6073403020en

Technical Data
Plastic bodied limit switch
Series TI2 - ASI
Description
Article number
ASI TI2 HW
6073403020
Operating symbol
Fixed positioning for
safety applications
Mounting screw
according to DIN 912 M5
Operating diagram
On
Off
Tolerance:
Operating point ± 0,25 mm;
Operating force ± 10 %
Electrical data
Operating voltage
Operating current
AS-i Specifications
AS-i Inputs
Parameter bits
AS-i Address
U
I
26,5 … 31,6 V; via AS-interface, reverse-polarity proof
< 30 mA
Profile S-0.B
IO-Code: 0x0
ID-Code: 0xB
ID-Code1: 0xF
ID-Code2: 0xF
Contact 1: Date bits D0/D1 = static 00
or dynamic code transmission
Contact 2: Date bits D2/D3 = static 00
or dynamic code transmission
no function
preset address: 0
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 07.07.2011 / Page 1 of 2
Document : 6073403020_en / Last update : 1 / 2366-11
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu
Vorlage : 0850174281 Orig. 1
Technical Data
Plastic bodied limit switch
Mechanical data
Enclosure
Cover
Indication
Actuator
Ambient air temperature
Contact type
Mechanical life
Switching frequency
Assembly
Connection
Plug connection
Weight
Installation position
Protection type
PBT, glass fibre reinforced
PA 6.6, black
LEDs for slave and bus state
Lever with roller (thermoplastic)
-25° C … +70° C
2 NC (slow-action, Zb)
3 x 106 switching cycles
≤ 100/min
2 x M4
Plug connector M12 male
1: AS-i +
2: free
3: AS-i 4: free
≈ 0,05 kg
operator definable
IP65 acc. to EN 60529; DIN VDE 0470 T1
Actuation
The push bolt actuator is mainly intended to be actuated along its axis.
Side actuation will considerably reduce switch life.
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
EN 50295, EN ISO 13849-1
EU Conformity
acc. to EMC Directive
Safety Classification
according 13849-1 to PL e
MTTFd = high
PFD
= 2,49 * 10-10
Notes
The degree of protection specified (IP code) applies only to a properly closed cover and the use of an equivalent
connector.
This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims
for defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications
subject to change without notice!
Date of issue: 07.07.2011 / Page 2 of 2
Document : 6073403020_en / Last update : 1 / 2366-11
Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica / www.bernstein.eu
Vorlage : 0850174281 Orig. 1