BF Inline Data Sheet

Cable Fuses
BF-INLINE FUSE RATED 32V
Specifications
Voltage Rating:
32 VDC
Housing:
Out of thermoplastic
heat-resistant
Terminals: Crimp, Copper alloy, tinned
Interrupting Rating:
2000A @32VDC
Ordering Information
Part Number
Package Size
153.xxxx
300
Time-Current Characteristics 100A-190A
% of Rating
Description
Inline fuse to protect specific cable cross-sections and insulations;
Cross-section 10mm² to 35mm². For rated voltage up to 32 VDC.
Assembly notes: The wire integrated fuse has to be insulated by
using a self-adhesive shrinking tube. The wire has to be fixed on
both sides of the fuse to minimize the wire forces. Recommended
shrinking tube: DERAY(R)-IAKT 4:1, 24mm
Opening Time Min / Max (s)
100
360,000 s
–
165
10 s
100 s
200
3s
240 s
300
0.3 s
60 s
500
0.1 s
10 s
Time-Current Characteristics 300A
Pre-Arcing Time-Limits
FI = 1,25 (max. operating current:
0,8 x Irat at 23°C)
% of Rating
Opening Time Min / Max (s)
75
360,000 s
–
165
10 s
100 s
200
1s
15 s
350
0.3 s
5s
500
0.1 s
1s
Ratings
Part Number
Current Rating
Wire Size/Type/Marking
Typ. Voltage Drop
Cold Resistance
I2t
153.1002
100 A
10mm²/FLY/P
60 mV
0.42 mΩ
26.000 A²s
153.1012
125 A
10mm²/FL2G/S
70 mV
0.32 mΩ
86.000 A²s
153.1602
125 A
16mm²/FLY/P
75 mV
0.41 mΩ
28,000 A²s
153.1612
170 A
16mm²/FL2G/S
60 mV
0.22 mΩ
250,000 A²s
153.2502
170 A
25mm²/FLY/P
70 mV
0.29 mΩ
75,000 A²s
153.2512
190 A
25mm²/FL2G/S
52 mV
0.18mΩ
610,000 A²s
153.3502
300 A
35mm²/FLY/P
70 mV
0.20 mΩ
589.500 A²s
© 2012 Littelfuse • Transportation Products Catalog