Derating Download

For Instructions, please see:
http://www.erni.com/DB/derating/DERATING-Instructions.pdf
DERATING CURVE (Current carrying capacity acc. IEC 60512-5-2 Test 5b)
Current (A]
IEC 60603-2 connector H11 with 11 contacts (Faston termination)
25
20
15
10
Base curve [A]
5
Derating curve [A]
Temperature [°C]
0
0
Base curve [A]
Derating curve [A]
© ERNI Elektroapparate GmbH 2006
10
20
22,5
18
30
21,6
17,28
40
20,5
16,4
50
19,1
15,28
60
17,6
14,08
70
16
12,8
80
14,3
11,44
90
12,5
10
100
10,5
8,4
All rights reserved. Only for information. Subject to modification without prior notice.
110
8
6,4
120
5
4
130