LITTELFUSE 424

SURFACE MOUNT FUSES
No. 424 / X-SMQ
This product is not recommended
for new designs. Please refer to
Littelfuse No. 154.
UL 248-14, 125V
125V,, F
Specifications
Holder with mounted fuse No. 419
Packaging
Time-Current Characteristic
Quick acting (F)
Materials of the Holder
Standard
Housing:
Terminals:
UL 248-14
CSA C22.2 No. 248.14
Approvals
Holder plastics UL94 V-O
Copper alloy, Ni+Sn plated,
lead free
Operating TTemperature
emperature
cULus Recognized
-55ºC to +125ºC (consider de-rating)
Features
Climatic Category
-55ºC/+125ºC/21 days (IEC 60068-2-1...3)
Easy exchange of the fuse
For line or low voltage applications
Low voltage drop
Internationally approved
High pulse resistance
For reflow soldering
Dimensions (mm)
010: Blister tape 38 cm reel (1500 pcs.)
tape width 16 mm
Stock Conditions
+10ºC to +60ºC
relative humidity ≤ 75% yearly average,
without dew, maximum value for 30 days-95%
V ibration Resistance
W ebLinks
24 cycles at 15 min. each (IEC 60068-2-6)
10 - 60Hz at 0.75mm amplitude
60 - 2000Hz at 10g acceleration
Further info see:
www.wickmanngroup.com
Further application info see Fuseology:
3,7
www.wickmann.com/download/fuseology.pdf
Solderability
235ºC, 3 sec. (IEC 60068-2-58)
Soldering Heat Resistance
260ºC, 10 sec. (IEC 60068-2-58)
280°C, 5 sec.
Minimum Cross Section, Copper
5
10
Conducting path - 0.1mm 2
Thickness - 0.035mm
Pad Layout
4,24+0,05
Mounting
4,24+0,05
2,13+0,05
3,81+0,05
Avoid circuit traces below the fuse
Marking on fuse
F, Current Rating
*)
Limits for Pre-arcing Time
62mA ... 7.00A
0.4g (approx.)
2.0 x IN
< 5s
Permissible continuous operating current is ≤ 70% at ambient temperature of 23ºC (73.4ºF).
Rated
Amp
Voltage
Breaking Voltage Drop Power Dissipation
Current
code
Rating
Capacity
1.0 x IN
1.0 x IN
typ. (mV)
typ. (mW)
62mA
125mA
250mA
500mA
750mA
1.00A
1.50A
2.00A
2.50A
3.00A
4.00A
5.00A
7.00A
0062
0125
0250
0500
0750
1100
1150
1200
1250
1300
1400
1500
1700
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
Melting Integral
10 x IN
min. (A2s) typ.
Approbationen
cURus
Rated Current
Unit Weight
50A/125VAC/DC
50-60Hz
cos ϕ = 1.0
1600
1300
950
360
350
210
250
180
220
160
140
130
85
120
150
200
300
230
500
400
550
600
670
750
0.00014
0.00085
0.0065
0.093
0.25
0.50
1.10
1.10
1.20
2.00
4.30
7.50
0.000095
0.00067
0.0052
0.074
0.20
0.42
0.95
0.90
0.95
1.70
3.42
6.80
•
•
•
•
•
•
•
•
•
•
•
•
35A/125VAC
100A / 125VDC
50-60Hz
cos ϕ = 1.0
130
1200
13.60
11.60
•
*) Please note: The holder no. 424 is lead-free, but not the inserted fuse no. 419
Order
Information
050912
Qty.
OrderNumber
WebSite
Europe Tel: +49 2302 662-107
www.wickmanngroup.com E-mail: [email protected]
Series
424
Amp Code
Americas Tel: +1 404 699-7820
E-mail: [email protected]
Packaging
Asia Tel: +852 26 14-1108
E-mail: [email protected]
Specifications are subject
to change without notice
China Tel: +86 21 6432 5146
E-mail: [email protected]
SURFACE MOUNT FUSES
00
0,0
10
No. 424 / X-SMQ
I-t Characteristics
(Min-Max Limit)
0
,00
10
UL 248-14
Test value
0
1,0
0
10
Time (sec.)
0
10
1
0.1
1
0.0
01
0.0
1
1.5
2
3
4
5
6
7 8 9 10
15
I Fault / I Rated
Contact WICKMANN for individual I-t curves
050912
WebSite
Europe Tel: +49 2302 662-107
www.wickmanngroup.com E-mail: [email protected]
Americas Tel: +1 404 699-7820
E-mail: [email protected]
Asia Tel: +852 26 14-1108
E-mail: [email protected]
China Tel: +86 21 6432 5146
E-mail: [email protected]