DERATING CURVE (Current carrying capacity acc. IEC 60512-5-2 Test 5b)
Current (A]
SMC Minibridge A/P 4p connector with 250 mm stranded flat ribbon cable AWG 26
max component temperature 125°C
6
5
4
3
2
Base curve [A]
1
Derating curve [A]
Temperature [°C]
0
Base curve [A]
Derating curve [A]
0
10
20
5,45
4,36
30
5,20
4,16
40
4,90
3,92
50
4,60
3,68
60
4,30
3,44
70
3,95
3,16
80
3,55
2,84
90
3,10
2,48
100
2,60
2,08
110
2,00
1,60
120
1,15
0,92
130