96722.pdf

REVISIONS
LTR
DESCRIPTION
A
DATE (YR-MO-DA)
Update boilerplate to reflect current requirements. -rrp
APPROVED
01-05-21
R. MONNIN
REV
SHEET
REV
SHEET
REV STATUS
REV
A
A
A
A
A
A
A
A
A
A
A
OF SHEETS
SHEET
1
2
3
4
5
6
7
8
9
10
11
PMIC N/A
PREPARED BY
Sandra Rooney
STANDARD
MICROCIRCUIT
DRAWING
THIS DRAWING IS AVAILABLE
FOR USE BY ALL
DEPARTMENTS
AND AGENCIES OF THE
DEPARTMENT OF DEFENSE
AMSC N/A
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216
http://www.dscc.dla.mil
CHECKED BY
Sandra Rooney
APPROVED BY
Michael A. Frye
MICROCIRCUIT, LINEAR, RADIATION
HARDENED, TRIPLE LINE TRANSMITTER,
MONOLITHIC SILICON
DRAWING APPROVAL DATE
95-11-20
REVISION LEVEL
A
SIZE
CAGE CODE
A
67268
SHEET
DSCC FORM 2233
APR 97
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
1 OF
5962-96722
11
5962-E424-01
1. SCOPE
1.1 Scope. This drawing documents two product assurance class levels consisting of high reliability (device classes Q and
M) and space application (device class V). A choice of case outlines and lead finishes are available and are reflected in the
Part or Identifying Number (PIN). When available, a choice of Radiation Hardness Assurance (RHA) levels are reflected in the
PIN.
1.2 PIN. The PIN is as shown in the following example:
5962
R
96722
Federal
stock class
designator
\
RHA
designator
(see 1.2.1)
01
V
X
C
Device
type
(see 1.2.2)
Device
class
designator
(see 1.2.3)
Case
outline
(see 1.2.4)
Lead
finish
(see 1.2.5)
/
\/
Drawing number
1.2.1 RHA designator. Device classes Q and V RHA marked devices meet the MIL-PRF-38535 specified RHA levels and
are marked with the appropriate RHA designator. Device class M RHA marked devices meet the MIL-PRF-38535, appendix A
specified RHA levels and are marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device.
1.2.2 Device type(s). The device type(s) identify the circuit function as follows:
Device type
Generic number
Circuit function
01
HS245RH
Radiation hardened DI triple line
transmitter
1.2.3 Device class designator. The device class designator is a single letter identifying the product assurance level as
follows:
Device class
Device requirements documentation
M
Vendor self-certification to the requirements for MIL-STD-883 compliant, nonJAN class level B microcircuits in accordance with MIL-PRF-38535, appendix A
Q or V
Certification and qualification to MIL-PRF-38535
1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows:
Outline letter
C
X
Descriptive designator
CDIP2-T14
CDFP3-F14
Terminals
Package style
14
14
Dual-in-line
Flat package
1.2.5 Lead finish. The lead finish is as specified in MIL-PRF-38535 for device classes Q and V or MIL-PRF-38535,
appendix A for device class M.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-96722
A
REVISION LEVEL
A
SHEET
2
1.3 Absolute maximum ratings. 1/
Supply voltage .............................................................................................
Output voltage .............................................................................................
Input voltage ................................................................................................
Storage temperature range .........................................................................
Maximum package power dissipation at TA = +125C (PD):
Case outline C ..........................................................................................
Case outline X ..........................................................................................
Thermal resistance, junction-to-case (JC):
Case outline C ..........................................................................................
Case outline X ..........................................................................................
Thermal resistance, junction-to-ambient (JA):
Case outline C ..........................................................................................
Case outline X ..........................................................................................
Lead temperature (soldering, 10 seconds) ..................................................
Junction temperature (TJ) ............................................................................
-0.5 V dc to +10 V dc
-30 V with respect to VCC
-0.5 V dc to +10 V dc
-65C to +150C
0.68 W 2/
0.43 W 2/
24C/W
30C/W
74C/W
116C/W
+275C
+175C
1.4 Recommended operating conditions.
Operating voltage range .............................................................................. +4.5 V dc to +5.5 V dc
Ambient operating temperature range (T A) .................................................. -55C to +125C
1.5 Radiation features:
Maximum total dose available (dose rate = 50 – 300 Krad/s) ......................
Dose rate upset ............................................................................................
Dose rate latch-up ........................................................................................
Neutron .........................................................................................................
5
2 x 10 Rads (Si)
9
1 x 10 Rads (Si)/s
None 3/
12
2
5 x 10 N/cm
2. APPLICABLE DOCUMENTS
2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a
part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in
the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the
solicitation.
SPECIFICATION
DEPARTMENT OF DEFENSE
MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for.
STANDARDS
DEPARTMENT OF DEFENSE
MIL-STD-883 MIL-STD-1835 -
Test Method Standard Microcircuits.
Interface Standard Electronic Component Case Outlines.
1/
Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the
maximum levels may degrade performance and affect reliability.
2/ If device power exceeds package dissipation capacity, provide heat sinking or derate linearly (the derating is based on JA)
at the following rates:
Case outline C ............................................... 13.5 mW/C
Case outline X ............................................... 8.6 mW/ C
3/ Guaranteed by process or design, not tested.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-96722
A
REVISION LEVEL
A
SHEET
3
HANDBOOKS
DEPARTMENT OF DEFENSE
MIL-HDBK-103 MIL-HDBK-780 -
List of Standard Microcircuit Drawings.
Standard Microcircuit Drawings.
(Unless otherwise indicated, copies of the specification, standards, and handbooks are available from the Standardization
Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text
of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item requirements for device classes Q and V shall be in accordance with
MIL-PRF-38535 and as specified herein or as modified in the device manufacturer's Quality Management (QM) plan. The
modification in the QM plan shall not affect the form, fit, or function as described herein. The individual item requirements for
device class M shall be in accordance with MIL-PRF-38535, appendix A for non-JAN class level B devices and as specified
herein.
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified
in MIL-PRF-38535 and herein for device classes Q and V or MIL-PRF-38535, appendix A and herein for device class M.
3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.4 herein.
3.2.2 Terminal connections. The terminal connections shall be as specified on figure 1.
3.2.3 Load circuit and switching waveform. The load circuit and switching waveform shall be as specified on figure 2.
3.2.4 Radiation exposure circuit. The radiation exposure circuit shall be as specified in table III.
3.3 Electrical performance characteristics and postirradiation parameter limits. Unless otherwise specified herein, the
electrical performance characteristics and postirradiation parameter limits are as specified in table I and shall apply over the full
ambient operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table IIA. The electrical
tests for each subgroup are defined in table I.
3.5 Marking. The part shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturer's PIN may also be
marked as listed in MIL-HDBK-103. For packages where marking of the entire SMD PIN number is not feasible due to space
limitations, the manufacturer has the option of not marking the "5962-" on the device. For RHA product using this option, the
RHA designator shall still be marked. Marking for device classes Q and V shall be in accordance with MIL-PRF-38535.
Marking for device class M shall be in accordance with MIL-PRF-38535, appendix A.
3.5.1 Certification/compliance mark. The certification mark for device classes Q and V shall be a "QML" or "Q" as required in
MIL-PRF-38535. The compliance mark for device class M shall be a "C" as required in MIL-PRF-38535, appendix A.
3.6 Certificate of compliance. For device classes Q and V, a certificate of compliance shall be required from a QML-38535
listed manufacturer in order to supply to the requirements of this drawing (see 6.6.1 herein). For device class M, a certificate of
compliance shall be required from a manufacturer in order to be listed as an approved source of supply in MIL-HDBK-103 (see
6.6.2 herein). The certificate of compliance submitted to DSCC-VA prior to listing as an approved source of supply for this
drawing shall affirm that the manufacturer's product meets, for device classes Q and V, the requirements of MIL-PRF-38535
and herein or for device class M, the requirements of MIL-PRF-38535, appendix A and herein.
3.7 Certificate of conformance. A certificate of conformance as required for device classes Q and V in MIL-PRF-38535 or for
device class M in MIL-PRF-38535, appendix A shall be provided with each lot of microcircuits delivered to this drawing.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-96722
A
REVISION LEVEL
A
SHEET
4
TABLE I. Electrical performance characteristics.
Test
Symbol
Conditions 1/
-55C TA +125C
unless otherwise specified
Group A
subgroups
Device
type
Limits
Unit
Input low current
IIL
VCC = 5.5 V 2/
1,2,3
01
Min
-2.8
ON output current
IOUT
“ON”
VCC = 4.5 V and 5.5 V
2/ 3/
1,2,3
01
-5.6
ON output current
unbalance
IOUT
VCC = 5.5 V
1,2,3
01
OFF output current
IOUT
“OFF”
VCC = 4.5 V 2/
1,2,3
01
-100
A
Output breakdown
BVCER
VCC = 0 V 5/
1,2,3
01
-30
V
Power supply current
ICC
VCC = 5.5 V 6/ 7/
1
01
21
mA
Propagation delay
TPLH
TPHL
VCC = 4.5 V and 5.5 V
See figure 2
9,10,11
01
14
ns
4/
Max
mA
-1.0
mA
380
A
1/ Devices supplied to this drawing have been characterized through all levels M, D, P, L, R of irradiation. However, this
device is only tested at the “R” level. Pre and Post irradiation values are identical unless otherwise specified in Table I.
When performing post irradiation electrical measurements for any RHA level, TA = +25C.
2/ One input at GND, one input open, each output at GND.
3/ One input at 0.45 V, one input open, each output at GND.
4/ Difference between 1 and 2 “ON” output data current.
5/ Each input at GND, one output at GND, ILIMIT > -100 A on output tested with –30 V applied.
6/ One input of each transmitter at GND and the other input open. All six output lines at GND.
7/ All six input lines open, all six output lines at GND.
3.8 Notification of change for device class M. For device class M, notification to DSCC-VA of change of product (see 6.2
herein) involving devices acquired to this drawing is required for any change as defined in MIL-PRF-38535, appendix A.
3.9 Verification and review for device class M. For device class M, DSCC, DSCC's agent, and the acquiring activity retain
the option to review the manufacturer's facility and applicable required documentation. Offshore documentation shall be made
available onshore at the option of the reviewer.
3.10 Microcircuit group assignment for device class M. Device class M devices covered by this drawing shall be in
microcircuit group number 53 (see MIL-PRF-38535, appendix A).
4. QUALITY ASSURANCE PROVISIONS
4.1 Sampling and inspection. For device classes Q and V, sampling and inspection procedures shall be in accordance with
MIL-PRF-38535 or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan
shall not affect the form, fit, or function as described herein. For device class M, sampling and inspection procedures shall be
in accordance with MIL-PRF-38535, appendix A.
4.2 Screening. For device classes Q and V, screening shall be in accordance with MIL-PRF-38535, and shall be conducted
on all devices prior to qualification and technology conformance inspection. For device class M, screening shall be in
accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices prior to quality conformance inspection.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-96722
A
REVISION LEVEL
A
SHEET
5
Device types
Case outlines
Terminal number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
01
C and X
Terminal symbol
INPUT 1 1
OUTPUT 1 1
OUTPUT 1 2
INPUT 1 2
INPUT 2 1
OUTPUT 2 1
SUBSTRATE GND
OUTPUT 2 2
INPUT 2 2
INPUT 3 1
OUTPUT 3 1
OUTPUT 3 2
INPUT 3 2
VCC
FIGURE 1. Terminal connections.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-96722
A
REVISION LEVEL
A
SHEET
6
NOTES:
Input: TTLH 10 ns
TTHL 10 ns
pw = 500 ns
f = 1 MHz
IOUT = VOUT/50 FIGURE 2. Load circuit and switching waveform.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-96722
A
REVISION LEVEL
A
SHEET
7
4.2.1 Additional criteria for device class M.
a.
Burn-in test, method 1015 of MIL-STD-883.
(1) Test condition A, B, C or D. The test circuit shall be maintained by the manufacturer under document revision
level control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in
test method 1015.
(2) TA = +125C, minimum.
b.
Interim and final electrical test parameters shall be as specified in table IIA herein.
4.2.2 Additional criteria for device classes Q and V.
a.
The burn-in test duration, test condition and test temperature, or approved alternatives shall be as specified in the
device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be maintained under
document revision level control of the device manufacturer's Technology Review Board (TRB) in accordance with
MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test
method 1015 of MIL-STD-883.
b.
Interim and final electrical test parameters shall be as specified in table IIA herein.
c.
Additional screening for device class V beyond the requirements of device class Q shall be as specified in
MIL-PRF-38535, appendix B.
4.3 Qualification inspection for device classes Q and V. Qualification inspection for device classes Q and V shall be in
accordance with MIL-PRF-38535. Inspections to be performed shall be those specified in MIL-PRF-38535 and herein for
groups A, B, C, D, and E inspections (see 4.4.1 through 4.4.4).
4.4 Conformance inspection. Technology conformance inspection for classes Q and V shall be in accordance with
MIL-PRF-38535 including groups A, B, C, D, and E inspections and as specified herein. Quality conformance inspection for
device class M shall be in accordance with MIL-PRF-38535, appendix A and as specified herein. Inspections to be performed
for device class M shall be those specified in method 5005 of MIL-STD-883 and herein for groups A, B, C, D, and E inspections
(see 4.4.1 through 4.4.4).
4.4.1 Group A inspection.
a.
Tests shall be as specified in table IIA herein.
b.
Subgroups 4, 5, 6, 7, and 8 in table I, method 5005 of MIL-STD-883 shall be omitted.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-96722
A
REVISION LEVEL
A
SHEET
8
TABLE IIA. Electrical test requirements.
Test requirements
Interim electrical
parameters (see 4.2)
Final electrical
parameters (see 4.2)
Group A test
requirements (see 4.4)
Group C end-point electrical
parameters (see 4.4)
Group D end-point electrical
parameters (see 4.4)
Group E end-point electrical
parameters (see 4.4)
Subgroups
(in accordance with
MIL-STD-883,
method 5005, table I)
Device
class M
1
Subgroups
(in accordance with
MIL-PRF-38535, table III)
1
1, 2, 3,
9, 10, 11
1, 2, 3,
9, 10, 11
1, 2, 3, 9
1, 2, 3,
9, 10, 11
1, 2, 3,
9, 10, 11
1, 2, 3, 9
Device
class Q
1/
Device
class V
1
1/
1
1
1, 2, 3, 2/ 3/
9, 10, 11
1, 2, 3,
9, 10, 11
1, 2, 3, 3/
9, 10, 11
1
1
1
1
1/ PDA applies to subgroup 1.
2/ PDA applies to subgroups 1 and .
3/ Delta limits as specified in table IIB herein shall be required where specified, and the delta
values shall be completed with reference to the zero hour electrical parameters (see table I).
TABLE IIB. Burn-in delta parameters and group C delta parameters (+25C).
PARAMETER
Input leakage current
ON output current
OFF output current
Power supply current
SYMBOL
IIL
IOUT(ON)
IOUT(OFF)
ICC
DELTA LIMITS
280 nA
560 A
20 A
2.1 mA
TABLE III. Irradiation test connections. TA = +25C 5C
GROUND
1, 2, 3, 6, 7, 8, 9,
11, 12, 13
+5.5 0.5 V
4, 5, 10, 14
4.4.2 Group C inspection. The group C inspection end-point electrical parameters shall be as specified in table IIA herein.
4.4.2.1 Additional criteria for device class M. Steady-state life test conditions, method 1005 of MIL-STD-883:
a.
Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify
the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test method
1005 of MIL-STD-883.
b.
TA = +125C, minimum.
c.
Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-96722
A
REVISION LEVEL
A
SHEET
9
4.4.2.2 Additional criteria for device classes Q and V. The steady-state life test duration, test condition and test temperature,
or approved alternatives shall be as specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The
test circuit shall be maintained under document revision level control by the device manufacturer's TRB in accordance with
MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall specify
the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test method 1005 of
MIL-STD-883.
4.4.3 Group D inspection. The group D inspection end-point electrical parameters shall be as specified in table IIA herein.
4.4.4 Group E inspection. Group E inspection is required only for parts intended to be marked as radiation hardness
assured (see 3.5 herein). RHA levels for device classes M, Q and V shall be as specified in MIL-PRF-38535. End-point
electrical parameters shall be as specified in table IIA herein.
4.4.4.1 Total dose irradiation testing. Total dose irradiation testing shall be performed in accordance with MIL-STD-883
method 1019, condition A and as specified herein.
4.4.4.1.1 Accelerated aging testing. Accelerated aging testing shall be performed on all devices requiring a RHA level
greater than 5k rads (Si). The post-anneal end-point electrical parameter limits shall be as specified in table I herein and shall
be the pre-irradiation end-point electrical parameter limits at 25C 5C. Testing shall be performed at initial qualification and
after any design or process changes which may affect the RHA response of the device.
4.4.4.2 Dose rate induced latchup testing. Dose rate induced latchup testing shall be performed in accordance with test
method 1020 of MIL-STD-883 and as specified herein (see 1.5 herein). Tests shall be performed on devices, SEC, or approved
test structures at technology qualification and after any design or process changes which may effect the RHA capability of the
process.
4.4.4.3 Dose rate upset testing. Dose rate upset testing shall be performed in accordance with test method 1023 of
MIL-STD-883 and herein (see 1.5 herein).
a.
Transient dose rate upset testing shall be performed at initial qualification and after any design or process changes
which may affect the RHA performance of the devices. Test 10 devices with 0 defects unless otherwise specified.
b.
Transient dose rate upset testing for class Q and V devices shall be performed as specified by a TRB approved
radiation hardness assurance plan and MIL-PRF-38535.
4.4.4.4 Dose rate burnout. When required by the customer, test shall be performed on devices, SEC, or approved test
structures at technology qualifications and after any design or process changes which may effect the RHA capability of the
process. Dose rate burnout shall be performed in accordance with test method 1023 of MIL-STD-883 and as specified herein.
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535 for device
classes Q and V or MIL-PRF-38535, appendix A for device class M.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
(original equipment), design applications, and logistics purposes.
6.1.1 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor
prepared specification or drawing.
6.1.2 Substitutability. Device class Q devices will replace device class M devices.
6.2 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
6.3 Record of users. Military and industrial users should inform Defense Supply Center Columbus when a system
application requires configuration control and which SMD's are applicable to that system. DSCC will maintain a record of users
and this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering
microelectronic devices (FSC 5962) should contact DSCC-VA, telephone (614) 692-0544.
6.4 Comments. Comments on this drawing should be directed to DSCC-VA , Columbus, Ohio 43216-5000, or telephone
(614) 692-0547.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-96722
A
REVISION LEVEL
A
SHEET
10
6.5 Abbreviations, symbols, and definitions. The abbreviations, symbols, and definitions used herein are defined in
MIL-PRF-38535 and MIL-HDBK-1331.
6.6 Sources of supply.
6.6.1 Sources of supply for device classes Q and V. Sources of supply for device classes Q and V are listed in QML-38535.
The vendors listed in QML-38535 have submitted a certificate of compliance (see 3.6 herein) to DSCC-VA and have agreed to
this drawing.
6.6.2 Approved sources of supply for device class M. Approved sources of supply for class M are listed in MIL-HDBK-103.
The vendors listed in MIL-HDBK-103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been
submitted to and accepted by DSCC-VA.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
5962-96722
A
REVISION LEVEL
A
SHEET
11
STANDARD MICROCIRCUIT DRAWING BULLETIN
DATE: 01-05-21
Approved sources of supply for SMD 5962-96722 are listed below for immediate acquisition information only and
shall be added to MIL-HDBK-103 and QML-38535 during the next revision. MIL-HDBK-103 and QML-38535 will be
revised to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a
certificate of compliance has been submitted to and accepted by DSCC-VA. This bulletin is superseded by the next
dated revision of MIL-HDBK-103 and QML-38535.
Standard
microcircuit drawing
PIN 1/
5962R9672201QCC
5962R9672201QXC
5962R9672201VCC
5962R9672201VXC
Vendor
CAGE
number
34371
34371
34371
34371
Vendor
similar
PIN 2/
HS1-245RH-8
HS9-245RH-8
HS1-245RH-Q
HS9-245RH-Q
1/ The lead finish shown for each PIN representing
a hermetic package is the most readily available
from the manufacturer listed for that part. If the
desired lead finish is not listed contact the vendor
to determine its availability.
2/ Caution. Do not use this number for item
acquisition. Items acquired to this number may not
satisfy the performance requirements of this drawing.
Vendor CAGE
number
34371
Vendor name
and address
Intersil Corporation
P.O. Box 883
Melbourne, FL 32902-0883
The information contained herein is disseminated for convenience only and the
Government assumes no liability whatsoever for any inaccuracies in the
information bulletin.