Specification Sheet

C4800D Series
EURO SERIES DC/DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
•
2400 - 5000W
DC/DC Converter Industrial Grade
High Operating Temp
Hot Plugable
Wide Input Voltage
Configurable Options
Eurocassette Mounting
Wall Mounting
Chassis Mounting
SPECIFICATIONS
INPUT
ENVIRONMENTAL
Operating temperature
-20°C to +75°C
(optional -40 to 75C)
Load derating
Derate 2.5% per °C, from +55°C to 75°C
1-2 seconds.
Cooling
H: Heatsink - natural convection
F: Fan - increased airflow recommended
TF: Temperature controlled Fan included
See selection table
Voltage range; 4.5 - 400Vdc
See selection table
Environment Options
Option c: Extended temperature range to -40°C
Storage temperature
-40°C to +85°C
Humidity
Up to 95% RH, non-condensing
Input voltage
DC Input voltage: 10 - 800Vdc
See selection table
Units will turn off with under or over input voltage.
No-load input power
5-6W model (series dependent)
Switch on time
OUTPUT
Output voltage
Output current
See selection table.
Ripple & noise
1% + 30mVpp
Line regulation
0.1% (±10%)
Load regulation
0.2% typical, load step 10-90%
Load transient
6% typical, load step 10-90%
STANDARDS
EMI standards
acc. to EN61000-6-4 class A, optionally class B
Immunity standards
acc. to EN61000-6-2
C-Tick
AS/NZS CISPR11: 2002 Group1 Class A
Safety / Construction
acc. to EN60950-1 / EN50178
IP20 acc. to EN60529
NEMA or others on request
Response time
2-3ms typical ±1%
Temperature coefficient
0.02% per °C typical.
Holdup time
10mS at 220VAC typical
Protection category
Turn on rise time
100mS typical (soft start)
MECHANICAL
Remote sensing
Standard for all series
Efficiency
80%-92% typical
Mounting
Output Options
Option dd: Decoupling Diode for redundant /
parallel operation
Option cs: Active Current Sharing
Option h: Remote on/off (inhibit)
Option dr: DC OK via relay contacts
See technical illustrations
Eurocassette, pluggable module for 19" subrack
Option w: Wall Mounting
Option cha: Chassis Mounting
Dimensions
See Technical illustration
Overload protection
Current limited at 105%–110% of full load.
Mechanical Options
Overvoltage protection
OVP switches off module with automatic return
to operation
Protection Options
Option i: Inrush Current Limiting
Option sd: Reverse polarity protection for DC input
by Series Diode
MTBF
100Khrs to 140Khrs at 40°C
acc. to MIL-HDBK-217E (notice 1)
Connector
PROTECTION
19" Rack Mounting Options
www.powerbox.com.au - 1800 251 380
www.powerbox.co.nz - 0800 104 480
H15 acc. to DIN 41612 H15
and high current connectors for I > 50A,
or terminals / bolts / bars
Option ms: Increased Mechanical Strength
Option t: Tropical protection
Subrack Height 3U, 5U, 6U
Wiring, Front Panels
Accessories: Fuses, MCBs, Mains on/off switch
Contact Powerbox for rack configuration
Doc. No. C4800D Rev.E 10-02-16
C4800D Series
EURO SERIES DC/DC CONVERTER
SELECTION TABLE
INPUT OUTPUT INPUT OUTPUT INPUT
10-16V AMPS
20-32V AMPS
40-64V
INPUT
50-80V
OUTPUT INPUT
INPUT
INPUT
INPUT
INPUT
OUTPUT
OUTPUT OUTPUT
COOLING
AMPS
80-160V 160-320V 320-380V 320-640V 450- 800V AMPS
VDC
RANGE
C4802 136
C4822
190
C4832
C4842
240
C4852
C4872
C4882Z
C4872G
C4872K
260
F
12
11 - 13
C4803 116
C4823
160
C4833
C4843
200
C4853
C4873
C4883Z
C4873G
C4873K
220
F
15
14 - 16
C4804 92
C4824
120
C4834
C4844
150
C4854
C4874
C4884Z
C4874G
C4874K
160
F
24
23 - 26
C4805 80
C4825
100
C4835
C4845
130
C4855
C4875
C4885Z
C4875G
C4875K
140
F
28
26 - 30
C4809 44
C4829
60
C4839
C4849
76
C4859
C4879
C4889Z
C4879G
C4879K
80
F
48
45 - 55
C4806 36
C4826
50
C4836
C4846
62
C4856
C4876
C4886Z
C4876G
C4876K
66
F
60
58 - 68
C4807 20
C4827
26
C4837
C4847
36
C4857
C4877
C4887Z
C4877G
C4877K
40
F
110
100 - 130
C4807J 12
C4827J 14
C4837J C4847J 20
C4857J
C4877J
C4887ZJ C4877GJ C4877KJ
20
F
200
190 - 200
C4808 10
C4828
C4838
C4858
C4878
C4888Z
20
F
220
200 - 250
C4808J 6
C4828J 7
C4858J
C4878J
C4888ZJ C4878GJ C4878KJ
10
F
400
380 - 400
Note: Cooling
14
C4848
20
C4838J C4848J 10
C4878G
C4878K
H: Heatsink - Natural Convection / F: Fan - increased airflow recommended / TF: Temperature controlled Fan included
See selection table
OPTIONS
Model Designation:
Add the designation of options to the model number, eg. C2560-dd-dr-cs
Options for Input, Output, Environmental and Mechanical follow.
19" Rack Mounting:
Subrack Height 3U, 5U, 6U
Wiring, Front Panels
Accessories: Fuses, MCBs, Mains on/off switch
Contact Powerbox for rack configuration
INPUT OPTIONS
Option “i”
(inrush current limiting): A thermistor is connected in series with the input lines which changes its resistance from high to low when it
gets hot. It does not reduce the current surge if the input power is interrupted for a short period of time not allowing the thermistor to
cool down. Thermistors are fitted as standard to all mains input models except for 1-phase input of models > 2.5kW. Thermistors are
available up to 45A. For higher input current an electronic inrush current limitation can be offered.
Option “ie”
electronic inrush current limiting An electronic circuit limits the inrush current.
Option “sd”
(series diode): A series diode protects the module against input voltage of wrong polarity (additional power losses).
Option “ad”
(anti-parallel diode): To avoid the power losses of a series diode a diode is provided with opposite polarity in parallel to the input
blowing an internal or external fuse if the module is connected to a supply with wrong polarity.
Option “au”
(auto-ranging) For standard dual AC input models the range of 115/230Vac is to be selected by connecting the input line to different
pins on the connector. With auto-ranging the unit senses the input voltage and provides automatically the correct connection.
Option “p”
(power fail): A signal (logic or relay) is given if the input voltage (AC or DC) drops below the specified limit.
In AC input units we sense the rectified input voltage so that a power fail alarm will not be triggered if at light loads mains power
returns before the input capacitors are substantially discharged.
Option “r”
(relay): A relay instead of a logic signal is provided for failure indication.
OUTPUT OPTIONS
Option “dd”
Option “cs”
Option “csi”
Option “h1”
(decoupling diode): For redundant operation the outputs of two or more units are paralleled behind de-coupling diodes so that an
internal fault of one module does not affect the operation of the others. These diodes cause power losses.
(active current sharing): An additional control circuit provides active current sharing via an interconnecting wire between converters
that operate in parallel. Active current sharing should be used for multi-output units operating inparallel.
(current sharing interrupt): Option "csi" will effect the removal of the "cs" signal. Should there be an instance where a unit is not
supplying the load, then the effect of its "cs" signal is removed, and the load voltage is unaffected by this condition.
(inhibit): A terminal connected to the negative input line also shuts off the converter.
This can also be used in conjunction with a thermal trip which shuts the unit down.
Option “h2”
(inhibit): Operation of the unit is inhibited if a voltage signal (5V/10mA) is applied in reference to the negative line of the (main) output.
Option “rco”
(reducing current limiting at over temperature) A circuit reduces the current limiting level at higher temperature (to be specified).
Option “d”
(DC-ok, one output): A logic signal is given if the output voltage (main output in multi-output systems) is below the specified limit.
Option “m”
(DC-ok, all outputs): In multi-output systems a logic signal is provided if the voltage of any output is below the specified limit.
Option “ac”
(AC ok) A logic signal connected to relay contacts is given if the output voltage of an inverter is below the specified limit.
Option "y"
(sys-reset): This logic signal is a combination of power fail and DC-ok as specified for VME systems.
Option "r"
(relay): A relay instead of a logic signal is provided for failure indication.
www.powerbox.com.au - 1800 251 380
www.powerbox.co.nz - 0800 104 480
Doc. No. C4800D Rev.E 10-02-16
C4800D Series
EURO SERIES DC/DC CONVERTER
OPTIONS
ENVIRONMENT OPTIONS
Option "t"
Option "c"
Option "ms"
(tropical protection):The unit is given additional protection by a heavy
coat of varnish on the printed circuit board(s) and components.
(extended temperature range):The circuit is designed and tested for
operation at an ambient temperature as low as –40 °C.
(increased mechanical strength): Screws are secured by Locktite and
heavy components are fastened by ties and/or glue. Modules with the "ms" option
meet the standard EN61373 regarding shock and vibration.
MECHANICAL OPTIONS
Standard mounting
"Eurocassette" pluggable module for 19" sub-racks 8
Option "w"
(wall mounting): Module is screwed against a mounting plate for
installation in a cabinet. The load connections are typically a terminal block.
Option "cha"
Option "din"
(chassis mount) Module is designed for installation to a structure or
within cabinet. Screw type connectors are supplied with the module.
(DIN rail mount) Module is designed for DIN rail mounting to a
structure or within Cabinet. Screw type connectors are supplied with the module.
TECHNICAL ILLUSTRATIONS