8 5 6 7 4 2 3 This document, including the design, configuration and mechanical features revealed herein are the sole, confidential and proprietary property of TRU Corporation. Reproduction or use thereof, in whole or part, is prohibited without the prior written consent of TRU Corporation. 1 REV. DESCRIPTION DATE APPROVED - ORIGINAL ISSUE 05/16/14 TE D D 1.250 (1.250 HEX) C .123 HOLE X .290 DEPTH ENGINEERING DATA C ELECTRICAL: IMPEDANCE: 50 OHMS NOMINAL FREQUENCY RANGE: DC to 6 GHz POWER RATING: 2kW CW @ 4.2 GHz, sea level, room temp, 3:1 VSWR max .274 MECHANICAL: INTERFACE: 7-16(m) per IEC 169-4, DIN 47223 B MATERIAL: CONTACTS: BRASS INSULATOR: FLUOROLOY H OUTER CONDUCTOR: BRASS HOUSING & NUT: BRASS B .142 HOLE 4 PLCS .20 FINISH: CONTACTS: TRULUSTRE PLATING OUTER CONDUCTOR: TRULUSTRE PLATING HOUSING & NUT: TRULUSTRE PLATING .974 TYP. .12 MATERIAL DO NOT SCALE DRAWING UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES A NOTES: 1. UNLESS OTHERWISE SPECIFIED; ALL DIMENSIONS ARE FOR REFERENCE ONLY. TOLERANCES: FRACTIONS: 1/64 .XX : .01 .XXX: .005 ANGLES: 1/2` MACHINED SURFACES: COMMENTS: 1.21 DRAWN TE 8 7 6 5 TRU Corporation 245 Lynnfield St, Peabody, MA 01960 05/15/14 ENG APPR. TE DATE 05/16/14 MFG APPR. DATE OTHER APPR. DATE AM TITLE: 05/16/14 THIRD ANGLE PROJECTION 63 surface area: sq inch DATE SIZE B A CONNECTOR, COAXIAL 7-16(m) PANEL RECEPTACLE DWG. NO. CAGE CODE: 92180 weight: lbs 4 3 2 REV TRU-12695 - SHEET 1 OF 1 SCALE: 3:1 1