Flow Measurement
SITRANS F US Clamp-on
SITRANS FUT1010 (Liquid and Gas)
■ Overview
■ Application
Liquid applications
Custody transfer, allo- Upstream
cation, line balance,
interface/densitometer
Terminals
Check metering,
Midstream Underground stortransmix metering,
age, transmission,
product identification
compressor stations
Refineries Process control,
blending, tank measurement, ship loading and unloading
3
SITRANS FUT1010 is the latest ultrasonic flow meter from
Siemens. Ideal for applications within the liquid and gas hydrocarbon industry capable of providing custody transfer accuracy.
With the newly developed permanent TransLoc™ mounting system, the sensors are permanently mounted on the outside of the
pipe, eliminating any contact with the medium.
SITRANS FUT1010 is available in two different configurations; a
version for liquid hydrocarbon applications and a version for precise gas measurement. Both versions are offered in pipe sizes
ranging from 4 inch to 24 inch (DN 100 to DN 600) with flange
ratings of ANSI Class 150/300/600 for liquid and 300/600 for
gas.
■ Benefits
Transportation
Crude oil pipelines,
LPG pipelines, multiple product pipelines,
airport facilities, liquid
terminals
Downstream
Petrochemical and
processing plants
Downstream
Production wells,
gathering, separation
and dehydration
Electric power generation, industrial use,
gas processing plants
■ Design
SITRANS FUT1010 is available in two different configurations,
both featuring the TransLoc mounting system:
• A version for liquid hydrocarbon applications
• A version for precise gas measurement
Transmitter
SITRANS FUT1010 is available with two, three or four paths and
IP65 (NEMA 4X) wall mount or IP66 (NEMA 7) wall mount explosionproof enclosures.
Sensor
• Calibrated performance that meets custody transfer accuracy
• WideBeam® technology allows for precision flow measurement by reducing the meter's sensitivity to changes in the medium's physical properties
• TransLoc™ permanent mounting system ensures sealing and
virtually no maintenance
• Available in a wide range of sizes
• High viscosity range (up to 2800 Cst)
• ZeroMatic Path™ capability automatically corrects for zero
drift with no interruption of flow
• Completely cavity free design which eliminates any signal degrading buildup or ports to clog
• Large bi-directional flow range
• Modbus RTU RS 232/485 output available
• Dynamic Reynolds Number compensation
3/376
Gas applications
Pipelines
Siemens FI 01 · 2016
Available sizes include 4 to 24 inch (DN 100 to DN 600) with
flange ratings of ANSI Class 150, 300 and 600 for the liquid meter and ANSI Class 300 and 600 for gas.
If the installation warrants, SITRANS FUT1010 can be delivered
with a ten diameter upstream and five diameter downstream
tubes and a flow conditioner.
■ Function
• IP65 (NEMA 4X) and IP66 (NEMA 7) transmitters have integral
33 button keypads and large (128 x 240 pixel) graphic displays readable up to 12 m (40 ft) away
• Current, voltage, status alarm, frequency and RS 232 outputs
(see specification section for details)
• Analog inputs (see specification section for details)
• 1 MByte data logger with both site and data logger storage
• Standard or actual volume flow outputs
• Standard or actual totalize outputs
• Complete application and operation diagnostics, to ensure
operational integrity
• Temperature provided by non-intrusive sensor
(¾" tap available for insert temperature sensor)
• Detection of aeration or contamination
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FUT1010 (Liquid and Gas)
■ Technical specifications
Design Flow sensor
Input
Flow range (Gas)
Flow range (Liquid)
Flow sensitivity
± 36.5 m/s (± 120 f/s) for
DN 100 ... DN 200 (4" ... 8") pipes
bi-directional
± 30.5 m/s (± 100 ft/s) for
DN 250 ... DN 600 (10" ... 24")
pipes bi-directional
± 12 m/s (± 40 f/s) including zero
flow, bi-directional
0.0003 m/s (0.001 f/s) flow rate
independent
Flow temperature range
-28 ... +93 °C (-20 ... +200°F)
Analog inputs
4 x 4 ... 20 mA, (Programmable to
Density, Pressure, viscosity or
Temperature)
Status/Alarm I/O
4" ... 24" (DN 100 ... DN 600)
API 5L ERW
Temperature tap
¾"
Pressure tap
¼"
Flange class
• Liquid
150, 300, 600
• Gas
300, 600
Flange specification
• ASME B16.5
• Liquid 150, 300, 600
• Gas 300, 600
Flange facing
Raised face weld neck
Flange material
A105
Flow sensor paths
Two, three, or four
Sensor length
See diagram
Design temperature
-28 ... +93 °C (-20 ... +200 °F)
Exterior finish
Marine/offshore grade per ASTM
B117
Optional pipe sections
• 10 D upstream (with optional
flow conditioner)
• 5 D downstream
• Programmable, 4x Form C
Relays
• Clear Switch Input Totalizer Hold
Switch Input
FM and CSA
• Transmitter
N-I Class I, Div 2
S Class II, Div 2
• Sensor
I.S. Class I, II, Div 1
ATEX
Ex II (1) G [Ex ia] IIC
EX II 3 (1) G Ex nC [ia] IIC T5
CE markings
EMC 2014/30/EU
ATEX 2014/34/EU
Certificates and approvals
Flow transmitter IP65 (NEMA 4X)
Calibrated accuracy
Gas
2-path
0.5 ... 1.0 % (4” ... 6” < 0.25 %)
3-path
< 0.5 %
4-path
< 0.2 %
Flow Transmitter - IP66 (NEMA 7)
Liquid
2-path
0.5 ... 1.0 % (4” ... 6” < 0.15 %)
3-path
< 0.5 %
4-path
< 0.15 %
Repeatability
± 0.05 ... 0.1 %
Data refresh rate
5 Hz
Design
FM and CSA
• Transmitter
Ex Class I, Div 1
D-I Class II, Div 1
N-I Class I, Div 2
S Class II, Div 2
• Sensor
I.S. Class I, II, Div 1
ATEX
Ex II (1) G [Ex ia] IIC
Ex II 3 (1) G Ex nC [ia] IIC T5
Ex II 2 (1) G Ex d [ia IIC] IIB +
H2 T5
CE markings
EMC 2014/30/EU
ATEX 2014/34/EU
Design Flow transmitter
Dimensions
see SITRANS F US Clamp-on
"System info and selection guide"
Weight
see diagrams
Power supply
Power supply
3
• 4x isolated 4 ... 20 mA, programmable
• 2x 0 ... 10 V DC, programmable
• 4x Digital Pulse outputs (2x
open collector and 2x 0-5V TTL)
One each for positive flow, one
each for negative flow
• Standard VT100 RS 232,
Optional HART, BACnet
MSTP/BACnet IP, Modbus RTU
& TCP/IP, Ethernet IP,
Johnson N2
Output
Standard outputs
Nominal pipe sizes
Pipe material specification
Sensor
90 ... 240 V AC, 50 … 60 Hz,
30 VA or
9 ... 36 V DC, 12 W
Indication and operation
Data logger memory
1 MByte, programmable for all
available data variables
Display
128 x 240 pixel LCD with backlight
Keypad
33 keypad buttons with tactile
feedback
Language options
English, Spanish, German, Italian,
French
FM and CSA
I.S. Class I, Div 1
N-I Class I, Div 2
S Class II, Div 2
ATEX
Ex II 1 G Ex ia IIC T5
CE markings
EMC 2014/30/EU
PED 97/23/EEC
ATEX 2014/34/EU
Siemens FI 01 · 2016
3/377
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FUT1010 (Liquid and Gas)
■ Dimensional drawings
Sensor
Upstream tube
optional
Siemens
OD
Downstream tube
optional
ID
WT
L2
3
L1
L3
L4
Length
Liquid Flange
Class 150
Nominal O.D.
Nominal I.D.
Max operating
pressure (psi)
Mat.
Grade
Length L1
Length L2
Length L3
Length L4
mm
inch
mm
inch
mm
inch
bar
psi
101.6
4.0
114.3
4.5
102.3
4.026
19.7
285.0
B
mm
1828.8 72.0
mm
1023.6 40.3
mm
inch
mm
inch
510.5
20.1
3369.3
152.4
6.0
168.3
6.625
154.1
6.065
19.7
285.0
B
1828.8 72.0
132.65
1541.8 60.7
769.6
30.3
4146.6
203.2
8.0
219.1
8.625
202.7
7.981
19.7
285.0
B
163.25
1828.8 72.0
2026.9 79.8
1013.5 39.9
4875.5
254.0
10.0
273.1
10.75
254.5
10.02
19.7
285.0
191.95
B
2184.4 86.0
2545.1 100.2
1272.5 50.1
6008.4
304.8
12.0
323.9
12.75
304.8
12.0
19.7
236.55
285.0
B
2184.4 86.0
3048.0 120.0
1524.0 60.0
6762.8
406.4
16.0
406.4
16.0
387.4
15.25
266.25
19.7
285.0
B
2184.4 86.0
3873.5 152.5
1938.0 76.3
8002.3
457.2
18.0
457.2
18.0
438.2
315.05
17.25
19.7
285.0
B
2501.9 98.5
4381.5 172.5
2192.0 86.3
9081.8
508.0
20.0
508.0
20.0
357.55
489.0
19.25
19.7
285.0
B
2501.9 98.5
4889.5 192.5
2446.0 96.3
9843.8
609.6
24.0
609.6
24.0
387.55
590.6
23.25
19.7
285.0
B
2501.9 98.5
5905.5 232.5
2954.0 116.3
11367.8 447.55
Mat.
Grade
Length L1
Length L2
Length L3
Length L4
mm
mm
inch
inch
Length
Liquid Flange
Class 300
Nominal O.D.
Nominal I.D.
Max operating
pressure (psi)
mm
inch
mm
inch
mm
inch
bar
psi
mm
inch
mm
inch
101.6
4.0
114.3
4.5
102.3
4.026
51.0
740.0
B
1828.8 72.0
1023.6 40.3
510.5
20.1
3369.3
132.65
152.4
6.0
168.3
6.625
154.1
6.065
51.0
740.0
B
1828.8 72.0
1541.8 60.7
769.6
30.3
4146.6
163.25
203.2
8.0
219.1
8.625
202.7
7.981
51.0
740.0
B
1828.8 72.0
2026.9 79.8
1013.5 39.9
4875.5
191.95
254.0
10.0
273.1
10.75
254.5
10.020 51.0
740.0
B
2184.4 86.0
2544.1 100.2
1272.5 50.1
6008.4
236.55
304.8
12.0
323.9
12.75
304.8
12.0
51.0
740.0
B
2184.4 86.0
3048.0 120.0
1524.0 60.0
6762.8
266.25
406.4
16.0
406.4
16.0
381.0
15.0
51.0
740.0
B
2184.4 86.0
3810.0 150.0
1905.0 75.0
7905.8
311.25
457.2
18.0
457.2
18.0
428.7
16.876 51.0
740.0
B
2501.9 98.5
4287.5 168.8
2143.8 84.4
8939.5
351.95
508.0
20.0
508.0
20.0
477.9
18.814 51.0
740.0
X42
2501.9 98.5
4777.7 188.1
2390.1 94.1
9676.1
380.95
609.6
24.0
609.6
24.0
574.7
22.626 51.0
740.0
X42
2501.9 98.5
5748.0 226.3
2872.7 113.1
11129.0 438.15
Mat.
Grade
Length L1
Length L2
Length L3
Length L4
mm
inch
inch
Length
Liquid Flange
Class 600
Nominal O.D.
Nominal I.D.
Max operating
pressure (psi)
mm
inch
mm
inch
mm
inch
bar
psi
mm
mm
inch
mm
inch
101.6
4.0
114.3
4.5
102.3
4.026
96.6
1400.0 B
1828.8 72.0
1023.6 40.3
510.5
20.1
3369.3
132.65
152.4
6.0
168.3
6.625
154.1
6.065
81.0
1175.0 B
1828.8 72.0
1541.8 60.7
769.6
30.3
4146.6
163.25
203.2
8.0
219.1
8.625
193.7
7.625
102.1
1480.0 B
1828.8 72.0
1938.0 76.3
967.7
38.1
4740.9
186.65
254.0
10.0
273.1
10.75
247.7
9.75
82.8
1200.0 B
2184.4 86.0
2476.5 97.5
1239.5 48.8
5906.8
232.55
304.8
12.0
323.9
12.75
298.5
11.75
79.3
1150.0 B
2184.4 86.0
2984.5 117.5
1493.5 58.8
6668.8
262.55
406.4
16.0
406.4
16.0
373.1
14.688 82.8
1200.0 B
2184.4 86.0
3731.3 146.9
1864.4 73.4
7786.4
306.55
457.2
18.0
457.2
18.0
419.1
16.5
1250.0 B
2501.9 98.5
4191.0 165.0
2095.5 82.5
8794.8
346.25
508.0
20.0
508.0
20.0
466.8
18.376 82.8
1200.0 X42
2501.9 98.5
4668.5 183.8
2334.3 91.9
9511.0
374.45
609.6
24.0
609.6
24.0
560.4
22.064 77.6
1125.0 X42
2501.9 98.5
5603.2 220.6
2801.6 110.3
10913.1 429.65
3/378
Siemens FI 01 · 2016
86.2
inch
inch
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FUT1010 (Liquid and Gas)
Length
Gas Class 300
Nominal O.D.
Nominal I.D.
Max operating
pressure (psi)
Mat.
Grade
Length L1
Length L2
Length L3
Length L4
mm
inch
mm
inch
mm
inch
bar
psi
mm
mm
mm
inch
mm
inch
101.6
4.0
114.3
4.5
102.3
4.026
51.0
740.0
B
1828.8 72.0
152.4
6.0
168.3
6.625
154.1
6.065
51.0
740.0
B
1828.8 72.0
1023.6 40.3
510.5
20.1
3369.3
132.65
1541.8 60.7
769.6
30.3
4146.6
203.2
8.0
219.1
8.625
202.7
7.981
51.0
740.0
X42
163.25
1828.8 72.0
2026.9 79.8
1013.5 39.9
4875.5
254.0
10.0
273.1
10.75
254.5
10.020 51.0
740.0
191.95
X42
1828.8 72.0
2545.1 100.2
1272.5 50.1
5652.8
304.8
12.0
323.9
12.75
303.2
11.938 51.0
222.55
740.0
X42
1828.8 72.0
3032.8 119.4
1516.4 59.7
6384.3
406.4
16.0
406.4
16.0
381.0
15.0
251.35
51.0
740.0
X42
1981.2 78.0
3810.0 150.0
1905.0 75.0
7702.6
303.25
457.2
18.0
457.2
18.0
428.7
16.876 51.0
740.0
X42
1981.2 78.0
4287.5 168.8
2143.8 84.4
8418.8
331.45
508.0
20.0
508.0
609.6
24.0
609.6
20.0
477.9
18.814 51.0
740.0
B
1981.2 78.0
4777.7 188.1
2390.1 94.1
9155.4
360.45
24.0
574.7
22.626 51.0
740.0
B
1981.2 78.0
5748.0 226.3
2872.7 113.1
10608.3 417.65
Mat.
Grade
Length L1
Length L2
Length L3
Length L4
mm
mm
inch
mm
inch
inch
inch
Length
Gas Class 600
Nominal O.D.
Nominal I.D.
Max operating
pressure (psi)
mm
inch
mm
inch
mm
inch
bar
psi
mm
101.6
4.0
114.3
4.5
102.3
4.026
102.1
1480.0 X42
1828.8 72.0
1023.6 40.3
510.5
20.1
3369.3
132.65
152.4
6.0
168.3
6.625
154.1
6.065
96.6
1400.0 X42
1828.8 72.0
1541.8 60.7
769.9
30.3
4146.6
163.25
203.2
8.0
219.1
8.625
202.7
7.981
87.9
1275.0 X42
1828.8 72.0
2026.9 79.8
1013.5 39.9
4875.5
191.95
254.0
10.0
273.1
10.75
247.7
9.75
102.1
1480.0 X42
1981.2 78.0
2476.5 97.5
1239.5 48.8
5703.6
224.55
304.8
12.0
323.9
12.75
298.5
11.75
94.8
1375.0 X42
1981.2 78.0
2984.5 117.5
1493.5 58.8
6465.6
254.55
406.4
16.0
406.4
16.0
381.0
15.0
75.9
1100.0 X42
1981.2 78.0
3810.0 150.0
1905.0 75.0
7702.6
303.25
457.2
18.0
457.2
18.0
428.7
16.876 75.9
1100.0 X42
1981.2 78.0
4287.5 168.8
2143.8 84.4
8418.8
331.45
508.0
20.0
508.0
20.0
477.9
18.814 75.9
1100.0 X42
1981.2 78.0
4777.7 188.1
2390.1 94.1
9155.4
360.45
609.6
24.0
609.6
24.0
574.7
22.626 72.4
1050.0 X42
1981.2 78.0
5748.0 226.3
2872.7 113.1
10608.3 417.65
inch
inch
Siemens FI 01 · 2016
3/379
3
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FUT1010 (Liquid and Gas)
SITRANS FUT1010 Liquid sizing chart
3
Nominal diameter
Qmin
Qmax
Qmin
Qmax
mm
inch
[m3/h]
[m3/h]
[42 GAL BBL/h]
[42 GAL BBL/h]
100
4
14
360
85
2267
150
6
29
818
180
5146
200
8
46
1417
290
8910
250
10
67
2233
421
14045
300
12
80
3203
504
20143
400
16
103
5172
651
32532
450
18
116
6618
728
41625
500
20
124
8241
778
51836
600
24
150
12022
945
75617
SITRANS FUT1010 Gas sizing chart
SITRANS FUT1010 maximum flow rate
(MMSCFD)
[Millions of standard cubic feet per day]
Meter size and maximum velocity
4"
6"
8"
10"
12"
16"
20"
24"
Pressure
(psig)
135 ft/s
126 ft/s
117 ft/s
144 ft/s
126 ft/s
99 ft/s
81 ft/s
90 ft/s
100
8.2
17.3
27.9
54.1
67.1
83.3
107.1
174.9
200
15.5
32.9
52.9
102.7
127.6
158.2
203.4
332.3
300
23.1
49.0
78.7
152.8
189.8
235.4
302.6
494.5
400
30.9
65.5
105.3
204.4
253.9
315.0
404.8
661.5
500
39.0
82.6
132.8
257.6
320.0
396.9
510.1
833.6
600
47.3
100.1
161.0
312.4
388.0
481.2
618.5
1010.8
700
55.8
118.2
190.0
368.7
457.9
568.1
730.1
1193.1
800
64.6
136.8
219.8
426.6
529.9
657.3
844.8
1380.5
900
73.6
155.8
250.5
486.1
603.8
749.0
962.6
1573.1
1000
82.8
175.4
282.0
547.2
679.6
843.0
1083.5
1770.6
1100
92.3
195.4
314.1
609.6
757.1
939.2
1207.1
1972.7
1200
101.9
215.9
347.0
673.3
836.3
1037.4
1333.3
2178.9
SITRANS FUT1010 maximum flow rate (MMSCFD) [Millions of standard cubic feet per day]
Meter size and maximum velocity
[Minimum flow rate above which 0.2 % accuracy can be maintained]
4"
6"
8"
10"
12"
16"
20"
24"
Pressure
(psig)
1.55 ft/s
1.4 ft/s
1.3 ft/s
1.65 ft/s
1.35 ft/s
1.1 ft/s
0.85 ft/s
1 ft/s
100
0.1
0.2
0.3
0.6
0.7
0.9
1.1
1.9
200
0.2
0.4
0.6
1.2
1.4
1.8
2.1
3.7
300
0.3
0.5
0.9
1.8
2.0
2.6
3.2
5.5
400
0.4
0.7
1.2
2.3
2.7
3.5
4.2
7.4
500
0.4
0.9
1.5
3.0
3.4
4.4
5.4
9.3
600
0.5
1.1
1.8
3.6
4.2
5.3
6.5
11.2
700
0.6
1.3
2.1
4.2
4.9
6.3
7.7
13.3
800
0.7
1.5
2.4
4.9
5.7
7.3
8.9
15.3
900
0.8
1.7
2.8
5.6
6.5
8.3
10.1
17.5
1000
1.0
1.9
3.1
6.3
7.3
9.4
11.4
19.7
1100
1.1
2.2
3.5
7.0
8.1
10.4
12.7
21.9
1200
1.2
2.4
3.9
7.7
9.0
11.5
14.0
24.2
3/380
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FUT1010 (Liquid and Gas)
SITRANS FUT1010 Maximum Flow Rate
(Nm3/h x 1000)
[Thousands of normal cubic meters per hour]
DIN meter size and maximum velocity
100 mm
150 mm
200 mm
250 mm
300 mm
400 mm
500 mm
600 mm
Pressure
(barg)
41.1 m/s
38.4 m/s
35.6 m/s
43.9 m/s
38.4 m/s
30.1 m/s
24.6 m/s
27.4 m/s
10
13.5
28.7
46.1
89.5
111.2
137.9
177.2
289.6
20
26.4
55.9
89.9
174.5
216.7
268.8
345.5
564.6
30
39.8
84.4
135.6
263.2
326.9
405.5
521.2
851.8
40
53.9
114.1
183.4
355.8
441.9
548.2
704.6
1151.4
50
68.5
145.0
233.1
452.4
561.9
697.0
895.9
1464.0
60
83.7
177.2
284.9
552.9
686.7
851.9
1094.8
1789.2
70
99.5
210.7
338.7
657.2
816.3
1012.6
1301.5
2126.9
80
115.8
245.3
394.3
765.1
950.2
1178.7
1514.9
2475.8
90
132.6
280.8
451.4
875.9
1087.8
1349.4
1734.3
2834.3
100
149.7
317.1
509.7
989.1
1228.5
1523.9
1958.6
3200.8
110
167.1
353.8
568.8
1103.8
1370.9
1700.6
2185.7
3571.9
120
184.5
390.8
628.2
1218.9
1514.0
1878.0
2413.7
3944.5
3
SITRANS FUT1010 Transition Flow Rate
(Nm3/h x 1000)
[Thousands of normal cubic meters per hour]
DIN meter size and maximum velocity
Minimum flow rate above which 0.2 % accuracy can be maintained
100 mm
150 mm
200 mm
250 mm
300 mm
400 mm
500 mm
600 mm
Pressure
(barg)
0.47 m/s
0.42 m/s
0.39 m/s
0.50 m/s
0.41 m/s
0.33 m/s
0.25 m/s
0.30 m/s
10
0.2
0.3
0.5
1.0
1.2
1.5
1.9
3.2
20
0.3
0.6
1.0
2.0
2.3
3.0
3.6
6.3
30
0.5
0.9
1.5
3.0
3.5
4.5
5.5
9.5
40
0.6
1.3
2.0
4.1
4.7
6.1
7.4
12.8
50
0.8
1.6
2.6
5.2
6.0
7.7
9.4
16.3
60
1.0
2.0
3.2
6.3
7.4
9.5
11.5
19.9
70
1.1
2.3
3.8
7.5
8.7
11.3
13.7
23.6
80
1.3
2.7
4.4
8.8
10.2
13.1
15.9
27.5
90
1.5
3.1
5.0
10.0
11.7
15.0
18.2
31.5
100
1.7
3.5
5.7
11.3
13.2
16.9
20.6
35.6
110
1.9
3.9
6.3
12.6
14.7
18.9
22.9
39.7
120
2.1
4.3
7.0
14.0
16.2
20.9
25.3
43.8
Siemens FI 01 · 2016
3/381
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FUT1010 (Liquid and Gas)
Selection and Ordering data
SITRANS FUT1010 (Liquid)
Article No.
Order Code
7 ME3 6 2 7 - 7 7 77 7 - 0 7 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
3
Transmitter type
No Transmitter
IP65 NEMA 4X (2 path)
IP65 NEMA 4X (2 path) with optional communications
IP65 NEMA 4X (3 or 4 path)
IP65 NEMA 4X (3 or 4 path) with optional communications
IP66 NEMA 7 wall mount/explosionproof (2 Path)
P66 NEMA 7 wall mount/explosionproof (2 Path) with optional communications
P66 NEMA 7 wall mount/explosionproof (3 or 4 Path)
P66 NEMA 7 wall mount/explosionproof (3 or 4 Path) Iwith optional communications
Input power
90 ... 240 V AC
9 ... 36 V DC
Number of ultrasonic paths
2 path
3 path
4 path
Pipe size
DN 100 (4") (Dual Path only)
DN 150 (6")(Dual Path only)
DN 200 (8")
DN 250 (10")
DN 300 (12")
DN 400 (16")
DN 450 (18")
DN 500 (20")
DN 600 (24")
Flange rating
Class 150 (Raised Face)
Class 300 (Raised Face)
Class 600 (Raised Face)
Upstream/downstream meter run
None
10 pipe diameter upstream Tube only
10 pipe diameter upstream Tube with flow conditioner
5 pipe diameter downstream tube only
10D up and 5D downstream tubes
10D up and 5D downstream tubes with flow conditioner
Liquid type range (select closest match)
Water
Multiple Crude Oils
Light Crude only
Heavy Crude only
Multiple Finished Products
Gasolines Only
Kerosene
Jet Fuel
Diesel
Multiple Fuel Oils
Heavy Fuel Oils
Liquified Gases
Liquid temperature range
-28 ... +65 °C (-20 ... +150 °F )
1 ... 93 °C (30 ... 200 °F)
Transmitter and sensor approval
FM/CSA, CE
ATEX and PED, CE, C-TICK
3/382
Siemens FI 01 · 2016
0
1
2
3
4
5
6
7
8
1
2
B
C
D
A
B
C
D
E
F
G
H
J
0
1
2
0
1
2
3
4
5
A
B
C
D
E
F
G
H
J
K
L
M
A
B
1
2
777
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FUT1010 (Liquid and Gas)
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Article No. and specify Order code(s).
Cable assembly for flow sensor
(add one K.. per flow path)
• Cable and termination for one sensor path
(see "Sensor cable chart for options")
K..
• Termination for user supplied cable
T01
Cable assembly for temperature sensor (only 1 required)
• Cable and termination for temperature sensor (see
"Transducer cable chart for options").
R..
• Termination for user supplied RTD cable
T31
• Cable gland kit
T51
3
Nace Certification
• Nace, Spool only
C10
• Nace, W/10D upstream
C11
• Nace, W/10D upstream, cond
C12
• Nace, W/5D downstream
C13
• Nace, W/10D up, 5D dn
C14
• Nace, W/10D up, cond, 5D dn
C15
Standard Cal: Oil (2 cst), Forward flow direction,
6 points, 6 verification points, Range 2 ... 20 ft/sec,
Lab pressure and temperature
• Calibration, 100 DN (4 inch)
• Calibration, 150 DN (6 inch)
• Calibration, 200 DN (8 inch)
• Calibration, 250 DN (10 inch)
• Calibration, 300 DN (12 inch)
• Calibration, 400 DN (16 inch)
• Calibration, 450 DN (18 inch)
• Calibration, 500 DN (20 inch)
• Calibration, 600 DN (24 inch)
• Calibration, Other contact factory for quote
D10
D11
D12
D13
D14
D15
D16
D17
D18
Y28
Tag name plate
• Stainless steel tags with 3.2 mm (0.13 inch) character
size (68 characters max.)
Y19
Selection and Ordering data
Operating Instructions for
SITRANS FUT1010 (Liquid)
English NEMA 4X wall mount& NEMA 7 wall
mount explosionproof
German NEMA 4X wall mount & NEMA 7 wall
mount explosionproof
Article No.
A5E02639184
A5E03086468
This device is shipped with a Quick Start Guide and a CD containing
further SITRANS F literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Siemens FI 01 · 2016
3/383
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FUT1010 (Liquid and Gas)
Selection and Ordering data
SITRANS FUT1010 (Gas)
Article No.
Order Code
7 ME3 6 3 7 - 7 777 7 - 0 7 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
3
Transmitter type
No meter
IP65 NEMA 4X (2 path)
IP65 NEMA 4X (2 path) with Modbus
IP65 NEMA 4X (3 or 4 path)
IP65 NEMA 4X (3 or 4 path) with Modbus
IP66 NEMA 7 wall mount flame/explosion proof (2 Path)
IP66 NEMA 7 wall mount flame/explosion proof (2 Path) with Modbus
IP66 NEMA 7 wall mount flame/explosion proof (3 or 4 Path)
IP66 NEMA 7 wall mount flame/explosion proof (3 or 4 Path) with Modbus
Input power
90 ... 240 V AC
9 ... 36 V DC
Number of ultrasonic paths
2 path (standard enclosure material)
3 path (standard material)
4 path (standard material)
Pipe size
DN 100 (4") (Dual Path only)
DN 150 (6")(Dual Path only)
DN 200 (8")
DN 250 (10")
DN 300 (12")
DN 400 (16")
DN 450 (18")
DN 500 (20")
DN 600 (24")
Flange rating
Class 300 (Raised Face)
Class 600 (Raised Face)
Upstream/downstream meter run
None
10 pipe diameter upstream Tube only
10 pipe diameter upstream Tube with flow conditioner
5 pipe diameter downstream tube only
10D up and 5D downstream tubes
10D up and 5D downstream tubes with flow conditioner
Gas type range (select closest match)
Natural Gas (mostly CH4)
Process Gases (N2, O2, CO, Ar)
Helium
Hydrogen
Gas temperature range
-28 ... +65 °C (-20 ... +150 °F )
1 ... 93 °C (30 ... 200 °F)
Transmitter and sensor approval
FM/CSA, CE
ATEX and PED, CE, C-TICK
3/384
Siemens FI 01 · 2016
0
1
2
3
4
5
6
7
8
1
2
B
C
D
A
B
C
D
E
F
G
H
J
1
2
0
1
2
3
4
5
A
B
C
D
A
B
1
2
777
© Siemens AG 2016
Flow Measurement
SITRANS F US Clamp-on
SITRANS FUT1010 (Liquid and Gas)
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Article No. and specify Order code(s).
Cable assembly for flow sensor
(Add one K.. per flow path)
• Cable and termination for one sensor path (see "Transducer cable chart for options")
K..
• Termination for user supplied cable
T01
Cable assembly for temperature sensor (only 1 required)
• Cable and termination for temperature sensor
(see "Transducer cable chart for options").
R..
• Termination for user supplied RTD cable
T31
3
Nace Certification
• Nace, Spool only
C10
• Nace, W/10D upstream
C11
• Nace, W/10D upstream, cond
C12
• Nace, W/5D downstream
C13
• Nace, W/10D up, 5D dn
C14
• Nace, W/10D up, cond, 5D dn
C15
Standard Cal: Nat Gas, Forward flow direction,
7 points, 2 verification points, Range 10 ... 100 ft/sec,
Lab pressure and temperature
• Calibration, 100 DN (4 inch)
• Calibration, 150 DN (6 inch)
• Calibration, 200 DN (8 inch)
• Calibration, 250 DN (10 inch)
• Calibration, 300 DN (12 inch)
• Calibration, 400 DN (16 inch)
• Calibration, 450 DN (18 inch)
• Calibration, 500 DN (20 inch)
• Calibration, 600 DN (24 inch)
• Calibration, Other contact factory for quote
D10
D11
D12
D13
D14
D15
D16
D17
D18
Y28
Tag name plate
• Stainless steel tags with 3.2 mm (0.13 inch) character
size (68 characters max.)
Y19
Selection and Ordering data
Operating Instructions for
SITRANS FUT1010 (Gas)
English NEMA 4X wall mount & NEMA 7 wall
mount explosionproof
German NEMA 4X wall mount & NEMA 7 wall
mount explosionproof
Article No.
A5E02639185
A5E03086485
This device is shipped with a Quick Start Guide and a CD containing
further SITRANS F literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Siemens FI 01 · 2016