Gas System: Series 400 Biogas 480V / 60 Hz - US units [PDF]

GAS SYSTEM
SERIES 400 BIOGAS
480 V / 60 Hz
NOx < 1g/bhp-hr, Alternator UL certified
SYSTEM RATINGS
Gas genset with optional heat recovery
(194°/158°F heating water circuit)
Genset
Type
Engine
Type
MTU 6R400 GS
MTU 6R400 GS
MTU 12V400 GS
B3066 L8
B3066 Z8
B3042 Z7
Output
Elect.1)
kWel.
175
200
350
Therm.2)
kBTU/hr
474
512
816
Exhaust3) Low Temp.
kBTU/hr (°F)kBTU/hr (°F)
321 (356) - - 509 (356) 44 (122)
772 (356) - - -
1) Rated power at nominal voltage, power factor = 1,0 and nominal frequency
2) Heat output from engine cooling with tolerance of ± 8%
3) Heat output from exhaust (exhaust cooling to 356°F) with tolerance of ± 8%
4) Performance data in accordance with ISO 3046/I-2002 with tolerance of 5%
5) Referenced methane number
Project specific data on request:
- different alternator voltage
- different flow-/return-temperatures, hot cooling, methane number, installation conditions etc.
- Container
Energy
input4)
kBTU/hr
1676
1909
3248
Efficiency
Electr.
nel. (%)
35.6
35.7
36.8
Total
ntot (%)
83.0
88.7
85.7
Methane
number5)
≥ 120
≥ 120
≥ 120
DS
EMA 1
M12*1.5
H
DRAWINGS AND DIMENSIONS
SS
93.25114-0067
93.25114-0067
TP65-230/2/50Hz
L
W
B
Note: This drawing is provided for reference only and should not be used for planning installation.
Genset Type
MTU 6R400 GS (L8)
MTU 6R400 GS (Z8)
MTU 12V400 GS (Z7)
Dimensions Genset (L x W x H)
---
133 x 69 x 83 in
155 x 67 x 84 in
Cogeneration module (L x W x H)
145 x 74 x 85 in
145 x 74 x 85 in
150 x 72 x 89 in
3066
Configuration
No. of cylinders
Bore/Stroke
Cyl. displacement
Rated speed
in-line
6
130/155 mm (5.12/6.10 in)
2.06 lit. (126 cu in)
1800 rpm
3042
Configuration
No. of cylinders
Bore/Stroke
Cyl. displacement
Rated speed
90°V
12
130/142 mm (5.12/5.59 in)
1.88 lit. (115 cu in)
1800 rpm
DESIGN AND EQUIPMENT (EXTRACT)
// Sliding gear starter 24V
// Gas supply with electronically controlled gas metering valve
// Electronic high-voltage capacitor ignition system with one ignition coil
per cylinder
// Electronic speed governor for speed and power output control with
automatic knocking control
Any specifications, descriptions, values, data or other information related to dimensions, power or other technical performance criteria of the goods as provided in
this general productinformation are to be understood as non-binding and may be subject to further changes such as but not limited to technical evolution at any time.
Version: 01.08.2014, materials and specifications subject to change without notice due to technical advances.
MTU Onsite Energy
A Rolls-Royce Power Systems Brand
www.mtuonsiteenergy.com
Subject to change. | 3236761 | Edition 02/14 | ENC 2014-08 | Printed in Germany on chlorine-free bleached papaer.
ENGINE DATA