2014050312183571741

Test Report.
No. CANEC1406041601
Date: 30 Apr 2014 .
Page 1 of 5.
GUANGZHOU CITY GETE ELECTRONICS CO,.LTD .
ROOM212,NO.171HUIFUXI ROAD,GUANGZHOU CITY,CHINA
.
.
The following sample(s) was/were submitted and identified on behalf of the clients as : HIGH VOLTAGE
DIODE.
SGS Job No. :
CP14-021253 - GZ .
Lot No. :.
2014.
Date of Sample Received : .
25 Apr 2014.
Testing Period : .
Test Requested : .
Test Method : .
25 Apr 2014 - 30 Apr 2014 .
Selected test(s) as requested by client. .
Please refer to next page(s). .
Test Results :.
Please refer to next page(s). .
Conclusion :.
Based on the performed tests on submitted samples, the results of Lead,
Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBB),
Polybrominated diphenyl ethers (PBDE) comply with the limits as set by RoHS
Directive 2011/65/EU Annex II; recasting 2002/95/EC. .
Signed for and on behalf of
SGS-CSTC Ltd. .
Yan Lee .
Approved Signatory .
Test Report.
No. CANEC1406041601
Date: 30 Apr 2014 .
Page 2 of 5.
Test Results :.
Test Part Description : .
Specimen No..
SN1.
SGS Sample ID.
CAN14-060416.001
Description.
Silvery metal.
SN2.
CAN14-060416.002
Black plastic w/ blue printing .
Remarks :.
(1) 1 mg/kg = 1 ppm = 0.0001% .
(2) MDL = Method Detection Limit .
(3) ND = Not Detected ( < MDL ) .
(4) "-" = Not Regulated .
RoHS Directive 2011/65/EU.
Test Method : . (1)With reference to IEC 62321-5:2013, determination of Cadmium by ICP-OES.
(2)With reference to IEC 62321-5:2013, determination of Lead by ICP-OES.
(3)With reference to IEC 62321-4:2013, determination of Mercury by ICP-OES.
(4)With reference to IEC 62321:2008, determination of Hexavalent Chromium by Colorimetric
Method using UV-Vis.
(5)With reference to IEC 62321:2008, determination of PBBs and PBDEs by GC-MS. .
Test Item(s).
Cadmium (Cd) .
Limit.
Unit.
MDL.
002.
100
mg/kg.
2
ND
Lead (Pb).
1,000
mg/kg.
2
5
Mercury (Hg).
1,000
mg/kg.
2
ND
Hexavalent Chromium (CrVI) .
1,000
mg/kg.
2
ND
Sum of PBBs .
1,000
mg/kg.
-
ND
Monobromobiphenyl .
-
mg/kg.
5
ND
Dibromobiphenyl .
-
mg/kg.
5
ND
Tribromobiphenyl .
-
mg/kg.
5
ND
Tetrabromobiphenyl .
-
mg/kg.
5
ND
Pentabromobiphenyl .
-
mg/kg.
5
ND
Hexabromobiphenyl .
-
mg/kg.
5
ND
Heptabromobiphenyl .
-
mg/kg.
5
ND
Octabromobiphenyl .
-
mg/kg.
5
ND
Nonabromobiphenyl .
-
mg/kg.
5
ND
Decabromobiphenyl .
-
mg/kg.
5
ND
1,000
mg/kg.
-
ND
Sum of PBDEs .
Test Report.
No. CANEC1406041601
Date: 30 Apr 2014 .
Limit.
Unit.
MDL.
002.
Monobromodiphenyl ether .
-
mg/kg.
5
ND
Dibromodiphenyl ether .
-
mg/kg.
5
ND
Tribromodiphenyl ether .
-
mg/kg.
5
ND
Tetrabromodiphenyl ether .
-
mg/kg.
5
ND
Pentabromodiphenyl ether .
-
mg/kg.
5
ND
Hexabromodiphenyl ether .
-
mg/kg.
5
ND
Heptabromodiphenyl ether .
-
mg/kg.
5
ND
Octabromodiphenyl ether .
-
mg/kg.
5
ND
Nonabromodiphenyl ether .
-
mg/kg.
5
ND
Decabromodiphenyl ether .
-
mg/kg.
5
ND
Test Item(s).
Page 3 of 5.
Notes :.
(1) The maximum permissible limit is quoted from the directive 2011/65/EU, Annex II .
RoHS Directive 2011/65/EU.
Test Method : . (1)With reference to IEC 62321-5:2013, determination of Cadmium by ICP-OES.
(2)With reference to IEC 62321-5:2013, determination of Lead by ICP-OES.
(3)With reference to IEC 62321-4:2013, determination of Mercury by ICP-OES.
(4)With reference to IEC 62321:2008, determination of Hexavalent Chromium by spot test /
Colorimetric Method using UV-Vis. .
Test Item(s).
Limit.
Unit.
MDL.
001.
Cadmium (Cd) .
100
mg/kg.
2
ND
Lead (Pb).
1,000
mg/kg.
2
86
Mercury (Hg).
1,000
mg/kg.
2
ND
-
-
♢
Negative
Hexavalent Chromium (CrVI) .
Notes :.
(1) The maximum permissible limit is quoted from the directive 2011/65/EU, Annex II
(2)◇Spot-test:
Negative = Absence of CrVI coating, Positive = Presence of CrVI coating;
(The tested sample should be further verified by boiling-water-extraction method if the spot test result is
Negative or cannot be confirmed.)
◇Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is
equal or greater than 0.02 mg/kg with 50 cm2 sample surface area.
Information on storage conditions and production date of the tested sample is unavailable
and thus Cr(VI) results represent status of the sample at the time of testing. .
Test Report.
No. CANEC1406041601
Date: 30 Apr 2014 .
Page 4 of 5.
ATTACHMENTS
RoHS Testing Flow Chart
1) Name of the person who made testing: Michael Tso / Cutey Yu
2) Name of the person in charge of testing: Adams Yu / Yolanda Wei
3) These samples were dissolved totally by pre -conditioning method according to below flow chart
(Cr6+ and PBBs/PBDEs test method excluded ).
Sample Preparation
Sample Measurement
Pb/Cd/Hg
Acid digestion with
microwave/ hotplate
Sample solvent
extraction
Filtration
Concentration/
Dilution of extraction
solution
Solution
Residue
Filtration
1) Alkali Fusion /
Dry Ashing
2) Acid to
dissolve
ICP-OES/AAS
DATA
Cr6+
PBBs/PBDEs
GC-MS
DATA
Nonmetallic
material
Adding digestion
reagent
Heating to
90~95℃ for
extraction
Filtration and
pH adjustment
Adding 1,5diphenylcarbazide
for color
development
Metallic
material
Positive
Spot test
Negative
Boiling water
extraction
Adding 1,5diphenylcarbazide
for color
development
UV-Vis
A red color
indicates the
presence of Cr 6+. If
necessary , confirm
with UV-Vis.
DATA
DATA
Test Report.
No. CANEC1406041601
Date: 30 Apr 2014 .
Sample photo: .
CANEC1406041601
CAN14-060416.001 .
CANEC1406041601
CAN14-060416.002 .
SGS authenticate the photo on original report only .
*** End of Report *** .