G1G170AB3151 1593518

EC centrifugal fan
G1G170-AB31-51
backward curved, single inlet
with housing (flange), Gas blower for gas-condensing heating
ebm-papst Landshut GmbH
Hofmark-Aich-Str. 25 · D-84030 Landshut
Phone+49 871 707-0
Fax+49 871 707-465
[email protected]
www.ebmpapst.com
Nominal data
Type
G1G170-AB31-51
Motor
M1G074-CF
Phase
1~
Nominal voltage
VAC
230
Frequency
Hz
50/60
Type of data definition
ml
Speed
min-1
6530
Power input
W
410
Current draw
A
1.8
Min. back pressure
Pa
2000
Min. ambient temperature
°C
- 25
Max. ambient temperature
°C
+55
Min. temp. of flow medium
°C
-25
Max. temp. of flow medium
°C
+80
ml = max. load · me = max. efficiency · rfa = running at free air · cs = customer specs · cu = customer unit
Subject to alterations
Item no.: 50129-5-9980 · Revision: 66688 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 1 of 5
ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0·Fax +49 871 707-465 · [email protected] · www.ebmpapst.com
EC centrifugal fan
G1G170-AB31-51
backward curved, single inlet
with housing (flange), Gas blower for gas-condensing heating
Technical features
Mass
4.7 kg
Size
170 mm
Surface of rotor
Coated in black
Material of protective cover
Polyflam RPP 374-ND CS1 (UL 97-V0)
Material of impeller
Aluminium sheet
Housing material
Die-cast aluminium
Direction of rotation
Clockwise, seen on rotor
Type of protection
IP 20
Insulation class
"B"
Max. permissible ambient
motor temp. (transp./ storage)
+80 °C
Min. permissible ambient
motor temp. (transp./storage)
-40 °C
Mounting position
Any
Cooling bore / aperture
Rotor-side
Motor bearing
Ball bearing
Technical features
- Tach output
- Motor current limit
- PFC, active
- PWM control input
- Over-temperature protected motor
EMC interference immunity
Acc. to EN 61000-6-2
EMC interference emission
Acc. to EN 61000-6-4 (industrial environment)
EMC harmonics
Acc. to EN 61000-3-2/3
Leakage current
<= 3.5 mA
Electrical leads
With plug
Motor protection
Thermal overload protector (TOP) wired internally
Product conforming to
standard
CE
Approval
CSA C22.2 Nr.113; UL 507
Item no.: 50129-5-9980 · Revision: 66688 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 2 of 5
ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0·Fax +49 871 707-465 · [email protected] · www.ebmpapst.com
G1G170-AB31-51
EC centrifugal fan
backward curved, single inlet
with housing (flange), Gas blower for gas-condensing heating
Product drawing
1
Housing side parts sealed with NBR round cord (pentane-resistant)
2
3-pole strip; mating connector (not included in delivery): tyco No. 350 766-1; female connector: No. 926 884-1
2.1
L
2.2
N
2.3
PE
3
5-pole strip; mating connector (not included in delivery) Molex No. 39-01-4050, female connector Molex No. 39-00-0059
3.1
(+)
3.2
Speed monitoring
3.3
Not assigned
3.4
PWM input
3.5
(-)
4
Bleeder connection for pressure relief possible
Z
View Z
Item no.: 50129-5-9980 · Revision: 66688 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 3 of 5
ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0·Fax +49 871 707-465 · [email protected] · www.ebmpapst.com
EC centrifugal fan
G1G170-AB31-51
backward curved, single inlet
with housing (flange), Gas blower for gas-condensing heating
Connection screen
No.
Pin
Signal
Function / assignment
ST1
1, 2, 3
L, N, PE
Power supply 230 VAC, 50-60 Hz, neutral conductor, protective earth
ST2
1
UB
External voltage 24-45 VDC
ST2
2
DUE
Speed monitoring output connection, monitoring circuit output, 3 pulses per revolution, current source 1 mA
ST2
3
N.C
Not assigned
ST2
4
PWM
PWM - 2 - 6 kHz control input, PWM on n = 100%, PWM low n = 0%
ST2
5
GND
GND - Connection for control interface
Item no.: 50129-5-9980 · Revision: 66688 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 4 of 5
ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0·Fax +49 871 707-465 · [email protected] · www.ebmpapst.com
EC centrifugal fan
G1G170-AB31-51
backward curved, single inlet
with housing (flange), Gas blower for gas-condensing heating
Charts: Air flow 50 Hz
Druck psf [Pa]für Rho=1,2kg/m^3
qv[cfm]
4.000
0
50
100
150
200
250
300
350
400
450
16
15,5
3.800
15
14,5
3.600
14
3.400
Measurement: LU-56469
13,5
4
3.200
13
12,5
3.000
12
3
2.800
11,5
11
10,5
2.600
10
2
9,5
9
sf [Pa]
p
2.200
8,5
1
2.000
8
7,5
1.800
7
p sf _E[IN H2O]
2.400
Air performance measured as per ISO 5801
Installation category A. For detailed
information on the measuring set-up, please
contact ebm-papst. Suction-side noise
levels: LwA measured as per ISO 13347 /
LpA measured with 1m distance to fan axis.
The values given are valid under the
measuring conditions mentioned above and
may vary according to the actual installation
situation. With any deviation from the
standard set-up, the specific values have to
be checked and reviewed with the unit
installed.
6,5
1.600
6
1.400
5,5
5
1.200
4,5
1.000
4
3,5
800
3
2,5
600
2
400
1,5
1
0
]
[Pa
spf
200
0
50
100
150
200
250
300
350
400
qv[m^3/h]
450
500
550
600
650
700
0,5
750
0
Measured values
U
f
n
Pe
I
qv
psf
V
Hz
min-1
W
A
m3/h
Pa
1
230
50
6530
410
1.80
380
2000
2
230
50
6665
400
1.75
330
2400
3
230
50
6915
370
1.62
250
2800
4
230
50
7250
326
1.44
150
3200
Item no.: 50129-5-9980 · Revision: 66688 · Print-out 07/11/2011 · K. Boruzki (VI-I) · Page 5 of 5
ebm-papst Landshut GmbH · Hofmark-Aich-Str. 25 · D-84030 Landshut · Phone +49 871 707-0·Fax +49 871 707-465 · [email protected] · www.ebmpapst.com