For instructions. Pkease please see: see: http://www.erni.com/DB/derating/DERATING-Instructions.pdf DERATING CURVE (Current carrying capacity acc. IEC 60512-5-2 Test 5b) MiniBridge A/P 2p with 250 mm stranded flat ribbon cable AWG 26 max component temperature 125°C 6 Current (A] 7 5 4 3 2 Temperature [°C] Base curve [A] Derating curve [A] 1 0 20 30 40 50 60 70 80 90 100 110 120 Base curve [A] 0 6,10 5,80 5,50 5,15 4,80 4,40 4,00 3,50 2,95 2,30 1,40 Derating curve [A] 4,88 4,64 4,40 4,12 3,84 3,52 3,20 2,80 2,36 1,84 1,12 © ERNI Electronics GmbH 2009 10 All rights reserved. Only for information. Subject to modification without prior notice. 130