is1009rh neutron report

Neutron testing of the IS1009RH voltage reference
Nick van Vonno
Intersil Corporation
13 June 2013
Revision 0
Table of Contents
1. Introduction
2. Part Description
3. Test Description
3.1 Irradiation facility
3.2 Characterization equipment
3.3 Experimental Matrix
4 Results
4.1 Test results
4.2 Variables data
5 Discussion and conclusion
6 Appendices
7 Document revision history
1. Introduction
This report summarizes results of 1 MeV equivalent neutron testing of the IS1009RH voltage
reference. The test was conducted in order to determine the sensitivity of the part to the
displacement damage caused by the neutron environment. Neutron fluences ranged from 2 x 1012
n/cm2 to 1 x 1014 n/cm2 in an approximately logarithmic sequence. This project was carried out in
collaboration with Honeywell Aerospace (Clearwater, FL), and their support is gratefully
acknowledged.
2: Part Description
The IS-1009RH is a 2.5V radiation hardened shunt reference designed to provide a stable
2.5V reference over a wide current range. The device is designed to maintain stability over the full
military temperature range and over time. The 0.2% reference tolerance is achieved by on-chip
trimming. An adjustment terminal is provided to allow for the calibration of system errors. The use of
this terminal to adjust the reference voltage does not affect the part’s temperature coefficient.
Constructed using the Intersil dielectrically isolated EBHF process, this device is immune to single
event latchup (SEL) and has been specifically designed to provide highly reliable performance in
harsh radiation environments. Specifications for Rad Hard QML devices are controlled by the
Defense Logistics Agency (DLA) in Columbus, OH. Detailed electrical specifications for this device
1
may be found in SMD 5962-00523. The IS1009RH is offered in a hermetic TO-206AB ‘can’ or in a
SMD.5 hermetic surface mount package. The device operates over the standard military
temperature range of -55°C to +125°C.
The IS1009RH is implemented in the EBHF process, which is a complementary bipolar flow
using dielectrically isolated (DI) substrates. The process is used for a range of commercial and
hardened operational amplifiers and voltage references. The DI technology enables vertical NPN
and PNP devices, unlike the vertical NPN/lateral PNP combination used in commercial junction
isolated processes. The vertical PNP device improves AC performance and total dose hardness,
while the DI substrate eliminates latchup by either electrical or SEE conditions. The process is in
volume production under MIL-PRF-38535 certification in the Palm Bay, Florida Intersil wafer
fabrication facility.
3: Test Description
3.1 Irradiation Facilities
Neutron irradiation was performed by the Honeywell team at the Fast Burst Reactor facility at
White Sands Missile Range (White Sands, NM), which provides a controlled 1MeV equivalent
neutron flux. Parts were tested in an unbiased configuration with all leads open. As neutron
irradiation activates many of the elements found in a packaged integrated circuit, the parts exposed
at the higher neutron levels required (as expected) significant ‘cooldown time’ before being shipped
back to Palm Bay for electrical testing.
3.2 Characterization equipment and procedures
Electrical testing was performed before and after irradiation using the Intersil production
automated test equipment (ATE). All electrical testing was performed at room temperature.
3.3 Experimental matrix
Testing proceeded in general accordance with the guidelines of MIL-STD-883 Test Method
1017. The experimental matrix consisted of five samples irradiated at 2 x 1012 n/cm2, five samples
irradiated at 1 x 1013 n/cm2, five samples irradiated at 3 x 1013 n/cm2 and five samples irradiated at 1
x 1014 n/cm2. Two control units were used.
4: Results
4.1 Test results
Neutron testing of the IS1009RH is complete and the results are reported in the balance of
this report. It should be realized when reviewing the data that each neutron irradiation was made on
a different 5-unit sample; this is not total dose testing, where the damage is cumulative.
4.2 Variables data
The plots in Figs. 1 through 6 show data plots for key parameters before and after irradiation
to each level. The plots show the average, minimum and maximum of each parameter as a function
of neutron irradiation.
2
Reference voltage, 1mA, V
2.57
2.56
Median
Min
2.55
Max
Spec min
2.54
Spec max
2.53
2.52
2.51
2.50
2.49
2.48
Pre-rad
1.00E+12
1.00E+13
1.00E+14
Neutron dose, n/cm2
Fig. 1: IS1009RH reference voltage as a function of neutron irradiation, showing the mean, minimum and
12
2
13
2
maximum of the populations at each level. Sample size was 5 for each cell (2 x 10 n/cm , 1 x 10 n/cm , 3 x
13
2
14
2
10 n/cm and 1 x 10 n/cm ), with two control units. The post-irradiation SMD limits are 2.490V to 2.515V.
2.55
Median
Zener voltage, 400µA, V
2.54
2.53
Min
Max
2.52
2.51
2.50
2.49
Pre-rad
1.00E+12
1.00E+13
1.00E+14
Neutron dose, n/cm2
Fig. 2: IS1009RH Zener voltage at 400µA as a function of neutron irradiation, showing the mean, minimum and
12
2
13
2
maximum of the populations at each level. Sample size was 5 for each cell (2 x 10 n/cm , 1 x 10 n/cm , 3 x
13
2
14
2
10 n/cm and 1 x 10 n/cm ), with two control units. This is an informational parameter used to develop the
dVZ/dI parameter (Fig. 4) and is not specified in the SMD.
3
Zener voltage, 10mA, V
2.66
2.64
Median
2.62
Min
2.60
Max
2.58
2.56
2.54
2.52
2.50
2.48
Pre-rad
1.00E+12
1.00E+13
Neutron dose,
1.00E+14
n/cm2
Fig. 3: IS1009RH Zener voltage at 10mA as a function of neutron irradiation, showing the mean, minimum and
12
2
13
2
maximum of the populations at each level. Sample size was 5 for each cell (2 x 10 n/cm , 1 x 10 n/cm , 3 x
13
2
14
2
10 n/cm and 1 x 10 n/cm ), with two control units. This is an informational parameter used to develop the
dVZ/dI parameter (Fig. 4) and is not specified in the SMD.
120.0
100.0
dVz/dI, mV
80.0
Median
Min
Max
Spec min
Spec max
60.0
40.0
20.0
0.0
-20.0
-40.0
Pre-rad
1.00E+12
1.00E+13
Neutron dose,
1.00E+14
n/cm2
Fig. 4: IS1009RH change in Zener voltage over change in Zener current, current range 400µA to 10mA, as a
function of neutron irradiation, showing the mean, minimum and maximum of the populations at each level.
12
2
13
2
13
2
14
2
Sample size was 5 for each cell (2 x 10 n/cm , 1 x 10 n/cm , 3 x 10 n/cm and 1 x 10 n/cm ), with two
control units. The post-irradiation SMD limits are -15.0mV to 15.0mV.
4
Control pin HIGH voltage, V
3.60
3.40
3.20
Median
Min
Max
Spec min
Spec max
3.00
2.80
2.60
2.40
Pre-rad
1.00E+12
1.00E+13
Neutron dose,
1.00E+14
n/cm2
Fig. 5: IS1009RH control pin HIGH voltage as a function of neutron irradiation, showing the mean, minimum and
12
2
13
2
maximum of the populations at each level. Sample size was 5 for each cell (2 x 10 n/cm , 1 x 10 n/cm , 3 x
13
2
14
2
10 n/cm and 1 x 10 n/cm ), with two control units. This is an informational parameter and is not specified in
the SMD.
Control pin LOW voltage, V
2.80
2.60
2.40
2.20
2.00
1.80
1.60
1.40
Pre-rad
1.00E+12
Median
Min
Max
Spec min
Spec max
1.00E+13
Neutron dose,
1.00E+14
n/cm2
Fig. 6: IS1009RH control pin LOW voltage as a function of neutron irradiation, showing the mean, minimum and
12
2
13
2
maximum of the populations at each level. Sample size was 5 for each cell (2 x 10 n/cm , 1 x 10 n/cm , 3 x
13
2
14
2
10 n/cm and 1 x 10 n/cm ), with two control units. This is an informational parameter and is not specified in
the SMD.
5
5: Discussion and conclusion
This document reports the results of neutron testing of the IS1009RH shunt voltage reference.
Samples were irradiated to levels of 2 x 1012 n/cm2, 1 x 1013 n/cm2, 3 x 1013 n/cm2 and 1 x 1014
n/cm2 with a sample size of five parts per cell. It should again be realized when reviewing the data
that each neutron irradiation was made on a different 5-unit sample; this is not total dose testing,
where the damage is cumulative. ATE characterization testing was performed before and after the
irradiations, and two control units were used to insure repeatable data. Variables data for monitored
parameters is presented in Figs. 1 through 6. We will discuss the results on a parameter by
parameter basis. The 2 x 1012 n/cm2 level is of some interest in the context of recent developments
in the JEDEC community, where the discrete component vendor community have signed up for
characterization testing (but not for acceptance testing) at this level.
The IS1009RH is not formally designed for neutron hardness. The part is built in a DI
complementary bipolar process. These bipolar transistors are minority carrier devices, obviously,
and may be expected to be sensitive to displacement damage (DD) at the higher levels. This
expectation turned out to be correct. We will discuss the results on a parameter by parameter basis
and then draw some conclusions. This is a simple device and only six parameters are monitored,
two of which are actually specified in the SMD.
The reference voltage is the key parameter for this part. It showed good stability after 2 x 1012
n/cm2, 1 x 1013 n/cm2 and 3 x 1013 n/cm2 irradiation but was out of specification after 1 x 1014 n/cm2
irradiation. The range was also greatly increased at this highest level.
The Zener voltage at both 400µA and 10mA showed good stability after 2 x 1012 n/cm2, 1 x 1013
n/cm2 and 3 x 1013 n/cm2 irradiation but increased significantly after 1 x 1014 n/cm2 irradiation. The
range was also greatly increased at this highest level. These are informational parameters and are
not specified in the SMD.
The Zener voltage change over a range of Zener currents (measured from 400µA to 10mA)
showed good stability after 2 x 1012 n/cm2, 1 x 1013 n/cm2 and 3 x 1013 n/cm2 irradiation but was out
of specification after 1 x 1014 n/cm2 irradiation. The range was also greatly increased at this highest
level. This is the second parameter specified in the SMD.
The Adjust pin HIGH and LOW voltages showed good stability after 2 x 1012 n/cm2, 1 x 1013
n/cm2 and 3 x 1013 n/cm2 irradiation. The LOW voltage increased significantly after 1 x 1014 n/cm2
irradiation. These are informational parameters and are not specified in the SMD.
We conclude that the IS1009RH is capable of post 3 x 1013 n/cm2 operation within the SMD
post-total dose parameters. The part is not capable of post 1 x 1014 n/cm2 operation as several
parameters changed drastically; the part did, however, remain functional.
6
6: Appendices
6.1: Reported parameters.
Fig.
1
2
3
4
5
6
Parameter
Limit, low
Limit,
high
Units
Notes
2.490
-15.0
-
2.515
15.0
-
V
mV
-
-
Reference voltage
Zener voltage, 400µA
Zener voltage, 10mA
dVZ/dIZ
Control pin HIGH voltage
Control pin LOW voltage
7: Document revision history
Revision
0
Date
13 June 2013
Pages
All
Comments
Original issue
7