OP90: Military Data Sheet (Rev. B)

REVISIONS
LTR
DESCRIPTION
DATE (YR-MO-DA)
APPROVED
A
Changes in accordance with N.O.R. 5962-R238-93.
93-09-30
M. A. FRYE
B
Drawing being updated to reflect current requirements. -ro
01-03-15
R. MONNIN
C
Update drawing as part of 5 year review. -rrp
07-06-20
ROBERT M. HEBER
REV
SHEET
REV
SHEET
REV STATUS
REV
C
C
C
C
C
C
C
C
C
OF SHEETS
SHEET
1
2
3
4
5
6
7
8
9
PMIC N/A
PREPARED BY
RICK C. OFFICER
STANDARD
MICROCIRCUIT
DRAWING
THIS DRAWING IS AVAILABLE
FOR USE BY ALL
DEPARTMENTS
AND AGENCIES OF THE
DEPARTMENT OF DEFENSE
AMSC N/A
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
http://www.dscc.dla.mil
CHECKED BY
CHARLES E. BESORE
APPROVED BY
MICHAEL A. FRYE
MICROCIRCUIT, LINEAR, PRECISION, LOW
POWER, LOW VOLTAGE, OPERATIONAL
AMPLIFIER, MONOLITHIC SILICON
DRAWING APPROVAL DATE
93-09-15
REVISION LEVEL
C
SIZE
CAGE CODE
A
67268
SHEET
DSCC FORM 2233
APR 97
1 OF
5962-89896
9
5962-E354-06
1. SCOPE
1.1 Scope. This drawing describes device requirements for MIL-STD-883 compliant, non-JAN class level B microcircuits in
accordance with MIL-PRF-38535, appendix A.
1.2 Part or Identifying Number (PIN). The complete PIN is as shown in the following example:
5962-89896
01
P
X
Drawing number
Device type
(see 1.2.1)
Case outline
(see 1.2.2)
Lead finish
(see 1.2.3)
1.2.1 Device type(s). The device type(s) identify the circuit function as follows:
Device type
Generic number
01
Circuit function
OP90A
Precision, low power, low voltage operational
amplifier
1.2.2 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows:
Outline letter
P
2
Descriptive designator
GDIP1-T8 or CDIP2-T8
CQCC1-N20
Terminals
Package style
8
20
Dual-in-line
Square leadless chip carrier
1.2.3 Lead finish. The lead finish is as specified in MIL-PRF-38535, appendix A.
1.3 Absolute maximum ratings.
Supply voltage (VS) ............................................................. ±18 V dc
Input voltage ........................................................................ [(-VS) – 20 V] to [(+VS) + 20 V]
Differential input voltage ...................................................... [(-VS) – 20 V] to [(+VS) + 20 V]
Power dissipation (PD) ........................................................
Output short-circuit duration ................................................
Storage temperature range .................................................
Lead temperature range (soldering, 60 seconds) ................
Junction temperature (TJ) ...................................................
500 mW
Continuous
-65°C to +150°C
+300°C
-65°C to +150°C
Thermal resistance, junction-to-case (θJC) ......................... See MIL-STD-1835
Thermal resistance, junction-to-ambient (θJA):
Case P ............................................................................. +119°C/W
Case 2 ............................................................................. +120°C/W
1.4 Recommended operating conditions.
Supply voltage (VS) ............................................................. ±1.5 V dc to ±15 V dc
Source resistance (RS) ....................................................... 50 Ω
Ambient operating temperature range (TA) ......................... -55°C to +125°C
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-89896
A
REVISION LEVEL
C
SHEET
2
2. APPLICABLE DOCUMENTS
2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part
of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the
solicitation or contract.
DEPARTMENT OF DEFENSE SPECIFICATION
MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-883 MIL-STD-1835 -
Test Method Standard Microcircuits.
Interface Standard Electronic Component Case Outlines.
DEPARTMENT OF DEFENSE HANDBOOKS
MIL-HDBK-103 MIL-HDBK-780 -
List of Standard Microcircuit Drawings.
Standard Microcircuit Drawings.
(Copies of these documents are available online at http://assist.daps.dla.mil/quicksearch/ or http://assist.daps.dla.mil or
from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text
of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535, appendix A for nonJAN class level B devices and as specified herein. Product built to this drawing that is produced by a Qualified Manufacturer
Listing (QML) certified and qualified manufacturer or a manufacturer who has been granted transitional certification to MILPRF-38535 may be processed as QML product in accordance with the manufacturers approved program plan and qualifying
activity approval in accordance with MIL-PRF-38535. This QML flow as documented in the Quality Management (QM) plan
may make modifications to the requirements herein. These modifications shall not affect form, fit, or function of the device.
These modifications shall not affect the PIN as described herein. A "Q" or "QML" certification mark in accordance with MILPRF-38535 is required to identify when the QML flow option is used.
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified
in MIL-PRF-38535, appendix A and herein.
3.2.1 Case outline. The case outline shall be in accordance with 1.2.2 herein.
3.2.2 Terminal connections. The terminal connections shall be as specified on figure 1.
3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are
as specified in table I and shall apply over the full ambient operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical
tests for each subgroup are described in table I.
3.5 Marking. Marking shall be in accordance with MIL-PRF-38535, appendix A. The part shall be marked with the PIN listed
in 1.2 herein. In addition, the manufacturer's PIN may also be marked. For packages where marking of the entire SMD PIN
number is not feasible due to space limitations, the manufacturer has the option of not marking the "5962-" on the device.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-89896
A
REVISION LEVEL
C
SHEET
3
TABLE I. Electrical performance characteristics.
Test
Symbol
Conditions 1/
-55°C ≤ TA ≤ +125°C
unless otherwise specified
Group A
subgroups
Device
type
1
01
Min
Input offset voltage
VOS
IOS
1
VCM = 0 V
±3
01
+IB
-IB
Supply current
ISY
1
VCM = 0 V
VCM = 0 V
VS = ±15 V, no load
Power supply rejection
ratio
PSRR
±20
1
±15
2,3
±20
01
15
2,3
25
1
20
2,3
30
1
VS = ±1.5 V, ±15 V
±15
01
2,3
1
VS = ±1.5 V, no load
±5.6
01
en
4
VS = ±15 V, fO = 50 Hz 3/
nA
nA
µA
µV/V
±10.0
2,3
Input noise voltage
density
µV
±5
2,3
Input bias current
Max
±150
±400
2,3
Input offset current
Unit
Limits 2/
01
4
75
nV /
Hz
TA = +25°C
Input voltage range 4/
IVR
1
+VS = +5 V, -VS = 0 V
VS = ±15 V
Large-signal voltage gain
AVO
RL = 100 kΩ
VS = ±15 V, VO = ±10 V,
RL = 10 kΩ
0 to
+4
2,3
0 to
+3.5
1,2,3
-15 to
+13.5
4
VS = ±15 V, VO = ±10 V,
01
01
V
700
5,6
225
4
350
5,6
125
V/mV
See footnotes at end of table.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-89896
A
REVISION LEVEL
C
SHEET
4
TABLE I. Electrical performance characteristics – Continued.
Symbol
Conditions 1/
-55°C ≤ TA ≤ +125°C
unless otherwise specified
AVO
VS = ±15 V, VO = ±10 V,
Test
Large-signal voltage gain
Group A
subgroups
Device
type
4
01
RL = 2 kΩ
+VS = 5 V, -VS = 0 V,
VO = 1 V, 4 V, RL = 100 kΩ
+VS = 5 V, -VS = 0 V,
VO = 1 V, 4 V, RL = 10 kΩ
Output voltage swing
VO
VS = ±15 V, RL = 2 kΩ
VOH
+VS = +5 V, -VS = 0 V,
RL = 2 kΩ
VOL
Min
125
5,6
50
4
200
5,6
100
4
100
5,6
50
1
VS = ±15 V, RL = 10 kΩ
Max
V/mV
±14
01
2,3
±13.5
1
±11
2,3
±10.5
1
4.0
2,3
3.9
1,2,3
+VS = +5 V, -VS = 0 V,
Unit
Limits 2/
V
500
µV
RL = 10 kΩ
Common mode rejection
mode
CMRR
1
+VS = +5 V, -VS = 0 V,
01
90
dB
VCM = 0 V, 4 V
+VS = +5 V, -VS = 0 V,
2,3
85
1
100
2,3
95
VCM = 0 V, 3.5 V
VS = ±15 V,
VCM = -15 V, 13.5 V
See footnotes at end of table.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-89896
A
REVISION LEVEL
C
SHEET
5
TABLE I. Electrical performance characteristics – Continued.
Test
Slew rate
Symbol
Conditions 1/
-55°C ≤ TA ≤ +125°C
unless otherwise specified
+SR
VS = ±15 V, rising edge,
Group A
subgroups
Device
type
7
01
Unit
Limits 2/
Min
5
Max
V/ms
no load, AV = 1,
VOUT = -10 V to +10 V,
measured from –5 V to +5 V,
TA = +25°C
-SR
5
VS = ±15 V, falling edge,
no load, AV = 1,
VOUT = +10 V to -10 V,
measured from +5 V to -5 V,
TA = +25°C
Input offset voltage
temperature coefficient
TCVOS
8
VS = ±15 V, RS = 50 Ω,
±2.5
01
µV/°C
TA = -55°C, +125°C
1/
Unless otherwise specified, VS = ±1.5 V, ±15 V, and RS = 50 Ω.
2/
The limiting terms “min” (minimum) and “max” (maximum) shall be considered to apply to magnitudes only. Negative
current shall be defined as conventional current flow out of a device terminal.
3/
If not tested, shall be guaranteed to the limits specified in table I herein.
4/
IVR guaranteed by CMRR test.
3.5.1 Certification/compliance mark. A compliance indicator “C” shall be marked on all non-JAN devices built in compliance
to MIL-PRF-38535, appendix A. The compliance indicator “C” shall be replaced with a "Q" or "QML" certification mark in
accordance with MIL-PRF-38535 to identify when the QML flow option is used.
3.6 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to be listed as an
approved source of supply in MIL-HDBK-103 (see 6.6 herein). The certificate of compliance submitted to DSCC-VA prior to
listing as an approved source of supply shall affirm that the manufacturer's product meets the requirements of MIL-PRF-38535,
appendix A and the requirements herein.
3.7 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38535, appendix A shall be provided
with each lot of microcircuits delivered to this drawing.
3.8 Notification of change. Notification of change to DSCC-VA shall be required for any change that affects this drawing.
3.9 Verification and review. DSCC, DSCC's agent, and the acquiring activity retain the option to review the manufacturer's
facility and applicable required documentation. Offshore documentation shall be made available onshore at the option of the
reviewer.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-89896
A
REVISION LEVEL
C
SHEET
6
Device type
01
Case outlines
P
2
Terminal
number
1
Terminal symbol
VOSNULL
NC
2
-INPUT
VOSNULL
3
+INPUT
NC
4
-VS
NC
5
VOSNULL
-INPUT
6
OUTPUT
NC
7
+VS
+INPUT
8
NC
NC
9
---
NC
10
---
-VS
11
---
NC
12
---
NC
13
---
NC
14
---
NC
15
---
OUTPUT
16
---
NC
17
---
+VS
18
---
NC
19
---
NC
20
---
VOSNULL
NC = No connection
FIGURE 1. Terminal connections.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-89896
A
REVISION LEVEL
C
SHEET
7
4. VERIFICATION
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535,
appendix A.
4.2 Screening. Screening shall be in accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices
prior to quality conformance inspection. The following additional criteria shall apply:
a.
Burn-in test, method 1015 of MIL-STD-883.
(1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify
the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method
1015 of MIL-STD-883.
(2) TA = +125°C, minimum.
b.
Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter
tests prior to burn-in are optional at the discretion of the manufacturer.
4.3 Quality conformance inspection. Quality conformance inspection shall be in accordance with method 5005 of MIL-STD883 including groups A, B, C, and D inspections. The following additional criteria shall apply.
4.3.1 Group A inspection.
a.
Tests shall be as specified in table II herein.
b.
Subgroups 9, 10, and 11 in table I, method 5005 of MIL-STD-883 shall be omitted.
4.3.2 Groups C and D inspections.
a.
End-point electrical parameters shall be as specified in table II herein.
b.
Steady-state life test conditions, method 1005 of MIL-STD-883.
(1)
Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision
level control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in
method 1005 of MIL-STD-883.
(2)
TA = +125°C, minimum.
(3)
Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-89896
A
REVISION LEVEL
C
SHEET
8
TABLE II. Electrical test requirements.
MIL-STD-883 test requirements
Interim electrical parameters
(method 5004)
Final electrical test parameters
(method 5004)
Group A test requirements
(method 5005)
Groups C and D end-point
electrical parameters
(method 5005)
Subgroups
(in accordance with
MIL-STD-883, method 5005,
table I)
1
1*, 2, 3
1, 2, 3, 4, 5, 6, 7, 8
1
* PDA applies to subgroup 1.
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535, appendix A.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
(original equipment), design applications, and logistics purposes.
6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractorprepared specification or drawing.
6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
6.4 Record of users. Military and industrial users shall inform Defense Supply Center Columbus (DSCC) when a system
application requires configuration control and the applicable SMD. DSCC will maintain a record of users and this list will be
used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronics devices (FSC
5962) should contact DSCC-VA, telephone (614) 692-0544.
6.5 Comments. Comments on this drawing should be directed to DSCC-VA, Columbus, Ohio 43218-3990, or telephone
(614) 692-0547
6.6 Approved sources of supply. Approved sources of supply are listed in MIL-HDBK-103. The vendors listed in MILHDBK-103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been submitted to and accepted by
DSCC-VA.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
5962-89896
A
REVISION LEVEL
C
SHEET
9
STANDARD MICROCIRCUIT DRAWING BULLETIN
DATE: 07-06-20
Approved sources of supply for SMD 5962-89896 are listed below for immediate acquisition information only and shall
be added to MIL-HDBK-103 and QML-38535 during the next revision. MIL-HDBK-103 and QML-38535 will be revised
to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a certificate
of compliance has been submitted to and accepted by DSCC-VA. This information bulletin is superseded by the next
dated revision of MIL-HDBK-103 and QML-38535. DSCC maintains an online database of all current sources of
supply at http://www.dscc.dla.mil/Programs/Smcr/ .
Standard
microcircuit drawing
PIN 1/
Vendor
CAGE
number
Vendor
similar
PIN 2/
5962-8989601PA
3/
OP90AZ/883
5962-89896012A
24355
OP90ARC/883
1/ The lead finish shown for each PIN representing
a hermetic package is the most readily available
from the manufacturer listed for that part. If the
desired lead finish is not listed contact the vendor
to determine its availability.
2/ Caution. Do not use this number for item
acquisition. Items acquired to this number may not
satisfy the performance requirements of this drawing.
3/ Not available from an approved source of supply.
Vendor CAGE
number
24355
Vendor name
and address
Analog Devices
RT 1 Industrial Park
P.O. Box 9106
Norwood, MA 02062
Point of contact: 804 Woburn Street
Wilmington, MA 01887-3462
The information contained herein is disseminated for convenience only and the
Government assumes no liability whatsoever for any inaccuracies in the
information bulletin.