CHPFL 0150 BNC

M
ICROWAVE
A Division of Crystek Corporation
In/Out
• 7th Order Chebyshev Response
• 50Ω BNC Connectors
th
Schematic
In/Out
2.590
(65.79)
1.480
(37.59)
• Test Equipment
• Lab Use
0.550
(13.97)
BNC
Male
• +36dBm (4 Watts)
• Operating Temperature: -40°C to 85°C
• Storage Temperature: -45°C to 90°C
BNC
Female
Crystek’s new line of BNC High Pass Filters are designed in a rugged BNC
housing. This filter line has excellent out-of-band rejection.
Designed for Test Equipment and General Lab Use.
Rev A
Page 1 of 3
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com
M
ICROWAVE
A Division of Crystek Corporation
Insertion Loss
0
Loss (dB)
20
40
60
80
100
120
0
50
100
150
200
250
300
350
400
450
500
350
400
450
500
Frequency (MHz)
Return Loss
Loss (dB)
0
10
20
30
40
0
50
100
150
200
250
300
Frequency (MHz)
Rev A
Page 2 of 3
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com
M
ICROWAVE
A Division of Crystek Corporation
FREQ
(MHz)
INSERTION LOSS
(dB)
RETURN LOSS
(dB)
0.300
74.83
0.03
2.799
105.03
0.00
5.297
107.78
0.00
7.796
99.38
0.00
10.294
101.00
0.00
12.793
102.79
0.00
15.291
103.67
0.01
17.790
108.08
0.01
20.288
101.69
0.02
22.787
108.41
0.02
25.285
105.95
0.03
27.784
106.81
0.03
30.282
106.13
0.04
32.781
103.44
0.05
35.279
102.32
0.06
40.276
94.46
0.08
42.775
89.65
0.09
47.772
83.24
0.11
50.270
80.27
0.13
52.769
76.58
0.14
55.267
73.42
0.15
60.264
67.96
0.18
65.261
62.54
0.22
70.258
57.49
0.25
72.757
55.06
0.27
95.243
35.25
0.50
130.222
7.80
2.50
147.712
1.60
12.12
170.198
0.81
20.67
200.180
0.61
18.18
225.165
0.49
19.23
250.150
0.39
23.78
277.634
0.33
30.33
300.120
0.31
25.59
325.105
0.31
21.68
375.075
0.33
18.34
455.027
0.36
15.97
500.000
0.41
14.94
Product Control:
Crystek Part Number:
CHPFL-0150-BNC
Release Date:
09-Jul-2015
Rev A
Revision Level:
A
Responsible:
K. Piotrowicz
Page 3 of 3
CRYSTEK
CORPORATION
12730 Commonwealth Drive • Fort Myers, Florida 33913
Phone: 239-561-3311 • 800-237-3061
Fax: 239-561-1025 • www.crystek.com