データシート

For more information, please visit the product page.
date
01/20/2015
page
1 of 5
SERIES: VASD1-SIP │ DESCRIPTION: DC-DC CONVERTER
1 W isolated output
industry standard 7 pin SIP package
dual unregulated outputs
1,000 V isolation
short circuit protection
UL safety approvals
wide temperature (-40~85°C)
efficiency up to 80%
U
•
•
•
•
•
•
•
•
ED
FEATURES
MODEL
input
voltage
typ
(Vdc)
range
(Vdc)
(Vdc)
5
4.5~5.5
±5
output
current
output
power
ripple
and noise1
efficiency
min
(mA)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
±10
±100
1
75
72
TI
VASD1-S5-D5-SIP
output
voltage
N
RoHS
VASD1-S5-D9-SIP
5
4.5~5.5
±9
±6
±56
1
75
75
VASD1-S5-D12-SIP
5
4.5~5.5
±12
±5
±42
1
75
78
5
4.5~5.5
±15
±4
±33
1
75
79
VASD1-S12-D5-SIP
12
10.8~13.2
±5
±10
±100
1
75
74
VASD1-S12-D9-SIP
12
10.8~13.2
±9
±6
±56
1
75
76
VASD1-S12-D12-SIP
12
10.8~13.2
±12
±5
±42
1
75
79
VASD1-S12-D15-SIP*
12
10.8~13.2
±15
±4
±33
1
75
80
VASD1-S24-D5-SIP
24
21.6~26.4
±5
±10
±100
1
75
74
24
21.6~26.4
±9
±6
±56
1
75
76
24
21.6~26.4
±12
±5
±42
1
75
80
24
21.6~26.4
±15
±4
±33
1
75
81
VASD1-S24-D12-SIP
VASD1-S24-D15-SIP
1. ripple and noise are measured at 20 MHz BW
* Discontinued model
IS
C
Notes:
O
VASD1-S24-D9-SIP
N
VASD1-S5-D15-SIP
D
PART NUMBER KEY
Base Number
VASD1 - SXX - DXX -SIP
Input Voltage
Output Voltage
cui.com
Packaging Style
For more information, please visit the product page.
CUI Inc │ SERIES: VASD1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 01/20/2015 │ page 2 of 5
INPUT
conditions/description
min
typ
max
units
operating input voltage
5 V model
12 V model
24 V model
4.5
10.8
21.6
5
12
24
5.5
13.2
26.4
Vdc
Vdc
Vdc
parameter
conditions/description
min
typ
max
units
line regulation
for Vin change of 1%
1.2
%
load regulation
measured from 10% load to full load
5 V model
9 V model
12 V model
15 V model
15
15
15
15
%
%
%
%
voltage accuracy
see derating curves
switching frequency
100% load, input voltage range
OUTPUT
PROTECTIONS
conditions/description
SAFETY AND COMPLIANCE
U
min
TI
parameter
short circuit protection
10.5
8.3
6.8
6.3
N
temperature coefficient
ED
parameter
kHz
±0.03
%/°C
typ
units
1
s
max
units
conditions/description
for 1 minute at 1 mA max.
1,000
Vdc
isolation resistance
at 500 Vdc
1,000
MΩ
safety approvals
UL 60950-1 (E222736)
3,500,000
hours
N
parameter
full load at 85°C, 4 hours at no load and 4 hours at full load
RoHS compliant
yes
O
burn-in
typ
max
isolation voltage
MTBF
min
100
ENVIRONMENTAL
parameter
conditions/description
min
IS
C
operating temperature
storage temperature
storage humidity
non-condensing
temperature rise
at full load
lead temperature
1.5 mm from case for 10 seconds
max
units
-40
typ
85
°C
-55
125
°C
95
%
25
°C
300
°C
D
15
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VASD1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 01/20/2015 │ page 3 of 5
DERATING CURVES
2. output voltage vs. output current
ED
1. output power vs. ambient temperature
+10%
Output Voltate (%)
Load (%)
100
80
60
40
-40
-20
0
20
40
60
85
105 120
N
conditions/description
0.772 x 0.236 x 0.394 (19.60 x 6.00 x 10.00 mm)
min
case material
plastic (UL94-V0)
N
TI
parameter
1
IS
C
0.90 [0.035]
(Side View)
typ
max
units
inch
2.1
g
6.00 [0.236]
O
19.60 [0.772]
100%
Output Current (%)
dimensions
units: mm [inches]
tolerance: ±0.25 [±0.010]
pin section tolerance: ±0.10 mm [±0.004]
50%
10%
MECHANICAL
MECHANICAL DRAWING
-2.5%
-7.5%
Ambient Temperature (°C)
weight
+2.5%
Voltage
U
20
+5%
Nominal
10.00 [0.394]
(Bottom View)
2
4 5 6
0.50[0.020]
0.30 [0.012]
2.54 [0.100]
∅1.00 [0.039]
1 2
4.10 [0.161]
4 5
6
2.54 [0.100]
2.54 [0.100]
0.50 [0.020]
D
2.00 [0.079]
cui.com
PIN CONNECTIONS
PIN
FUNCTION
1
+Vin
2
-Vin
4
-Vo
5
COM
6
+Vo
For more information, please visit the product page.
CUI Inc │ SERIES: VASD1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 01/20/2015 │ page 4 of 5
APPLICATION NOTES
ED
1. Requirement on Output Load
In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded and the
minimum output load is not less than 10% load. If the actual load is less than the specified minimum load, the output ripple may
increase sharply while its efficiency and reliability will reduce greatly. If the actual output power is very small, please add an
appropriate resistor as extra loading.
2. Overload Protection
Under normal operating conditions, the output circuit of these products has no protection against over-current and short-circuits. The
simplest method is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit.
TI
N
U
3. Filtering
In some circuits which are sensitive to noise and ripple, a filtering capacitor may be added to the DC/DC output end and input end to
reduce the noise and ripple. However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a
startup problem might arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest
capacitance of its filter capacitor sees the external capacitor table. To get an extremely low ripple, an “LC” filtering network may be
connected to the input and output ends of the DC/DC converter, which may produce a more significant filtering effect. It should also
be noted that the inductance and the frequency of the “LC” filtering network should be staggered with the DC/DC frequency to avoid
mutual interference (Figure 1).
L
L
+Vo
Vin
Cout
Figure 1
0V
Cin
DC DC
L Cout
GND
-Vo
4. Output Voltage Regulation and Over-voltage Protection Circuit
The simplest device for output voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat
protection that is connected to the input or output end in series (Figure 2).
R EG
N
Vi n
Figure 2
GND
REG
DC DC
+Vout
0V
REG
-Vout
O
5. External Capacitor Table
It is not recommended to connect any external capacitor in the application field with less than 0.5 W output.
Vin
(Vdc)
Vout
(Vdc)
Cout
(µF)
5
4.7
±5
4.7
12
2.2
±9
2.2
24
1
±12
1
--
--
±15
0.47
D
IS
C
Table 1
Cout
(µF)
Note:
All specifications measured at 25°C, humidity <75%, nominal input voltage, and full load unless otherwise noted.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VASD1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 01/20/2015 │ page 5 of 5
REVISION HISTORY
description
date
09/01/2009
1.0
initial release
1.01
new template applied
1.02
V-Infinity branding removed
1.03
updated derating curve
1.04
ED
rev.
04/06/2012
09/04/2012
03/18/2013
discontinued model VASD1-S12-D15-SIP
01/20/2015
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.