SERIES: PDS2-M │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
2 W isolated output
smaller package
single unregulated output
1,500 Vdc isolation
short circuit protection
extended temperature range (-40~105°C)
high efficiency at light load
efficiency up to 84%
MODEL
PDS2-S5-S3-M
input
voltage
output
voltage
output
current
output
power
ripple
and noise1
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
typ
(mVp-p)
typ
(%)
5
4.5~5.5
3.3
40
400
1.32
100
78
PDS2-S5-S5-M
5
4.5~5.5
5
40
400
2
100
79
PDS2-S5-S9-M
5
4.5~5.5
9
22
222
2
100
82
PDS2-S5-S12-M
5
4.5~5.5
12
17
167
2
100
82
PDS2-S5-S15-M
5
4.5~5.5
15
13
133
2
100
83
PDS2-S12-S5-M
12
10.8~13.2
5
40
400
2
100
79
PDS2-S12-S9-M
12
10.8~13.2
9
22
222
2
100
82
PDS2-S12-S12-M
12
10.8~13.2
12
17
167
2
100
82
PDS2-S12-S15-M
12
10.8~13.2
15
13
133
2
100
83
PDS2-S12-S24-M
12
10.8~13.2
24
8
83
2
100
84
PDS2-S15-S15-M
15
13.5~16.5
15
13
133
2
100
83
PDS2-S24-S5-M
24
21.6~26.4
5
40
400
2
100
79
PDS2-S24-S9-M
24
21.6~26.4
9
22
222
2
100
82
PDS2-S24-S12-M
24
21.6~26.4
12
17
167
2
100
82
PDS2-S24-S15-M
24
21.6~26.4
15
13
133
2
100
83
PDS2-S24-S24-M
24
21.6~26.4
24
8
83
2
100
84
Notes:
1. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PDS2-M │ DESCRIPTION: DC-DC CONVERTER
date 08/13/2015 │ page 2 of 7
PART NUMBER KEY
PDS2 - SXX - S XX - M - X
Base Number
Input Voltage
Output
S = single
Output Voltage
Packaging Style
SMT
Packaging Options
"blank" = standard
TR = Tape & Reel
INPUT
parameter
conditions/description
min
typ
max
units
operating input voltage
5 Vdc input models
12 Vdc input models
15 Vdc input models
24 Vdc input models
4.5
10.8
13.5
21.6
5
12
15
24
5.5
13.2
16.5
26.4
Vdc
Vdc
Vdc
Vdc
surge voltage
for maximum of 1 second
5 Vdc input models
12 Vdc input models
15 Vdc input models
24 Vdc input models
-0.7
-0.7
-0.7
-0.7
9
18
21
30
Vdc
Vdc
Vdc
Vdc
filter
capacitance filter
max
units
±1.5
±1.2
%
%
OUTPUT
parameter
conditions/description
line regulation
for Vin change of 1%
3.3 Vdc output models
all other models
min
load regulation
measured from 10% load to full load
3.3 Vdc output models
5 Vdc output models
9 Vdc output models
12 Vdc output models
15 Vdc output models
24 Vdc output models
voltage accuracy
see tolerance envelope curve
switching frequency
100% load, nominal input voltage
temperature coefficient
100% load
typ
18
12
9
8
7
6
%
%
%
%
%
%
100
kHz
±0.03
%/°C
max
units
1
s
max
units
PROTECTIONS
parameter
conditions/description
min
typ
short circuit protection1
Notes:
1. The supply voltage must be discontinued at the end of the short circuit duration
SAFETY AND COMPLIANCE
parameter
conditions/description
min
isolation voltage
input to output for 1 minute at 1 mA max.
1,500
Vdc
isolation resistance
input to output at 500 Vdc
1,000
MΩ
conducted emissions
CISPR22/EN55022 class B (external circuit required, see Figure 1)
radiated emissions
CISPR22/EN55022 class B (external circuit required, see Figure 1)
ESD
IEC/EN61000-4-2, class B, contact ± 8kV
MTBF
as per MIL-HDBK-217F at 25°C
RoHS
2011/65/EU
3,500,000
cui.com
typ
hours
For more information, please visit the product page.
CUI Inc │ SERIES: PDS2-M │ DESCRIPTION: DC-DC CONVERTER
date 08/13/2015 │ page 3 of 7
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curve
-40
105
°C
-55
125
°C
95
%
storage temperature
storage humidity
non-condensing
temperature rise
at full load, Ta = 25°C
typ
25
°C
SOLDERABILITY
parameter
conditions/description
hand soldering
reflow soldering
min
max
units
1.5 mm from case for 10 seconds
300
°C
see reflow soldering profile
245
°C
Temperature(°C)
2 50
2 45
2 17
2 00
°C ( M a x .)
P e a k . Te m p 2 4 5 6 0 S e c M ax
( > 2 1 7°C )
1 50
1 00
50
0
typ
Time (sec.)
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PDS2-M │ DESCRIPTION: DC-DC CONVERTER
date 08/13/2015 │ page 4 of 7
MECHANICAL
parameter
conditions/description
dimensions
12.70 x 11.20 x 7.25 (0.500 x 0.441 x 0.285 inch)
min
case material
epoxy resin (UL94-V0)
weight
typ
max
mm
1.6
g
MECHANICAL DRAWING
units: mm[inch]
tolerance: ±0.25[±0.010]
pin section tolerance: ±0.10[±0.004]
PIN CONNECTIONS
PIN
FUNCTION
1
GND
2
Vin
4
0V
5
+Vo
8
NC
NC: No Connection
Top View
Side View
Front View
Top View
PCB Layout
cui.com
units
For more information, please visit the product page.
CUI Inc │ SERIES: PDS2-M │ DESCRIPTION: DC-DC CONVERTER
date 08/13/2015 │ page 5 of 7
DERATING CURVES
Tolerance Envelope Curve
(3.3 Vdc output only)
10
2.5
0
-2.5
-5
-7.5
-10
10
20
Typ
i
Typica
l
0
cal
Load
-5
Max
Loa
Line
1.0
Rated Output Voltage
dL
in
1.0
e
Rated Output Voltage
Min
-10
-7.5
-7.5
-15
-15
30
10
40
50
60
70
Output Current Percentage (%)
20
40
60
80
(Nominal Input Voltage)
80
90
-15
Output Voltage Accuracy (%)
5
5
Tolerance Envelope Curve (all other output models)
10
Output Voltage Accuracy (%)
Output Voltage Accuracy (%)
7.5
Output Voltage Accuracy (%)
10 Envelope Curve (3.3Vdc output model)
Tolerance
10
Tolerance Envelope Curve
(all other models)
7.5
5
Typic
a
5
l Loa
d Lin
e
0
-2.5
-5
-7.5
2.5
Rated Output Voltage
Typica
lM
Loin
ad Lin
e
2.5
0
Max
-5
-2.5
2.5
Rated Output Voltage
-7.5
-2.5
-10
-7.5
-15
-10
100
10
20
10
100
30
40
50
60
70
(%)
20 Output
40 Current
60 Percentage
80
100
(Nominal Input Voltage)
80
90
100
Output Current Percentage (%)
(Nominal Input Voltage)
Output Current Percentage (%)
(Nominal Input Voltage)
Temperature Derating Curve
all other models
Load (%)
100
5 Vdc output models
80
Safe operating area
60
50
40
20
-40
-20
0
20
40
60 71
85
105
120
Ambient Temperature (°C)
EMC RECOMMENDED CIRCUIT
Figure 1
Table 1
Recommended external circuit components
LDM
Vin
Vin
C1
G ND
C2
+Vo
DC / DC
G ND
C out
LO AD
0V
Vin
(Vdc)
C1
5
12
C2
CY1
LDM
4.7μF/50V
4.7μF/50V
--
6.8μH
4.7μF/50V
4.7μF/50V
--
6.8μH
15
4.7μF/50V
4.7μF/50V
--
6.8μH
24
4.7μF/50V
4.7μF/50V
1nF/2kV
6.8μH
Note:
CY
cui.com
1. CY of 1nF/2kV required for PDS2-S12-S24-M
2. See Table 2 for Cout values
For more information, please visit the product page.
CUI Inc │ SERIES: PDS2-M │ DESCRIPTION: DC-DC CONVERTER
date 08/13/2015 │ page 6 of 7
APPLICATION NOTES
1. Output load requirement
To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during
operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load.
2. Overload Protection
Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add
this is to add a circuit breaker to the circuit.
3. Recommended circuit
If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low
ESR (see Figure 2 & Table 2). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too
high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance
must be less than the maximum capacitive load (see Table 3).
Figure 2
+Vo
V in
DC
Cin
DC
Cout
GND
0V
Table 3
Table 2
Note:
Vin
(Vdc)
Cin
(µF)
Vo
(Vdc)
Cout
(µF)
Vout
(Vdc)
Max. Capacitive Load
(μF)
5
4.7
3.3
10
3.3
220
12
2.2
5
10
5
220
15
2.2
9
4.7
9
220
24
1
12
2.2
12
220
--
--
15
1
15
220
--
--
24
0.47
24
220
1. Operation under minimum load will not damage the converter; however, they may not meet all specifications listed.
2. Max. capacitive load tested at input voltage range and full load.
3. All specifications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specified.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PDS2-M │ DESCRIPTION: DC-DC CONVERTER
date 08/13/2015 │ page 7 of 7
REVISION HISTORY
rev.
description
date
1.0
initial release
04/08/2014
1.01
updated tolerance envelope curves, discontinued models
08/13/2015
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.