Hydrogen generators
Features and Benefits
• Ultra safe operation
zero air generators
ultra high purity
Hydrogen generators
Features and Benefits
• Ultra safe operation
• >99.999% purity
• >99.9999% purity
• High purity guaranteed, 24/7
• High purity guaranteed, 24/7
• Class leading PEM cell featuring
2-year warranty as standard
• Class leading PEM cell featuring
2-year warranty as standard
• CE, UL & CSA approved
• CE, UL & CSA approved
• Low life cycle cost, excellent return
on investment
• Low life cycle cost, excellent
return on investment
Features and Benefits
• High performance heated platinum
catalyst
lc/ms nitrogen
generators
Features and Benefits
• Continuous automatic operation,
24/7
• High efficiency filtration
• Phthalate-free componentry
• Modular and stackable with all
PerkinElmer hydrogen generators
• Low life cycle cost, excellent return
on investment
• CE, UL & CSA approved
• CE, UL & CSA approved
• Low life cycle cost, excellent return
on investment
• Safe and sustainable
• Superior resolution and lowered
limits of detection
• Safe and sustainable
• Field proven Pressure Swing
Adsorption (PSA) technology
• Compact and robust design
Product Selection
Hydrogen Gas Generators for Fuel Gas Applications
Flow Rate Purity
Model
Part No.
(mL/min)
(%)
Water Consumption
(24/7, full flow)
(L/week)
Delivery
Pressure Height (H)
Width (W) Depth (D)
(psi/g)
(in.)
(in.)
(in.)
Weight
(Empty)
(lbs.)
20H
40H
60H
1.25
2
4
5-100
5-100
5-100
41.9
41.9
41.9
N9303225 160
N9303226 250
N9303227 500
>99.999
>99.999
>99.999
17.9
17.9
17.9
13.5
13.5
13.5
17.2
17.2
17.2
Ultra High Purity Hydrogen Gas Generators for Carrier Gas Applications
Flow Rate Purity
Model
Part No.
(mL/min)
(%)
Water Consumption
(24/7, full flow)
(L/week)
Delivery
Pressure Height (H)
Width (W) Depth (D)
(psi/g)
(in.)
(in.)
(in.)
Weight
(Empty)
(lbs.)
20H-MD N9303201
40H-MD N9303202
60H-MD N9303203
110H-MD N9303204
1.69
2.41
4.82
10.60
10-100
10-100
10-100
10-100
45.2
45.2
45.2
51.8
160
250
500
1100
>99.999
>99.999
>99.999
>99.999
Ambient Temperature Range
Water Quality
Maximum Water Supply Pressure/Flow* Supply Voltage Range
Port Connections
Hydrogen Outlet
Water Drain
17.9
17.9
17.9
17.9
13.5
13.5
13.5
13.5
18.5
18.5
18.5
18.5
41-104 ˚F
Deionized, ASTM® II, >1MΩ, <1 µs, filtered to <100 µm
1.45 psi g / 1 L/min
Universal 120/230 V ±10% (60/50 Hz)
1/8” Compression Fitting
Quick Release Push in Fitting
*With Auto Water Refill option
Zero Air Generators
Part No.
Part No.
Model
(120 V)
(230 V)
Flow
Rate
(L/min)
Organic
Purity
(ppm)
Air Inlet @
58-145 psig
(L/m)
Delivery
Pressure Height (H) Width (W) Depth (D) Weight
(psi/g)
(in.)
(in.)
(in.)
(lbs.)
UHP-35ZA-S
UHP-50ZA-S
UHP-150ZA-S
UHP-300ZA-S
3.5
5.0
15
30
<0.1
<0.1
<0.1
<0.1
4.2
6.0
18
35
58-145
58-145
58-145
58-145
N9303206
N9303208
N9303210
N9303212
N9303205
N9303207
N9303209
N9303211
Ambient Temperature Range Required Inlet Air Quality
Supply Voltage Range
Port Connections
Outlet (N9303205 and N9303206)
Inlet (N9303205 and N9303206)
Outlet (N9303207-N9303212
Inlet (N9303207-N9303212)
17.9
17.9
17.9
17.9
13.4
13.4
13.4
13.4
16.7
16.7
16.7
16.7
31.3
31.3
31.3
31.3
41-104 ˚F
Clean dry compressed air ISO8573-1:2001 Class 3.2.1
120 V/60 Hz or 230 V/50-60 Hz ±10%
1/8” Compression Fitting
1/8” Compression Fitting
1/4” Compression Fitting
1/4” Compression Fitting
LC/MS Nitrogen Generators
Part No.
Part No.
Model
(120 V)
(230 V)
Flow
Rate
Purity
(L/min)
(ppm)
Delivery
Pressure
Height (H)
Width (W)
Depth (D)
(psi/g)
(in.)
(in.)
(in.)
Weight
(lbs.)
With integrated compressor
LCMS30-1
N9303223 N930224
30
101.5
298
>98
Ambient Temperature Range
Supply Voltage Range
Port Connections Nitrogen Outlet
27.8
20.1
41-104 ˚F
120 V/60 Hz or 230 V/50-60 Hz ±10%
1/4” Compression Fitting
*Visit www.perkinelmer.com for a complete listing of flow rates.
PerkinElmer, Inc.
940 Winter Street
Waltham, MA 02451 USA
P: (800) 762-4000 or
(+1) 203-925-4602
www.perkinelmer.com
For a complete listing of our global offices, visit www.perkinelmer.com/ContactUs
Copyright ©2011, PerkinElmer, Inc. All rights reserved. PerkinElmer® is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners.
009582_01
22.9