ZM-1758-60

ZM-1758-60
The ZM-1758-60 filter is designed to work with systems
with requirements to meet Mil-Std-461D, E, or F. The
filter is designed so that there are no resonant points in
the operating range. The common mode insertion loss is
also a minimum 50 dB from 100Mhz to 1.0Ghz. This high
frequency performance will suppress high frequency
signals on the power leads that can cause problems with
radiated emissions.
Operating Voltage = _________________28 - 40 Vdc
Operating Current = ______________________ 60 Amp
Operating Temperature = _______________(-55)—85°C
Diel. Withstanding (L-Case) = ____800 Vdc (1.0 Minute)
Calculated MTBF = ________ 2,870,437 Hrs at 30°C GB
Failure rate = __________________________ 0.348379
Ordering Information
P/N: ZM-1758-60
INSERTION LOSS vs. FREQUENCY
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
EUR
JMK Inc
Glasgow, Scotland UK
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
PH: 44 (0) 7785-310729 FX: 44 (0) 1415-891884