Broadcom Advanced Server Program) or Intel PROSet teaming
while Windows Server 2012 (and later) and Linux support teaming with bonding function supported by OS.
Network Interface
Team
Operating Systems
1GbE NIC
N8104-150/-151/-152/-154F/-156F
Up to four ports per one team
1GbE NIC
N8104-145
10GbE NIC
N8104-149/-156F
Up to four ports per one team
Windows Server 2008 R2
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux
Windows Server 2008 R2
10GbE NIC
N8104-148
10GbE NIC
N8104-153/-155F/-157/-160F
Up to four ports per one team
Up to four ports per one team
Up to four ports per one team
Windows Server 2008 R2
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux
Red Hat Enterprise Linux
7.2 or later
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux
NOTE:

NIC Teaming feature is not supported on iSCSI interfaces.

The network interfaces for each teaming must be the same.

When 10GbE and 1GbE NIC teams are mixed, the maximum number of teams must be as follows:
- Windows Server 2008 R2 : up to four per one system
- Windows Server 2012, Windows Server 2012 R2 : up to five per one system
- Red Hat Enterprise Linux : up to five per one system
NEC Corporation
Revision 1.1 – May, 2016
29
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Using iSCSI
See the table below for supported network interfaces and operating system combinations.
Category
Network Interface
Operating Systems
1GbE
N8104-150/-151/-152/-154F/-156F
10GbE
N8104-145
N8104-149/-156F
Windows Server 2008 R2, Windows Server 2012,
Windows Server 2012 R2, Red Hat Enterprise Linux, VMware
Windows Server 2008 R2, VMware
Windows Server 2008 R2, Windows Server 2012,
Windows Server 2012 R2, Red Hat Enterprise Linux, VMware
Red Hat Enterprise Linux 7.2 or later
Windows Server 2012, Windows Server 2012 R2
Red Hat Enterprise Linux, VMware
Windows Server 2012, Windows Server 2012 R2
Red Hat Enterprise Linux
N8104-148
N8104-153/-155F
N8104-157
NOTE:

NIC Teaming feature is not supported on iSCSI interfaces.
8.5
InfiniBand
Category
Product Name / Description
Part Number
Controller
Single Port InfiniBand Adapter
Mellanox ConnectX-3 VPI, MCX353A-FCBT,
FDR, PCIe 3.0(x8)
Dual Port InfiniBand Adapter
Mellanox ConnectX-3 VPI, MCX354A-FCBT,
FDR, PCIe 3.0(x8)
InfiniBand Cable 2m/FRD
Copper
InfiniBand Cable 3m/FDR
Copper
InfiniBand Switch 36 ports/FDR
Mellanox MSX6036F-1SFR
36 ports, FDR, One power supply module included, no power
cord
Redundant Power Supply Unit
Power supply module for 36 ports InfiniBand switch, no power
cord
N8104-146
Cable
Switch
Unit
Power
Supply
N8104-147
K410-304(02)
K410-304(03)
NE3707-061
NE3707-063
NOTE:

Up to two InfiniBand adapters can be installed into the system and two adapters should be of the
same type.

The InfiniBand adapters and other options are make-to-order products. Please consult your sales
representative in regards to production lead time.
NEC Corporation
Revision 1.1 – May, 2016
30
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
8.6
External Storage Controller
8.6.1
RAID Controller
Category
Product Name / Description
Part Number
Controller
RAID Controller (2GB, RAID0/1/5/6)
LSI MegaRAID SAS 9380-8e
RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s,
SATA 6Gb/s,
Flash cache protection modules included
N8103-179
NOTE:

To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in
order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.

It is recommended to set RAID array configuration drives less than eight in order to minimize the risk
of becoming multiple hard drives failure.

For VMware ESXi 5.5 and ESXi 6.0, there are some limitations concerning the number of installable
PCI cards. Refer to Supported PCI Cards and Installable Slots for details.
8.6.2
Fibre Channel / SAS Controller
Category
Product Name / Description
Part Number
Fibre Channel
Fibre Channel Controller (1ch)
Emulex LightPulse LPe1250-F8 Host Bus Adapter
8Gb/s, Optical, PCIe 2.0 x8
Fibre Channel Controller (2ch)
Emulex LightPulse LPe12002-M8 Host Bus Adapter
8Gb/s, Optical, PCIe 2.0 x8
Fibre Channel Controller (1ch)
Emulex LightPulse LPe16000B-M6 Host Bus Adapter
16Gb/s, Optical, PCIe 3.0 x8
Fibre Channel Controller (2ch)
Emulex LightPulse LPe16002B-M6 Host Bus Adapter
16Gb/s, Optical, PCIe 3.0 x8
SAS Controller
LSI SAS9212-4i4e Host Bus Adapter
6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8
SAS Controller
LSI SAS9300-8e Host Bus Adapter
12Gb/s SAS, ext. 8(SFF-8644 x2), PCIe 3.0 x8
N8190-159
SAS
N8190-160
N8190-157A
N8190-158A
N8103-142
N8103-184
NOTE:

Up to four 16Gb/s Fiber Channel Controllers can be installed. However, up to two ports in a single
processor configuration with Xeon E5-2603 v4, and up to six ports in a dual processor configuration
with Xeon E5-2603 v4

Up to three SAS Controllers can be installed.

For VMware ESXi 5.5 and ESXi 6.0, there are some limitations concerning the number of installable
PCI cards. Refer to Supported PCI Cards and Installable Slots for details.
8.7
Serial Port Adapter
Product Name / Description
Part Number
Serial Port Adapter
Serial port fixed to PCI bracket
N8117-01A
NOTE:

Up to one Serial Port Adapter can be installed.
NEC Corporation
Revision 1.1 – May, 2016
31
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
9 Other Add-in Components
9.1
Power Supply Module
Product Name / Description
Part Number
460W Hot Plug Power Supply
1 x 460 Watt 80 PLUS® Platinum
800W Hot Plug Power Supply
1 x 800 Watt 80 PLUS® Platinum
1000W Hot Plug Power Supply
1 x 1000 Watt 80 PLUS® Platinum
800W Hot Plug Power Supply
1 x 800 Watt 80 PLUS® Titanium
- NOTE: 200 VAC input only supported
N8181-121F
N8181-122F
N8181-123F
N8181-118F
NOTE:

The power units must be the same to configure redundancy.
9.2
Redundant Fan Kit
Product Name / Description
Part Number
Redundant Fan Kit
4(1CPU), 5(2CPU) hot plug redundant cooling fans for R120g-2M
Redundant Fan Kit
5(1CPU), 10(2CPU) hot plug redundant cooling fans for R120g-2M
(Standard)
N8181-125
NOTE:

In a 35 degrees C environment, the fans are N+1 redundant as standard, but CPU and/or memory
throttling may occur when a fan is broken.

For 40 degrees C environment or full redundancy, arrange N8181-125 redundant fan kit.
9.3
Trusted Platform Module Kit
Product Name / Description
Part Number
Trusted Platform Module Kit
TPM 2.0 module
N8115-26
NOTE:

The kit is not available in China.

The kit is not removable after attachment.

"TPM Support" in BIOS setup menu must be activated prior to use of this kit.

To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker
function. The recovery password is required to restore data for hardware replacement during a
system error.
9.4
Internal Flash Memory
Product Name / Description
Part Number
VMware ESXi support kit
Internal USB flash memory to install VMware ESXi system
N8106-009
NOTE:

The kit does not include VMware ESXi installation media and license.
NEC Corporation
Revision 1.1 – May, 2016
32
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
9.5
High Temperature Support Option
Product Name / Description
Part Number
High temperature resistant Kit
Required for high temperature operation over 40°C (up to 45°C)
NOTE: This option is not applicable to N8100-2420F (460 Watt power supply model).
N8181-144F
NOTE:

To apply this option, there are some configuration limitations below.
Required System Configuration:
- Installed memory must be 6 DIMMs per processor or less.
- Up to two Flash backup units for RAID controller can be installed.
- Do not install N8102-667F 128GB DDR4-2400 REG Memory Kit (2x64GB)
- Do not install N8181-125 Redundant Fan Kit
- Do not install N8151-125 Internal RDX (USB)
9.6
Flash FDD
Choose the Flash FDD if you need to prepare an alternative device for a floppy drive.
Product Name / Description
Part Number
Flash FDD
USB flash emulating USB floppy disk, Native capacity 1.44 MB
N8160-96
NOTE:

Up to one drive can be connected.
NEC Corporation
Revision 1.1 – May, 2016
33
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
10 Add-on Components
10.1
17-inch LCD Console Drawer
Category
Drawer
Drawer
w/ KVM
Cable
Drawer
Drawer
w/o KVM
Keypad
Product Name / Description
Part Number
17-inch LCD Console Drawer (8port)
17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port
KVM switch, 1U height
Switch Unit Connection Cable Set (USB, 1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB, 3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB, 5m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
17inch LCD Console Unit 1U
17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height,
4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable
2m, 15-pin mini D-sub VGA cable 2 m
17inch LCD Console Drawer (1port)
17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad
with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8
m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m
Keyboard Unit (JP)
JP 108-keys Keyboard with 10-key for N8143-108F 17inch LCD
Console Drawer (1port)
Keyboard Unit (UK)
UK 104-keys Keyboard with 10-key, for N8143-108F 17inch
LCD Console Drawer (1port)
N8143-106F
K410-118(1A)
K410-118(03)
K410-118(05)
N8143-105F
N8143-108F
N8143-109
N8143-111
NOTE:

There are two VGA connectors on R120g-2M, one on the front side and one on the rear side.
However, the front side only works when both are connected at the same time.
10.2
KVM Switch
Category
Product Name / Description
Part Number
KVM Switch
Server Switch Unit (8 server)
1U USB 8 port KVM switch
N8191-14F
Switch Unit Connection Cable Set (USB,1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB,3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB,3m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable 1.8 m
1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2
K410-118(1A)
Cable
KVM
Cascading
K410-118(03)
K410-118(05)
K410-119(1A)
NOTE:

There are two VGA connectors on R120g-2M, one on the front side and one on the rear side.
However, the front side only works when both are connected at the same time.
NEC Corporation
Revision 1.1 – May, 2016
34
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
10.3
Cable Management Arm
Product Name / Description
Part Number
Cable Management Arm 2U Kit
For R120g-2M
N8143-95
10.4
Server Management License
The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the
standard management features. For more extensive remote KVM and remote media features, choose the
following kit.
Product Name / Description
Part Number
Remote KVM and Media License Kit
N8115-04
License for one server.
Remote KVM and remote media are enabled regardless of OS status.
Remote KVM:
Displays a graphics console on the web browser of the remote terminal
(PC/server).
Controls keyboard and mouse via the remote terminals' web browser
Remote media:
Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals
(PC/server) as if accessing the local drives.
NOTE: Remote KVM and remote media features are not available for virtual machines.
10.5
Medium and Cartridge
Category
Product Name
Drive supported
Part Number
RDX
RDX Cartridge (500GB)
RDX Cartridge (1TB)
RDX Cartridge (2TB)
RDX Cartridge (3TB)
N8151-125
N8151-125
N8151-125
N8151-125
N8153-02
N8153-03
N8153-09
N8153-10
NEC Corporation
Revision 1.1 – May, 2016
35
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
References
Boot Mode Setting
The server supports Legacy mode and UEFI mode (default) as an OS Boot Mode. See the table below for
the Boot Mode and X2APIC setting for each Operating System. As the default settings at the factory, UEFI
mode is set as OS Boot mode and X2APIC is enabled. Refer to the User’s Guide and change the settings
before installing an Operating System requiring Legacy Mode.
Operating System
Supported Boot Mode
Supported X2APIC Setting
Windows Server 2008 R2 (x64)
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux 6(x86_64)
Red Hat Enterprise Linux 7
VMware ESXi 5.5 Update3
VMware ESXi 6.0 Update1
Legacy
UEFI
UEFI
UEFI
UEFI
Legacy
Legacy
Disabled
Enabled
Enabled
Enabled
Enabled
Disabled
Disabled
NEC Corporation
Revision 1.1 – May, 2016
36
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Server Management
The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system
management features listed in the table below.
Standard
Hardware
monitoring
Boot monitoring
Alerting
Remote KVM
(via LAN)
Remote control
(via LAN)
Maintenance
Others
1
2
3
4
5
Temperature/voltage/power/RAID/
standard LAN/fan /degeneration
(memory/hard drive)
Hardware configuration information collection
Hardware event log collection
BIOS/POST stall, Booting, OS stall, shutdown
HW error, Boot error , and OS panic
(by SNMP, E-Mail)
POST/BIOS setup, ROM utility
Panic screen, Boot screen
CUI-based screen (OS console)
GUI-based screen (OS console)
Remote console recording function
Video recording
Remote reset/power on-off/ dump
Remote power capping
BIOS/BMC FW update
Remote BIOS setup(partial configuration only)
OS shutdown
Remote media (CD/DVD/FD/USB)
CLP (Command Line Protocol) (DMTF
compliant)
Remote control via Web browser (multi user
login at the same time)
Scheduling (without UPS)
BIOS setting by using XML file
EXPRESSSCOPE® Profile key
(Backup/restore BIOS/BMC setup information)
Set automatic IP address via DNS/DHCP
LDAP/Active Directory verification/user control
Clock synchronization of main unit and the RTC
Access log collection
IPMI
IPv6(Web console/CLP only)
With Remote KVM
and Media License
kit
5
5


1
 



1
 

 
2, 3, 4


2, 4
 




1
 

2










1
 




1
1
 


 










2.0

2.0

The feature is not supported on VMware ESXi systems.
The optional serial port is not available for the feature.
Monitoring boot screens is not supported on VMware systems.
In VMware systems, only the direct console user interface is supported.
To obtain the information of N8104-156F Dual Port 10G-SFP + Dual Port 1000BASE-T LOM Card, the BMC
firmware version must be 02.11 or later.
NEC Corporation
Revision 1.1 – May, 2016
37
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Endurance of SSD
The 2.5-inch SAS/SATA SSDs have limited lifetime, which can only be written a limited number of times
before it fails.
The warranty period of SSD is the stated period of warranty or until the total bytes of written value (PBW)
exceeds the limit value, whichever occurs first. It is recommended to check the total bytes of written value
periodically.
Refer to the table below for the write endurance (PBW and DWPD), warranty period and monitoring tool.
SSD Lifetime
Part
Number
Product Name
PBW
DWPD
Period
Monitoring Tool
N8150-721
200GB Hot Plug
2.5-inch SAS SSD
3.6PBW
10 Times
3 Years
N8150-722
400GB Hot Plug
2.5-inch SAS SSD
7.3PBW
10 Times
3 Years
Universal RAID Utility,
EXPRESSBUILDER
(System Test and
Diagnostics)
SAS SSD
SATA SSD (Middle Endurance)
N8150-725
200GB Hot Plug
2.5-inch SATA SSD
3.6PBW
10 Times
3 Years
N8150-726
400GB Hot Plug
2.5-inch SATA SSD
7.3PBW
10 Times
3 Years
N8150-727
800GB Hot Plug
2.5-inch SATA SSD
14.6PBW
10 Times
3 Years
SATA SSD (Value Endurance)
N8150-732
200GB Hot Plug
2.5-inch SATA SSD
1.1PBW
3 Times
3 Years
N8150-733
400GB Hot Plug
2.5-inch SATA SSD
3.0PBW
3 Times
3 Years
N8150-734
800GB Hot Plug
2.5-inch SATA SSD
5.3PBW
3 Times
3 Years
N8150-735
1.6TB Hot Plug
2.5-inch SATA SSD
10.7PBW
3 Times
3 Years





PBW(Peta-Bytes Write): Total amount of data that can be written into the SSD. 1PB=1,000TB.
DWPD(Drive Writes per Day): Rewrite capacity of the SSD per day.
Check the lifetime of SSD by monitoring tool regularly.
It is recommended to replace the SSD before it reaches its end of life. For repurchase, please contact your sales representative.
For detailed operating methods of monitoring tool, refer to the User’s Guide.
NEC Corporation
Revision 1.1 – May, 2016
38
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
OS Support Matrix for PCI Cards and Embedded Controllers
ESXi 5.5
ESXi 6.0
RHEL 6 x64
RHEL 7
WS 2008 R2
WS 2012
WS 2012 R2
Part number
Product Name
N8103-176
N8103-177
N8103-178
N8103-179
N8103-184
N8103-142
N8190-158A
N8190-157A
N8190-160
N8190-159
N8104-155F
N8104-160F
N8104-156F
Embedded SATA non-RAID Controller
RAID Controller (1GB, RAID 0/1)
RAID Controller (1GB, RAID 0/1/5/6)
RAID Controller (2GB, RAID 0/1/5/6)
RAID Controller (2GB, RAID0/1/5/6)
SAS Controller
SAS Controller
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
Dual Port 10GBASE-T LOM Card
Dual Port 10GBASE-T LOM Card
Dual Port 10G-SFP + Dual Port 1000BASE-T
LOM Card
Quad Port 1000BASE-T LOM Card
Dual Port 10GBASE-T Adapter
Dual Port 10GBASE-T Adapter
10GBASE SFP+ Adapter (SFP+/2ch)
Dual Port 10GBASE SFP+ Adapter (SFP+/2ch)
Quad Port 1000BASE-T Adapter
Dual Port 1000BASE-T Adapter
Dual Port 1000BASE-T Adapter
1000BASE-T Adapter
Dual Port InfiniBand Adapter
Single Port InfiniBand Adapter
2.5-inch PCIeSSD Installation Kit
N8104-154F
N8104-157
N8104-153
N8104-149
N8104-148
N8104-152
N8104-145
N8104-151
N8104-150
N8104-147
N8104-146
N8118-301
NEC Corporation
Revision 1.1 – May, 2016





- 





- 
- 


- - -
- 

- - - - -

- - - -


- - -
- - -
- - - -
39
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Supported PCI Cards and Installable Slots
Standard Riser Card
Slots
Prio
rity
Part Number
(1)
(2)
(3)
N8104-155F
N8104-160F
N8104-156F
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
N8104-154F
N8103-176
N8103-177
N8103-178
N8103-179
N8118-301
N8190-158A
N8190-157A
N8104-147
N8104-146
N8103-184
N8104-157
N8104-153
N8104-149
N8104-148
(19)
(20)
(21)
(22)
(23)
(24)
(25)
(26)
N8190-160
N8190-159
N8103-142
N8104-152
N8104-145
N8104-151
N8104-150
N8117-01A
Product Name
Dual Port 10GBASE-T LOM Card
Dual Port 10GBASE-T LOM Card
Dual Port 10G-SFP + Dual Port
1000BASE-T LOM Card
Quad Port 1000BASE-T LOM Card
RAID Controller (1GB, RAID 0/1)
RAID Controller (1GB, RAID 0/1/5/6)
RAID Controller (2GB, RAID 0/1/5/6)
RAID Controller (2GB, RAID0/1/5/6)
2.5-inch PCIeSSD Installation Kit
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
Dual Port InfiniBand Adapter
Single Port InfiniBand Adapter
SAS Controller
Dual Port 10GBASE-T Adapter
Dual Port 10GBASE-T Adapter
10GBASE SFP+ Adapter (SFP+/2ch)
Dual Port 10GBASE SFP+ Adapter
(SFP+/2ch)
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
SAS Controller
Quad Port 1000BASE-T Adapter
Dual Port 1000BASE-T Adapter
Dual Port 1000BASE-T Adapter
1000BASE-T Adapter
Serial Port Adapter
#1A #1B #1C #2C #3C #1D #2D #3D
-
(1)
(1)
(1)
-
-
-
-
-
-
(1)
(1)
(1)
-
(1)
-
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
-
-
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
-
(4)
(4)
(4)
(4)
(4)
(4)
(4)
-
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(3)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(4)
NOTE:

The slot #2C, #3C, #2D, and #3D are available in a dual-processor configuration.

Up to 312 mm / 12.28in length card can be installed into slot #2C when N8116-37 Full Length PCI
Card installation Kit is installed.

The number between parentheses shows the population priority (recommendation). For example,
install N8104-155F (1) in the slot #1B, N8103-176 (5) in the slot #1A, N8104-153 (16) in the slot #1C
and N8190-160 (19) in the slot #1D when you install those cards.

For VMware ESXi 5.5, there are some limitations as follows:
<With N8104-154F Quad Port 1000BASE-T LOM Card>
- N8104-149/-153/-157 and N8104-150/-151/-152 cannot be mixed.
- Up to one card among N8103-176/-177/-178/-179 can be installed.
- When configured with Xeon E5-2697v4/2697Av4/2698v4/2699v4,
a) Up to two cards among N8104-151/-152/-149/-153/-157 can be installed
b) Up to two cards among N8104-150/N8190-160/N8190-158A/N8103-184 can be installed
* Up to three cards when the above a) and b) are mixed
- When configured with Xeon E5-2603v4/E5-2620Av4/E5-2623v4/E5-2630v4/E5-2637v4/E5-2640v4/
E5-2643v4/E5-2650v4/2667v4/2680v4/2690v4,
c) Up to three cards among N8104-152/-149/-153/-157 can be installed
d) Up to six cards among N8104-150/N8104-151/N8190-160/N8190-158A/N8103-184 can be
installed
NEC Corporation
Revision 1.1 – May, 2016
40
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M


* When the above c) and d) are mixed, up to four cards can be installed.
<With N8104-155F Dual Port 10GBASE-T LOM Card>
- N8104-150/-151 and N8104-152 cannot be mixed.
- Up to two cards of N8104-150/-151 can be installed.
- Up to one card of N8104-152 can be installed.
- Up to one card among N8103-176/-177/-178/-179 can be installed.
- When configured with Xeon E5-2697v4/E5-2697Av4/E5-2698v4/E5-2699v4,
a) Up to two cards among N8104-151/-152/-149/-153/-157 can be installed
b) Up to two cards among N8104-150/N8190-160/N8190-158A/N8103-184 can be installed
* Up to three cards when the above a) and b) are mixed
- When configured with Xeon E5-2603v4/E5-2620Av4/E5-2623v4/E5-2630v4/E5-2637v4/E5-2640v4/
E5-2643v4/E5-2650v4/E5-2667v4/E5-2680v4/E5-2690v4,
c) Up to three cards among N8104-152/-149/-153/-157 can be installed
d) Up to six cards among N8104-150/N8104-151/N8190-160/N8190-158A/N8103-184 can be
installed
* When the above c) and d) are mixed, up to four cards can be installed.
<With N8104-156F Dual Port 10G-SFP + Dual Port 1000BASE-T LOM Card >
- Up to two cards of N8104-150/-151 can be installed.
- N8104-152 cannot be installed.
- Up to one card among N8103-176/-177/-178/-179 can be installed.
- When configured with Xeon E5-2697v4/E5-2697Av4/E5-2698v4/E5-2699v4,
a) Up to one card among N8104-151/-149/-153/-157 can be installed
b) Up to two cards among N8104-150/N8104-151/N8190-160/N8190-158A/N8103-184 can be
installed
* Up to two cards when the above a) and b) are mixed
- When configured with Xeon E5-2603v4/E5-2620Av4/E5-2623v4/E5-2630v4/E5-2637v4/E5-2640v4/
E5-2643v4/E5-2650v4/E5-2667v4/E5-2680v4/E5-2690v4,
c) Up to two cards among N8104-149/-153/-157 can be installed
d) Up to five cards among N8104-150/N8104-151/N8190-160/N8190-158A/N8103-184 can be
installed
* When the above c) and d) are mixed, up to four cards can be installed.
For VMware ESXi 6.0, there are some limitations as follows:
- With N8104-154F Quad Port 1000BASE-T LOM Card:
N8104-149/-153/-157 and N8104-150/-151/-152 cannot be mixed
- With N8104-155F Dual Port 10GBASE-T LOM Card:
N8104-150/-151 and N8104-152 cannot be mixed.
Up to two cards of N8104-150/-151 can be installed.
Up to one N8104-152 can be installed
- With N8104-156F Dual Port 10GBASE-T LOM Card:
Up to one of N8104-150/-151 can be installed.
N8104-152 cannot be installed.
For the configuration limitation for VMware ESXi, refer to the following documents.
VMware ESXi5.5
https://www.vmware.com/pdf/vsphere5/r55/vsphere-55-configuration-maximums.pdf
VMware ESXi6.0
https://www.vmware.com/pdf/vsphere6/r60/vsphere-60-configuration-maximums.pdf
NEC Corporation
Revision 1.1 – May, 2016
41
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
N8116-34/34A PCIe x16 Riser Card Kit
Slots
Prio
rity
Part Number
(1)
(2)
(3)
N8104-155F
N8104-160F
N8104-156F
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
N8104-154F
N8103-176
N8103-177
N8103-178
N8103-179
N8118-301
N8190-158A
N8190-157A
N8104-147
N8104-146
N8103-184
N8104-157
N8104-153
N8104-149
N8104-148
(19)
(20)
(21)
(22)
(23)
(24)
(25)
(26)
N8190-160
N8190-159
N8103-142
N8104-152
N8104-145
N8104-151
N8104-150
N8117-01A
Product Name
Dual Port 10GBASE-T LOM Card
Dual Port 10GBASE-T LOM Card
Dual Port 10G-SFP + Dual Port
1000BASE-T LOM Card
Quad Port 1000BASE-T LOM Card
RAID Controller (1GB, RAID 0/1)
RAID Controller (1GB, RAID 0/1/5/6)
RAID Controller (2GB, RAID 0/1/5/6)
RAID Controller (2GB, RAID0/1/5/6)
2.5-inch PCIeSSD Installation Kit
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
Dual Port InfiniBand Adapter
Single Port InfiniBand Adapter
SAS Controller
Dual Port 10GBASE-T Adapter
Dual Port 10GBASE-T Adapter
10GBASE SFP+ Adapter (SFP+/2ch)
Dual Port 10GBASE SFP+ Adapter
(SFP+/2ch)
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
SAS Controller
Quad Port 1000BASE-T Adapter
Dual Port 1000BASE-T Adapter
Dual Port 1000BASE-T Adapter
1000BASE-T Adapter
Serial Port Adapter
#1A #1B
#1C
#2C
#1D
#2D
#3D
-
(1)
(1)
(1)
-
-
-
-
-
(1)
(1)
(1)
-
(1)
-
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
-
-
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
-
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(3)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(3)
NOTE:

The slot #2C, #2D, and #3D are available in a dual-processor configuration.

Up to 312 mm / 12.28in length card can be installed into slot #2C when N8116-37 Full Length PCI
Card installation Kit is installed.

The number between parentheses shows the population priority (recommendation). For example,
install N8104-155F (1) in the slot #1B, N8103-176 (5) in the slot #1A, N8104-153 (16) in the slot #1C
and N8190-160 (19) in the slot #1D when you install those cards.

For VMware ESXi 5.5, there are some limitations as follows:
<With N8104-154F Quad Port 1000BASE-T LOM Card>
- N8104-149/-153/-157 and N8104-150/-151/-152 cannot be mixed.
- Up to one card among N8103-176/-177/-178/-179 can be installed.
- When configured with Xeon E5-2697v4/2697Av4/2698v4/2699v4,
a) Up to two cards among N8104-151/-152/-149/-153/-157 can be installed
b) Up to two cards among N8104-150/N8190-160/N8190-158A/N8103-184 can be installed
* Up to three cards when the above a) and b) are mixed
- When configured with Xeon E5-2603v4/E5-2620Av4/E5-2623v4/E5-2630v4/E5-2637v4/E5-2640v4/
E5-2643v4/E5-2650v4/2667v4/2680v4/2690v4,
c) Up to three cards among N8104-152/-149/-153/-157 can be installed
d) Up to six cards among N8104-150/N8104-151/N8190-160/N8190-158A/N8103-184 can be
installed
* When the above c) and d) are mixed, up to four cards can be installed.
<With N8104-155F Dual Port 10GBASE-T LOM Card>
- N8104-150/-151 and N8104-152 cannot be mixed.
NEC Corporation
Revision 1.1 – May, 2016
42
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M


- Up to two cards of N8104-150/-151 can be installed.
- Up to one card of N8104-152 can be installed.
- Up to one card among N8103-176/-177/-178/-179 can be installed.
- When configured with Xeon E5-2697v4/E5-2697Av4/E5-2698v4/E5-2699v4,
a) Up to two cards among N8104-151/-152/-149/-153/-157 can be installed
b) Up to two cards among N8104-150/N8190-160/N8190-158A/N8103-184 can be installed
* Up to three cards when the above a) and b) are mixed
- When configured with Xeon E5-2603v4/E5-2620Av4/E5-2623v4/E5-2630v4/E5-2637v4/E5-2640v4/
E5-2643v4/E5-2650v4/E5-2667v4/E5-2680v4/E5-2690v4,
c) Up to three cards among N8104-152/-149/-153/-157 can be installed
d) Up to six cards among N8104-150/N8104-151/N8190-160/N8190-158A/N8103-184 can be
installed
* When the above c) and d) are mixed, up to four cards can be installed.
<With N8104-156F Dual Port 10G-SFP + Dual Port 1000BASE-T LOM Card >
- Up to two cards of N8104-150/-151 can be installed.
- N8104-152 cannot be installed.
- Up to one card among N8103-176/-177/-178/-179 can be installed.
- When configured with Xeon E5-2697v4/E5-2697Av4/E5-2698v4/E5-2699v4,
a) Up to one card among N8104-151/-149/-153/-157 can be installed
b) Up to two cards among N8104-150/N8104-151/N8190-160/N8190-158A/N8103-184 can be
installed
* Up to two cards when the above a) and b) are mixed
- When configured with Xeon E5-2603v4/E5-2620Av4/E5-2623v4/E5-2630v4/E5-2637v4/E5-2640v4/
E5-2643v4/E5-2650v4/E5-2667v4/E5-2680v4/E5-2690v4,
c) Up to two cards among N8104-149/-153/-157 can be installed
d) Up to five cards among N8104-150/N8104-151/N8190-160/N8190-158A/N8103-184 can be
installed
* When the above c) and d) are mixed, up to four cards can be installed.
For VMware ESXi 6.0, there are some limitations as follows:
- With N8104-154F Quad Port 1000BASE-T LOM Card:
N8104-149/-153/-157 and N8104-150/-151/-152 cannot be mixed
- With N8104-155F Dual Port 10GBASE-T LOM Card:
N8104-150/-151 and N8104-152 cannot be mixed.
Up to two cards of N8104-150/-151 can be installed.
Up to one N8104-152 can be installed
- With N8104-156F Dual Port 10GBASE-T LOM Card:
Up to one of N8104-150/-151 can be installed.
N8104-152 cannot be installed.
For the configuration limitation for VMware ESXi, refer to the following documents.
VMware ESXi5.5
https://www.vmware.com/pdf/vsphere5/r55/vsphere-55-configuration-maximums.pdf
VMware ESXi6.0
https://www.vmware.com/pdf/vsphere6/r60/vsphere-60-configuration-maximums.pdf
NEC Corporation
Revision 1.1 – May, 2016
43
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
N8116-45 PCIe x4/x16 FH Riser Card Kit
Slots
Prio
rity
Part Number
(1)
(2)
(3)
N8104-155F
N8104-160F
N8104-156F
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
N8104-154F
N8103-176
N8103-177
N8103-178
N8103-179
N8118-301
N8190-158A
N8190-157A
N8104-147
N8104-146
N8103-184
N8104-157
N8104-153
N8104-149
N8104-148
(19)
(20)
(21)
(22)
(23)
(24)
(25)
(26)
N8190-160
N8190-159
N8103-142
N8104-152
N8104-145
N8104-151
N8104-150
N8117-01A
Product Name
Dual Port 10GBASE-T LOM Card
Dual Port 10GBASE-T LOM Card
Dual Port 10G-SFP + Dual Port
1000BASE-T LOM Card
Quad Port 1000BASE-T LOM Card
RAID Controller (1GB, RAID 0/1)
RAID Controller (1GB, RAID 0/1/5/6)
RAID Controller (2GB, RAID 0/1/5/6)
RAID Controller (2GB, RAID0/1/5/6)
2.5-inch PCIeSSD Installation Kit
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
Dual Port InfiniBand Adapter
Single Port InfiniBand Adapter
SAS Controller
Dual Port 10GBASE-T Adapter
Dual Port 10GBASE-T Adapter
10GBASE SFP+ Adapter (SFP+/2ch)
Dual Port 10GBASE SFP+ Adapter
(SFP+/2ch)
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
SAS Controller
Quad Port 1000BASE-T Adapter
Dual Port 1000BASE-T Adapter
Dual Port 1000BASE-T Adapter
1000BASE-T Adapter
Serial Port Adapter
#1A #1B #1C #2C #3C #1D #2D #3D
-
(1)
(1)
(1)
-
-
-
-
-
-
(1)
(1)
(1)
-
(1)
-
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
-
-
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
-
(4)
(4)
(4)
(4)
(4)
(4)
(4)
-
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(3)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(4)
NOTE:

The slot #3C, #2D, and #3D are available in a dual-processor configuration.

Up to 312 mm / 12.28in length card can be installed into slot #2C when N8116-37 Full Length PCI
Card installation Kit is installed.

The number between parentheses shows the population priority (recommendation). For example,
install N8104-155F (1) in the slot #1B, N8103-176 (5) in the slot #1A, N8104-153 (16) in the slot #1C
and N8190-160 (19) in the slot #1D when you install those cards.

For VMware ESXi 5.5, there are some limitations as follows:
<With N8104-154F Quad Port 1000BASE-T LOM Card>
- N8104-149/-153/-157 and N8104-150/-151/-152 cannot be mixed.
- Up to one card among N8103-176/-177/-178/-179 can be installed.
- When configured with Xeon E5-2697v4/2697Av4/2698v4/2699v4,
a) Up to two cards among N8104-151/-152/-149/-153/-157 can be installed
b) Up to two cards among N8104-150/N8190-160/N8190-158A/N8103-184 can be installed
* Up to three cards when the above a) and b) are mixed
- When configured with Xeon E5-2603v4/E5-2620Av4/E5-2623v4/E5-2630v4/E5-2637v4/E5-2640v4/
E5-2643v4/E5-2650v4/2667v4/2680v4/2690v4,
c) Up to three cards among N8104-152/-149/-153/-157 can be installed
d) Up to six cards among N8104-150/N8104-151/N8190-160/N8190-158A/N8103-184 can be
installed
* When the above c) and d) are mixed, up to four cards can be installed.
<With N8104-155F Dual Port 10GBASE-T LOM Card>
- N8104-150/-151 and N8104-152 cannot be mixed.
NEC Corporation
Revision 1.1 – May, 2016
44
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M


- Up to two cards of N8104-150/-151 can be installed.
- Up to one card of N8104-152 can be installed.
- Up to one card among N8103-176/-177/-178/-179 can be installed.
- When configured with Xeon E5-2697v4/E5-2697Av4/E5-2698v4/E5-2699v4,
a) Up to two cards among N8104-151/-152/-149/-153/-157 can be installed
b) Up to two cards among N8104-150/N8190-160/N8190-158A/N8103-184 can be installed
* Up to three cards when the above a) and b) are mixed
- When configured with Xeon E5-2603v4/E5-2620Av4/E5-2623v4/E5-2630v4/E5-2637v4/E5-2640v4/
E5-2643v4/E5-2650v4/E5-2667v4/E5-2680v4/E5-2690v4,
c) Up to three cards among N8104-152/-149/-153/-157 can be installed
d) Up to six cards among N8104-150/N8104-151/N8190-160/N8190-158A/N8103-184 can be
installed
* When the above c) and d) are mixed, up to four cards can be installed.
<With N8104-156F Dual Port 10G-SFP + Dual Port 1000BASE-T LOM Card >
- Up to two cards of N8104-150/-151 can be installed.
- N8104-152 cannot be installed.
- Up to one card among N8103-176/-177/-178/-179 can be installed.
- When configured with Xeon E5-2697v4/E5-2697Av4/E5-2698v4/E5-2699v4,
a) Up to one card among N8104-151/-149/-153/-157 can be installed
b) Up to two cards among N8104-150/N8104-151/N8190-160/N8190-158A/N8103-184 can be
installed
* Up to two cards when the above a) and b) are mixed
- When configured with Xeon E5-2603v4/E5-2620Av4/E5-2623v4/E5-2630v4/E5-2637v4/E5-2640v4/
E5-2643v4/E5-2650v4/E5-2667v4/E5-2680v4/E5-2690v4,
c) Up to two cards among N8104-149/-153/-157 can be installed
d) Up to five cards among N8104-150/N8104-151/N8190-160/N8190-158A/N8103-184 can be
installed
* When the above c) and d) are mixed, up to four cards can be installed.
For VMware ESXi 6.0, there are some limitations as follows:
- With N8104-154F Quad Port 1000BASE-T LOM Card:
N8104-149/-153/-157 and N8104-150/-151/-152 cannot be mixed
- With N8104-155F Dual Port 10GBASE-T LOM Card:
N8104-150/-151 and N8104-152 cannot be mixed.
Up to two cards of N8104-150/-151 can be installed.
Up to one N8104-152 can be installed
- With N8104-156F Dual Port 10GBASE-T LOM Card:
Up to one of N8104-150/-151 can be installed.
N8104-152 cannot be installed.
For the configuration limitation for VMware ESXi, refer to the following documents.
VMware ESXi5.5
https://www.vmware.com/pdf/vsphere5/r55/vsphere-55-configuration-maximums.pdf
VMware ESXi6.0
https://www.vmware.com/pdf/vsphere6/r60/vsphere-60-configuration-maximums.pdf
NEC Corporation
Revision 1.1 – May, 2016
45
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
N8116-49 PCIe x4/x16 FH/LP Riser Card Kit or
N8116-45 PCIe x4/x16 FH Riser Card Kit plus N8116-46 PCIe x4/x16 LP Riser Card
Kit
Slots
Prio
rity
Part Number
(1)
(2)
(3)
N8104-155F
N8104-160F
N8104-156F
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
N8104-154F
N8103-176
N8103-177
N8103-178
N8103-179
N8118-301
N8190-158A
N8190-157A
N8104-147
N8104-146
N8103-184
N8104-157
N8104-153
N8104-149
N8104-148
(19)
(20)
(21)
(22)
(23)
(24)
(25)
(26)
N8190-160
N8190-159
N8103-142
N8104-152
N8104-145
N8104-151
N8104-150
N8117-01A
Product Name
Dual Port 10GBASE-T LOM Card
Dual Port 10GBASE-T LOM Card
Dual Port 10G-SFP + Dual Port
1000BASE-T LOM Card
Quad Port 1000BASE-T LOM Card
RAID Controller (1GB, RAID 0/1)
RAID Controller (1GB, RAID 0/1/5/6)
RAID Controller (2GB, RAID 0/1/5/6)
RAID Controller (2GB, RAID0/1/5/6)
2.5-inch PCIeSSD Installation Kit
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
Dual Port InfiniBand Adapter
Single Port InfiniBand Adapter
SAS Controller
Dual Port 10GBASE-T Adapter
Dual Port 10GBASE-T Adapter
10GBASE SFP+ Adapter (SFP+/2ch)
Dual Port 10GBASE SFP+ Adapter
(SFP+/2ch)
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
SAS Controller
Quad Port 1000BASE-T Adapter
Dual Port 1000BASE-T Adapter
Dual Port 1000BASE-T Adapter
1000BASE-T Adapter
Serial Port Adapter
#1A #1B #1C #2C #3C #1D #2D #3D
-
(1)
(1)
(1)
-
-
-
-
-
-
(1)
(1)
(1)
-
(1)
-
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
-
-
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
-
(4)
(4)
(4)
(4)
(4)
(4)
(4)
-
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(3)
(6)
(6)
(6)
(6)
(6)
(6)
(6)
(4)
NOTE:

The slot #3C and #3D are available in a dual-processor configuration.

Up to 312 mm / 12.28in length card can be installed into slot #2C when N8116-37 Full Length PCI
Card installation Kit is installed.

The number between parentheses shows the population priority (recommendation). For example,
install N8104-155F (1) in the slot #1B, N8103-176 (5) in the slot #1A, N8104-153 (16) in the slot #1C
and N8190-160 (19) in the slot #1D when you install those cards.

For VMware ESXi 5.5, there are some limitations as follows:
<With N8104-154F Quad Port 1000BASE-T LOM Card>
- N8104-149/-153/-157 and N8104-150/-151/-152 cannot be mixed.
- Up to one card among N8103-176/-177/-178/-179 can be installed.
- When configured with Xeon E5-2697v4/2697Av4/2698v4/2699v4,
a) Up to two cards among N8104-151/-152/-149/-153/-157 can be installed
b) Up to two cards among N8104-150/N8190-160/N8190-158A/N8103-184 can be installed
* Up to three cards when the above a) and b) are mixed
- When configured with Xeon E5-2603v4/E5-2620Av4/E5-2623v4/E5-2630v4/E5-2637v4/E5-2640v4/
E5-2643v4/E5-2650v4/2667v4/2680v4/2690v4,
c) Up to three cards among N8104-152/-149/-153/-157 can be installed
d) Up to six cards among N8104-150/N8104-151/N8190-160/N8190-158A/N8103-184 can be
installed
NEC Corporation
Revision 1.1 – May, 2016
46
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M


* When the above c) and d) are mixed, up to four cards can be installed.
<With N8104-155F Dual Port 10GBASE-T LOM Card>
- N8104-150/-151 and N8104-152 cannot be mixed.
- Up to two cards of N8104-150/-151 can be installed.
- Up to one card of N8104-152 can be installed.
- Up to one card among N8103-176/-177/-178/-179 can be installed.
- When configured with Xeon E5-2697v4/E5-2697Av4/E5-2698v4/E5-2699v4,
a) Up to two cards among N8104-151/-152/-149/-153/-157 can be installed
b) Up to two cards among N8104-150/N8190-160/N8190-158A/N8103-184 can be installed
* Up to three cards when the above a) and b) are mixed
- When configured with Xeon E5-2603v4/E5-2620Av4/E5-2623v4/E5-2630v4/E5-2637v4/E5-2640v4/
E5-2643v4/E5-2650v4/E5-2667v4/E5-2680v4/E5-2690v4,
c) Up to three cards among N8104-152/-149/-153/-157 can be installed
d) Up to six cards among N8104-150/N8104-151/N8190-160/N8190-158A/N8103-184 can be
installed
* When the above c) and d) are mixed, up to four cards can be installed.
<With N8104-156F Dual Port 10G-SFP + Dual Port 1000BASE-T LOM Card >
- Up to two cards of N8104-150/-151 can be installed.
- N8104-152 cannot be installed.
- Up to one card among N8103-176/-177/-178/-179 can be installed.
- When configured with Xeon E5-2697v4/E5-2697Av4/E5-2698v4/E5-2699v4,
a) Up to one card among N8104-151/-149/-153/-157 can be installed
b) Up to two cards among N8104-150/N8104-151/N8190-160/N8190-158A/N8103-184 can be
installed
* Up to two cards when the above a) and b) are mixed
- When configured with Xeon E5-2603v4/E5-2620Av4/E5-2623v4/E5-2630v4/E5-2637v4/E5-2640v4/
E5-2643v4/E5-2650v4/E5-2667v4/E5-2680v4/E5-2690v4,
c) Up to two cards among N8104-149/-153/-157 can be installed
d) Up to five cards among N8104-150/N8104-151/N8190-160/N8190-158A/N8103-184 can be
installed
* When the above c) and d) are mixed, up to four cards can be installed.
For VMware ESXi 6.0, there are some limitations as follows:
- With N8104-154F Quad Port 1000BASE-T LOM Card:
N8104-149/-153/-157 and N8104-150/-151/-152 cannot be mixed
- With N8104-155F Dual Port 10GBASE-T LOM Card:
N8104-150/-151 and N8104-152 cannot be mixed.
Up to two cards of N8104-150/-151 can be installed.
Up to one N8104-152 can be installed
- With N8104-156F Dual Port 10GBASE-T LOM Card:
Up to one of N8104-150/-151 can be installed.
N8104-152 cannot be installed.
For the configuration limitation for VMware ESXi, refer to the following documents.
VMware ESXi5.5
https://www.vmware.com/pdf/vsphere5/r55/vsphere-55-configuration-maximums.pdf
VMware ESXi6.0
https://www.vmware.com/pdf/vsphere6/r60/vsphere-60-configuration-maximums.pdf
NEC Corporation
Revision 1.1 – May, 2016
47
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Copyright Notice and Liability Disclaimer
The information contained herein is subject to change without notice.
Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in
the United States and/or other countries
Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United
States and other countries.
Linux is a trademark of Linus Torvalds.
Red Hat is a registered trademark of Red Hat, Inc. in the U.S.
All other products, brands, or trade names used in this document are trademarks or registered trademarks
of their respective holders.
NEC shall not be liable for technical or editorial errors or omissions contained herein.
For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.
NEC Corporation
Revision 1.1 – May, 2016
48
SYSTEM CONFIGURATION GUIDE – NEC Express5800/R120g-2M
Revision History
Revision
Date
Description
1.1
May 17, 2016
1.0
April 25, 2016
Others:
Added DVD read speed information
Initial release
NEC Corporation
Revision 1.1 – May, 2016
49