データシート

For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
date
03/19/2015
page
1 of 5
SERIES: SDI120-U │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
level VI efficiency
120 W power
universal input (90~264 Vac)
single regulated outputs
over voltage and short circuit protections
UL/cUL, GS, PSE safety approvals
power factor correction
custom designs available
MODEL
output
voltage
output
current
output
power
ripple
and noise1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
SDI120-12-U
12
9
108
120
VI
SDI120-16-U
16
7.5
120
160
VI
SDI120-19-U
19
6.3
120
190
VI
SDI120-24-U
24
5
120
240
VI
SDI120-48-U
48
2.5
120
480
VI
Notes:
efficiency
level
1. At full load, nominal input, 20 MHz bandwidth oscilloscope, each output terminated with 0.1 μF multilayer ceramic and 10 μF low ESR electrolytic capacitors.
PART NUMBER KEY
SDI120 - XX - UX - P51 - CXX
Base Number
AC Inlet Type:
IEC320/C14
Reserved for Custom
Configurations
Output Voltage
Input Cable:
“Blank” = No Cable
C = North America input cable
2 = Europe input cable
3 = United Kingdom input cable
4 = Australia input cable
5 = China input cable
6 = South Korea input cable
7 = Brazil input cable
8 = South Africa input cable
9 = Japan input cable
cui.com
DC Plug Type:
4 Pin Power DIN
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: SDI120-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 03/19/2015 │ page 2 of 5
INPUT
parameter
conditions/description
min
voltage
90
frequency
47
typ
current
inrush current
at 230 Vac, full load, 25°C, cold start
leakage current
power factor correction
at full load
no load power consumption
at 230 Vac
max
units
264
Vac
63
Hz
1.6
A
80
A
3.5
mA
0.21
W
max
units
0.9
OUTPUT
parameter
conditions/description
min
regulation
typ
±5
%
PROTECTIONS
parameter
conditions/description
min
over voltage protection
over current protection
short circuit protection
output shut down, auto recovery
typ
max
units
output latch
150
%
output shut down, auto recovery
170
%
max
units
SAFETY & COMPLIANCE
parameter
conditions/description
min
isolation voltage
input to output at 10 mA for 1 minute
isolation resistance
input to output at 500 Vdc
safety approvals
UL/cUL, GS, PSE
EMI/EMC
FCC Part 15B Class B, CE
MTBF
as per Telcordia SR-332, 25°C
RoHS
2011/65/EU
typ
3,000
Vac
10
MΩ
300,000
hrs
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
storage temperature
max
units
0
typ
40
°C
-20
80
°C
operating humidity
non-condensing
20
80
%
storage humidity
non-condensing
10
90
%
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: SDI120-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 03/19/2015 │ page 3 of 5
MECHANICAL
parameter
conditions/description
dimensions
168.1 x 65.9 x 39
min
inlet plug
IEC320/C14
weight
without ac cord: 19 Vdc model
without ac cord: 16, 24 Vdc models
without ac cord: 12, 48 Vdc models
typ
max
units
mm
560
580
630
MECHANICAL DRAWING
units: mm
DC CORD
units: mm
cord length
Table 1
MODEL NO.
CABLE
CORD LENGTH
SDI120-12-U
UL1185, 14 AWG
1,200 mm ±30
SDI120-16-U
UL1185, 14 AWG
1,500 mm ±30
SDI120-19-U
UL1185, 16 AWG
1,500 mm ±30
SDI120-24-U
UL1185, 16 AWG
1,500 mm ±30
SDI120-48-U
UL1185, 18 AWG
1,500 mm ±30
cui.com
g
g
g
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: SDI120-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 03/19/2015 │ page 4 of 5
AC CORD
units: mm
cord length
NORTH AMERICA
EUROPE
UNITED KINGDOM
AUSTRALIA
CHINA
SOUTH KOREA
BRAZIL
SOUTH AFRICA
JAPAN
Table 2
AC INPUT
CORD LENGTH
North America
1,830 mm ±30
Europe
1,830 mm ±30
United Kingdom
1,830 mm ±30
Australia
1,830 mm ±30
China
1,830 mm ±30
South Korea
1,830 mm ±50
Brazil
1,830 mm ±30
South Africa
1,830 mm ±50
Japan
1,830 mm ±30
cui.com
For more information, please visit the product page
|
For information on related products, view Dc Power Jacks
CUI Inc │ SERIES: SDI120-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 03/19/2015 │ page 5 of 5
REVISION HISTORY
rev.
1.0
description
date
initial release
03/19/2015
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.