MATERIAL:
HOUSING MATERIAL: PPS
COLOR: BEIGE
ACTUATOR MATERIAL: PPS
COLOR: BLACK
CONTACT MATERIAL: PHOSPOR BRONZE
CONTACT PLATING: 100µ’’ TIN OVER 50µ’’ NI
QUALITY CLASS: 25 MATING CYCLES*
8
APPLICABLE FFC LAYOUT
(THICKNESS: 0.29 to 0.34)
RECOMMENDED PCB LAYOUT - COMPONENT VIEW
A
ENVIRONNEMENTAL:
OPERATING TEMPERATURE: -25°C UP TO 85°C
FLAMABILITY RATING: UL94-V0
COMPLIANCE: LEAD FREE AND ROHS
ELECTRICAL:
CURRENT RATING: 1A
WORKING VOLTAGE: 125V
INSULATION RESISTANCE: >100MOHM
DIELECTRIC WITHSTANDING VOLT.: 500VAC/MN
CONTACT RESISTANCE: 20mOHM MAX
STANDARD
CERTIFIED: E323964 / MODEL NUMBER 686
FOLLOWED BY 1, FOLLOWED BY 03 THRU 30, FOLLOWED
BY 141 OR 144, FOLLOWED BY NUMERIC DIGITS
B
SOLDERING:
REFLOW PROCESS ONLY
DIMENSION:
A =B + 8.00
B =1.00 x (NB PINS - 1)
C =B + 2.1
D =B + 6.00
C
RoHS Compliant
*NOTE: theoretical value related to the Tin plating; however, due to the sensitive actuator, we recommend not to make more than 1 or 2 cycles in order to maintain acceptable mechanical & electrical conditions
N
05-JUN-15
TPK REVIEW
AK
M
13-DEC-13
TPK UPDATE
QL
L
10-APR-13
ACTUATOR
AR
K
23-JAN-13
UNIT µ => µ’’
QL
J
18-SEP-12
MC NOTE
GG
I
28-JUN-12
COLOR
GG
H
26-JUN-12
DIM
REV
DATE
FILE
PROJECTION:
GENERAL TOLERANCE
.X = +/- 0.2
.XX = +/- 0.15
SCALE:
DESCRIPTION: 1.0MM ZIF FPC HORIZONTAL BOTTOM CONTACT TYPE TAPE & REEL PACKAGING
GG
SHEET: 1/2
WERI PART NO: 686 1xx 144 22
BY
DRAW: PEARL
APPROVAL: GMo
UNIT: MM
SIZE
A4
D
1
2
3
4
5
A
B
C
RoHS Compliant
PROJECTION:
G
F
GENERAL TOLERANCE
.X = +/- 0.2
.XX = +/- 0.15
E
D
C
APPROVAL: GMo
B
A
REV
DATE
FILE
BY
SCALE:
DESCRIPTION: 1.0MM ZIF FPC HORIZONTAL BOTTOM CONTACT TYPE TAPE & REEL PACKAGING
SHEET: 2/2
WERI PART NO: 686 1xx 144 22
UNIT: MM
DRAW: AK
SIZE
A4
D
1
1
2
2
Pull the actuator upwards in the open position
Insert the FFC cable vertically until the conductor
almost disappears
A
B
1
2
Press actuator in the middle to make there is no
gap and the actuator is locked
Press both ends of the actuator
A
Pull the actuator as horizontally as possible
by a proper force
Do not pull the actuator too far otherwise the stop
limit (hook on actuator) may be broken
B
Do not keep FFC inclined when insertion
Don’t keep conductor toward actuator