DERATING CURVE (Current carrying capacity acc. IEC 60512-5-2 Test 5b)
Current (A]
SMC Minibridge A/P 3p connector with 250 mm stranded flat ribbon cable AWG 26
max component temperature 125°C
7
6
5
4
3
2
Base curve [A]
1
Derating curve [A]
Temperature [°C]
0
Base curve [A]
Derating curve [A]
0
10
20
6,05
4,84
30
5,75
4,60
40
5,40
4,32
50
5,05
4,04
60
4,70
3,76
70
4,30
3,44
80
3,85
3,08
90
3,35
2,68
100
2,80
2,24
110
2,15
1,72
120
1,25
1,00