Varistor Products
High Energy Industrial
BA/BB Varistor Series
®
The BA and BB Series transient surge suppressors are heavy-duty
industrial metal-oxide varistors (MOVs) designed to provide surge
protection for motor controls and power supplies used in oil-drilling, mining,
transportation equipment and other heavy industrial AC line applications.
These UL-recognized varistors have similar package construction but
differ in size and ratings.The BA models are rated from 130 to
880VM(AC) . The BB models from 1100 to 2800VM(AC) .
Both the BA and BB Series feature improved creep and strike capability
to minimize breakdown along the package surface, a package design
that provides complete electrical isolation of the disc subassembly, and
rigid terminals to insure secure wire contacts.
See BA/BB Series Device Ratings and Specifications table for part
number and brand information.
Features
BB SERIES
• High Energy Absorption Capability WTM
BA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3200J
BB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10,000J
• Wide Operating Voltage Range VM(AC)RMS
BA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130V to 880V
BB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1100V to 2800V
• Rigid Terminals for Secure Wire Contact
• Case Design Provides Complete Electrical Isolation of Disc
Subassembly
• Littelfuse Largest Packaged Disc . . . . . . . . . . . . . . .60mm Diameter
• No Derating Up to 85oC Ambient
AGENCY APPROVALS: Recognized under the components program of
Underwriters Laboratories (BA Series only).
AGENCY FILE NUMBERS: UL E75961.
72
BA SERIES
w w w. l i t t e l f u s e . c o m
Next
Previous
Varistor Products
High Energy Industrial
BA/BB Varistor Series
For ratings of individual members of a series, see Device Ratings and Specifications chart
BA SERIES
BB SERIES
Continuous:
Steady State Applied Voltage:
AC Voltage Range (VM(AC)RMS). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 to 880
1100 to 2800
DC Voltage Range (VM(DC)). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 to 1150
1400 to 3500
Transient:
Peak Pulse Current (ITM)
For 8/20µs Current Wave (See Figure 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50,000 to 70,000
70,000
Single Pulse Energy Range
For 2ms Current Squarewave (WTM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450 to 3200
3800 to 10,000
Operating Ambient Temperature Range (TA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55 to 85
-55 to 85
Storage Temperature Range (TSTG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55 to 125
-55 to 125
Temperature Coefficient (αV) of Clamping Voltage (VC) at Specified
Test Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <0.01
<0.01
Hi-Pot Encapsulation (Isolation Voltage Capability) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5000
5000
(Dielectric must withstand indicated DC voltage for one minute per
MIL-STD 202, Method 301)
Insulation Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000
1000
UNITS
V
V
A
J
C
0
C
0
%/0C
V
MΩ
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the device
at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Device Ratings and Specifications
MAXIMUM RATINGS (85 oC)
CONTINUOUS
PART NUMBER
AND DEVICE
BRANDING
SPECIFICATIONS (25 oC)
TRANSIENT
VRMS
VDC
ENERGY
(2ms)
VM(AC)
VM(DC)
WTM
PEAK
CURRENT
(8/20µs)
ITM
VARISTOR VOLTAGE
AT 1mA DC
TEST CURRENT
MIN
VN(DC)
MAX
MAX CLAMPING
VOLT V C AT 200A
CURRENT (8/20µs)
TYPICAL
CAPACITANCE
VC
f = 1MHz
(V)
(V)
(J)
(A)
(V)
(V)
(V)
(V)
(pF)
V131BA60
130
175
450
50000
184
200
228
340
20000
V151BA60
150
200
530
50000
212
240
268
400
16000
V251BA60
250
330
880
50000
354
390
429
620
10000
V271BA60
275
369
950
50000
389
430
473
680
9000
V321BA60
320
420
1100
50000
462
510
561
760
7500
V421BA60
420
560
1500
70000
610
680
748
1060
6000
V481BA60
480
640
1600
70000
670
750
825
1160
5500
V511BA60
510
675
1800
70000
735
820
910
1300
5000
V571BA60
575
730
2100
70000
805
910
1000
1420
4500
V661BA60
660
850
2300
70000
940
1050
1160
1640
4000
V751BA60
750
970
2600
70000
1080
1200
1320
1880
3500
V881BA60
880
1150
3200
70000
1290
1500
1650
2340
2700
V112BB60
1100
1400
3800
70000
1620
1800
2060
2940
2200
V142BB60
1400
1750
5000
70000
2020
2200
2550
3600
1800
V172BB60
1700
2150
6000
70000
2500
2700
3030
4300
1500
V202BB60
2000
2500
7500
70000
2970
3300
3630
5200
1200
V242BB60
2400
3000
8600
70000
3510
3900
4290
6200
1000
V282BB60
2800
3500
10000
70000
4230
4700
5170
7400
800
NOTE: Average power dissipation of transients not to exceed 2.5W. See Figures 3 and 4 for more information on power dissipation.
w w w. l i t t e l f u s e . c o m
73
2
VARISTOR
PRODUCTS
Absolute Maximum Ratings
Next
Previous
Varistor Products
High Energy Industrial
BA/BB Varistor Series
Power Dissipation Ratings
100
PERCENT OF RATED VALUE
Should transients occur in rapid succession, the average power dissipation
required is simply the energy (watt-seconds) per pulse times the number
of pulses per second. The power so developed must be within the
specifications shown on the Device Ratings and Characteristics table for
the specific device. Furthermore, the operating values need to be derated
at high temperatures as shown in Figure 1. Because varistors can only
dissipate a relatively small amount of average power they are, therefore,
not suitable for repetitive applications that involve substantial amounts of
average power dissipation.
90
80
70
60
50
40
30
20
10
0
-55
50
60
70
80
90
100
110
120
130
140 150
PERCENT OF PEAK VALUE
AMBIENT TEMPERATURE ( oC)
100
O1 = Virtual Origin of Wave
T = Time From 10% to 90% of Peak
T1 = Virtual Front Time = 1.25 • t
T2 = Virtual Time to Half Value (Impulse Duration)
90
50
Example: For an 8/20µs Current Waveform:
8µs = T1 = Virtual Front Time
20µs = T2 = Virtual Time to Half Value
10
O1
T
TIME
T1
T2
FIGURE 2. PEAK PULSE CURRENT TEST WAVEFORM
Typical Performance Curves
TYPICAL TEMPERATURE COEFFICIENT
OF POWER DISSIPATION = 2.2%/ oC
0.5
MAX AT TA = 85oC
POWER DISSIPATION (W) PER kV
OF RATED V RMS
POWER DISSIPATION (W) PER kV
OF RATED V RMS
1.0
0.8
1,000 HOURS, TA = 85oC
0.6
0.4
0.2
MAX AT TA = 25oC
0.1
0.08
TYP AT TA = 25oC
0.06
0.04
80
90
100
0.2
0.1
0
PERCENTAGE OF MAXIMUM RATED V RMS (%)
74
0.3
0
110
FIGURE 3. STANDBY POWER DISSIPATION vs APPLIED
VRMS AT VARIED TEMPERATURES
0.4
10
100
TIME AT RATED V RMS (HOURS)
FIGURE 4. TYPICAL STABILITY OF STANDBY POWER
DISSIPATION AT RATED V RMS vs TIME
w w w. l i t t e l f u s e . c o m
1,000
Next
Previous
Varistor Products
High Energy Industrial
BA/BB Varistor Series
Transient V-I Characteristics Curves
TA = -55oC TO 85oC
3,000
2,000
30,000
V511BA60
V481BA60
V421BA60
MAX CLAMPING VOLTAGE
DISC SIZE 60mm
1100 TO 2800VM(AC) RATING
TA = -55oC TO 85oC
20,000
V881BA60
V751BA60
V661BA60
V571BA60
1,000
900
800
700
600 V321BA60
500 V271BA60
V251BA60
400
10,000
9,000
8,000
7,000
6,000
2
VARISTOR
PRODUCTS
MAX CLAMPING VOLTAGE
DISC SIZE 60mm
130 TO 880VM(AC) RATING
MAX PEAK VOLTS (V)
MAXIMUM PEAK VOLTS (V)
6,000
5,000
4,000
V282BB60
5,000 V242BB60
4,000 V202BB60
V172BB60
3,000 V142BB60
300 V151BA60
V112BB60
V131BA60
200
10-2
10-1
100
101
102
103
PEAK AMPERES (A)
104
2,000
10-2
105
FIGURE 5. CLAMPING VOLTAGE FOR V131BA60 - V881BA60
10-1
100
101
102
PEAK AMPERES (A)
103
104
105
FIGURE 6. CLAMPING VOLTAGE FOR V112BB60 - V282BB60
Pulse Rating Curves
50,000
20,000
1
2
10
DISC SIZE 60mm
V131BA60 - V321BA60
100,000
20,000
5,000
102
2,000
103
1,000
104
500
105
200
100 106
50
20
10
20
2
10
10,000
SURGE CURRENT (A)
SURGE CURRENT (A)
10,000
DISC SIZE 60mm
V421BA60 - V282BB60
1
50,000
5,000
102
2,000
103
1,000
104
500
105
200
100
106
50
INDEFINITE
100
20
1,000
IMPULSE DURATION (µs)
FIGURE 7. SURGE CURRENT RATING CURVES FOR
V131BA60 - V321BA60
10,000
10
20
INDEFINITE
100
1,000
10,000
IMPULSE DURATION ( µs)
FIGURE 8. SURGE CURRENT RATING CURVES FOR
V421BA60 - V282BB60
NOTE: If pulse ratings are exceeded, a shift of V N(DC) (at specified current) of more than ±10% could result.This type of shift, which normally results in a decrease of VN(DC),
may result in the device not meeting the original published specifications, but it does not prevent the device from continuing to function, and to provide ample protection.
w w w. l i t t e l f u s e . c o m
75
Next
Previous
Varistor Products
High Energy Industrial
BA/BB Varistor Series
Mechanical Dimensions
BA SERIES
BB SERIES
100±1 (3.94± .039")
CL
7.0
(0.28)
23.5±.75 (.925± .030")
NOTES:
1. Typical weight:
BA............................................................................................ ..250g
BB...............................................................................................600g
Dimensions are in mm; inches in parentheses for reference only.
Ordering Information
V XX X XX 60
VARISTOR
DISC SIZE (60mm)
SERIES DESIGNATOR
VM(AC)
First Significant Digits
VM(AC)
Decade Multiplier