RL801S
THRU
RL807S
GLASS PASSIVATED SILICON RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 8.0 Amperes
FEATURES
Low leakage
Low forward voltage drop
High current capability
High surge capability
High reliability
.049 (1.25 REF.)
D2-PAK
MECHANICAL DATA
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
.412 (10.46)
.388 (9.86)
o
Ratings at 25 C ambient temperature unless otherwise specified.
.098 (2.50)
.083 (2.10)
.202 (5.13)
.198 (5.03)
.055 (1.40)
.047 (1.20)
.036 (0.91)
.028 (0.71)
.069 (1.75)
.626 (15.89)
.578 (14.69)
.337 (8.55)
.321 (8.15)
Case: D2-PAK molded plastic
Epoxy: Device has UL flammability classification 94V-O
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 1.4 grams
.126 (3.20)
.110 (2.80)
*
*
*
*
*
.189 (4.80)
.173 (4.40)
.053 (1.35)
.049 (1.25)
.053 (1.35)
*
*
*
*
*
.020 (0.50)
.012 (0.30)
PIN 1
Single phase, half wave, 60 Hz, resistive or inductive load.
K - HEATSINK
PIN 2
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
RL801S
RL802S
RL803S
RL804S
RL805S
RL806S
RL807S
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
Volts
VDC
50
100
200
400
600
800
1000
Volts
RATINGS
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
o
at T C = 100 C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Current Squared Time
Typical Thermal Resistance (Note 1)
Typical Junction Capacitance (Note 2)
Operating and Storage Temperature Range
IO
8.0
Amps
I FSM
125
Amps
2
It
64.8
A /S
R Q JC
3.6
R Q JA
25
CJ
40
T J, T STG
-55 to + 150
2
0
C/ W
pF
0
C
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 8.0A DC
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@T A = 25 o C
o
@T A = 100 C
SYMBOL
RL801S
VF
IR
NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted.
2. Measured at 1 MHz and applied reverse voltage of 4.0 volts.
3. "Fully ROHS compliant", "100% Sn plating (Pb-free)".
4. Available in Halogen-free epoxy by adding suffix -HF after the part nbr.
RL802S
RL803S
RL804S
1.0
RL805S
RL806S
RL807S
UNITS
Volts
1.0
50
uAmps
2015-02
REV:O
RATING AND CHARACTERISTICS CURVES ( RL801S THRU RL807S )
INSTANTANEOUS FORWARD CURRENT, (A)
AVERAGE FORWARD CURRENT, (A)
10
8
6
4
Single Phase Half Wave
60 Hz Inductive or
Resistive Load
2
0
0
50
100
150
40
20
10
4
1.0
0.4
0.1
0
O
CASE TEMPERATURE, ( C)
1.0
1.5
2.0
2.5
3.0
3.5
L INSTANTANEOUS
FIG.2 TYPICAL
FORWARD CHAR
RACTERISTICS
200
CT, JUNCTION CAPACITANCE, (pF)
1000
TA = 100 OC
100
10
O
TA = 25 C
1.0
0
20
40
60
80
100
120
100
60
40
20
10
6
4
2
0
140
T J = 25 OC
0.1 0.2
0.4
1.0
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
2
8.3mS Single Half Sine-Wave
JEDEC Method
125
100
75
50
25
2
10
20
40
100
FIG.4 TYPICAL JUNCTION CAPACITANCE
150
0
1
4
REVERSE VOLTAGE, (V)
FIG.3 TYPICAL REVERSE
E CHARACTERISTICS
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, ( A)
0.5
INSTANTANEOUS FORWARD VOLTAGE, (V)
FIG.1 TYPICAL FORWARD CURRENT
DERATIING CURVE
0.1
T A = 25 OC
Pulse Width = 300mS
1% Duty Cycle
5
10
20
50
100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPETITIIVE FORWARD
SURGE CURRENT
Marking Description
V Y W W
Rectron Logo
Part No.
R
L 8
0
X
Year – code
(Y:Last digit of year &
A:2010,B:2011……)
Week – code
(WW:01~52)
Voltage-code
1-------50V
2-------100V
3-------200V
4-------400V
5-------600V
6-------800V
7------1000V
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
BULK PACK
EA PER BOX
INNER BOX SIZE
CARTON SIZE
(mm)
(mm)
EA PER CARTON
GROSS
WEIGHT(Kg)
PACKAGE
PACKING CODE
A-405
-B
1,000
194*84*21
415*220*255
50,000
15.64
BR-3/-6
-B
200
206*208*55
450*220*255
1,600
6.00 / 6.80
BR-8/-10
-B
200
236*236*50
497*251*282
2,000
12.24
BR-15/-25/-35/(W)
-B
50
206*208*57
450*220*255
400
12.50 (14.40)
DO-15
-B
500
194*84*21
415*220*255
25,000
12.74
DO-201
-B
500
300*73*40
347*320*271
12,000
15.90
DO-41
-B
1,000
194*75*21
415*220*255
50,000
16.2
HVM
-B
200
165*214*52
353*226*290
2,000
---
HVP
-B
40
236*236*40
502*251*145
240
8.80
MB-15/-25/-35(W)
-B
50
206*208*57
450*220*255
400
13.60 (14.30)
MP-15/-25/-35(W)
-B
50
206*208*57
450*220*255
400
7.7 (8.26)
R-1/-3
-B
1000 / 500
192*75*21
415*220*255
50,000 / 25,000
11.74 / 16.17
R-6/R-7
-B
200
300*73*40
347*320*271
4,800
12.93 / 14.57
RB-15
-B
1,000
165*252*59
347*320*271
10,000
11.6
RBU
-B
450
240*239*35
502*251*126
2,700
13.00
RC-2
-B
600
165*252*59
347*320*271
6,000
9.4
RS-1
-B
600
240*239*35
497*255*162
4,800
9.264
RS-2L
-B
400
210*160*52
502*251*126
2,400
8.59
RS-4L
-B
300
230*162*52
502*251*126
1,800
11.3
RS-6/-8
-B
200
236*236*34
497*255*162
1,600
13.6 / 14.5
RS-1M
-B
600
240*239*35
497*255*162
4,800
8.62
RS-2M
-B
600
236*236*40
502*251*145
3,600
10.28
RS-4M/-10M
-B
600
236*236*40
497*251*100
2,400
11.09
RS-6/8/15/20/25M
-B
300
230*190*46
410*243*157
1,800
13.37
WOM
-B
600
165*252*59
347*320*271
6,000
11.0
PACKAGE
PACKING CODE
EA PER BOX
INNER BOX SIZE
CARTON SIZE
(mm)
(mm)
EA PER CARTON
WEIGHT(Kg)
BDB
-C
2,000
450*140*84
464*305*283
12,000
14.18
D2PAK
-C
2,000
550*140*92
572*308*120
4,000
10.20
DB-1
-C
2,500
450*140*84
464*305*283
15,000
14.30
DB-LS
-C
4,000
450*140*84
464*305*283
24,000
16.45
DB-S
-C
4,000
450*140*84
464*305*283
24,000
18.44
RBU
-C
1,000
490*135*110
510*293*131
2,000
13.62
RS-1M/-2M
-C
1,350
540*118*118
560*259*144
2,700
12.03
RS-4M/-10M
-C
900
540*118*118
560*259*144
1,800
12.82
RS-6/8/15/20/25M
-C
600
490*135*110
510*293*131
1,200
13.12
(I)TO-220/TO-220(A)
-C
2,000
550*140*92
572*308*120
4,000
11.80
TO-247
-C
900
550*140*92
572*308*120
1,800
7.60
TUBE PACK
Visit http:// www.rectron.com for complete datasheets
D34
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.