PDF Data Sheet Rev. B

3-Channel, Low Noise, Low Power, 16-/24-Bit
∑-Δ ADC with On-Chip In-Amp and Reference
AD7792/AD7793
Up to 23 bits effective resolution
RMS noise
40 nV @ 4.17 Hz
85 nV @ 16.7 Hz
Current: 400 μA typical
Power-down: 1 μA maximum
Low noise programmable gain instrumentation amp
Band gap reference with 4 ppm/°C drift typical
Update rate: 4.17 Hz to 470 Hz
3 differential inputs
Internal clock oscillator
Simultaneous 50 Hz/60 Hz rejection
Programmable current sources
On-chip bias voltage generator
Burnout currents
Power supply: 2.7 V to 5.25 V
–40°C to +105°C temperature range
Independent interface power supply
16-lead TSSOP package
Interface
3-wire serial
SPI®, QSPI™, MICROWIRE™, and DSP compatible
Schmitt trigger on SCLK
APPLICATIONS
Thermocouple measurements
RTD measurements
Thermistor measurements
Gas analysis
Industrial process control
Instrumentation
Portable instrumentation
Blood analysis
Smart transmitters
Liquid/gas chromatography
6-digit DVM
FUNCTIONAL BLOCK DIAGRAM
GND
AVDD
REFIN(+)/AIN3(+) REFIN(–)/AIN3(–)
VBIAS
BAND GAP
REFERENCE
GND
AVDD
AIN1(+)
AIN1(–)
AIN2(+)
AIN2(–)
MUX
BUF
Σ-Δ
ADC
IN-AMP
SERIAL
INTERFACE
AND
CONTROL
LOGIC
AVDD GND
IOUT1
INTERNAL
CLOCK
IOUT2
CLK
AD7792: 16-BIT
AD7793: 24-BIT
DOUT/RDY
DIN
SCLK
CS
DVDD
04855-001
FEATURES
Figure 1.
GENERAL DESCRIPTION
The AD7792/AD7793 are low power, low noise, complete
analog front ends for high precision measurement applications.
The AD7792/AD7793 contain a low noise 16-/24-bit ∑-Δ ADC
with three differential analog inputs. The on-chip, low noise
instrumentation amplifier means that signals of small amplitude can be interfaced directly to the ADC. With a gain
setting of 64, the rms noise is 40 nV when the update rate
equals 4.17 Hz.
The devices contain a precision low noise, low drift internal
band gap reference and can accept an external differential
reference. Other on-chip features include programmable
excitation current sources, burnout currents, and a bias voltage
generator. The bias voltage generator sets the common-mode
voltage of a channel to AVDD/2.
The devices can be operated with either the internal clock or an
external clock. The output data rate from the parts is softwareprogrammable and can be varied from 4.17 Hz to 470 Hz.
The parts operate with a power supply from 2.7 V to 5.25 V.
They consume a current of 400 μA typical and are housed in a
16-lead TSSOP package.
Rev. B
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113 ©2004–2007 Analog Devices, Inc. All rights reserved.
AD7792/AD7793
TABLE OF CONTENTS
Features .............................................................................................. 1
Offset Register ............................................................................ 19
Applications....................................................................................... 1
Full-Scale Register...................................................................... 19
Functional Block Diagram .............................................................. 1
ADC Circuit Information.............................................................. 20
General Description ......................................................................... 1
Overview ..................................................................................... 20
Revision History ............................................................................... 2
Digital Interface.......................................................................... 21
Specifications..................................................................................... 3
Circuit Description......................................................................... 24
Timing Characteristics..................................................................... 6
Analog Input Channel ............................................................... 24
Timing Diagrams.......................................................................... 7
Instrumentation Amplifier........................................................ 24
Absolute Maximum Ratings............................................................ 8
Bipolar/Unipolar Configuration .............................................. 24
ESD Caution.................................................................................. 8
Data Output Coding .................................................................. 24
Pin Configuration and Function Descriptions............................. 9
Burnout Currents ....................................................................... 25
Output Noise and Resolution Specifications .............................. 11
Excitation Currents .................................................................... 25
External Reference...................................................................... 11
Bias Voltage Generator .............................................................. 25
Internal Reference ...................................................................... 12
Reference ..................................................................................... 25
Typical Performance Characteristics ........................................... 13
Reset ............................................................................................. 25
On-Chip Registers .......................................................................... 14
AVDD Monitor ............................................................................. 26
Communications Register......................................................... 14
Calibration................................................................................... 26
Status Register ............................................................................. 15
Grounding and Layout .............................................................. 26
Mode Register ............................................................................. 15
Applications Information .............................................................. 28
Configuration Register .............................................................. 17
Temperature Measurement using a Thermocouple............... 28
Data Register ............................................................................... 18
Temperature Measurement using an RTD.............................. 29
ID Register................................................................................... 18
Outline Dimensions ....................................................................... 30
IO Register................................................................................... 18
Ordering Guide .......................................................................... 30
REVISION HISTORY
3/07—Rev. A to Rev. B
Updated Format..................................................................Universal
Change to Functional Block Diagram ........................................... 1
Changes to Specifications Section.................................................. 3
Changes to Specifications Endnote 1............................................. 5
Changes to Table 5, Table 6, and Table 7 ..................................... 11
Changes to Table 8, Table 9, and Table 10 ................................... 12
Changes to Table 16........................................................................ 16
Changes to Overview Section ....................................................... 20
Renamed Applications Section to Applications Information... 29
Changes to Ordering Guide .......................................................... 30
4/05—Rev. 0 to Rev. A
Changes to Absolute Maximum Ratings........................................8
Changes to Figure 17.......................................................................22
Changes to Data Output Coding Section.....................................24
Changes to Calibration Section .....................................................26
Changes to Ordering Guide ...........................................................30
10/04—Revision 0: Initial Version
Rev. B | Page 2 of 32
AD7792/AD7793
SPECIFICATIONS
AVDD = 2.7 V to 5.25 V; DVDD = 2.7 V to 5.25 V; GND = 0 V; all specifications TMIN to TMAX, unless otherwise noted.
Table 1.
Parameter
ADC CHANNEL
Output Update Rate
No Missing Codes 2
Resolution
Output Noise and Update Rates
Integral Nonlinearity
Offset Error 3
Offset Error Drift vs. Temperature 4
Full-Scale Error3, 5
Gain Drift vs. Temperature4
Power Supply Rejection
ANALOG INPUTS
Differential Input Voltage Ranges
Absolute AIN Voltage Limits2
Unbuffered Mode
Buffered Mode
In-Amp Active
Common-Mode Voltage, VCM
Analog Input Current
Buffered Mode or In-Amp Active
Average Input Current2
Average Input Current Drift
Unbuffered Mode
Average Input Current
Average Input Current Drift
Normal Mode Rejection2
Internal Clock
@ 50 Hz, 60 Hz
@ 50 Hz
@ 60 Hz
External Clock
@ 50 Hz, 60 Hz
@ 50 Hz
@ 60 Hz
Common-Mode Rejection
@ DC
@ 50 Hz, 60 Hz2
@ 50 Hz, 60 Hz2
AD7792B/AD7793B 1
Unit
4.17 to 470
24
16
Hz nom
Bits min
Bits min
±15
±1
±10
±10
±1
±3
100
ppm of FSR max
μV typ
nV/°C typ
μV typ
ppm/°C typ
ppm/°C typ
dB min
±VREF/Gain
V nom
VREF = REFIN(+) − REFIN(−) or internal reference,
gain = 1 to 128
GND – 30 mV
AVDD + 30 mV
GND + 100 mV
AVDD – 100 mV
GND + 300 mV
AVDD – 1.1
0.5
V min
V max
V min
V max
V min
V max
V min
Gain = 1 or 2
±1
±250
±2
nA max
pA max
pA/°C typ
±400
±50
nA/V typ
pA/V/°C typ
65
80
90
dB min
dB min
dB min
80 dB typ, 50 ± 1 Hz, 60 ± 1 Hz, FS[3:0] = 1010 6
90 dB typ, 50 ± 1 Hz, FS[3:0] = 10016
100 dB typ, 60 ± 1 Hz, FS[3:0] = 10006
80
94
90
dB min
dB min
dB min
90 dB typ, 50 ± 1 Hz, 60 ± 1 Hz, FS[3:0] = 10106
100 dB typ, 50 ± 1 Hz, FS[3:0] = 10016
100 dB typ, 60 ± 1 Hz, FS[3:0] = 10006
100
100
100
dB min
dB min
dB min
AIN = 1 V/gain, gain ≥ 4
50 ± 1 Hz, 60 ± 1 Hz, FS[3:0] = 10106
50 ± 1 Hz (FS[3:0] = 1001)6, 60 ± 1 Hz
(FS[3:0] = 1000)6
Rev. B | Page 3 of 32
Test Conditions/Comments
fADC < 242 Hz, AD7793
AD7792
See Output Noise and Resolution Specifications
See Output Noise and Resolution Specifications
Gain = 1 to 16, external reference
Gain = 32 to 128, external reference
AIN = 1 V/gain, gain ≥ 4, external reference
Gain = 1 or 2
Gain = 4 to 128
VCM = (AIN(+) + AIN(−))/2, gain = 4 to 128
Gain = 1 or 2, update rate < 100 Hz
Gain = 4 to 128, update rate < 100 Hz
Gain = 1 or 2.
Input current varies with input voltage
AD7792/AD7793
Parameter
REFERENCE
Internal Reference
Internal Reference Initial Accuracy
Internal Reference Drift2
Power Supply Rejection
External Reference
External REFIN Voltage
Reference Voltage Range2
Absolute REFIN Voltage Limits2
Average Reference Input Current
Average Reference Input Current
Drift
Normal Mode Rejection
Common-Mode Rejection
EXCITATION CURRENT SOURCES
(IEXC1 and IEXC2)
Output Current
Initial Tolerance at 25°C
Drift
Current Matching
Drift Matching
Line Regulation (VDD)
Load Regulation
Output Compliance
TEMPERATURE SENSOR
Accuracy
Sensitivity
BIAS VOLTAGE GENERATOR
VBIAS
VBIAS Generator Start-Up Time
INTERNAL/EXTERNAL CLOCK
Internal Clock
Frequency2
Duty Cycle
External Clock
Frequency
Duty Cycle
AD7792B/AD7793B 1
Unit
Test Conditions/Comments
1.17 ± 0.01%
4
15
85
V min/max
ppm/°C typ
ppm/°C max
dB typ
AVDD = 4 V, TA = 25°C
2.5
0.1
AVDD
V nom
V min
V max
REFIN = REFIN(+) − REFIN(−)
GND − 30 mV
AVDD + 30 mV
400
±0.03
V min
V max
nA/V typ
nA/V/°C typ
Same as for analog inputs
100
dB typ
10/210/1000
±5
200
±0.5
50
2
0.2
AVDD − 0.65
AVDD − 1.1
GND − 30 mV
μA nom
% typ
ppm/°C typ
% typ
ppm/°C typ
%/V typ
%/V typ
V max
V max
V min
±2
0.81
°C typ
mV/°C typ
Applies if user calibrates the temperature
sensor
AVDD/2
See Figure 10
V nom
ms/nF typ
Dependent on the capacitance on the AIN pin
64 ± 3%
50:50
kHz min/max
% typ
64
kHz nom
45:55 to 55:45
% typ
0.8
0.4
2.0
V max
V max
V min
When VREF = AVDD, the differential input must be
limited to 0.9 × VREF /gain if the in-amp is active
Matching between IEXC1 and IEXC2; VOUT = 0 V
AVDD = 5 V ± 5%
10 μA or 210 μA currents selected
1 mA currents selected
A 128 kHz external clock can be used if the
divide-by-2 function is used
(Bit CLK1 = CLK0 = 1)
Applies for external 64 kHz clock; a 128 kHz
clock can have a less stringent duty cycle
LOGIC INPUTS
CS2
VINL, Input Low Voltage
VINH, Input High Voltage
Rev. B | Page 4 of 32
DVDD = 5 V
DVDD = 3 V
DVDD = 3 V or 5 V
AD7792/AD7793
Parameter
SCLK, CLK, and DIN (SchmittTriggered Input)2
VT(+)
VT(–)
VT(+) − VT(−)
VT(+)
VT(–)
VT(+) − VT(−)
Input Currents
Input Capacitance
LOGIC OUTPUTS (INCLUDING CLK)
VOH, Output High Voltage2
VOL, Output Low Voltage2
VOH, Output High Voltage2
VOL, Output Low Voltage2
Floating-State Leakage Current
Floating-State Output Capacitance
Data Output Coding
SYSTEM CALIBRATION2
Full-Scale Calibration Limit
Zero-Scale Calibration Limit
Input Span
POWER REQUIREMENTS 7
Power Supply Voltage
AVDD to GND
DVDD to GND
Power Supply Currents
IDD Current
IDD (Power-Down Mode)
AD7792B/AD7793B 1
Unit
Test Conditions/Comments
1.4/2
0.8/1.7
0.1/0.17
0.9/2
0.4/1.35
0.06/0.13
V min/V max
V min/V max
V min/V max
V min/V max
V min/V max
V min/V max
DVDD = 5 V
DVDD = 5 V
DVDD = 5 V
DVDD = 3 V
DVDD = 3 V
DVDD = 3 V
±10
10
μA max
pF typ
VIN = DVDD or GND
All digital inputs
DVDD − 0.6
0.4
4
0.4
V min
V max
V min
V max
DVDD = 3 V, ISOURCE = 100 μA
DVDD = 3 V, ISINK = 100 μA
DVDD = 5 V, ISOURCE = 200 μA
DVDD = 5 V, ISINK = 1.6 mA (DOUT/RDY)/800 μA
(CLK)
±10
10
Offset binary
μA max
pF typ
+1.05 × FS
−1.05 × FS
0.8 × FS
2.1 × FS
V max
V min
V min
V max
2.7/5.25
2.7/5.25
V min/max
V min/max
140
μA max
185
μA max
400
μA max
500
μA max
1
μA max
1
110 μA typ @ AVDD = 3 V, 125 μA typ @ AVDD = 5 V,
unbuffered mode, external reference
130 μA typ @ AVDD = 3 V, 165 μA typ @ AVDD = 5 V,
buffered mode, gain = 1 or 2, external reference
300 μA typ @ AVDD = 3 V, 350 μA typ @ AVDD = 5 V,
gain = 4 to 128, external reference
400 μA typ @ AVDD = 3 V, 450 μA typ @ AVDD = 5 V,
gain = 4 to 128, internal reference
Temperature range is –40°C to +105°C. At the 19.6 Hz and 39.2 Hz update rates, the INL, power supply rejection (PSR), common-mode rejection (CMR), and normal
mode rejection (NMR) do not meet the data sheet specification if the voltage on the AIN(+) or AIN(−) pins exceed AVDD − 16 V typically. When this voltage is exceeded,
the INL, for example, is reduced to 18 ppm of FS typically while the PSR is reduced to 69 dB typically. Therefore, for guaranteed performance at these update rates, the
absolute voltage on the analog input pins needs to be below AVDD − 1.6 V.
2
Specification is not production tested, but is supported by characterization data at initial product release.
3
Following a calibration, this error is in the order of the noise for the programmed gain and update rate selected.
4
Recalibration at any temperature removes these errors.
5
Full-scale error applies to both positive and negative full-scale and applies at the factory calibration conditions (AVDD = 4 V, gain = 1, TA = 25°C).
6
FS[3:0] are the four bits used in the mode register to select the output word rate.
7
Digital inputs equal to DVDD or GND with excitation currents and bias voltage generator disabled.
Rev. B | Page 5 of 32
AD7792/AD7793
TIMING CHARACTERISTICS
AVDD = 2.7 V to 5.25 V, DVDD = 2.7 V to 5.25 V, GND = 0 V, Input Logic 0 = 0 V, Input Logic 1 = DVDD, unless otherwise noted.
Table 2.
Parameter 1, 2
t3
t4
Read Operation
t1
t2 3
t5 5, 6
t6
t7
Write Operation
t8
t9
t10
t11
Limit at TMIN, TMAX (B Version)
100
100
Unit
ns min
ns min
Conditions/Comments
SCLK high pulse width
SCLK low pulse width
0
60
80
0
60
80
10
80
0
10
ns min
ns max
ns max
ns min
ns max
ns max
ns min
ns max
ns min
ns min
CS falling edge to DOUT/RDY active time
DVDD = 4.75 V to 5.25 V
DVDD = 2.7 V to 3.6 V
SCLK active edge to data valid delay 4
DVDD = 4.75 V to 5.25 V
DVDD = 2.7 V to 3.6 V
Bus relinquish time after CS inactive edge
SCLK inactive edge to CS inactive edge
SCLK inactive edge to DOUT/RDY high
0
30
25
0
ns min
ns min
ns min
ns min
CS falling edge to SCLK active edge setup time4
Data valid to SCLK edge setup time
Data valid to SCLK edge hold time
CS rising edge to SCLK edge hold time
1
Sample tested during initial release to ensure compliance. All input signals are specified with tR = tF = 5 ns (10% to 90% of DVDD) and timed from a voltage level of 1.6 V.
See Figure 3 and Figure 4.
3
These numbers are measured with the load circuit shown in Figure 2 and defined as the time required for the output to cross the VOL or VOH limits.
4
SCLK active edge is falling edge of SCLK.
5
These numbers are derived from the measured time taken by the data output to change 0.5 V when loaded with the circuit shown in Figure 2. The measured number
is then extrapolated back to remove the effects of charging or discharging the 50 pF capacitor. This means that the times quoted in the timing characteristics are the
true bus relinquish times of the part and, as such, are independent of external bus loading capacitances.
6 RDY
returns high after a read of the ADC. In single conversion mode and continuous conversion mode, the same data can be read again, if required, while RDY is high,
although care should be taken to ensure that subsequent reads do not occur close to the next output update. In continuous read mode, the digital word can be read
only once.
2
ISINK (1.6mA WITH DVDD = 5V,
100µA WITH DVDD = 3V)
TO
OUTPUT
PIN
1.6V
ISOURCE (200µA WITH DVDD = 5V,
100µA WITH DVDD = 3V)
Figure 2. Load Circuit for Timing Characterization
Rev. B | Page 6 of 32
04855-002
50pF
AD7792/AD7793
TIMING DIAGRAMS
CS (I)
t6
t1
t5
MSB
DOUT/RDY (O)
LSB
t7
t2
t3
04855-003
SCLK (I)
t4
NOTES
1. I = INPUT, O = OUTPUT
Figure 3. Read Cycle Timing Diagram
CS (I)
t11
t8
SCLK (I)
t9
t10
MSB
LSB
NOTES
1. I = INPUT, O = OUTPUT
Figure 4. Write Cycle Timing Diagram
Rev. B | Page 7 of 32
04855-004
DIN (I)
AD7792/AD7793
ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
Table 3.
Parameter
AVDD to GND
DVDD to GND
Analog Input Voltage to GND
Reference Input Voltage to GND
Digital Input Voltage to GND
Digital Output Voltage to GND
AIN/Digital Input Current
Operating Temperature Range
Storage Temperature Range
Maximum Junction Temperature
TSSOP
θJA Thermal Impedance
θJC Thermal Impedance
Lead Temperature, Soldering
Vapor Phase (60 sec)
Infrared (15 sec)
Ratings
−0.3 V to +7 V
−0.3 V to +7 V
−0.3 V to AVDD + 0.3 V
−0.3 V to AVDD + 0.3 V
−0.3 V to DVDD + 0.3 V
−0.3 V to DVDD + 0.3 V
10 mA
−40°C to +105°C
−65°C to +150°C
150°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those listed in the operational sections
of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION
128°C/W
14°C/W
215°C
220°C
Rev. B | Page 8 of 32
AD7792/AD7793
SCLK 1
16
DIN
CLK 2
15
DOUT/RDY
CS 3
14
DVDD
IOUT1 4
AIN1(+)
5
AD7792/
AD7793
TOP VIEW
(Not to Scale)
13
AVDD
12
GND
IOUT2
AIN1(–)
6
11
AIN2(+)
7
10
REFIN(–)/AIN3(–)
AIN2(–)
8
9
REFIN(+)/AIN3(+)
04855-005
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
Figure 5. Pin Configuration
Table 4. Pin Function Descriptions
Pin No.
1
Mnemonic
SCLK
2
CLK
3
CS
4
IOUT1
5
6
7
8
9
AIN1(+)
AIN1(−)
AIN2(+)
AIN2(−)
REFIN(+)/AIN3(+)
10
REFIN(−)/AIN3(−)
11
IOUT2
12
13
14
GND
AVDD
DVDD
Description
Serial Clock Input. This serial clock input is for data transfers to and from the ADC. The SCLK has a Schmitttriggered input, making the interface suitable for opto-isolated applications. The serial clock can be
continuous with all data transmitted in a continuous train of pulses. Alternatively, it can be a noncontinuous
clock with the information being transmitted to or from the ADC in smaller batches of data.
Clock In/Clock Out. The internal clock can be made available at this pin. Alternatively, the internal clock can
be disabled, and the ADC can be driven by an external clock. This allows several ADCs to be driven from a
common clock, allowing simultaneous conversions to be performed.
Chip Select Input. This is an active low logic input used to select the ADC. CS can be used to select the ADC
in systems with more than one device on the serial bus or as a frame synchronization signal in communicating
with the device. CS can be hardwired low, allowing the ADC to operate in 3-wire mode with SCLK, DIN, and
DOUT used to interface with the device.
Output of Internal Excitation Current Source. The internal excitation current source can be made available at
this pin. The excitation current source is programmable so that the current can be 10 μA, 210 μA, or 1 mA.
Either IEXC1 or IEXC2 can be switched to this output.
Analog Input. AIN1(+) is the positive terminal of the differential analog input pair AIN1(+)/AIN1(−).
Analog Input. AIN1(−) is the negative terminal of the differential analog input pair AIN1(+)/AIN1(−).
Analog Input. AIN2(+) is the positive terminal of the differential analog input pair AIN2(+)/AIN2(−).
Analog Input. AIN2(−) is the negative terminal of the differential analog input pair AIN2(+)/AIN2(−).
Positive Reference Input/Analog Input. An external reference can be applied between REFIN(+) and
REFIN(−). REFIN(+) can lie anywhere between AVDD and GND + 0.1 V. The nominal reference voltage
REFIN(+) − REFIN(−) is 2.5 V, but the part functions with a reference from 0.1 V to AVDD. Alternatively, this pin
can function as AIN3(+) where AIN3(+) is the positive terminal of the differential analog input pair
AIN3(+)/AIN3(−).
Negative Reference Input/Analog Input. REFIN(−) is the negative reference input for REFIN. This reference
input can lie anywhere between GND and AVDD − 0.1 V. This pin also functions as AIN3(−), which is the
negative terminal of the differential analog input pair AIN3(+)/AIN3(−).
Output of Internal Excitation Current Source. The internal excitation current source can be made available at
this pin. The excitation current source is programmable so that the current can be 10 μA, 210 μA, or 1 mA.
Either IEXC1 or IEXC2 can be switched to this output.
Ground Reference Point.
Supply Voltage, 2.7 V to 5.25 V.
Digital Interface Supply Voltage. The logic levels for the serial interface pins are related to this supply, which
is between 2.7 V and 5.25 V. The DVDD voltage is independent of the voltage on AVDD; therefore, AVDD can
equal 5 V with DVDD at 3 V or vice versa.
Rev. B | Page 9 of 32
AD7792/AD7793
Pin No.
15
Mnemonic
DOUT/RDY
16
DIN
Description
Serial Data Output/Data Ready Output. DOUT/RDY serves a dual purpose. It functions as a serial data output
pin to access the output shift register of the ADC. The output shift register can contain data from any of the
on-chip data or control registers. In addition, DOUT/RDY operates as a data ready pin, going low to indicate
the completion of a conversion. If the data is not read after the conversion, the pin goes high before the
next update occurs.
The DOUT/RDY falling edge can be used as an interrupt to a processor, indicating that valid data is available.
With an external serial clock, the data can be read using the DOUT/RDY pin. With CS low, the data/control
word information is placed on the DOUT/RDY pin on the SCLK falling edge and is valid on the SCLK
rising edge.
Serial Data Input. This serial data input is to the input shift register on the ADC. Data in this shift register is
transferred to the control registers within the ADC; the register selection bits of the communications
register identify the appropriate register.
Rev. B | Page 10 of 32
AD7792/AD7793
OUTPUT NOISE AND RESOLUTION SPECIFICATIONS
EXTERNAL REFERENCE
Table 5 shows the output rms noise of the AD7792/AD7793 for
some of the update rates and gain settings. The numbers given
are for the bipolar input range with an external 2.5 V reference.
These numbers are typical and are generated with a differential
input voltage of 0 V. Table 6 and Table 7 show the effective
resolution, with the output peak-to-peak (p-p) resolution
shown in parentheses for the AD7793 and AD7792, respectively.
It is important to note that the effective resolution is calculated
using the rms noise, while the p-p resolution is based on the p-p
noise. The p-p resolution represents the resolution for which
there is no code flicker. These numbers are typical and are
rounded to the nearest LSB.
Table 5. Output RMS Noise (μV) vs. Gain and Output Update Rate for the AD7792 and AD7793 Using an External 2.5 V Reference
Update Rate (Hz)
4.17
8.33
16.7
33.2
62
123
242
470
Gain of 1
0.64
1.04
1.55
2.3
2.95
4.89
11.76
11.33
Gain of 2
0.6
0.96
1.45
2.13
2.85
4.74
9.5
9.44
Gain of 4
0.29
0.38
0.54
0.74
0.92
1.49
4.02
3.07
Gain of 8
0.22
0.26
0.36
0.5
0.58
1
1.96
1.79
Gain of 16
0.1
0.13
0.18
0.23
0.29
0.48
0.88
0.99
Gain of 32
0.065
0.078
0.11
0.17
0.2
0.32
0.45
0.63
Gain of 64
0.039
0.057
0.087
0.124
0.153
0.265
0.379
0.568
Gain of 128
0.041
0.055
0.086
0.118
0.144
0.283
0.397
0.593
Table 6. Typical Resolution (Bits) vs. Gain and Output Update Rate for the AD7793 Using an External 2.5 V Reference
Update Rate (Hz)
4.17
8.33
16.7
33.2
62
123
242
470
Gain of 1
23 (20.5)
22 (19.5)
21.5 (19)
21 (18.5)
20.5 (18)
20 (17.5)
18.5 (16)
18.5 (16)
Gain of 2
22 (19.5)
21.5 (19)
20.5 (18)
20 (17.5)
19.5 (17)
19 (16.5)
18 (15.5)
18 (15.5)
Gain of 4
22 (19.5)
21.5 (19)
21 (18.5)
20.5 (18)
20.5 (18)
19.5 (17)
18 (15.5)
18.5 (16)
Gain of 8
21.5 (19)
21 (18.5)
20.5 (18)
20 (17.5)
20 (17.5)
19 (16.5)
18 (15.5)
18.5 (16)
Gain of 16
21.5 (19)
21 (18.5)
20.5 (18)
20.5 (18)
20 (17.5)
19.5 (17)
18.5 (16)
18 (15.5)
Gain of 32
21 (18.5)
21 (18.5)
20.5 (18)
20 (17.5)
19.5 (17)
19 (16.5)
18.5 (16)
18 (15.5)
Gain of 64
21 (18.5)
20.5 (18)
20 (17.5)
19 (16.5)
19 (16.5)
18 (15.5)
17.5 (15)
17 (14.5)
Gain of 128
20 (17.5)
19.5 (17)
19 (16.5)
18.5 (16)
18 (15.5)
17 (14.5)
16.5 (14)
16 (13.5)
Table 7. Typical Resolution (Bits) vs. Gain and Output Update Rate for the AD7792 Using an External 2.5 V Reference
Update Rate (Hz)
4.17
8.33
16.7
33.2
62
123
242
470
Gain of 1
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
Gain of 2
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15.5)
16 (15.5)
Gain of 4
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15.5)
16 (16)
Gain of 8
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15.5)
16 (16)
Rev. B | Page 11 of 32
Gain of 16
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15.5)
Gain of 32
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15.5)
Gain of 64
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
165 (15.5)
16 (15)
16 (14.5)
Gain of 128
16 (16)
16 (16)
16 (16)
16 (16)
16 (15.5)
16 (14.5)
16 (14)
15.5 (13.5)
AD7792/AD7793
INTERNAL REFERENCE
Table 8 shows the output rms noise of the AD7792/AD7793 for
some of the update rates and gain settings. The numbers given
are for the bipolar input range with the internal 1.17 V
reference. These numbers are typical and are generated with a
differential input voltage of 0 V. Table 9 and Table 10 show the
effective resolution, with the output peak-to-peak (p-p)
resolution given in parentheses for the AD7793 and AD7792,
respectively. It is important to note that the effective resolution
is calculated using the rms noise, while the p-p resolution is
calculated based on p-p noise. The p-p resolution represents the
resolution for which there is no code flicker. These numbers are
typical and are rounded to the nearest LSB.
Table 8. Output RMS Noise (μV) vs. Gain and Output Update Rate for the AD7792 and AD7793 Using the Internal Reference
Update Rate (Hz)
4.17
8.33
16.7
33.2
62
123
242
470
Gain of 1
0.81
1.18
1.96
2.99
3.6
5.83
11.22
12.46
Gain of 2
0.67
1.11
1.72
2.48
3.25
5.01
8.64
10.58
Gain of 4
0.32
0.41
0.55
0.83
1.03
1.69
2.69
4.58
Gain of 8
0.2
0.25
0.36
0.48
0.65
0.96
1.9
2
Gain of 16
0.13
0.16
0.25
0.33
0.46
0.67
1.04
1.27
Gain of 32
0.065
0.078
0.11
0.17
0.2
0.32
0.45
0.63
Gain of 64
0.04
0.058
0.088
0.13
0.15
0.25
0.35
0.50
Gain of 128
0.039
0.059
0.088
0.12
0.15
0.26
0.34
0.49
Table 9. Typical Resolution (Bits) vs. Gain and Output Update Rate for the AD7793 Using the Internal Reference
Update Rate (Hz)
4.17
8.33
16.7
33.2
62
123
242
470
Gain of 1
21.5 (19)
21 (18.5)
20 (17.5)
19.5 (17)
19.5 (17)
18.5 (16)
17.5 (15)
17.5 (15)
Gain of 2
20.5 (18)
20 (17.5)
19.5 (17)
19 (16.5)
18.5 (16)
18 (15.5)
17 (14.5)
17 (14.5)
Gain of 4
21 (18.5)
20.5 (18)
20 (17.5)
19.5 (17)
19 (16.5)
18.5 (16)
17.5 (15)
17 (14.5)
Gain of 8
20.5 (18)
20 (17.5)
19.5 (17)
19 (16.5)
19 (16.5)
18 (15.5)
17 (14.5)
17 (14.5)
Gain of 16
20 (17.5)
20 (17.5)
19 (16.5)
19 (16.5)
18.5 (16)
17.5 (15)
17 (14.5)
17 (14.5)
Gain of 32
20 (17.5)
20 (17.5)
19.5 (17)
18.5 (16)
18.5 (16)
18 (15.5)
17.5 (15)
17 (14.5)
Gain of 64
20 (17.5)
19 (16.5)
18.5 (16)
18 (15.5)
18 (15.5)
17 (14.5)
16.5 (14)
16 (13.5)
Gain of 128
19 (16.5)
18 (15.5)
17.5 (15)
17 (14.5)
17 (14.5)
16 (13.5)
15.5 (13)
15 (12.5)
Table 10. Typical Resolution (Bits) vs. Gain and Output Update Rate for the AD7792 Using the Internal Reference
Update Rate (Hz)
4.17
8.33
16.7
33.2
62
123
242
470
Gain of 1
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15)
16 (15)
Gain of 2
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15.5)
16 (14.5)
16 (14.5)
Gain of 4
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15)
16 (14.5)
Gain of 8
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15.5)
16 (14.5)
16 (14.5)
Rev. B | Page 12 of 32
Gain of 16
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15)
16 (14.5)
16 (14.5)
Gain of 32
16 (16)
16 (16)
16 (16)
16 (16)
16 (16)
16 (15.5)
16 (15)
16 (14.5)
Gain of 64
16 (16)
16 (16)
16 (16)
16 (15.5)
16 (15.5)
16 (14.5)
16 (14)
15.5 (13.5)
Gain of 128
16 (16)
16 (15.5)
16 (15)
16 (14.5)
16 (14.5)
15.5 (13.5)
15 (13)
14.5 (12.5)
AD7792/AD7793
TYPICAL PERFORMANCE CHARACTERISTICS
8388800
8388750
20
OCCURRENCE (%)
8388650
8388600
10
8388450
04855-006
8388500
0
200
400
600
800
0
1000
04855-009
8388550
–1.75 –1.05 –0.70 –0.35
0.35
0.70
1.05
1.40
1.75
Figure 9. Excitation Current Matching (1 mA) at Ambient Temperature
Figure 6. Typical Noise Plot (Internal Reference, Gain = 64,
Update Rate = 16.7 Hz) for AD7793
16
90
14
80
70
POWER-UP TIME (ms)
12
10
8
6
4
60
50
40
30
20
10
04855-007
2
0
8388482
8388520
8388560
8388600
8388640
8388680
0
8388720 8388750
CODE
04855-010
OCCURRENCE
0
MATCHING (%)
READING NUMBER
0
200
400
600
800
1000
LOAD CAPACITANCE (nF)
Figure 10. Bias Voltage Generator Power-Up Time vs. Load Capacitance
Figure 7. Noise Distribution Histogram for AD7793
(Internal Reference, Gain = 64, Update Rate = 16.7 Hz)
3.0
VDD = 5V
UPDATE RATE = 16.6Hz
TA = 25°C
2.5
RMS NOISE (µV)
20
10
2.0
1.5
1.0
0
–2.0
–1.2
–0.8
–0.4
0
0.4
0.8
1.2
1.6
2.0
MATCHING (%)
0
04855-011
0.5
04855-008
OCCURRENCE (%)
CODE READ
8388700
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
REFERENCE VOLTAGE (V)
Figure 8. Excitation Current Matching (210 μA) at Ambient
Temperature
Figure 11. RMS Noise vs. Reference Voltage (Gain = 1)
Rev. B | Page 13 of 32
5.0
AD7792/AD7793
ON-CHIP REGISTERS
The ADC is controlled and configured via a number of on-chip
registers, which are described on the following pages. In the
following descriptions, set implies a Logic 1 state and cleared
implies a Logic 0 state, unless otherwise stated.
COMMUNICATIONS REGISTER
RS2, RS1, RS0 = 0, 0, 0
The communications register is an 8-bit write-only register. All
communications to the part must start with a write operation to
the communications register. The data written to the
communications register determines whether the next
operation is a read or write operation, and to which register this
operation takes place. For read or write operations, once the
subsequent read or write operation to the selected register is
CR7
WEN(0)
CR6
R/W(0)
CR5
RS2(0)
CR4
RS1(0)
complete, the interface returns to where it expects a write
operation to the communications register. This is the default
state of the interface and, on power-up or after a reset, the ADC
is in this default state waiting for a write operation to the
communications register. In situations where the interface
sequence is lost, a write operation of at least 32 serial clock
cycles with DIN high returns the ADC to this default state by
resetting the entire part. Table 11 outlines the bit designations
for the communications register. CR0 through CR7 indicate the
bit location, CR denoting the bits are in the communications
register. CR7 denotes the first bit of the data stream. The
number in parentheses indicates the power-on/reset default
status of that bit.
CR3
RS0(0)
CR2
CREAD(0)
CR1
0(0)
CR0
0(0)
Table 11. Communications Register Bit Designations
Bit Location
CR7
Bit Name
WEN
CR6
R/W
CR5 to CR3
CR2
RS2 to
RS0
CREAD
CR1 to CR0
0
Description
Write Enable Bit. A 0 must be written to this bit so that the write to the communications register actually
occurs. If a 1 is the first bit written, the part does not clock on to subsequent bits in the register. It stays at this
bit location until a 0 is written to this bit. Once a 0 is written to the WEN bit, the next seven bits are loaded to
the communications register.
A 0 in this bit location indicates that the next operation is a write to a specified register. A 1 in this position
indicates that the next operation is a read from the designated register.
Register Address Bits. These address bits are used to select which of the ADC’s registers are being selected
during this serial interface communication. See Table 12.
Continuous Read of the Data Register. When this bit is set to 1 (and the data register is selected), the serial
interface is configured so that the data register can be continuously read. For example, the contents of the
data register are placed on the DOUT pin automatically when the SCLK pulses are applied after the RDY pin
goes low to indicate that a conversion is complete. The communications register does not have to be written
to for data reads. To enable continuous read mode, the instruction 01011100 must be written to the
communications register. To exit the continuous read mode, the instruction 01011000 must be written to the
communications register while the RDY pin is low. While in continuous read mode, the ADC monitors activity
on the DIN line so that it can receive the instruction to exit continuous read mode. Additionally, a reset occurs
if 32 consecutive 1s are seen on DIN. Therefore, DIN should be held low in continuous read mode until an
instruction is to be written to the device.
These bits must be programmed to Logic 0 for correct operation.
Table 12. Register Selection
RS2
0
0
0
0
0
1
1
1
1
RS1
0
0
0
1
1
0
0
1
1
RS0
0
0
1
0
1
0
1
0
1
Register
Communications Register During a Write Operation
Status Register During a Read Operation
Mode Register
Configuration Register
Data Register
ID Register
IO Register
Offset Register
Full-Scale Register
Rev. B | Page 14 of 32
Register Size
8-bit
8-bit
16-bit
16-bit
16-/24-bit
8-bit
8-bit
16-bit (AD7792)/24-bit (AD7793)
16-bit (AD7792)/24-bit (AD7793)
AD7792/AD7793
STATUS REGISTER
RS2, RS1, RS0 = 0, 0, 0; Power-On/Reset = 0x80 (AD7792)/0x88 (AD7793)
The status register is an 8-bit read-only register. To access the ADC status register, the user must write to the communications register,
select the next operation to be a read, and load Bit RS2, Bit RS1, and Bit RS0 with 0. Table 13 outlines the bit designations for the status
register. SR0 through SR7 indicate the bit locations, and SR denotes that the bits are in the status register. SR7 denotes the first bit of the
data stream. The number in parentheses indicates the power-on/reset default status of that bit.
SR7
RDY(1)
SR6
ERR(0)
SR5
0(0)
SR4
0(0)
SR3
0/1
SR2
CH2(0)
SR1
CH1(0)
SR0
CH0(0)
Table 13. Status Register Bit Designations
Bit Location
SR7
Bit Name
RDY
SR6
ERR
SR5 to SR4
SR3
SR2 to SR0
0
0/1
CH2 to CH0
Description
Ready Bit for ADC. Cleared when data is written to the ADC data register. The RDY bit is set automatically
after the ADC data register has been read or a period of time before the data register is updated with a new
conversion result to indicate to the user not to read the conversion data. It is also set when the part is
placed in power-down mode. The end of a conversion is indicated by the DOUT/RDY pin also. This pin can
be used as an alternative to the status register for monitoring the ADC for conversion data.
ADC Error Bit. This bit is written to at the same time as the RDY bit. Set to indicate that the result written to
the ADC data register has been clamped to all 0s or all 1s. Error sources include overrange and underrange.
Cleared by a write operation to start a conversion.
These bits are automatically cleared.
This bit is automatically cleared on the AD7792 and is automatically set on the AD7793.
These bits indicate which channel is being converted by the ADC.
MODE REGISTER
RS2, RS1, RS0 = 0, 0, 1; Power-On/Reset = 0x000A
The mode register is a 16-bit register from which data can be read or to which data can be written. This register is used to select the
operating mode, update rate, and clock source. Table 14 outlines the bit designations for the mode register. MR0 through MR15 indicate
the bit locations, MR denoting the bits are in the mode register. MR15 denotes the first bit of the data stream. The number in parentheses
indicates the power-on/reset default status of that bit. Any write to the setup register resets the modulator and filter and sets the RDY bit.
MR15
MD2(0)
MR7
CLK1(0)
MR14
MD1(0)
MR6
CLK0(0)
MR13
MD0(0)
MR5
0(0)
MR12
0(0)
MR4
0(0)
MR11
0(0)
MR3
FS3(1)
MR10
0(0)
MR2
FS2(0)
MR9
0(0)
MR1
FS1(1)
MR8
0(0)
MR0
FS0(0)
Table 14. Mode Register Bit Designations
Bit Location
MR15 to
MR13
MR12 to MR8
MR7 to MR6
Bit Name
MD2 to
MD0
0
CLK1 to
CLK0
MR5 to MR4
MR3 to MR0
0
FS3 to FS0
Description
Mode Select Bits. These bits select the operational mode of the AD7792/AD7793 (see Table 15).
These bits must be programmed with a Logic 0 for correct operation.
These bits are used to select the clock source for the AD7792/AD7793. Either an on-chip 64 kHz clock can be
used, or an external clock can be used. The ability to override using an external clock allows several
AD7792/AD7793 devices to be synchronized. In addition, 50 Hz/60 Hz is improved when an accurate external
clock drives the AD7792/AD7793.
CLK1
CLK0
ADC Clock Source
0
0
Internal 64 kHz Clock. Internal clock is not available at the CLK pin.
0
1
Internal 64 kHz Clock. This clock is made available at the CLK pin.
1
0
External 64 kHz Clock Used. An external clock gives better 50 Hz/60 Hz rejection. See
specifications for external clock.
1
1
External Clock Used. The external clock is divided by 2 within the AD7792/AD7793.
These bits must be programmed with a Logic 0 for correct operation.
Filter Update Rate Select Bits (see Table 16).
Rev. B | Page 15 of 32
AD7792/AD7793
Table 15. Operating Modes
MD2
0
MD1
0
MD0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
Mode
Continuous Conversion Mode (Default).
In continuous conversion mode, the ADC continuously performs conversions and places the result in the data
register. RDY goes low when a conversion is complete. The user can read these conversions by placing the device in
continuous read mode, whereby the conversions are automatically placed on the DOUT line when SCLK pulses are
applied. Alternatively, the user can instruct the ADC to output the conversion by writing to the communications
register. After power-on, a channel change, or a write to the mode, configuration, or IO registers, the first conversion
is available after a period of 2/fADC. Subsequent conversions are available at a frequency of fADC.
Single Conversion Mode.
When single conversion mode is selected, the ADC powers up and performs a single conversion. The oscillator
requires 1 ms to power up and settle. The ADC then performs the conversion, which takes a time of 2/fADC. The
conversion result is placed in the data register, RDY goes low, and the ADC returns to power-down mode. The
conversion remains in the data register, and RDY remains active low until the data is read or another conversion is
performed.
Idle Mode.
In idle mode, the ADC filter and modulator are held in a reset state, although the modulator clocks are still provided.
Power-Down Mode.
In power-down mode, all the AD7792/AD7793 circuitry is powered down, including the current sources, burnout
currents, bias voltage generator, and CLKOUT circuitry.
Internal Zero-Scale Calibration.
An internal short is automatically connected to the enabled channel. A calibration takes 2 conversion cycles to
complete. RDY goes high when the calibration is initiated and returns low when the calibration is complete. The
ADC is placed in idle mode following a calibration. The measured offset coefficient is placed in the offset register of
the selected channel.
Internal Full-Scale Calibration.
A full-scale input voltage is automatically connected to the selected analog input for this calibration.
When the gain equals 1, a calibration takes 2 conversion cycles to complete. For higher gains, 4 conversion cycles
are required to perform the full-scale calibration.
RDY goes high when the calibration is initiated and returns low when the calibration is complete. The ADC is placed
in idle mode following a calibration. The measured full-scale coefficient is placed in the full-scale register of the
selected channel.
Internal full-scale calibrations cannot be performed when the gain equals 128. With this gain setting, a system fullscale calibration can be performed.
A full-scale calibration is required each time the gain of a channel is changed to minimize the full-scale error.
System Zero-Scale Calibration.
User should connect the system zero-scale input to the channel input pins as selected by the CH2 to CH0 bits. A
system offset calibration takes 2 conversion cycles to complete. RDY goes high when the calibration is initiated and
returns low when the calibration is complete. The ADC is placed in idle mode following a calibration. The measured
offset coefficient is placed in the offset register of the selected channel.
System Full-Scale Calibration.
User should connect the system full-scale input to the channel input pins as selected by the CH2 to CH0 bits.
A calibration takes 2 conversion cycles to complete. RDY goes high when the calibration is initiated and returns low
when the calibration is complete. The ADC is placed in idle mode following a calibration. The measured full-scale
coefficient is placed in the full-scale register of the selected channel.
A full-scale calibration is required each time the gain of a channel is changed.
Table 16. Update Rates Available
FS3
0
0
0
0
0
0
0
0
1
FS2
0
0
0
0
1
1
1
1
0
FS1
0
0
1
1
0
0
1
1
0
FS0
0
1
0
1
0
1
0
1
0
fADC (Hz)
x
470
242
123
62
50
39
33.2
19.6
tSETTLE (ms)
x
4
8
16
32
40
48
60
101
Rejection @ 50 Hz/60 Hz (Internal Clock)
90 dB (60 Hz only)
Rev. B | Page 16 of 32
AD7792/AD7793
FS3
1
1
1
1
1
1
1
FS2
0
0
0
1
1
1
1
FS1
0
1
1
0
0
1
1
FS0
1
0
1
0
1
0
1
fADC (Hz)
16.7
16.7
12.5
10
8.33
6.25
4.17
tSETTLE (ms)
120
120
160
200
240
320
480
Rejection @ 50 Hz/60 Hz (Internal Clock)
80 dB (50 Hz only)
65 dB (50 Hz and 60 Hz)
66 dB (50 Hz and 60 Hz)
69 dB (50 Hz and 60 Hz)
70 dB (50 Hz and 60 Hz)
72 dB (50 Hz and 60 Hz)
74 dB (50 Hz and 60 Hz)
CONFIGURATION REGISTER
RS2, RS1, RS0 = 0, 1, 0; Power-On/Reset = 0x0710
The configuration register is a 16-bit register from which data can be read or to which data can be written. This register is used to configure the ADC for unipolar or bipolar mode, enable or disable the buffer, enable or disable the burnout currents, select the gain, and
select the analog input channel. Table 17 outlines the bit designations for the filter register. CON0 through CON15 indicate the bit
locations; CON denotes that the bits are in the configuration register. CON15 denotes the first bit of the data stream. The number in
parentheses indicates the power-on/reset default status of that bit.
CON15
VBIAS1(0)
CON14
VBIAS0(0)
CON13
BO(0)
CON12
U/B(0)
CON11
BOOST(0)
CON10
G2(1)
CON9
G1(1)
CON8
G0(1)
CON7
REFSEL(0)
CON6
0(0)
CON5
0(0)
CON4
BUF(1)
CON3
0(0)
CON2
CH2(0)
CON1
CH1(0)
CON0
CH0(0)
Table 17. Configuration Register Bit Designations
Bit Location
CON15 to
CON14
Bit Name
VBIAS1 to
VBIAS0
CON13
BO
CON12
U/B
CON11
BOOST
CON10 to
CON8
G2 to G0
Description
Bias Voltage Generator Enable. The negative terminal of the analog inputs can be biased up to AVDD/2. These
bits are used in conjunction with the boost bit.
VBIAS1
VBIAS0
Bias Voltage
0
0
Bias voltage generator disabled
0
1
Bias voltage connected to AIN1(−)
1
0
Bias voltage connected to AIN2(−)
1
1
Reserved
Burnout Current Enable Bit. When this bit is set to 1 by the user, the 100 nA current sources in the signal path
are enabled. When BO = 0, the burnout currents are disabled. The burnout currents can be enabled only
when the buffer or in-amp is active.
Unipolar/Bipolar Bit. Set by user to enable unipolar coding; that is, zero differential input results in 0x000000
output, and a full-scale differential input results in 0xFFFFFF output. Cleared by the user to enable bipolar
coding. Negative full-scale differential input results in an output code of 0x000000, zero differential input
results in an output code of 0x800000, and a positive full-scale differential input results in an output code of
0xFFFFFF.
This bit is used in conjunction with the VBIAS1 and VBIAS0 bits. When set, the current consumed by the bias
voltage generator is increased. This reduces its power-up time.
Gain Select Bits.
Written by the user to select the ADC input range as follows:
G2
G1
G0
Gain
ADC Input Range (2.5 V Reference)
0
0
0
1 (In-amp not used)
2.5 V
0
0
1
2 (In-amp not used)
1.25 V
0
1
0
4
625 mV
0
1
1
8
312.5 mV
1
0
0
16
156.2 mV
1
0
1
32
78.125 mV
1
1
0
64
39.06 mV
1
1
1
128
19.53 mV
Rev. B | Page 17 of 32
AD7792/AD7793
Bit Location
CON7
Bit Name
REFSEL
CON6 to
CON5
CON4
0
BUF
CON3
CON2 to
CON0
0
CH2 to
CH0
Description
Reference Select Bit. The reference source for the ADC is selected using this bit.
REFSEL
Reference Source
0
External Reference Applied between REFIN(+) and REFIN(–).
1
Internal Reference Selected.
These bits must be programmed with a Logic 0 for correct operation.
Configures the ADC for buffered or unbuffered mode of operation. If cleared, the ADC operates in unbuffered
mode, lowering the power consumption of the device. If set, the ADC operates in buffered mode, allowing the
user to place source impedances on the front end without contributing gain errors to the system. The buffer
can be disabled when the gain equals 1 or 2. For higher gains, the buffer is automatically enabled.
With the buffer disabled, the voltage on the analog input pins can be from 30 mV below GND to 30 mV above
AVDD. When the buffer is enabled, it requires some headroom, so the voltage on any input pin must be limited
to 100 mV within the power supply rails.
This bit must be programmed with a Logic 0 for correct operation.
Channel Select Bits. Written by the user to select the active analog input channel to the ADC.
CH2
0
0
0
0
1
1
1
1
CH1
0
0
1
1
0
0
1
1
CH0
0
1
0
1
0
1
0
1
Channel
AIN1(+) – AIN1(–)
AIN2(+) – AIN2(–)
AIN3(+) – AIN3(–)
AIN1(–) – AIN1(–)
Reserved
Reserved
Temp Sensor
AVDD Monitor
Calibration Pair
0
1
2
0
Automatically selects gain = 1 and internal reference
Automatically selects gain = 1/6 and 1.17 V
reference
DATA REGISTER
RS2, RS1, RS0 = 0, 1, 1; Power-On/Reset = 0x0000(00)
The conversion result from the ADC is stored in this data register. This is a read-only register. On completion of a read operation from
this register, the RDY bit/pin is set.
ID REGISTER
RS2, RS1, RS0 = 1, 0, 0; Power-On/Reset = 0xXA (AD7792)/0xXB (AD7793)
The identification number for the AD7792/AD7793 is stored in the ID register. This is a read-only register.
IO REGISTER
RS2, RS1, RS0 = 1, 0, 1; Power-On/Reset = 0x00
The IO register is an 8-bit register from which data can be read or to which data can be written. This register is used to enable and select
the value of the excitation currents. Table 18 outlines the bit designations for the IO register. IO0 through IO7 indicate the bit locations;
IO denotes that the bits are in the IO register. IO7 denotes the first bit of the data stream. The number in parentheses indicates the poweron/reset default status of that bit.
IO7
0(0)
IO6
0(0)
IO5
0(0)
IO4
0(0)
IO3
IEXCDIR1(0)
IO2
IEXCDIR0(0)
Rev. B | Page 18 of 32
IO1
IEXCEN1(0)
IO0
IEXCEN0(0)
AD7792/AD7793
Table 18. IO Register Bit Designations
Bit Location
IO7 to IO4
IO3 to IO2
Bit Name
0
IEXCDIR1 to
IEXCDIR0
Description
These bits must be programmed with a Logic 0 for correct operation.
Direction of current sources select bits.
IEXCDIR1
0
IO1 to IO0
IEXCEN1 to
IEXCEN0
IEXCDIR0
0
Current Source Direction
Current Source IEXC1 connected to Pin IOUT1, Current Source IEXC2
connected to Pin IOUT2.
0
1
Current Source IEXC1 connected to Pin IOUT2, Current Source IEXC2
connected to Pin IOUT1.
1
0
Both current sources connected to Pin IOUT1. Permitted when the current
sources are set to 10 μA or 210 μA only.
1
1
Both current sources connected to Pin IOUT2. Permitted when the current
sources are set to 10 μA or 210 μA only.
These bits are used to enable and disable the current sources along with selecting the value of the
excitation currents.
IEXCEN1
IEXCEN0
Current Source Value
0
0
Excitation Current Disabled.
0
1
10 μA
1
0
210 μA
1
1
1 mA
OFFSET REGISTER
FULL-SCALE REGISTER
RS2, RS1, RS0 = 1, 1, 0; Power-On/Reset = 0x8000
(AD7792)/0x800000 (AD7793)
RS2, RS1, RS0 = 1, 1, 1; Power-On/Reset = 0x5XXX
(AD7792)/0x5XXX00 (AD7793)
Each analog input channel has a dedicated offset register that
holds the offset calibration coefficient for the channel. This
register is 16 bits wide on the AD7792 and 24 bits wide on the
AD7793, and its power-on/reset value is 0x8000(00). The offset
register is used in conjunction with its associated full-scale
register to form a register pair. The power-on-reset value is
automatically overwritten if an internal or system zero-scale
calibration is initiated by the user. The offset register is a
read/write register. However, the AD7792/AD7793 must be
in idle mode or power-down mode when writing to the
offset register.
The full-scale register is a 16-bit register on the AD7792 and a
24-bit register on the AD7793. The full-scale register holds the
full-scale calibration coefficient for the ADC. The
AD7792/AD7793 have 3 full-scale registers, each channel
having a dedicated full-scale register. The full-scale registers are
read/write registers; however, when writing to the full-scale
registers, the ADC must be placed in power-down mode or idle
mode. These registers are configured on power-on with factorycalibrated full-scale calibration coefficients, the calibration
being performed at gain = 1. Therefore, every device has
different default coefficients. The coefficients are different
depending on whether the internal reference or an external
reference is selected. The default value is automatically
overwritten if an internal or system full-scale calibration is
initiated by the user, or the full-scale register is written to.
Rev. B | Page 19 of 32
AD7792/AD7793
ADC CIRCUIT INFORMATION
0
OVERVIEW
The AD7792/AD7793 are low power ADCs that incorporate a
∑-Δ modulator, a buffer, reference, in-amp, and an on-chip
digital filter intended for the measurement of wide dynamic
range, low frequency signals such as those in pressure
transducers, weigh scales, and temperature measurement
applications.
–20
(dB)
–40
–60
The part has three differential inputs that can be buffered or
unbuffered. The device can be operated with the internal 1.17 V
reference, or an external reference can be used. Figure 12 shows
the basic connections required to operate the part.
GND
04855-018
–100
AVDD
VBIAS
0
R C
MUX
Σ-Δ
ADC
IN-AMP
SERIAL
INTERFACE
AND
CONTROL
LOGIC
REFIN(+)
0
DOUT/RDY
DIN
SCLK
CS
–20
DVDD
INTERNAL
CLOCK
AD7792/AD7793
IOUT2
CLK
Figure 12. Basic Connection Diagram
The output rate of the AD7792/AD7793 (fADC) is user-programmable. The allowable update rates, along with their corresponding
settling times, are listed in Table 16. Normal mode rejection is
the major function of the digital filter. Simultaneous 50 Hz and
60 Hz rejection is optimized when the update rate equals
16.7 Hz or less as notches are placed at both 50 Hz and 60 Hz
with these update rates. See Figure 14.
The AD7792/AD7793 use slightly different filter types,
depending on the output update rate so that the rejection of
quantization noise and device noise is optimized. When the
update rate is from 4.17 Hz to 12.5 Hz, a Sinc3 filter, along with
an averaging filter, is used. When the update rate is from
16.7 Hz to 39 Hz, a modified Sinc3 filter is used. This filter
provides simultaneous 50 Hz/60 Hz rejection when the update
rate equals 16.7 Hz. A Sinc4 filter is used when the update rate
is from 50 Hz to 242 Hz. Finally, an integrate-only filter is used
when the update rate equals 470 Hz.
Figure 13 to Figure 16 show the frequency response of the
different filter types for several update rates.
–40
–60
–80
–100
04855-019
AVDD
120
0
20
40
60
80
100
120
140
160
180
200
FREQUENCY (Hz)
Figure 14. Filter Profile with Update Rate = 16.7 Hz
0
–20
–40
–60
–80
–100
04855-020
REFIN(–)
100
(dB)
GND
80
(dB)
BUF
AIN2(–)
60
Figure 13. Filter Profile with Update Rate = 4.17 Hz
GND
AVDD
RREF
40
FREQUENCY (Hz)
BAND GAP
REFERENCE
AIN1(+)
AIN1(–)
AIN2(+)
20
REFIN(+) REFIN(–)
04855-012
THERMOCOUPLE
JUNCTION R
–80
0
500
1000
1500
2000
2500
3000
FREQUENCY (Hz)
Figure 15. Filter Profile with Update Rate = 242 Hz
Rev. B | Page 20 of 32
AD7792/AD7793
0
Figure 3 and Figure 4 show timing diagrams for interfacing to
the AD7792/AD7793 with CS being used to decode the part.
Figure 3 shows the timing for a read operation from the
AD7792/AD7793 output shift register, and Figure 4 shows the
timing for a write operation to the input shift register. It is
possible to read the same word from the data register several
times, even though the DOUT/RDY line returns high after the
first read operation. However, care must be taken to ensure that
the read operations have been completed before the next output
update occurs. In continuous read mode, the data register can
be read only once.
–10
(dB)
–20
–30
–40
–60
04855-021
–50
0
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
FREQUENCY (Hz)
Figure 16. Filter Response at 470 Hz Update Rate
DIGITAL INTERFACE
The programmable functions of the AD7792/AD7793 are
controlled using a set of on-chip registers. Data is written to
these registers via the serial interface of the device; read access
to the on-chip registers is also provided by this interface. All
communications with the device must start with a write to the
communications register. After power-on or reset, the device
expects a write to its communications register. The data written
to this register determines whether the next operation is a read
operation or a write operation and determines to which register
this read or write operation occurs. Therefore, write access to
any of the other registers on the part begins with a write
operation to the communications register followed by a write to
the selected register. A read operation from any other register
(except when continuous read mode is selected) starts with a
write to the communications register followed by a read
operation from the selected register.
The serial interfaces of the AD7792/AD7793 consist of four
signals: CS, DIN, SCLK, and DOUT/RDY. The DIN line is used
to transfer data into the on-chip registers, and DOUT/RDY is
used for accessing from the on-chip registers. SCLK is the serial
clock input for the device, and all data transfers (either on DIN
or DOUT/RDY) occur with respect to the SCLK signal. The
DOUT/RDY pin operates as a data-ready signal also, the line
going low when a new data-word is available in the output
register. It is reset high when a read operation from the data
register is complete. It also goes high prior to the updating of
the data register to indicate when not to read from the device, to
ensure that a data read is not attempted while the register is
being updated. CS is used to select a device. It can be used to
decode the AD7792/AD7793 in systems where several
components are connected to the serial bus.
The serial interface can operate in 3-wire mode by tying CS low.
In this case, the SCLK, DIN, and DOUT/RDY lines are used
to communicate with the AD7792/AD7793. The end of the
conversion can be monitored using the RDY bit in the status
register. This scheme is suitable for interfacing to microcontrollers. If CS is required as a decoding signal, it can be
generated from a port pin. For microcontroller interfaces, it is
recommended that SCLK idle high between data transfers.
The AD7792/AD7793 can be operated with CS being used as a
frame synchronization signal. This scheme is useful for DSP
interfaces. In this case, the first bit (MSB) is effectively clocked
out by CS, because CS would normally occur after the falling
edge of SCLK in DSPs. The SCLK can continue to run between
data transfers, provided the timing numbers are obeyed.
The serial interface can be reset by writing a series of 1s on the
DIN input. If a Logic 1 is written to the AD7792/AD7793 line
for at least 32 serial clock cycles, the serial interface is reset.
This ensures that the interface can be reset to a known state if
the interface gets lost due to a software error or some glitch in
the system. Reset returns the interface to the state in which it is
expecting a write to the communications register. This operation resets the contents of all registers to their power-on values.
Following a reset, the user should allow a period of 500 μs
before addressing the serial interface.
The AD7792/AD7793 can be configured to continuously
convert or to perform a single conversion. See Figure 17
through Figure 19.
Rev. B | Page 21 of 32
AD7792/AD7793
Single Conversion Mode
Continuous Conversion Mode
In single conversion mode, the AD7792/AD7793 are placed in
shutdown mode between conversions. When a single conversion is initiated by setting MD2, MD1, MD0 to 0, 0, 1 in the
mode register, the AD7792/AD7793 power up, perform a single
conversion, and then return to shutdown mode. The on-chip
oscillator requires 1 ms to power up. A conversion requires a
time period of 2 × tADC. DOUT/RDY goes low to indicate the
completion of a conversion. When the data-word has been read
from the data register, DOUT/RDY goes high. If CS is low,
DOUT/RDY remains high until another conversion is initiated
and completed. The data register can be read several times, if
required, even when DOUT/RDY has gone high.
This is the default power-up mode. The AD7792/AD7793
continuously converts, the RDY pin in the status register going
low each time a conversion is completed. If CS is low, the
DOUT/ RDY line also goes low when a conversion is complete.
To read a conversion, the user writes to the communications
register indicating that the next operation is a read of the data
register. The digital conversion is placed on the DOUT/ RDY
pin as soon as SCLK pulses are applied to the ADC.
DOUT/RDY returns high when the conversion is read. The
user can read this register additional times, if required.
However, the user must ensure that the data register is not being
accessed at the completion of the next conversion, otherwise the
new conversion word is lost.
CS
DIN
0x08
0x200A
0x58
DATA
04855-015
DOUT/RDY
SCLK
Figure 17. Single Conversion
CS
0x58
0x58
DIN
DATA
DATA
04855-016
DOUT/RDY
SCLK
Figure 18. Continuous Conversion
Rev. B | Page 22 of 32
AD7792/AD7793
Continuous Read
read before the next conversion is complete. If the user has not
read the conversion before the completion of the next
conversion, or if insufficient serial clocks are applied to the
AD7792/AD7793 to read the word, the serial output register is
reset when the next conversion is completed, and the new
conversion is placed in the output serial register.
Rather than write to the communications register each time a
conversion is complete to access the data, the AD7792/AD7793
can be configured so that the conversions are placed on the
DOUT/RDY line automatically. By writing 01011100 to the
communications register, the user needs only to apply the
appropriate number of SCLK cycles to the ADC, and the 16/24bit word is automatically placed on the DOUT/RDY line when a
conversion is complete. The ADC should be configured for
continuous conversion mode.
To exit the continuous read mode, the instruction 01011000
must be written to the communications register while the
DOUT/RDY pin is low. While in the continuous read mode, the
ADC monitors activity on the DIN line so that it can receive the
instruction to exit the continuous read mode. Additionally, a
reset occurs if 32 consecutive 1s are seen on DIN. Therefore,
DIN should be held low in continuous read mode until an
instruction is written to the device.
When DOUT/RDY goes low to indicate the end of a conversion, sufficient SCLK cycles must be applied to the ADC, and
the data conversion is placed on the DOUT/RDY line. When
the conversion is read, DOUT/RDY returns high until the next
conversion is available. In this mode, the data can be read only
once. In addition, the user must ensure that the data-word is
CS
0x5C
DIN
DATA
DATA
DATA
04855-017
DOUT/RDY
SCLK
Figure 19. Continuous Read
Rev. B | Page 23 of 32
AD7792/AD7793
CIRCUIT DESCRIPTION
ANALOG INPUT CHANNEL
The AD7792/AD7793 have three differential analog input
channels. These are connected to the on-chip buffer amplifier
when the device is operated in buffered mode and directly to
the modulator when the device is operated in unbuffered mode.
In buffered mode (the BUF bit in the mode register is set to 1),
the input channel feeds into a high impedance input stage of the
buffer amplifier. Therefore, the input can tolerate significant
source impedances and is tailored for direct connection to
external resistive-type sensors, such as strain gauges or
resistance temperature detectors (RTDs).
When BUF = 0, the part is operated in unbuffered mode.
This results in a higher analog input current. Note that this
unbuffered input path provides a dynamic load to the driving
source. Therefore, resistor/capacitor combinations on the input
pins can cause gain errors, depending on the output impedance
of the source that is driving the ADC input. Table 19 shows the
allowable external resistance/capacitance values for unbuffered
mode such that no gain error at the 20-bit level is introduced.
Table 19. External R-C Combination for No 20-Bit Gain Error
C (pF)
R (Ω)
50
9k
100
6k
500
1.5 k
1000
900
5000
200
The AD7792/AD7793 can be operated in unbuffered mode only
when the gain equals 1 or 2. At higher gains, the buffer is automatically enabled. The absolute input voltage range in buffered
mode is restricted to a range between GND + 100 mV and
AVDD – 100 mV. When the gain is set to 4 or higher, the in-amp
is enabled. The absolute input voltage range when the in-amp is
active is restricted to a range between GND + 300 mV and
AVDD − 1.1 V. Take care in setting up the common-mode
voltage so that these limits are not exceeded to avoid
degradation in linearity and noise performance.
The absolute input voltage in unbuffered mode includes the
range between GND – 30 mV and AVDD + 30 mV as a result of
being unbuffered. The negative absolute input voltage limit does
allow the possibility of monitoring small true bipolar signals
with respect to GND.
INSTRUMENTATION AMPLIFIER
Amplifying the analog input signal by a gain of 1 or 2 is
performed digitally within the AD7792/AD7793. However,
when the gain equals 4 or higher, the output from the buffer is
applied to the input of the on-chip instrumentation amplifier.
This low noise in-amp means that signals of small amplitude
can be gained within the AD7792/AD7793 while still
maintaining excellent noise performance.
For example, when the gain is set to 64, the rms noise is 40 nV
typically, which is equivalent to 21 bits effective resolution or
18.5 bits peak-to-peak resolution.
The AD7792/AD7793 can be programmed to have a gain of 1,
2, 4, 8, 16, 32, 64, and 128 using Bit G2 to Bit G0 in the configuration register. Therefore, with an external 2.5 V reference, the
unipolar ranges are from 0 mV to 20 mV to 0 V to 2.5 V while
the bipolar ranges are from ±20 mV to ±2.5 V. When the
in-amp is active (gain ≥ 4), the common-mode voltage (AIN(+)
+ AIN(–))/2 must be greater than or equal to 0.5 V.
If the AD7792/AD7793 are operated with an external reference
that has a value equal to AVDD, the analog input signal must be
limited to 90% of VREF/gain when the in-amp is active, for
correct operation.
BIPOLAR/UNIPOLAR CONFIGURATION
The analog input to the AD7792/AD7793 can accept either
unipolar or bipolar input voltage ranges. A bipolar input range
does not imply that the part can tolerate negative voltages with
respect to system GND. Unipolar and bipolar signals on the
AIN(+) input are referenced to the voltage on the AIN(–) input.
For example, if AIN(−) is 2.5 V, and the ADC is configured for
unipolar mode and a gain of 1, the input voltage range on the
AIN(+) pin is 2.5 V to 5 V.
If the ADC is configured for bipolar mode, the analog input
range on the AIN(+) input is 0 V to 5 V. The bipolar/unipolar
option is chosen by programming the U/B bit in the configuration register.
DATA OUTPUT CODING
When the ADC is configured for unipolar operation, the output
code is natural (straight) binary with a zero differential input
voltage resulting in a code of 00...00, a midscale voltage
resulting in a code of 100...000, and a full-scale input voltage
resulting in a code of 111...111. The output code for any analog
input voltage can be represented as
Code = (2N × AIN × GAIN)/VREF
When the ADC is configured for bipolar operation, the output
code is offset binary with a negative full-scale voltage resulting
in a code of 000...000, a zero differential input voltage resulting
in a code of 100...000, and a positive full-scale input voltage
resulting in a code of 111...111. The output code for any analog
input voltage can be represented as
Code = 2N – 1 × [(AIN × GAIN /VREF) + 1]
where AIN is the analog input voltage, GAIN is the in-amp
setting (1 to 128), and N = 16 for the AD7792 and N = 24 for
the AD7793.
Rev. B | Page 24 of 32
AD7792/AD7793
BURNOUT CURRENTS
The AD7792/AD7793 contain two 100 nA constant current
generators, one sourcing current from AVDD to AIN(+) and one
sinking current from AIN(–) to GND. The currents are
switched to the selected analog input pair. Both currents are
either on or off, depending on the burnout current enable (BO)
bit in the configuration register. These currents can be used to
verify that an external transducer is still operational before
attempting to take measurements on that channel. Once the
burnout currents are turned on, they flow in the external
transducer circuit, and a measurement of the input voltage on
the analog input channel can be taken. If the resultant voltage
measured is full scale, the user needs to verify why this is the
case. A full-scale reading could mean that the front-end sensor
is open circuit. It could also mean that the front-end sensor is
overloaded and is justified in outputting full scale, or the
reference may be absent, thus clamping the data to all 1s.
When reading all 1s from the output, the user needs to check
these three cases before making a judgment. If the voltage
measured is 0 V, it may indicate that the transducer has short
circuited. For normal operation, these burnout currents are
turned off by writing a 0 to the BO bit in the configuration
register. The current sources work over the normal absolute
input voltage range specifications with buffers on.
EXCITATION CURRENTS
The AD7792/AD7793 also contain two matched, software
configurable, constant current sources that can be programmed
to equal 10 μA, 210 μA, or 1 mA. Both source currents from the
AVDD are directed to either the IOUT1 or IOUT2 pin of the
device. These current sources are controlled via bits in the IO
register. The configuration bits enable the current sources,
direct the current sources to IOUT1 or IOUT2, and select the
value of the current. These current sources can be used to excite
external resistive bridge or RTD sensors.
BIAS VOLTAGE GENERATOR
A bias voltage generator is included on the AD7792/AD7793.
This biases the negative terminal of the selected input channel
to AVDD/2. It is useful in thermocouple applications, because the
voltage generated by the thermocouple must be biased about
some dc voltage if the gain is greater than 2. This is necessary
because the instrumentation amplifier requires headroom to
ensure that signals close to GND or AVDD are converted
accurately.
The bias voltage generator is controlled using the VBIAS1 and
VBIAS0 bits in conjunction with the boost bit in the configuration register. The power-up time of the bias voltage generator is
dependent on the load capacitance. To accommodate higher
load capacitances, the AD7792/AD7793 have a boost bit. When
this bit is set to 1, the current consumed by the bias voltage
generator increases, so that the power-up time is considerably
reduced. Figure 10 shows the power-up time when boost equals
0 and 1 for different load capacitances.
The current consumption of the AD7792/AD7793 increases by
40 μA when the bias voltage generator is enabled, and boost
equals 0. With the boost function enabled, the current
consumption increases by 250 μA.
REFERENCE
The AD7792/AD7793 have an embedded 1.17 V reference that
can be used to supply the ADC, or an external reference can be
applied. The embedded reference is a low noise, low drift
reference, the drift being 4 ppm/°C typically. For external
references, the ADC has a fully differential input capability for
the channel. The reference source for the AD7792/AD7793 is
selected using the REFSEL bit in the configuration register.
When the internal reference is selected, it is internally connected to the modulator. It is not available on the REFIN pins.
The common-mode range for these differential inputs is from
GND to AVDD. The reference input is unbuffered; therefore,
excessive R-C source impedances introduce gain errors. The
reference voltage REFIN (REFIN(+) − REFIN(−)) is 2.5 V
nominal, but the AD7792/AD7793 are functional with reference
voltages from 0.1 V to AVDD. In applications where the excitation (voltage or current) for the transducer on the analog
input also drives the reference voltage for the part, the effect
of the low frequency noise in the excitation source is removed
because the application is ratiometric. If the AD7792/AD7793
are used in a nonratiometric application, a low noise reference
should be used.
Recommended 2.5 V reference voltage sources for the AD7792/
AD7793 include the ADR381 and ADR391, which are low noise,
low power references. Also note that the reference inputs
provide a high impedance, dynamic load. Because the input
impedance of each reference input is dynamic, resistor/capacitor
combinations on these inputs can cause dc gain errors, depending
on the output impedance of the source that is driving the
reference inputs.
Reference voltage sources like those recommended above (such
as ADR391) typically have low output impedances and are,
therefore, tolerant to having decoupling capacitors on REFIN(+)
without introducing gain errors in the system. Deriving the
reference input voltage across an external resistor means that
the reference input sees a significant external source impedance.
External decoupling on the REFIN pins is not recommended in
this type of circuit configuration.
RESET
The circuitry and serial interface of the AD7792/AD7793 can
be reset by writing 32 consecutive 1s to the device. This resets
the logic, the digital filter, and the analog modulator while all
on-chip registers are reset to their default values. A reset is
automatically performed on power-up. When a reset is initiated,
the user must allow a period of 500 μs before accessing any of
the on-chip registers. A reset is useful if the serial interface
becomes asynchronous due to noise on the SCLK line.
Rev. B | Page 25 of 32
AD7792/AD7793
AVDD MONITOR
Along with converting external voltages, the ADC can be used
to monitor the voltage on the AVDD pin. When Bit CH2 to
Bit CH0 equal 1, the voltage on the AVDD pin is internally
attenuated by 6, and the resultant voltage is applied to the ∑-Δ
modulator using an internal 1.17 V reference for analog-todigital conversion. This is useful, because variations in the
power supply voltage can be monitored.
CALIBRATION
The AD7792/AD7793 provide four calibration modes that can
be programmed via the mode bits in the mode register. These
are internal zero-scale calibration, internal full-scale calibration,
system zero-scale calibration, and system full-scale calibration,
which effectively reduces the offset error and full-scale error to
the order of the noise. After each conversion, the ADC conversion result is scaled using the ADC calibration registers
before being written to the data register. The offset calibration
coefficient is subtracted from the result prior to multiplication
by the full-scale coefficient.
To start a calibration, write the relevant value to the MD2 to
MD0 bits in the mode register. After the calibration is complete,
the contents of the corresponding calibration registers are
updated, the RDY bit in the status register is set, the DOUT/
RDY pin goes low (if CS is low), and the AD7792/AD7793
revert to idle mode.
During an internal zero-scale or full-scale calibration, the
respective zero input and full-scale input are automatically
connected internally to the ADC input pins. A system
calibration, however, expects the system zero-scale and system
full-scale voltages to be applied to the ADC pins before the
calibration mode is initiated. In this way, external ADC errors
are removed.
From an operational point of view, a calibration should be
treated like another ADC conversion. A zero-scale calibration
(if required) should always be performed before a full-scale
calibration. System software should monitor the RDY bit in
the status register or the DOUT/RDY pin to determine the
end of calibration via a polling sequence or an interrupt-driven
routine.
Both an internal offset calibration and a system offset
calibration take two conversion cycles. An internal offset
calibration is not needed, as the ADC itself removes the offset
continuously.
To perform an internal full-scale calibration, a full-scale input
voltage is automatically connected to the selected analog input
for this calibration. When the gain equals 1, a calibration takes
2 conversion cycles to complete. For higher gains, 4 conversion
cycles are required to perform the full-scale calibration.
DOUT/RDY goes high when the calibration is initiated and
returns low when the calibration is complete.
The ADC is placed in idle mode following a calibration. The
measured full-scale coefficient is placed in the full-scale register
of the selected channel. Internal full-scale calibrations cannot be
performed when the gain equals 128. With this gain setting, a
system full-scale calibration can be performed. A full-scale
calibration is required each time the gain of a channel is
changed to minimize the full-scale error.
An internal full-scale calibration can be performed at specified
update rates only. For gains of 1, 2, and 4, an internal full-scale
calibration can be performed at any update rate. However, for
higher gains, internal full-scale calibrations can be performed
when the update rate is less than or equal to 16.7 Hz, 33.2 Hz,
and 50 Hz only. However, the full-scale error does not vary with
update rate, so a calibration at one update rate is valid for all
update rates (assuming the gain or reference source is not
changed).
A system full-scale calibration takes 2 conversion cycles to
complete, irrespective of the gain setting. A system full-scale
calibration can be performed at all gains and all update rates. If
system offset calibrations are being performed along with
system full-scale calibrations, the offset calibration should be
performed before the system full-scale calibration is initiated.
GROUNDING AND LAYOUT
Because the analog inputs and reference inputs of the ADC are
differential, most of the voltages in the analog modulator are
common-mode voltages. The excellent common-mode rejection of the part removes common-mode noise on these inputs.
The digital filter provides rejection of broadband noise on the
power supply, except at integer multiples of the modulator
sampling frequency. The digital filter also removes noise from
the analog and reference inputs, provided that these noise
sources do not saturate the analog modulator. As a result, the
AD7792/AD7793 are more immune to noise interference than a
conventional high resolution converter. However, because the
resolution of the AD7792/AD7793 is so high, and the noise
levels from the AD7792/AD7793 are so low, care must be taken
with regard to grounding and layout.
The printed circuit board that houses the AD7792/AD7793
should be designed such that the analog and digital sections are
separated and confined to certain areas of the board. A minimum etch technique is generally best for ground planes because
it provides the best shielding.
It is recommended that the GND pins of the AD7792/AD7793
be tied to the AGND plane of the system. In any layout, it is
important to keep in mind the flow of currents in the system,
ensuring that the return paths for all currents are as close as
possible to the paths the currents took to reach their destinations.
Avoid forcing digital currents to flow through the AGND
sections of the layout.
Rev. B | Page 26 of 32
AD7792/AD7793
The ground planes of the AD7792/AD7793 should be allowed
to run under the AD7792/AD7793 to prevent noise coupling.
The power supply lines to the AD7792/AD7793 should use as
wide a trace as possible to provide low impedance paths and
reduce the effects of glitches on the power supply line. Fast
switching signals such as clocks should be shielded with digital
ground to avoid radiating noise to other sections of the board,
and clock signals should never be run near the analog inputs.
Avoid crossover of digital and analog signals. Traces on
opposite sides of the board should run at right angles to each
other. This reduces the effects of feedthrough through the
board. A microstrip technique is by far the best, but it is not
always possible with a double-sided board. In this technique,
the component side of the board is dedicated to ground planes,
and signals are placed on the solder side.
Good decoupling is important when using high resolution
ADCs. AVDD should be decoupled with 10 μF tantalum in
parallel with 0.1 μF capacitors to GND. DVDD should be
decoupled with 10 μF tantalum in parallel with 0.1 μF
capacitors to the system’s DGND plane, with the system’s
AGND to DGND connection being close to the
AD7792/AD7793.
To achieve the best from these decoupling components, they
should be placed as close as possible to the device, ideally right
up against the device. All logic chips should be decoupled with
0.1 μF ceramic capacitors to DGND.
Rev. B | Page 27 of 32
AD7792/AD7793
APPLICATIONS INFORMATION
amplify the signal from the thermocouple. As the input channel
is buffered, large decoupling capacitors can be placed on the
front end to eliminate any noise pickup that may be present in
the thermocouple leads. The AD7792/AD7793 have a reduced
common-mode range with the in-amp enabled, so the bias
voltage generator provides a common-mode voltage so that the
voltage generated by the thermocouple is biased up to AVDD/2.
The AD7792/AD7793 provide a low cost, high resolution
analog-to-digital function. Because the analog-to-digital
function is provided by a ∑-Δ architecture, the parts are more
immune to noisy environments, making them ideal for use in
sensor measurement and industrial and process control
applications.
TEMPERATURE MEASUREMENT USING A
THERMOCOUPLE
The cold junction compensation is performed using a thermistor in the diagram. The on-chip excitation current supplies the
thermistor. In addition, the reference voltage for the cold
junction measurement is derived from a precision resistor in
series with the thermistor. This allows a ratiometric measurement so that variation of the excitation current has no effect on
the measurement (it is the ratio of the precision reference
resistance to the thermistor resistance that is measured).
Figure 20 outlines a connection from a thermocouple to the
AD7792/AD7793. In a thermocouple application, the voltage
generated by the thermocouple is measured with respect to an
absolute reference, so the internal reference is used for this
conversion. The cold junction measurement uses a ratiometric
configuration, so the reference is provided externally.
Because the signal from the thermocouple is small, the
AD7792/AD7793 are operated with the in-amp enabled to
GND
AVDD
VBIAS
REFIN(+) REFIN(–)
BAND GAP
REFERENCE
AIN1(+)
AIN1(–)
GND
AVDD
R C
AIN2(+)
MUX
BUF
AIN2(–)
SERIAL
INTERFACE
AND
CONTROL
LOGIC
Σ-Δ
ADC
IN-AMP
REFIN(+)
RREF
GND
REFIN(–)
AVDD
DOUT/RDY
DIN
SCLK
CS
DVDD
INTERNAL
CLOCK
AD7792/AD7793
IOUT2
CLK
Figure 20. Thermocouple Measurement Using the AD7792/AD7793
Rev. B | Page 28 of 32
04855-012
THERMOCOUPLE
JUNCTION R
AD7792/AD7793
material and of equal length), and IOUT1 and IOUT2 match,
the error voltage across RL2 equals the error voltage across RL1,
and no error voltage is developed between AIN1(+) and
AIN1(–). Twice the voltage is developed across RL3 but,
because this is a common-mode voltage, it does not introduce
errors. The reference voltage for the AD7792/AD7793 is also
generated using one of these matched current sources. It is
developed using a precision resistor and applied to the
differential reference pins of the ADC. This scheme ensures that
the analog input voltage span remains ratiometric to the
reference voltage. Any errors in the analog input voltage due to
the temperature drift of the excitation current are compensated
by the variation of the reference voltage.
TEMPERATURE MEASUREMENT USING AN RTD
To optimize a 3-wire RTD configuration, two identically
matched current sources are required. The AD7792/AD7793,
which contain two well-matched current sources, are ideally
suited to these applications. One possible 3-wire configuration
is shown in Figure 21. In this 3-wire configuration, the lead
resistances result in errors if only one current is used, as the
excitation current flows through RL1, developing a voltage error
between AIN1(+) and AIN1(–). In the scheme outlined, the
second RTD current source is used to compensate for the error
introduced by the excitation current flowing through RL1. The
second RTD current flows through RL2. Assuming RL1 and
RL2 are equal (the leads would normally be of the same
GND
AVDD
REFIN(+) REFIN(–)
BAND GAP
REFERENCE
IOUT1
RTD
RL2
RL3
AIN1(+)
GND
AVDD
AIN1(–)
BUF
IOUT2
Σ-Δ
ADC
IN-AMP
SERIAL
INTERFACE
AND
CONTROL
LOGIC
DOUT/RDY
DIN
SCLK
CS
REFIN(+)
GND
RREF
REFIN(–)
INTERNAL
CLOCK
AD7792/AD7793
CLK
Figure 21. RTD Application Using the AD7792/AD7793
Rev. B | Page 29 of 32
DVDD
04855-013
RL1
AD7792/AD7793
OUTLINE DIMENSIONS
5.10
5.00
4.90
16
9
4.50
4.40
4.30
6.40
BSC
1
8
PIN 1
1.20
MAX
0.15
0.05
0.65
BSC
0.30
0.19
COPLANARITY
0.10
0.20
0.09
8°
0°
SEATING
PLANE
0.75
0.60
0.45
COMPLIANT TO JEDEC STANDARDS MO-153-AB
Figure 22. 16-Lead Thin Shrink Small Outline Package [TSSOP]
(RU-16)
Dimensions shown in millimeters
ORDERING GUIDE
Model
AD7792BRU
AD7792BRU-REEL
AD7792BRUZ 1
AD7792BRUZ-REEL1
AD7793BRU
AD7793BRU-REEL
AD7793BRUZ1
AD7793BRUZ-REEL1
EVAL-AD7792EBZ1
EVAL-AD7793EBZ1
1
Temperature Range
–40°C to +105°C
–40°C to +105°C
–40°C to +105°C
–40°C to +105°C
–40°C to +105°C
–40°C to +105°C
–40°C to +105°C
–40°C to +105°C
Package Description
16-Lead TSSOP
16-Lead TSSOP
16-Lead TSSOP
16-Lead TSSOP
16-Lead TSSOP
16-Lead TSSOP
16-Lead TSSOP
16-Lead TSSOP
Evaluation Board
Evaluation Board
Z = RoHS Compliant Part.
Rev. B | Page 30 of 32
Package Option
RU-16
RU-16
RU-16
RU-16
RU-16
RU-16
RU-16
RU-16
AD7792/AD7793
NOTES
Rev. B | Page 31 of 32
AD7792/AD7793
NOTES
©2004–2007 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D04855-0-3/07(B)
Rev. B | Page 32 of 32