BPM15 Series
www.murata-ps.com
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
Typical unit
FEATURES
PRODUCT OVERVIEW

Five-sided shielded metal package reduces
radiated emissions
Featuring a full 15 Watt output in one square
inch of board area, the BPM15 series isolated
DC-DC converter family offers efficient regulated
DC power for printed circuit board mounting. The
wide range 4:1 inputs on the 1" x 1" x 0.40" (25.4
x 25.4 x 10.16mm) converter are either 9 to 36
Volts DC (Q12 models) or 18 to 75 Volts DC (Q48
models), ideal for battery-powered and telecom
equipment. The industry-standard pinout fits larger
1" x 2" converters. Fixed output voltages of ±5,
±12 or ±15 VDC are regulated to within ±0.25%.
Applications include small instruments, arealimited microcontrollers, data communications
equipment, remote sensor systems, vehicle and
portable electronics.
The rugged mechanical, thermal, and electrical
design of this product is intended for high reliability
and harsh environments.

Industry standard 1" x 1" x 0.40"
encapsulated package and pinout

Wide range input voltages 9-36 and
18-75 Vdc

Bipolar ±5V, ±12V and ±15V outputs

Up to 15 Watts or greater total output
power with overtemperature shutdown

Isolation up to 1600 VDC (basic)

High efficiency flyback topology

Usable -40 to 85°C temperature range
(with derating)

Assembly and attachment for RoHS standards

Extensive self-protection shut down
features
The BPM15 series includes full magnetic and
optical isolation with Basic protection up to 1600
Volts DC. For powering digital systems, the outputs
offer fast settling to step transients and will accept
higher capacitive loads. Excellent ripple and noise
specifications assure compatibility to noise-susceptible circuits. For systems requiring controlled
startup/shutdown, an external remote On/Off
control may use a switch, transistor or digital logic.
A wealth of self-protection features avoid both
converter and external circuit faults. These include
input undervoltage lockout and overtemperature
shutdown. The outputs current limit using the
“hiccup” autorestart technique and the outputs
are short-circuit protected. Additional features
include output overvoltage and reverse conduction
elimination. The high efficiency offers minimal heat
buildup and “no fan” operation.

Meets UL 60950-1, CAN/CSA-C22.2 No.
60950-1, IEC60950-1, EN60950-1 safety
approvals (2nd Edition)
CONNECTION DIAGRAM
*TPMBUJPO
Barrier
+Vin (1)
F1
External
DC
Power
Source
On/Off
Control
(3)
Open = On
$MPTFE0GG
1PTJUJWF
MPHJD
Controller
and
Power
5SBOTGFS
t4XJUDIJOH
t'JMUFST
+Vout (6)
Common (5)
t4XJUDIJOH
t'JMUFST
-Vout (4)
Reference and
Error Amplifier
-Vin (2)
Typical topology is shown.
For full details go to
www.murata-ps.com/rohs
Murata Power Solutions recommends a fuse at F1.
www.murata-ps.com/support
MDC_BPM15.A02 Page 1 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE ➀
Output
R/N (mVp-p) Regulation (Max.)
IOUT
Total
VOUT
(mA,
Power
Typ. Max.
Line
Load ➄
Root Models ➀
(V) max.) ➁ (W)
Input
IIN =
VIN
minimum
Nom. Range
load
(mA)
(V)
(V)
IIN =
full
load
(mA)
Efficiency
Min.
Typ.
BPM15-050-Q12
±5
±1500
15
60
100
±0.25%
±0.25%
24
9-36
90
740
82.5%
84%
BPM15-050-Q48
±5
±1500
15
60
100
±0.25%
±0.25%
48
18-75
50
384
80%
81.4%
BPM15-120-Q12
±12
±625
15
80
120
±0.25%
±0.25%
24
9-36
95
740
82%
84%
BPM15-120-Q48
±12
±625
15
80
120
±0.25%
±0.25%
48
18-75
50
368
83%
85%
BPM15-150-Q12
±15
±500
15
60
100
±0.25%
±0.25%
24
9-36
100
740
82.5%
84.5%
BPM15-150-Q48
±15
±500
15
80
120
±0.25% ±0.275%
48
18-75
50
360
83%
86%
➀ Please refer to the part number structure for additional options and complete
ordering part numbers.
➁ The minimum output load for the BPM15 series is 10% of maximum current to
meet published specifications. The converter will not be damaged by less than
10% load but some specs may degrade slightly.
➂ All specifications are at nominal line voltage and full load, +25 °C. unless otherwise noted. See detailed specifications and notes for full conditions.
Encapsulated
Package
(inches)
(mm)
1 x 1 x 0.40
25.4 x 25.4 x 10.16
Output capacitors are 1 μF ceramic in parallel with 10 μF. The input cap is 100 μF,
low ESR electrolytic.
I/O caps are necessary for our test equipment and may not be needed for your
application.
➃ RoHS-6 compliance does not claim EU RoHS exemption 7b (lead in solder).
➄ Balanced loads, 10% to 100% loads.
PART NUMBER STRUCTURE
BPM15 - 050 - Q48 P Lx - C
Bipolar Wide Input
15-Watt Series
Nominal Output Voltage
in Tenths of a Volt
Input Voltage Range
Q12 = 9-36V
Q48 = 18-75V
RoHS-6 Hazardous
Substance Compliance (note 4)
Pin Length Option
Blank = Std. pin length 0.25˝ (6.3mm)
L1 = 0.110˝ (2.79mm)
L2 = 0.145˝ (3.68mm)
*
*
On/Off Control Logic
P = Positive
N = Negative
Blank = Control pin omitted‡
*Minimum order quantity is required.
Samples available with standard pin
length only.
‡Some model number combinations may not
be available. See website or contact your local
Murata sales representative.
www.murata-ps.com/support
MDC_BPM15.A02 Page 2 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
FUNCTIONAL SPECIFICATIONS, BPM15-050-Q12
ABSOLUTE MAXIMUM RATINGS
Input Voltage, Continuous
Input Voltage, Transient
Isolation Voltage
On/Off Remote Control
Output Power
Conditions ➀
100 mS max. duration
Input to output
Power on, referred to -Vin
Minimum
0
0
1.48
Typical/Nominal
Maximum
36
50
1600
15
15.15
Units
Vdc
Vdc
Vdc
Vdc
W
Current-limited, no damage, short-circuit
0.15
1.5
A
protected
Storage Temperature Range
Vin = Zero (no power)
-55
125
˚C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other
than those listed in the Performance/Functional Specifications Table is not implied or recommended.
INPUT
Operating Voltage Range
9
24
36
Vdc
Recommended External Fuse
Fast blow
4
A
Start-up Threshold
Rising input voltage
8
8.5
9
Vdc
Undervoltage Shutdown (50% load)
Falling input voltage
7.7
8.2
8.7
Vdc
Internal Filter Type
C
Input Current
Full Load Input Current
Vin = nominal
0.74
0.77
A
Low Line Input Current
Vin = minimum
2.03
2.09
A
Inrush Transient
0.05
A2-Sec.
Short Circuit Input Current
0.05
0.1
A
Minimum Load Input Current
Iout = minimum, unit = ON
90
150
mA
Shut-Down Input Current (Off, UV, OT)
1
2
mA
Measured at input with specified filter
25
mA, p-p
Reflected (Back) Ripple Current ➁
GENERAL and SAFETY
Vin = 24V, full load
82.5
84
%
Efficiency
Vin = min., full load
80.5
82
%
Isolation
Isolation Voltage
Input to output
1600
Vdc
Isolation Resistance
10
MΩ
Isolation Capacitance
1000
pF
Certified to UL-60950-1, CSA-C22.2 No.
Safety
Approved
60950-1, IEC/60950-1, 2nd edition, with AM1
Per Telcordia SR332, issue 1, class 3, ground
Calculated MTBF
5.8
Hours x 106
fixed, Tambient = +25°C
DYNAMIC CHARACTERISTICS
Fixed Switching Frequency
330
360
390
KHz
Startup Time
Power on to Vout regulated
50
mS
Startup Time
Remote ON to Vout regulated
50
mS
50-75-50% load step, settling time to within
Dynamic Load Response
250
300
μSec
1% of Vout
Dynamic Load Peak Deviation
same as above
±100
±150
mV
FEATURES and OPTIONS
Remote On/Off Control ➂
“N” suffix
Negative Logic, ON state
ON = Ground pin
-0.7
0.8
V
Negative Logic, OFF state
OFF = Pin open
10
15
V
Control Current
Open collector/drain
1
mA
“P” suffix
Positive Logic, ON state
ON = Pin open
10
15
V
Positive Logic, OFF state
OFF = Ground pin
-0.7
0.8
V
Control Current
Open collector/drain
1
mA
Output Current
www.murata-ps.com/support
MDC_BPM15.A02 Page 3 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
FUNCTIONAL SPECIFICATIONS, BPM15-050-Q12 (CONT.)
OUTPUT
Total Output Power
Voltage
Nominal Output Voltage
Setting Accuracy
Overvoltage Protection
Current
Output Current Range
Current Limit Inception
Short Circuit
Short Circuit Current
Short Circuit Duration (remove short
for recovery)
Short circuit protection method
Regulation
Line Regulation
Load Regulation
Ripple and Noise
Maximum Capacitive Loading
MECHANICAL
Outline Dimensions
(Please refer to outline drawing)
Weight
Conditions ➀ ➂
Minimum
1.48
Typical/Nominal
15
Maximum
15.15
Units
W
No trim
At 50% load, no trim
Via magnetic feedback
±4.95
±5.05
5.6
±5
±1
6.5
7
Vdc
% of Vnom
Vdc
±0.15
±1.65
±1.5
±2.8
±1.5
±3.3
A
A
0.3
A
±0.25
±0.25
100
520
% of Vout
% of Vout
mV pk-pk
μF
98% of Vnom., after warmup
Hiccup technique, autorecovery within
±1.25% of Vout
Output shorted to ground, no damage
Continuous
Current limiting
Vin = min. to max., Vout = nom., Iout = nom.
Iout = min. to max., Vin = 24V
5 Hz - 20 MHz BW, Vin = 24V
Low ESR, 0.02 Ω max
60
1 x 1 x 0.40
25.4 x 25.4 x 10.16
0.69
19.56
0.04
1.016
Copper alloy
50
5
WxLxH
Through Hole Pin Diameter
Through Hole Pin Material
TH Pin Plating Metal and Thickness
ENVIRONMENTAL
Operating Ambient Temperature Range
Operating Case Temperature Range
Case Material
Storage Temperature
Thermal Protection/Shutdown
Electromagnetic Interference
Conducted, EN55022/CISPR22
RoHS rating
Notes
Nickel subplate
Gold overplate
See derating
No derating
Tin plated steel with black powder coat
Vin = Zero (no power)
Measured in center
External filter is required
➀ Unless otherwise noted, all specifications are at nominal input voltage, nominal output voltage and
full load. General conditions are +25˚ Celsius ambient temperature, near sea level altitude, natural
convection airflow. All models are tested and specified with external parallel 1 μF and 10 μF output
capacitors. The external input capacitor is 100 μF, electrolytic.
-40
-40
-55
120
130
B
RoHS-6
Inches
mm
Ounces
Grams
Inches
mm
μ-inches
μ-inches
85
93
°C
°C
125
140
°C
°C
Class
➁ Input (back) ripple current is tested and specified over 5 Hz to 20 MHz bandwidth. Input filtering is
Cbus = 220 μF, Cin = 33 μF and Lbus = 12 μH.
➂ The Remote On/Off Control is referred to -Vin.
www.murata-ps.com/support
MDC_BPM15.A02 Page 4 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
PERFORMANCE DATA, BPM15-050-Q12
Efficiency vs. Line Voltage and Load Current @ +25°C
Power Dissipation vs. Line Voltage and Load Current @ +25°C
85
3.5
83
3.0
81
Power Dissipation (Watts)
Efficiency (%)
79
77
Vin=9V
75
Vin=12V
73
Vin=24V
71
2.5
2.0
Vin=9V
1.5
Vin=12V
1.0
Vin=24V
Vin=36V
69
Vin=36V
0.5
67
65
0.16
0.0
0.16
0.31
0.46
0.61
0.76
0.91
1.06
1.21
1.36
0.31
0.46
1.51
0.61
0.76
0.91
1.06
Output Load Curre nt (Amps)
1.21
1.36
1.51
Load Curre nt (Amps)
Maximum Current Temperature Derating at Sea Level
(VIN = 9V, airflow is from pin 1 to pin 4)
Maximum Current Temperature Derating at Sea Level
(VIN = 12V, airflow is from pin 1 to pin 4)
1.5
1.5
1.4
1.4
1.3
1.3
0.5 m/s (100 LFM)
0.33 m/s (65 LFM)
1.1
Output Current (A)
Output Current (A)
0.33 m/s (65 LFM)
1.2
1.2
0.5 m/s (100 LFM)
1
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
0.9
2.0 m/s (400 LFM)
1.1
1.0 m/s (200 LFM)
1
1.5 m/s (300 LFM)
2.0 m/s (400 LFM)
0.9
0.8
0.8
0.7
0.7
0.6
0.6
0.5
0.5
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
www.murata-ps.com/support
MDC_BPM15.A02 Page 5 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
PERFORMANCE DATA, BPM15-050-Q12
Maximum Current Temperature Derating at Sea Level
(VIN = 18V, airflow is from pin 1 to pin 24)
Maximum Current Temperature Derating at Sea Level
(VIN = 24V, airflow is from pin 1 to pin 4)
1.5
1.5
1.4
1.4
1.3
1.3
1.2
0.33 m/s (65 LFM)
0.33 m/s (65 LFM)
1.1
Output Current (A)
Output Current (A)
1.2
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1
1.5 m/s (300 LFM)
0.9
2.0 m/s (400 LFM)
0.8
1.1
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1
1.5 m/s (300 LFM)
2.0 m/s (400 LFM)
0.9
0.8
0.7
0.7
0.6
0.6
0.5
0.5
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
30
Maximum Current Temperature Derating at Sea Level
(VIN = 30V, airflow is from pin 1 to pin 4)
35
40
45
55
60
65
Ambient Temperature (ºC)
70
75
80
85
80
85
Maximum Current Temperature Derating at Sea Level
(VIN = 36V, airflow is from pin 1 to pin 4)
1.5
1.5
1.4
1.4
1.3
1.3
1.2
1.2
0.33 m/s (65 LFM)
1.1
Output Current (A)
0.33 m/s (65 LFM)
Output Current (A)
50
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1
1.5 m/s (300 LFM)
0.9
2.0 m/s (400 LFM)
1.1
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1
1.5 m/s (300 LFM)
2.0 m/s (400 LFM)
0.9
0.8
0.8
0.7
0.7
0.6
0.6
0.5
0.5
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
www.murata-ps.com/support
MDC_BPM15.A02 Page 6 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
FUNCTIONAL SPECIFICATIONS, BPM15-120-Q12
ABSOLUTE MAXIMUM RATINGS
Input Voltage, Continuous
Input Voltage, Transient
Isolation Voltage
On/Off Remote Control
Output Power
Output Current
Storage Temperature Range
Conditions ➀
100 mS max. duration
Input to output
Power on, referred to -Vin
Current-limited, no damage, short-circuit
protected
Vin = Zero (no power)
Minimum
0
Fast blow
Rising input voltage
Falling input voltage
9
8
7.7
24
8.5
8.2
C
36
4
9
8.7
Vdc
A
Vdc
Vdc
Vin = nominal
Vin = minimum
Iout = minimum, unit=ON
Measured at input with specified filter
0.74
1.98
0.05
0.05
95
1
30
0.77
2.05
0.1
125
2
A
A
Vin = 24V, full load
Vin = min., full load
82
82
84.3
84
%
%
MΩ
pF
Maximum
36
50
1600
15
15.15
Units
1.48
Typical/Nominal
0.0625
0.625
A
0
Vdc
Vdc
Vdc
Vdc
W
-55
125
˚C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those
listed in the Performance/Functional Specifications Table is not implied or recommended.
INPUT
Operating Voltage Range
Recommended External Fuse
Start-up Threshold
Undervoltage Shutdown (50% load)
Internal Filter Type
Input Current
Full Load Input Current
Low Line Input Current
Inrush Transient
Short Circuit Input Current
No Load Input Current
Shut-Down Input Current (Off, UV, OT)
Reflected (Back) Ripple Current ➁
A2-Sec.
A
mA
mA
mA, p-p
GENERAL and SAFETY
Efficiency
Isolation
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Safety
Calculated MTBF
DYNAMIC CHARACTERISTICS
Fixed Switching Frequency
Startup Time
Startup Time
Dynamic Load Response
Dynamic Load Peak Deviation
FEATURES and OPTIONS
Remote On/Off Control ➂
“N” suffix
Negative Logic, ON state
Negative Logic, OFF state
Control Current
“P” suffix
Positive Logic, ON state
Positive Logic, OFF state
Control Current
Input to output
Certified to UL-60950-1, CSA-C22.2 No.
60950-1, IEC/60950-1, 2nd edition, with AM1
Per Telcordia SR332, issue 1, class 3, ground
fixed, Tambient = +25°C
10
600
1600
Approved
7
Power on to Vout regulated
Remote ON to Vout regulated
50-75-50% load step, settling time to within
1% of Vout
same as above
295
325
Vdc
Hours x 106
355
50
60
KHz
mS
mS
250
300
μSec
±150
±250
mV
ON = Ground pin
OFF = Pin open
Open collector/drain
-0.7
10
1
0.8
15
V
V
ON = Pin open
OFF = Ground pin
Open collector/drain
10
-0.7
1
15
0.8
mA
V
V
mA
www.murata-ps.com/support
MDC_BPM15.A02 Page 7 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
FUNCTIONAL SPECIFICATIONS, BPM15-120-Q12 (CONT.)
OUTPUT
Total Output Power
Voltage
Nominal Output Voltage
Setting Accuracy
Overvoltage Protection
Current
Output Current Range
Current Limit Inception
Short Circuit
Short Circuit Current
Short Circuit Duration (remove short
for recovery)
Short circuit protection method
Regulation
Line Regulation
Load Regulation
Ripple and Noise
Maximum Capacitive Loading
MECHANICAL
Outline Dimensions
(Please refer to outline drawing)
Weight
Through Hole Pin Diameter
Through Hole Pin Material
TH Pin Plating Metal and Thickness
ENVIRONMENTAL
Operating Ambient Temperature Range
Operating Case Temperature Range
Case Material
Storage Temperature
Thermal Protection/Shutdown
Electromagnetic Interference
Conducted, EN55022/CISPR22
RoHS rating
Notes
Conditions ➀ ➂
Minimum
1.48
Typical/Nominal
15
Maximum
15.15
Units
No trim
At 50% load, no trim
Via magnetic feedback
±11.88
±12.12
15
±12
±1 16
16.5
Vdc
% of Vnom
Vdc
98% of Vnom., after warmup
±0.0625
±0.75
±0.625
±1.025
±0.625
±1.30
A
A
Hiccup technique, autorecovery within
±1.25% of Vout
0.3
A
W
Output shorted to ground, no damage
Continuous
Current limiting
Vin = min. to max., Vout = nom., Iout = nom.
Iout = min. to max., Vin = 24V
5 Hz- 20 MHz BW, Vin = 24V
Low ESR, 0.02 ohms max
80
±0.25
±0.25
120
520
% of Vout
% of Vout
mV pk-pk
μF
WxLxH
Nickel subplate
Gold overplate
1 x 1 x 0.40
25.4 x 25.4 x 10.16
0.69
19.56
0.04
1.016
Copper alloy
50
5
Inches
mm
Ounces
Grams
Inches
mm
μ-inches
μ-inches
See derating
No derating
Tin plated steel with black powder coat
Vin = Zero (no power)
Measured in center
External filter is required
-40
-40
130
B
RoHS-6
85
108
125
140
°C
°C
➀ Unless otherwise noted, all specifications are at nominal input voltage, nominal output voltage and
full load. General conditions are +25˚ Celsius ambient temperature, near sea level altitude, natural
convection airflow. All models are tested and specified with external parallel 1 μF and 10 μF output
capacitors. The external input capacitor is 100 μF.
-55
120
°C
°C
Class
➁ Input (back) ripple current is tested and specified over 5 Hz to 20 MHz bandwidth. Input filtering is
Cbus = 220 μF, Cin = 33 μF and Lbus = 12 μH.
➂ The Remote On/Off Control is referred to -Vin.
www.murata-ps.com/support
MDC_BPM15.A02 Page 8 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
PERFORMANCE DATA, BPM15-120-Q12
Efficiency vs. Line Voltage and Load Current @ +25°C
Power Dissipation vs. Line Voltage and Load Current @ +25°C
85
3.5
83
3.0
81
Power Dissipation (Watts)
Efficiency (%)
79
77
Vin=9V
75
Vin=12V
73
Vin=24V
71
2.5
2.0
1.5
Vin=9V
Vin=12V
1.0
Vin=24V
Vin=36V
69
Vin=36V
0.5
67
0.0
0.06
65
0.06
0.13
0.19
0.25
0.31
0.38
0.44
0.50
0.57
0.13
0.19
0.25
0.63
0.31
0.38
0.44
0.50
0.57
0.63
Output Load Curre nt (Amps)
Load Curre nt (Amps)
Maximum Current Temperature Derating at Sea Level
(VIN = 9V, airflow is from pin 1 to pin 4)
Maximum Current Temperature Derating at Sea Level
(VIN = 12V, airflow is from pin 1 to pin 4)
0.7
0.7
0.6
0.6
0.5
0.5
0.33 m/s (65 LFM)
Output Current (A)
Output Current (A)
0.33 m/s (65 LFM)
0.5 m/s (100 LFM)
0.4
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
0.3
2.0 m/s (400 LFM)
0.5 m/s (100 LFM)
0.4
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
0.3
2.0 m/s (400 LFM)
0.2
0.2
0.1
0.1
0
0
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
www.murata-ps.com/support
MDC_BPM15.A02 Page 9 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
PERFORMANCE DATA, BPM15-120-Q12
Maximum Current Temperature Derating at Sea Level
(VIN = 18V, airflow is from pin 1 to pin 4)
Maximum Current Temperature Derating at Sea Level
(VIN = 24V, airflow is from pin 1 to pin 4)
0.7
0.7
0.6
0.6
0.5
0.5
0.33 m/s (65 LFM)
0.4
Output Current (A)
Output Current (A)
0.33 m/s (65 LFM)
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
0.3
2.0 m/s (400 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
0.3
2.0 m/s (400 LFM)
0.2
0.2
0.1
0.1
0
0.5 m/s (100 LFM)
0.4
0
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
30
Maximum Current Temperature Derating at Sea Level
(VIN = 30V, airflow is from pin 1 to pin 4)
35
40
45
70
75
80
85
80
85
Maximum Current Temperature Derating at Sea Level
(VIN = 36V, airflow is from pin 1 to pin 4)
0.7
0.7
0.6
0.6
0.5
0.5
0.4
Output Current (A)
0.33 m/s (65 LFM)
Output Current (A)
50
55
60
65
Ambient Temperature (ºC)
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
0.3
2.0 m/s (400 LFM)
0.33 m/s (65 LFM)
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
2.0 m/s (400 LFM)
0.4
0.3
0.2
0.2
0.1
0.1
0
0
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
www.murata-ps.com/support
MDC_BPM15.A02 Page 10 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
FUNCTIONAL SPECIFICATIONS, BPM15-150-Q12
ABSOLUTE MAXIMUM RATINGS
Input Voltage, Continuous
Input Voltage, Transient
Isolation Voltage
On/Off Remote Control
Output Power
Output Current
Storage Temperature Range
Conditions ➀
Minimum
0
100 mS max. duration
Input to output
Power on, referred to -Vin
Typical/Nominal
Units
1.485
Maximum
36
50
1600
15
15.15
0.05
0.5
A
0
Current-limited, no damage, short-circuit
protected
Vin = Zero (no power)
Vdc
Vdc
Vdc
Vdc
W
-55
125
˚C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those
listed in the Performance/Functional Specifications Table is not implied or recommended.
INPUT
Operating Voltage Range
Recommended External Fuse
Start-up Threshold
Undervoltage Shutdown (50% load)
Internal Filter Type
Input Current
Full Load Input Current
Low Line Input Current
Inrush Transient
Short Circuit Input Current
No Load Input Current
Shut-Down Input Current (Off, UV, OT)
Reflected (Back) Ripple Current ➁
Fast blow
Rising input voltage
Falling input voltage
9
24
8
7.7
8.5
8.2
C
Vin = nominal
Vin = minimum
Iout = minimum, unit=ON
Measured at input with specified filter
36
4
9
8.7
Vdc
A
Vdc
Vdc
74
1.96
0.05
0.05
100
1
10
0.77
2.03
0.1
130
2
A
mA
mA
mA, p-p
84.5
85.0
%
%
1600
A
A
A2-Sec.
GENERAL and SAFETY
Efficiency
Isolation
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Safety
Calculated MTBF
DYNAMIC CHARACTERISTICS
Fixed Switching Frequency
Startup Time
Startup Time
Dynamic Load Response
Dynamic Load Peak Deviation
FEATURES and OPTIONS
Remote On/Off Control ➂
“N” suffix
Negative Logic, ON state
Negative Logic, OFF state
Control Current
“P” suffix
Positive Logic, ON state
Positive Logic, OFF state
Control Current
Vin = 24V, full load
Vin = min., full load
82.5
83.0
Input to output
Certified to UL-60950-1, CSA-C22.2 No.
60950-1, IEC/60950-1, 2nd edition, with AM1
Per Telcordia SR332, issue 1, class 3, ground
fixed, Tambient = +25°C
10
1000
Approved
6.7
Power on to Vout regulated
Remote ON to Vout regulated
50-75-50% load step, settling time to within
1% of Vout
same as above
300
330
Vdc
MΩ
pF
Hours x 106
360
50
50
KHz
mS
mS
250
300
μSec
±100
±200
mV
ON = Ground pin
OFF = Pin open
Open collector/drain
-0.7
10
1
0.8
15
V
V
ON = Pin open
OFF = Ground pin
Open collector/drain
10
-0.7
1
15
0.8
mA
V
V
mA
www.murata-ps.com/support
MDC_BPM15.A02 Page 11 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
FUNCTIONAL SPECIFICATIONS, BPM15-150-Q12 (CONT.)
OUTPUT
Total Output Power
Voltage
Nominal Output Voltage
Setting Accuracy
Overvoltage Protection
Current
Output Current Range
Current Limit Inception
Short Circuit
Short Circuit Current
Short Circuit Duration (remove short
for recovery)
Short circuit protection method
Regulation
Line Regulation
Load Regulation
Ripple and Noise
Maximum Capacitive Loading
MECHANICAL
Outline Dimensions
(Please refer to outline drawing)
Weight
Through Hole Pin Diameter
Through Hole Pin Material
TH Pin Plating Metal and Thickness
ENVIRONMENTAL
Operating Ambient Temperature Range
Operating Case Temperature Range
Case Material
Storage Temperature
Thermal Protection/Shutdown
Electromagnetic Interference
Conducted, EN55022/CISPR22
RoHS rating
Notes
Conditions ➀ ➂
Minimum
1.485
Typical/Nominal
15.00
Maximum
15.15
Units
No trim
At 50% load, no trim
Via magnetic feedback
14.850
15.150
16.8
15.00
1
18
20.5
Vdc
% of Vnom
Vdc
98% of Vnom., after warmup
±0.05
±0.7
±0.5
±0.95
±0.5
±1.2
A
A
Hiccup technique, autorecovery within
±1.25% of Vout
0.3
A
W
Output shorted to ground, no damage
Continuous
Current limiting
Vin = min. to max., Vout = nom., Iout = nom.
Iout = min. to max., Vin = 24V
5 Hz- 20 MHz BW, Vin=24V
Low ESR, 0.02 ohms max
±0.05
±0.05
60
±0.25
±0.25
100
520
% of Vout
% of Vout
mV pk-pk
μF
WxLxH
Nickel subplate
Gold overplate
1 x 1 x 0.40
25.4 x 25.4 x 10.16
0.69
19.56
0.04
1.016
Copper alloy
50
5
Inches
mm
Ounces
Grams
Inches
mm
μ-inches
μ-inches
See derating
No derating
Tin plated steel with black powder coat
Vin = Zero (no power)
Measured in center
External filter is required
-40
-40
130
B
RoHS-6
85
91
125
140
°C
°C
➀ Unless otherwise noted, all specifications are at nominal input voltage, nominal output voltage and
full load. General conditions are +25˚ Celsius ambient temperature, near sea level altitude, natural
convection airflow. All models are tested and specified with external parallel 1 μF and 10 μF output
capacitors. The external input capacitor is 100 μF.
-55
120
°C
°C
Class
➁ Input (back) ripple current is tested and specified over 5 Hz to 20 MHz bandwidth. Input filtering is
Cbus = 220 μF, Cin = 33 μF and Lbus = 12 μH.
➂ The Remote On/Off Control is referred to -Vin.
www.murata-ps.com/support
MDC_BPM15.A02 Page 12 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
PERFORMANCE DATA, BPM15-150-Q12
87
85
83
81
79
77
75
73
71
69
67
65
63
61
59
57
55
0.05
Power Dissipation vs. Line Voltage and Load Current @ +25°C
3.0
2.5
Power Dissipation (Watts)
Efficiency (%)
Efficiency vs. Line Voltage and Load Current @ +25°C
Vin=9V
Vin=12V
Vin=24V
2.0
1.5
Vin=9V
Vin=12V
1.0
Vin=24V
Vin=36V
0.5
Vin=36V
0.0
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
Output Load Curre nt (Amps)
0.50
Load Curre nt (Amps)
Maximum Current Temperature Derating at Sea Level
(VIN = 12V, airflow is from pin 1 to pin 4)
0.5
0.5
0.4
0.4
0.3
0.33 m/s (65 LFM)
Output Current (A)
Output Current (A)
Maximum Current Temperature Derating at Sea Level
(VIN = 9V, airflow is from pin 1 to pin 4)
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
0.2
2.0 m/s (400 LFM)
0.33 m/s (65 LFM)
0.3
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
0.2
2.0 m/s (400 LFM)
0.1
0.1
0
0
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
www.murata-ps.com/support
MDC_BPM15.A02 Page 13 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
PERFORMANCE DATA, BPM15-150-Q12
Maximum Current Temperature Derating at Sea Level
(VIN = 24V, airflow is from pin 1 to pin 4)
0.5
0.5
0.4
0.4
0.33 m/s (65 LFM)
0.3
Output Current (A)
Output Current (A)
Maximum Current Temperature Derating at Sea Level
(VIN = 18V, airflow is from pin 1 to pin 4)
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
0.2
2.0 m/s (400 LFM)
0.1
0.33 m/s (65 LFM)
0.3
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
0.2
2.0 m/s (400 LFM)
0.1
0
0
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
30
0.5
0.5
0.4
0.4
0.3
0.33 m/s (65 LFM)
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
0.2
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
80
85
Maximum Current Temperature Derating at Sea Level
(VIN = 36V, airflow is from pin 1 to pin 4)
Output Current (A)
Output Current (A)
Maximum Current Temperature Derating at Sea Level
(VIN = 30V, airflow is from pin 1 to pin 4)
35
2.0 m/s (400 LFM)
0.3
0.33 m/s (65 LFM)
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
2.0 m/s (400 LFM)
0.2
0.1
0.1
0
0
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
www.murata-ps.com/support
MDC_BPM15.A02 Page 14 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
FUNCTIONAL SPECIFICATIONS, BPM15-050-Q48
ABSOLUTE MAXIMUM RATINGS
Input Voltage, Continuous
Input Voltage, Transient
Isolation Voltage
On/Off Remote Control
Output Power
Conditions ➀
100 mS max. duration
Input to output
Power on, referred to -Vin
Minimum
0
0
1.48
Typical/Nominal
Maximum
75
100
1600
15
15.23
Units
Vdc
Vdc
Vdc
Vdc
W
Current-limited, no damage, short-circuit
0.15
1.5
A
protected
Storage Temperature Range
Vin = Zero (no power)
-55
125
˚C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other
than those listed in the Performance/Functional Specifications Table is not implied or recommended.
INPUT
Operating Voltage Range
18
48
75
Vdc
Recommended External Fuse
Fast blow
2
A
Start-up Threshold
Rising input voltage
15.5
16.5
17.5
Vdc
Undervoltage Shutdown (50% load)
Falling input voltage
15
16
17
Vdc
Internal Filter Type
C
Input Current
Full Load Input Current
Vin = nominal
0.384
0.396
A
Low Line Input Current
Vin = minimum
1.019
1.057
A
Inrush Transient
0.05
A2-Sec.
Short Circuit Input Current
0.05
0.1
A
Minimum Load Input Current
Iout = minimum, unit = ON
50
100
mA
Shut-Down Input Current (Off, UV, OT)
1
2
mA
Measured at input with specified filter
50
mA, p-p
Reflected (Back) Ripple Current ➁
GENERAL and SAFETY
Vin = 48V, full load
80
81.4
%
Efficiency
Vin = min., full load
80
81.8
%
Isolation
Isolation Voltage
Input to output
1600
Vdc
Isolation Resistance
10
MΩ
Isolation Capacitance
1500
pF
Certified to UL-60950-1, CSA-C22.2 No.
Safety
Approved
60950-1, IEC/60950-1, 2nd edition, with AM1
Per Telcordia SR332, issue 1, class 3, ground
Calculated MTBF
5
Hours x 106
fixed, Tambient = +25°C
DYNAMIC CHARACTERISTICS
Fixed Switching Frequency
275
305
335
KHz
Startup Time
Power on to Vout regulated
50
mS
Startup Time
Remote ON to Vout regulated
50
mS
50-75-50% load step, settling time to within
Dynamic Load Response
100
200
μSec
1% of Vout
Dynamic Load Peak Deviation
same as above
±100
±150
mV
FEATURES and OPTIONS
Remote On/Off Control ➂
“N” suffix
Negative Logic, ON state
ON = Ground pin
-0.7
0.8
V
Negative Logic, OFF state
OFF = Pin open
10
15
V
Control Current
Open collector/drain
1
mA
“P” suffix
Positive Logic, ON state
ON = Pin open
10
15
V
Positive Logic, OFF state
OFF = Ground pin
-0.7
0.8
V
Control Current
Open collector/drain
1
mA
Output Current
www.murata-ps.com/support
MDC_BPM15.A02 Page 15 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
FUNCTIONAL SPECIFICATIONS, BPM15-050-Q48 (CONT.)
OUTPUT
Total Output Power
Voltage
Nominal Output Voltage
Setting Accuracy
Overvoltage Protection
Current
Output Current Range
Current Limit Inception
Short Circuit
Short Circuit Current
Short Circuit Duration (remove short
for recovery)
Short circuit protection method
Regulation
Line Regulation
Load Regulation
Ripple and Noise
Maximum Capacitive Loading
MECHANICAL
Outline Dimensions
(Please refer to outline drawing)
Weight
Conditions ➀ ➂
Minimum
1.48
Typical/Nominal
15
Maximum
15.23
Units
W
No trim
At 50% load, no trim
Via magnetic feedback
±4.925
±5.075
5.6
±5
±1.5
7
8
Vdc
% of Vnom
Vdc
±0.15
±1.7
±1.5
±2.7
±1.5
±3.0
A
A
0.3
A
±0.25
±0.25
100
1000
% of Vout
% of Vout
mV pk-pk
μF
98% of Vnom., after warmup
Hiccup technique, autorecovery within
±1.25% of Vout
Output shorted to ground, no damage
Continuous
Current limiting
Vin = min. to max., Vout = nom., Iout = nom.
Iout = min. to max., Vin = 48V
5 Hz - 20 MHz BW, Vin = 48V
Low ESR, 0.02 Ω max
60
1 x 1 x 0.40
25.4 x 25.4 x 10.16
0.69
19.56
0.04
1.016
Copper alloy
50
5
WxLxH
Through Hole Pin Diameter
Through Hole Pin Material
TH Pin Plating Metal and Thickness
ENVIRONMENTAL
Operating Ambient Temperature Range
Operating Case Temperature Range
Case Material
Storage Temperature
Thermal Protection/Shutdown
Electromagnetic Interference
Conducted, EN55022/CISPR22
RoHS rating
Notes
Nickel subplate
Gold overplate
See derating
No derating
Tin plated steel with black powder coat
Vin = Zero (no power)
Measured in center
External filter is required
➀ Unless otherwise noted, all specifications are at nominal input voltage, nominal output voltage and
full load. General conditions are +25˚ Celsius ambient temperature, near sea level altitude, natural
convection airflow. All models are tested and specified with external parallel 1 μF and 10 μF output
capacitors. The external input capacitor is 100 μF.
-40
-40
-55
120
130
B
RoHS-6
Inches
mm
Ounces
Grams
Inches
mm
μ-inches
μ-inches
85
93
°C
°C
125
140
°C
°C
Class
➁ Input (back) ripple current is tested and specified over 5 Hz to 20 MHz bandwidth. Input filtering is
Cbus = 220 μF, Cin = 33 μF and Lbus = 12 μH.
➂ The Remote On/Off Control is referred to -Vin.
www.murata-ps.com/support
MDC_BPM15.A02 Page 16 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
PERFORMANCE DATA, BPM15-050-Q48
Efficiency vs. Line Voltage and Load Current @ +25°C
Power Dissipation vs. Line Voltage and Load Current @ +25°C
84
4.0
82
3.5
80
Power Dissipation (Watts)
78
Efficiency (%)
76
VIN = 18V
VIN = 24V
VIN = 48V
VIN = 75V
74
72
70
68
3.0
2.5
VIN = 18V
VIN = 24V
VIN = 48V
VIN = 75V
2.0
1.5
1.0
66
0.5
64
0.0
0.1
62
0.3
0.5
0.6
60
0.7
0.9
1.0
1.2
1.3
1.5
Output Load Curre nt (Amps)
58
0.16
0.30
0.46
0.61
0.76
0.91
1.06
1.21
1.36
1.51
Load Curre nt (Amps)
Maximum Current Temperature Derating at Sea Level
(VIN = 18V, airflow is from pin 1 to pin 2)
Maximum Current Temperature Derating at Sea Level
(VIN = 24V, airflow is from pin 1 to pin 2)
2
0.5 m/s (100 LFM)
Output Current (Amps)
Output Current (Amps)
2
Natural convection
1
0
0.5 m/s (100 LFM)
Natural convection
1
0
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
www.murata-ps.com/support
MDC_BPM15.A02 Page 17 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
PERFORMANCE DATA, BPM15-050-Q48
Maximum Current Temperature Derating at Sea Level
(VIN = 36V, airflow is from pin 1 to pin 2)
Maximum Current Temperature Derating at Sea Level
(VIN = 48V, airflow is from pin 1 to pin 2)
2
0.5 m/s (100 LFM)
Output Current (Amps)
Output Current (Amps)
2
Natural convection
1
0
0.5 m/s (100 LFM)
Natural convection
1
0
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
30
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
80
85
Maximum Current Temperature Derating at Sea Level
(VIN = 75V, airflow is from pin 1 to pin 2)
Maximum Current Temperature Derating at Sea Level
(VIN = 60V, airflow is from pin 1 to pin 2)
2
2
0.5 m/s (100 LFM)
Output Current (Amps)
Output Current (Amps)
35
Natural convection
1
0
0.5 m/s (100 LFM)
Natural convection
1
0
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
www.murata-ps.com/support
MDC_BPM15.A02 Page 18 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
FUNCTIONAL SPECIFICATIONS, BPM15-120-Q48
ABSOLUTE MAXIMUM RATINGS
Input Voltage, Continuous
Input Voltage, Transient
Isolation Voltage
On/Off Remote Control
Output Power
Output Current
Storage Temperature Range
Conditions ➀
100 mS max. duration
Input to output
Power on, referred to -Vin
Current-limited, no damage, short-circuit
protected
Vin = Zero (no power)
Minimum
0
Fast blow
Rising input voltage
Falling input voltage
18
15.5
15
48
17
16.2
C
75
2
17.9
17.5
Vdc
A
Vdc
Vdc
Vin = nominal
Vin = minimum
Iout = minimum, unit=ON
Measured at input with specified filter
0.368
0.99
0.05
0.05
50
1
40
0.38
1.01
0.1
100
2
A
A
Vin = 48V, full load
Vin = min., full load
83
83
85
84.5
%
%
MΩ
pF
Maximum
75
100
1600
15
15.15
Units
1.48
Typical/Nominal
0.0625
0.625
A
0
Vdc
Vdc
Vdc
Vdc
W
-55
125
˚C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those
listed in the Performance/Functional Specifications Table is not implied or recommended.
INPUT
Operating Voltage Range
Recommended External Fuse
Start-up Threshold
Undervoltage Shutdown (50% load)
Internal Filter Type
Input Current
Full Load Input Current
Low Line Input Current
Inrush Transient
Short Circuit Input Current
No Load Input Current
Shut-Down Input Current (Off, UV, OT)
Reflected (Back) Ripple Current ➁
A2-Sec.
A
mA
mA
mA, p-p
GENERAL and SAFETY
Efficiency
Isolation
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Safety
Calculated MTBF
DYNAMIC CHARACTERISTICS
Fixed Switching Frequency
Startup Time
Startup Time
Dynamic Load Response
Dynamic Load Peak Deviation
FEATURES and OPTIONS
Remote On/Off Control ➂
“N” suffix
Negative Logic, ON state
Negative Logic, OFF state
Control Current
“P” suffix
Positive Logic, ON state
Positive Logic, OFF state
Control Current
Input to output
Certified to UL-60950-1, CSA-C22.2 No.
60950-1, IEC/60950-1, 2nd edition, with AM1
Per Telcordia SR332, issue 1, class 3, ground
fixed, Tambient = +25°C
10
1500
1600
Approved
5
Power on to Vout regulated
Remote ON to Vout regulated
50-75-50% load step, settling time to within
1% of Vout
same as above
290
320
Vdc
Hours x 106
350
50
60
KHz
mS
mS
150
250
μSec
±100
±200
mV
ON = Ground pin
OFF = Pin open
Open collector/drain
-0.7
10
1
0.8
15
V
V
ON = Pin open
OFF = Ground pin
Open collector/drain
10
-0.7
1
15
0.8
mA
V
V
mA
www.murata-ps.com/support
MDC_BPM15.A02 Page 19 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
FUNCTIONAL SPECIFICATIONS, BPM15-120-Q48 (CONT.)
OUTPUT
Total Output Power
Voltage
Nominal Output Voltage
Setting Accuracy
Overvoltage Protection
Current
Output Current Range
Current Limit Inception
Short Circuit
Short Circuit Current
Short Circuit Duration (remove short
for recovery)
Short circuit protection method
Regulation
Line Regulation
Load Regulation
Ripple and Noise
Maximum Capacitive Loading
MECHANICAL
Outline Dimensions
(Please refer to outline drawing)
Weight
Through Hole Pin Diameter
Through Hole Pin Material
TH Pin Plating Metal and Thickness
ENVIRONMENTAL
Operating Ambient Temperature Range
Operating Case Temperature Range
Case Material
Storage Temperature
Thermal Protection/Shutdown
Electromagnetic Interference
Conducted, EN55022/CISPR22
RoHS rating
Notes
Conditions ➀ ➂
Minimum
1.48
Typical/Nominal
15
Maximum
15.15
Units
No trim
At 50% load, no trim
Via magnetic feedback
±11.88
±12.12
14.9
±12
±1 16
18
Vdc
% of Vnom
Vdc
98% of Vnom., after warmup
±0.0625
±0.75
±0.625
±1.2
±0.625
±1.45
A
A
Hiccup technique, autorecovery within
±1.25% of Vout
0.3
A
W
Output shorted to ground, no damage
Continuous
Current limiting
Vin = min. to max., Vout = nom., Iout = nom.
Iout = min. to max., Vin = 48V
5 Hz- 20 MHz BW, Vin=48V
Low ESR, 0.02 ohms max
80
±0.25
±0.25
120
150
% of Vout
% of Vout
mV pk-pk
μF
WxLxH
Nickel subplate
Gold overplate
1 x 1 x 0.40
25.4 x 25.4 x 10.16
0.69
19.56
0.04
1.016
Copper alloy
50
5
Inches
mm
Ounces
Grams
Inches
mm
μ-inches
μ-inches
See derating
No derating
Tin plated steel with black powder coat
Vin = Zero (no power)
Measured in center
External filter is required
-40
-40
130
B
RoHS-6
85
108
125
140
°C
°C
➀ Unless otherwise noted, all specifications are at nominal input voltage, nominal output voltage and
full load. General conditions are +25˚ Celsius ambient temperature, near sea level altitude, natural
convection airflow. All models are tested and specified with external parallel 1 μF and 10 μF output
capacitors. The external input capacitor is 100 μF.
-55
120
°C
°C
Class
➁ Input (back) ripple current is tested and specified over 5 Hz to 20 MHz bandwidth. Input filtering is
Cbus = 220 μF, Cin = 33 μF and Lbus = 12 μH.
➂ The Remote On/Off Control is referred to -Vin.
www.murata-ps.com/support
MDC_BPM15.A02 Page 20 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
PERFORMANCE DATA, BPM15-120-Q48
Power Dissipation vs. Line Voltage and Load Current @ +25°C
3.5
86
84
82
80
78
76
74
72
70
68
66
64
62
60
58
3.0
Power Dissipation (Watts)
Efficiency (%)
Efficiency vs. Line Voltage and Load Current @ +25°C
VIN = 18V
VIN = 24V
VIN = 48V
VIN = 75V
2.5
2.0
1.5
VIN = 18V
VIN = 24V
VIN = 48V
VIN = 75V
1.0
0.5
0.0
0.06
0.06
0.13
0.19
0.25
0.31
0.37
0.44
0.50
0.56
0.13
0.19
0.25
0.31
0.37
0.44
Output Load Curre nt (Amps)
0.50
0.56
0.62
0.62
Load Curre nt (Amps)
Maximum Current Temperature Derating at Sea Level
(VIN = 18V, airflow is from pin 1 to pin 3)
Maximum Current Temperature Derating at Sea Level
(VIN = 24V, airflow is from pin 1 to pin 3)
650
650
600
Natural convection
0.5 m/s (100 LFM)
1.0 m/s (200 LFM)
1.5 m/s (300 LFM)
2.0 m/s (400 LFM)
550
Output Current (ma)
Output Current (ma)
600
500
450
Natural convection
0.5 m/s (100 LFM); 1.0 m/s (200 LFM); 1.5 m/s (300 LFM); 2.0 m/s (400 LFM)
550
500
450
400
400
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
30
Maximum Current Temperature Derating at Sea Level
(VIN = 48V, airflow is from pin 1 to pin 3)
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
80
85
Maximum Current Temperature Derating at Sea Level
(VIN = 75V, airflow is from pin 1 to pin 3)
650
650
600
600
Natural convection
0.5 m/s (100 LFM); 1.0 m/s (200 LFM); 1.5 m/s (300 LFM); 2.0 m/s (400 LFM)
Output Current (ma)
Output Current (ma)
35
550
500
450
Natural convection
0.5 m/s (100 LFM); 1.0 m/s (200 LFM); 1.5 m/s (300 LFM); 2.0 m/s (400 LFM)
550
500
450
400
400
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
www.murata-ps.com/support
MDC_BPM15.A02 Page 21 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
FUNCTIONAL SPECIFICATIONS, BPM15-150-Q48
ABSOLUTE MAXIMUM RATINGS
Input Voltage, Continuous
Input Voltage, Transient
Isolation Voltage
On/Off Remote Control
Output Power
Output Current
Storage Temperature Range
Conditions ➀
Minimum
0
100 mS max. duration
Input to output
Power on, referred to -Vin
Typical/Nominal
Units
1.485
Maximum
75
100
1600
15
15.15
0.05
0.5
A
0
Current-limited, no damage, short-circuit
protected
Vin = Zero (no power)
Vdc
Vdc
Vdc
Vdc
W
-55
125
˚C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those
listed in the Performance/Functional Specifications Table is not implied or recommended.
INPUT
Operating Voltage Range
Recommended External Fuse
Start-up Threshold
Undervoltage Shutdown (50% load)
Internal Filter Type
Input Current
Full Load Input Current
Low Line Input Current
Inrush Transient
Short Circuit Input Current
No Load Input Current
Shut-Down Input Current (Off, UV, OT)
Reflected (Back) Ripple Current ➁
Fast blow
Rising input voltage
Falling input voltage
18
48
16.25
15
16.8
16
C
Vin = nominal
Vin = minimum
Iout = minimum, unit=ON
Measured at input with specified filter
75
2
17.5
17
Vdc
A
Vdc
Vdc
0.36
0.97
0.05
0.05
50
1
35
0.38
1.01
0.1
100
2
A
mA
mA
mA, p-p
86.0
85.5
%
%
1600
A
A
A2-Sec.
GENERAL and SAFETY
Efficiency
Isolation
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Safety
Calculated MTBF
DYNAMIC CHARACTERISTICS
Fixed Switching Frequency
Startup Time
Startup Time
Dynamic Load Response
Dynamic Load Peak Deviation
FEATURES and OPTIONS
Remote On/Off Control ➂
“N” suffix
Negative Logic, ON state
Negative Logic, OFF state
Control Current
“P” suffix
Positive Logic, ON state
Positive Logic, OFF state
Control Current
Vin = 48V, full load
Vin = min., full load
83.0
83.0
Input to output
Certified to UL-60950-1, CSA-C22.2 No.
60950-1, IEC/60950-1, 2nd edition, with AM1
Per Telcordia SR332, issue 1, class 3, ground
fixed, Tambient = +25°C
10
700
Approved
5
Power on to Vout regulated
Remote ON to Vout regulated
50-75-50% load step, settling time to within
1% of Vout
same as above
290
320
Vdc
MΩ
pF
Hours x 106
350
50
60
KHz
mS
mS
250
300
μSec
±150
±250
mV
ON = Ground pin
OFF = Pin open
Open collector/drain
-0.7
10
1
0.8
15
V
V
ON = Pin open
OFF = Ground pin
Open collector/drain
10
-0.7
1
15
0.7
mA
V
V
mA
www.murata-ps.com/support
MDC_BPM15.A02 Page 22 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
FUNCTIONAL SPECIFICATIONS, BPM15-150-Q48 (CONT.)
OUTPUT
Total Output Power
Voltage
Nominal Output Voltage
Setting Accuracy
Overvoltage Protection
Current
Output Current Range
Current Limit Inception
Short Circuit
Short Circuit Current
Short Circuit Duration (remove short
for recovery)
Short circuit protection method
Regulation
Line Regulation
Load Regulation
Ripple and Noise
Maximum Capacitive Loading
MECHANICAL
Outline Dimensions
(Please refer to outline drawing)
Weight
Through Hole Pin Diameter
Through Hole Pin Material
TH Pin Plating Metal and Thickness
ENVIRONMENTAL
Operating Ambient Temperature Range
Operating Case Temperature Range
Case Material
Storage Temperature
Thermal Protection/Shutdown
Electromagnetic Interference
Conducted, EN55022/CISPR22
RoHS rating
Notes
Conditions ➀ ➂
Minimum
1.485
Typical/Nominal
15.00
Maximum
15.15
Units
No trim
At 50% load, no trim
Via magnetic feedback
14.850
15.150
16
15.00
1
19
22
Vdc
% of Vnom
Vdc
98% of Vnom., after warmup
±0.05
±0.6
±0.5
±1.1
±0.5
±1.5
A
A
Hiccup technique, autorecovery within
±1.25% of Vout
0.3
A
W
Output shorted to ground, no damage
Continuous
Current limiting
Vin = min. to max., Vout = nom., Iout = nom.
Iout = min. to max., Vin = 48V
5 Hz- 20 MHz BW, Vin=48V
Low ESR, 0.02 ohms max
±0.05
±0.075
80
±0.25
±0.275
120
150
% of Vout
% of Vout
mV pk-pk
μF
WxLxH
Nickel subplate
Gold overplate
1 x 1 x 0.40
25.4 x 25.4 x 10.16
0.69
19.56
0.04
1.016
Copper alloy
50
5
Inches
mm
Ounces
Grams
Inches
mm
μ-inches
μ-inches
See derating
No derating
Tin plated steel with black powder coat
Vin = Zero (no power)
Measured in center
External filter is required
-40
-40
130
B
RoHS-6
85
91
125
140
°C
°C
➀ Unless otherwise noted, all specifications are at nominal input voltage, nominal output voltage and
full load. General conditions are +25˚ Celsius ambient temperature, near sea level altitude, natural
convection airflow. All models are tested and specified with external parallel 1 μF and 10 μF output
capacitors. The external input capacitor is 100 μF.
-55
120
°C
°C
Class
➁ Input (back) ripple current is tested and specified over 5 Hz to 20 MHz bandwidth. Input filtering is
Cbus = 220 μF, Cin = 33 μF and Lbus = 12 μH.
➂ The Remote On/Off Control is referred to -Vin.
www.murata-ps.com/support
MDC_BPM15.A02 Page 23 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
PERFORMANCE DATA, BPM15-150-Q48
Efficiency vs. Line Voltage and Load Current @ +25°C
Power Dissipation vs. Line Voltage and Load Current @ +25°C
3.5
86
84
3.0
82
Power Dissipation (Watts)
80
Efficiency (%)
78
VIN = 18V
VIN = 24V
VIN = 48V
VIN = 75V
76
74
72
70
68
66
64
2.5
2.0
1.5
VIN = 18V
VIN = 24V
VIN = 48V
VIN = 75V
1.0
0.5
62
60
58
0.05
0.0
0.0
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.1
0.1
0.2
0.50
0.2
0.3
0.3
0.4
0.4
0.5
Output Load Curre nt (Amps)
Load Curre nt (Amps)
Maximum Current Temperature Derating at Sea Level
(VIN = 18V, 24V, 36V, 48V, 60V, 75V airflow is from pin 1 to pin 4)
0.6
0.5
Output Current (Amps)
.033 m/s (65LFM); 0.5 m/s (100 LFM); 1.0 m/s (200 LFM); 1.5 m/s (300 LFM); 2.0 m/s (400 LFM)
0.4
0.3
0.2
0.1
0
30
35
40
45
50
55
60
65
Ambient Temperature (ºC)
70
75
80
85
www.murata-ps.com/support
MDC_BPM15.A02 Page 24 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
MECHANICAL SPECIFICATIONS
SIDE VIEW
BOTTOM VIEW
0.40
(10.16)
0.800
(20.32)
6
1.00 (25.4)
1
5
0.500
(12.7)
2
0.300
(7.62)
3
4x
.080-.100
x .015-.025 HIGH
NON-METALLIC
STANDOFFS (DIMPLES)
4
CL
0.800 (20.32)
0.400
(10.16)
0.02 REF
(0.51)
0.40
(10.16)
CL
0.15 MIN
(3.81)
INSULATING
HEADER
END VIEW
PIN #1
ISOMETRIC VIEW
4
3
(FOR REF ONLY)
2
5
MATERIAL:
.040 PINS: COPPER ALLOY
1
PIN #1
INDICATOR
6
FINISH: (ALL PINS)
GOLD (5u"MIN) OVER NICKEL (50u" MIN)
TOP VIEW
Dimensions are in inches (mm shown for ref. only).
Third Angle Projection
Tolerances (unless otherwise specified):
.XX ± 0.02 (0.5)
.XXX ± 0.010 (0.25)
Angles ± 1˚
INPUT/OUTPUT CONNECTIONS
Pin
Function
1
+Vin
2
–Vin
3
On/Off Control*
4
–Vout
5
Common
6
+Vout
Standard pin length is shown. Please refer to the
Part Number Structure for alternate pin lengths.
*The Remote On/Off pin is optional.
It can be provided with positive
logic (P suffix) or negative logic (N
suffix). Please see the Part Number
Structure on page 2.
Components are shown for reference only.
www.murata-ps.com/support
MDC_BPM15.A02 Page 25 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
RECOMMENDED FOOTPRINT FOR THRU-HOLE CONVERTER (VIEW THROUGH CONVERTER)
TOP VIEW
0.800
(20.32)
0.400
(10.16)
4
3
0.100 (2.54)
1.02 MIN
COURTYARD
0.400
(10.16)
2
0.600
(15.24)
5
CL
CL
1
0.51 (12.95)
0.800
(20.32)
0.100
(2.54)
6
4x .100 'LANDING
ZONES' FOR NON-METALLIC
STANDOFFS
(KEEP FREE OF COMPS)
FINISHED HOLE SIZES
@ PINS 1 THRU 6
(PER IPC-D-275, LEVEL C)
.048-.062
0.51
(12.95)
CL
1.02 MIN (25.91)
COURTYARD
STANDARD PACKAGING
EACH STATIC DISSIPATIVE
PLASTIC TUBE HOLDS 16
CONVERTERS
21.88
(555.75)
REF
0.91 (23.11) REF
1.16 (29.46) REF
STANDARD PACKAGING FOR
STANDARD THRU-HOLE CONVERTER
16 UNITS PER TUBE
6 TUBES PER CARTON
MPQ=16 UNITS
MOQ=96 UNITS
www.murata-ps.com/support
MDC_BPM15.A02 Page 26 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
TECHNICAL NOTES
Input Fusing
Certain applications and/or safety agencies may require fuses at the inputs of
power conversion components. Fuses should also be used when there is the
possibility of sustained input voltage reversal which is not current-limited. For
greatest safety, we recommend a fast blow fuse installed in the ungrounded
input supply line.
The installer must observe all relevant safety standards and regulations. For
safety agency approvals, install the converter in compliance with the end-user
safety standard.
Input Under-Voltage Shutdown and Start-Up Threshold
Under normal start-up conditions, converters will not begin to regulate properly
until the rising input voltage exceeds and remains at the Start-Up Threshold
Voltage (see Specifications). Once operating, converters will not turn off until
the input voltage drops below the Under-Voltage Shutdown Limit. Subsequent
restart will not occur until the input voltage rises again above the Start-Up
Threshold. This built-in hysteresis prevents any unstable on/off operation at a
single input voltage.
Users should be aware however of input sources near the Under-Voltage
Shutdown whose voltage decays as input current is consumed (such as poorly
regulated capacitor inputs), the converter shuts off and then restarts as the
external capacitor recharges. Such situations could oscillate. To prevent this,
make sure the operating input voltage is well above the UV Shutdown voltage
AT ALL TIMES.
Start-Up Delay
Assuming that the output current is set at the rated maximum, the Vin to Vout
Start-Up Delay (see Specifications) is the time interval between the point when
the rising input voltage crosses the Start-Up Threshold and the fully loaded
regulated output voltage enters and remains within its specified regulation
band. Actual measured times will vary with input source impedance, external
input capacitance, input voltage slew rate and final value of the input voltage
as it appears at the converter.
These converters include a soft start circuit to moderate the duty cycle of the
PWM controller at power up, thereby limiting the input inrush current.
The On/Off Remote Control interval from inception to Vout regulated
assumes that the converter already has its input voltage stabilized above the
Start-Up Threshold before the On command. The interval is measured from the
On command until the output enters and remains within its specified accuracy
band. The specification assumes that the output is fully loaded at maximum
rated current.
Recommended Input Filtering
The user must assure that the input source has low AC impedance to provide
dynamic stability and that the input supply has little or no inductive content,
including long distributed wiring to a remote power supply. The converter will
operate with no additional external capacitance if these conditions are met.
For best performance, we recommend installing a low-ESR electrolytic
capacitor immediately adjacent to the converter’s input terminals. Initial suggested capacitor values are 10 to 22 μF, rated at twice the expected maxi-
mum input voltage. Make sure that the input terminals do not go below the
undervoltage shutdown voltage at all times. More input bulk capacitance may
be added in parallel (either electrolytic or tantalum) if needed.
Recommended Output Filtering
The converter will achieve its rated output ripple and noise with no additional
external capacitor. However, the user may install more external output capacitance to reduce the ripple even further or for improved dynamic response.
Again, use low-ESR ceramic (Murata GRM32 series) or polymer capacitors.
Initial values of 10 to 47 μF may be tried, either single or multiple capacitors in
parallel. Mount these close to the converter. Measure the output ripple under
your load conditions.
Use only as much capacitance as required to achieve your ripple and noise
objectives. Excessive capacitance can make step load recovery sluggish or
possibly introduce instability. Do not exceed the maximum rated output capacitance listed in the specifications.
Input Ripple Current and Output Noise
All models in this converter series are tested and specified for input reflected
ripple current and output noise using designated external input/output components, circuits and layout as shown in the figures below. The Cbus and Lbus
components simulate a typical DC voltage bus. Please note that the values of
Cin, Lbus and Cbus may vary according to the specific converter model.
TO
OSCILLOSCOPE
CURRENT
PROBE
+INPUT
VIN
+
–
+
–
LBUS
CBUS
CIN
-INPUT
CIN = 33μF, ESR < 700mΩ @ 100kHz
CBUS = 220μF, ESR < 100mΩ @ 100kHz
LBUS = 12μH
Figure 2: Measuring Input Ripple Current
+OUTPUT
C1
C2
SCOPE
RLOAD
COMMON
C1 = 1μF
C2 = 10μF
LOAD 2-3 INCHES (51-76mm) FROM MODULE
Figure 3: Measuring Output Ripple and Noise (PARD)
www.murata-ps.com/support
MDC_BPM15.A02 Page 27 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
Minimum Output Loading Requirements
All models regulate within specification and are stable under 10% minimum
load to full load conditions. Operation under no load might however slightly
increase output ripple and noise.
Thermal Shutdown
To protect against thermal overstress, these converters include thermal
shutdown circuitry. If environmental conditions cause the temperature of the
DC-DC’s to rise above the Operating Temperature Range up to the shutdown
temperature, an on-board electronic temperature sensor will power down
the unit. When the temperature decreases below the turn-on threshold, the
converter will automatically restart. There is a small amount of temperature
hysteresis to prevent rapid on/off cycling.
CAUTION: If you operate too close to the thermal limits, the converter may
shut down suddenly without warning. Be sure to thoroughly test your application to avoid unplanned thermal shutdown.
Temperature Derating Curves
The graphs in this data sheet illustrate typical operation under a variety of
conditions. The Derating curves show the maximum continuous ambient air
temperature and decreasing maximum output current which is acceptable
under increasing forced airflow measured in Linear Feet per Minute (“LFM”).
Note that these are AVERAGE measurements. The converter will accept brief
increases in current or reduced airflow as long as the average is not exceeded.
Note that the temperatures are of the ambient airflow, not the converter
itself which is obviously running at higher temperature than the outside air.
Also note that very low flow rates (below about 65 LFM) are similar to “natural
convection”, that is, not using fan-forced airflow.
Murata Power Solutions makes Characterization measurements in a closed
cycle wind tunnel with calibrated airflow. We use both thermocouples and an
infrared camera system to observe thermal performance.
CAUTION: If you exceed these Derating guidelines, the converter may have
an unplanned Over Temperature shut down. Also, these graphs are all collected
near Sea Level altitude. Be sure to reduce the derating for higher altitude.
Output Current Limiting
Current limiting inception is defined as the point at which full power falls
below the rated tolerance. See the Performance/Functional Specifications.
Note particularly that the output current may briefly rise above its rated value
in normal operation as long as the average output power is not exceeded. This
enhances reliability and continued operation of your application. If the output
current is too high, the converter will enter the short circuit condition.
Output Short Circuit Condition
When a converter is in current-limit mode, the output voltage will drop as the
output current demand increases. If the output voltage drops too low (approximately 98% of nominal output voltage for most models), the PWM controller
will shut down. Following a time-out period, the PWM will restart, causing
the output voltage to begin rising to its appropriate value. If the short-circuit
condition persists, another shutdown cycle will initiate. This rapid on/off cycling
is called “hiccup mode”. The hiccup cycling reduces the average output current, thereby preventing excessive internal temperatures and/or component
damage.
Remote On/Off Control
The remote On/Off Control can be specified with either logic logic type. Please
refer to the Connection Diagram on page 1 for On/Off connections.
Positive-logic models are enabled when the On/Off pin is left open or is
pulled high to +Vin with respect to –Vin. Therefore, the On/Off control can be
disconnected if the converter should always be on. Positive-logic devices are
disabled when the On/Off is grounded or brought to within a low voltage (see
Specifications) with respect to –Vin.
Negative-logic devices are on (enabled) when the On/Off pin is grounded or
brought to within a low voltage (see Specifications) with respect to –Vin. The
device is off (disabled) when the On/Off is pulled high (see Specifications) with
respect to –Vin.
Dynamic control of the On/Off function must sink the specified signal current
when brought low and withstand the specified voltage when brought high.
Be aware too that there is a finite time in milliseconds (see Specifications)
between the time of On/Off Control activation and stable, regulated output. This
time will vary slightly with output load type and current and input conditions.
Output Capacitive Load
These converters do not require external capacitance added to achieve rated
specifications. Users should only consider adding capacitance to reduce
switching noise and/or to handle spike current load steps. Install only enough
capacitance to achieve your noise and surge response objectives. Excess
external capacitance may cause regulation problems and possible oscillation
or instability.
The maximum rated output capacitance and ESR specification is given for a
capacitor installed immediately adjacent to the converter.
Floating Outputs
Since these are isolated DC-DC converters, their outputs are "floating." Any
BPM15 model may be configured to produce an output of 10V, 24V or 30V
(for ±5V, ±12V or ±15V models, respectively) by applying the load across
the +Output and –Output pins, with either output grounded. The Common
pin should be left open. Minimum 10% loading is recommended under these
conditions.
Soldering Guidelines
Murata Power Solutions recommends the specifications below when installing these
converters. These specifications vary depending on the solder type. Exceeding these
specifications may cause damage to the product. Your production environment may differ; therefore please thoroughly review these guidelines with your process engineers.
Wave Solder Operations for through-hole mounted products (THMT)
For Sn/Ag/Cu based solders:
Maximum Preheat Temperature
115° C.
Maximum Pot Temperature
270° C.
Maximum Solder Dwell Time
7 seconds
For Sn/Pb based solders:
Maximum Preheat Temperature
105° C.
Maximum Pot Temperature
250° C.
Maximum Solder Dwell Time
6 seconds
www.murata-ps.com/support
MDC_BPM15.A02 Page 28 of 29
BPM15 Series
Encapsulated Isolated Wide Input Bipolar 15-Watt DC-DC Converters
Emissions Performance
Murata Power Solutions measures its products for radio frequency emissions
against the EN 55022 and CISPR 22 standards. Passive resistance loads are
employed and the output is set to the maximum voltage. If you set up your
own emissions testing, make sure the output load is rated at continuous power
while doing the tests.
[3] Conducted Emissions Test Results
The recommended external input and output capacitors (if required) are
included. Please refer to the fundamental switching frequency. All of this
information is listed in the Product Specifications. An external discrete filter is
installed and the circuit diagram is shown below.
Test Card
Resistive Load
UUT
V+
Black
C16
C8
C8
L3
C8
L1
C8
C8
C8
C7
C3
Gnd
C4
Resistive Load
inside a metal
container
Vin+
C17
V-
Vout+
VinVout-
Figure 4. Conducted Emissions Test Circuit
Resistive Load
inside a metal
container
Graph 1. Conducted emissions performance with filter, CISPR 22, Class B, full load,
for BPM15-150-Q12P-C
[1] Conducted Emissions Parts List
Reference
L1
L3
C1, C2, C8
C7
C16, C17
C3, C4
Description
1mH, 6A
500μH,10A
2.2μfd
Electrolytic Capacitor 100μfd, 100V
.22μfd
Electrolytic Capacitor 33μfd, 100V
[2] Conducted Emissions Test Equipment Used

Rohde & Schwarz EMI Test Receiver (9KHz – 1000MHz) ESPC

Rohde & Schwarz Software ESPC-1 Ver. 2.20

OHMITE 25W – 1 Ohm resistor combinations

DC Source Programmable DC Power Supply Model 62012P-100-50
Graph 2. Conducted emissions performance without filter, CISPR 22, Class B, full
load, for BPM15-150-Q12P-C
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2016 Murata Power Solutions, Inc.
www.murata-ps.com/support