Download

Two-circuit Limit Switch/Long-life Two-circuit Limit Switch
WL/WLM
CSM_WL_WLM_DS_E_17_1
Wide Range of Two-circuit
Switches; Select One for the
Operating Environment/Application
• A wide selection of models are available, including the
overtravel models with greater OT, indicator-equipped
models for checking operation, low-temperature
models,
heat-resistant models, and corrosion-proof models.
• Microload models are added to the product lineup.
• Approved standards: EC/IEC, UL, CSA, CCC (Chinese
standard).
Contact your OMRON representative for information on
approved models.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on page 39 to 42 and
Safety Precautions for All Limit Switches.
Features
Standard Models
Features Common to All Models
Many Variations in Standard Limit Switches
DPDB Operation
A Wide Range of Models
The double-pole, double-break structure ensures circuit braking.
The WL Series provides a complete range of Limit Switches with a
long history of meeting user needs. Select environment-resistant
specifications, actuators for essentially any workpiece, operating
sensitivity matched to the workpiece, operation indicators to aid
operation and maintenance, and various wiring specifications.
Za
(NO)4
3(NO)
(NC)1
2(NC)
1
4
2
3
Load
Load
Environment-resistant Models
Select from Six Types of Environment Resistance
Degree of Protection; IP67
The series includes Airtight Switches, Hermetic Switches, Heatresistant Switches, Low-temperature Switches, Corrosion-proof
switches, and Weather-proof Switches. Select the one required by the
onsite environment.
O-rings, cover seals, and other measures provide a water-proof, dripproof structure (IP67).
Spatter-prevention Models
Approved Standards to Aid Export Machines
Various WL/WLM switches are approved by UL, CSA, TÜV, EN/IEC,
and CCC making them ideal for export machines.
Excellent Performance on Arc Welding Lines or Sites with
Spattering Cutting Powder
High-precision Models Available in All Switch Types;
Ideal for Position Control
Ideal for Welding Sites
High-precision models achieve a very small movement to operation
(approx. 5°) and a repeat accuracy that is twice that of basic models.
Stainless steel and resins that resist adhesion of spatters are used to
prevent troubles caused by zinc powder generated during welding.
Long-life Models
Mechanical Endurance of 30 Million Operations
Long-life Models for High-frequency Applications
Long life has been achieved by increasing the resistance to friction
and creating better sliding properties in the head mechanism. Greater
visibility is provided when setting with a fluorescent display for setting
the stroke.
Operation Indicators for Easier Daily
Inspections*
Confirm operation with a neon lamp or LED for
easier startup confirmations and maintenance.
* Operation indicators are provided on Indicatorequipped switches, Spatter-prevention Basic
Switches, and Long-life Basic Switches.
Operation
indicator
Models with Connectors to Reduce Wiring
Reduce wiring with one-touch connection. Models with direct-wired
and prewired connectors that make Switch replacement easier are
also available.
1
WL/WLM
Product Configuration
Selection by Purpose
Standard
●Standard-load
Switches
WL@
●Microload
Switches
WL01@
Selection Points
Effective for switching loads of 0.1 A, 125 VAC/30
VDC.
●Basic Switches
WLC@
●Overtravel Switches
●High-precision
Switches
WLGCA2
●Protective
WLCA32-@
Generalpurpose
Operation indicators
Selection Points
· Effective for confirming workpieces
passing by on a conveyor or for
confirming operation in dark
locations.
· For standard models, add -LE or -LD.
(Operation indicators cannot be used
with some environment-resistant
Sensor I/O connectors
Selection Points
Effective for reducing wiring work,
making maintenance easier, and
preventing wiring mistakes.
WL Series
Environment-resistant
Selection Points
Enable selection according to the
operating environment: water, oil,
chemicals, high/low temperatures, etc.
Spatter-prevention
Selection Points
Effective for welding sites or spattering
cutting powder.
WLM Series
Long-life
Selection Points
With high mechanical durability of 30
million operations, effective for
high-frequency operation.
❍General-purpose
Switches
WLH@
❍High-sensitivity
Switches
WLG@
❍90° Operation
Switches
WL@-2
WL@-2N
Selection Points
Effective if the overall
movement is 80° or 90°
when dog angle or
deflection is absorbed.
Selection Points
Provide twice the repeat accuracy as Basic Switches.
Effective for positioning in machine tools.
Selection Points
Effective for protecting the operating status.
●Indicator-equipped Switches: Neon lamps
WL@-@LE
●Indicator-equipped Switches: Light emitting diodes (LED)
WL@-@LD
●Direct-wired Switches
WL@-@LDK@
●Pre-wired Switches
WL@-@LD-M1@
WL@-@LD-AGJ@/-DGJ@
WL@-@LD-DK1EJ@
●Airtight Switches
WL@-55
●Hermetic Switches
WL@-139
WL@-140
WL@-141
WL@-145
WL@-RP40
WL@-RP60
●Heat-resistant Switches
WL@-TH
●Low-temperature Switches
WL@-TC
●Corrosion-proof Switches
WL@-RP
●Weather-proof Switches
WL@-P1
●Basic Switches
WLCA2-@S
●Microload Switches
WL01@-@S
●Overtravel Switches
●High-precision Switches
WLGCA2-@S
●Basic Switches
WLMCA2@
●Overtravel Switches
●High-precision Switches
WLMGCA2@
❍General-purpose Switches
WLH2-@S
❍High-sensitivity Switches
WLG2-@S
❍General-purpose Switches
WLMH2@
❍High-sensitivity Switches
WLMG2@
2
WL/WLM
Tables of Models
General-purpose Switches
Spatter-prevention Switches
Long-life Switches
Heads (Roller levers only)
Type
General
purpose
Features
Model
Total travel (TT)
• With a Roller Lever
Basic
Head specifications
45°
45°
WLC@
Generalpurpose
Overtravel
High-sensitivity
Overtravel
• Overtravel is large, making
setting the dog easier.
• Mounting is compatible with
WLH2.
WLH@
• Operation is highly sensitive
with only 10° pretravel.
• Overtravel is large, making
setting the dog easier.
• Mounting is compatible with
WLG2.
WLG@
• Overtravel is large, making
setting the dog easier.
• Mounting is compatible
with WLCA2-2.
WL@-2
Overtravel,
90° operation
WL@-2N
High-precision
Maintained
WLGCA2
• Repeat accuracy is twice that
basic models.
• Operation is highly sensitive
with only 5° pretravel.
• Ideal for positioning, e.g.,
WLCA32-@
• When the dog throws the lever, the output is reversed
and the reversed output is
held even after the dog
passed. The original status
is returned to only after the
dog passed.
80°
80°
90°
45°
One-side
operation
Head
mounting
Possible *1
(Except for
long-life
models.)
Any of
4 directions
Spatter
prevention
Long-life
Model
Model
WLCA2-@S
WLMCA2@
Not possible Any of
*2
4 directions
WLH2-@S
WLH2@
Not possible Any of
*2
4 directions
WLG2-@S
WLMG2@
80°
80°
90°
Not possible Any of
*2
4 directions
—
—
Any of
4 directions
WLGCA2-@S
WLMGCA2@
Any of
4 directions
—
—
Possible *1
Either of
2 directions
Possible *1
—
45°
90°
*1. One-side operation means that three operational directions can be selected electrically, according to the change in direction of the operating plunger. The operating
plunger is set for operation on both sides before delivery.
*2. Those models for which one-side operation is impossible can only operate on both sides.
Connectors and Conduits
Wiring type
Direct-wired connector
Pre-wired connector
Conduit (screw terminal)
General-purpose
Model
WL@-@LDK@
WL@-@LD-M1@
WL@-@LD-@GJ@
WL@-@LD-DK1EJ@
WL@-@
WL@-@G1@
WL@-@G@
WL@-@Y@
WL@-@TS@
• SC-2F/-4F Connector built-in
Spatter-prevention
Model
—
Long-life
Model
WLM@-LDK@
• XS2H-series Pre-wired Connector builtin
WL@-@S-M1@J-1
WL@-@S-DGJS03
WLM@-LD-M1J
WLM@-LD-@GJ@
Connector/conduit specifications
• G1/2 with no ground terminal
• G1/2 with ground terminal
• Pg13.5 with ground terminal
• M20 with ground terminal
• 1/2 14NPT with ground terminal
—
WLM@-LD
—
—
—
—
3
WL/WLM
Environment-resistant Switches
Type
Airtight seal
Item
Model
Application
Uses the W-10FB3-55 Airtight Built-in Switch.
WL@-55
WL@-139
WL@-140
Environment-resistant
Environment-resistant construction
Note: Use the SC Connector for the conduit opening.
Refer to page 25 for information on the environment-resistant construction of Switches with Hermetic Seals.
WL@-RP40
WL@-RP60
Low-temperature * WL@-TC
Can be used at a temperature of –40°C (operating
temperature range: –40 to
40°C), but cannot withstand icing.
• Uses a general-purpose built-in switch.
• Silicone rubber is used for rubber parts such as
the O-ring, gasket, etc.
Heat-resistant *
Can be used in temperatures of 120°C (operating
temperature range: 5 to
120°C).
• Uses a special built-in switch made from heatresistant resin.
• Silicone rubber is used for rubber parts such as
the O-ring, gasket etc.
Corrosion-proof
Weather-proof *
WL@-TH
WL@-RP
WL@-P1
For use in locations subject to corrosive gases and
chemicals.
For use in parking lots and
other outdoor locations.
Note: Models can be produced
using standard
actuators.
All models except the lowtemperature and heat-resistant models
For uses in locations subject to cutting oil or water
Hermetic seal
WL@-141
(Molded terminals/
WL@-145
Anti-coolant)
Applicable models
All models except the lowtemperature and heat-resistant models
• Diecast parts, such as the switch box, are made
of corrosion-proof aluminum.
• Rubber sealing parts are made of fluorine
rubber which aids in resisting oil, chemicals and
adverse weather conditions.
• Exposed nuts and screws (except the actuator
section) are made of stainless steel.
• Moving and rotary parts such as rollers are
made of sintered stainless steel or stainless
steel.
• The Head, box, and cover are yellow.
• Rubber parts are made from silicone rubber,
which has a high-tolerance to deterioration over
time and changes in temperature.
• Rollers are made of stainless steel to improve
corrosion resistance.
• Exposed nuts and screws are made of stainless
steel.
Note: Models can be produced
using standard
actuators. Only the
WLCA2, WLGCA2, or
WLH2 can be produced
for the WL@-141 and
WL@-145.
All models except airtight
seal, hermetic seal, heatresistant, corrosion-proof,
and indicator-equipped
models
All models except airtight
seal, hermetic seal, heatresistant, corrosion-proof,
and indicator-equipped, nylon roller (WLCA2-26N),
seal roller models, and resin rod (WLNJ-2) models
All models except overtravel (90° operation), fork lever lock (WLCA32-41 to 43), low-temperature, heatresistant, and indicatorequipped models
Only basic (WLCA2/CA12/
CL), general-purpose overtravel (WLH2/H12/HL) and
high-sensitivity overtravel
(WLG2/G12/GL) models
(excluding heat-resistant
models).
* Weather Resistance, Cold Resistance, and Heat Resistance
Silicon rubber is used to increase resistance to weather, cold, and heat. Silicon rubber, however, can generate silicon gas. (This can occur at room temperature, but
the amount of silicon gas generated increases at higher temperatures.) Silicon gas will react as a result of arc energy and form silicon oxide (SiO2). If silicon oxide
accumulates on the contacts, contact interference can occur and can interfere with the device. Before using a Switch, test it under actual application conditions
(including the environment and operating frequency) to confirm that no problems will occur in actual.
4
WL/WLM
Selection Guide
With the WL Series, OMRON will combine the switch, Actuator, and wiring method required to build the ideal switch for
your application.
The WL Series consists of four basic types: General-purpose, Environment-resistant, Spatter-prevention, and Long-life Switches.
WLCA2 Switches can be used for the most common applications.
According to Operating Environment
Ambient operating temperature
Environment
−10°C
+80°C
Models
WL@
Normal
WLM@
Water-resistant to IP67.
High-temperature
WL@-TH
Heat-resistant
Switches *1
WL@-TC
Low-temperature
Switches *1
WL@-P1
Weather-proof
Switches *1
WL@-RP
Corrosion-proof
Switches *1
Uses an airtight built-in switch.
WL@-55
Airtight Switches *1
Cables attached. Uses a general-purpose built-in switch.
The case cover and conduit opening are molded from epoxy
resin to increase the seal. The cover cannot be removed.
WL@-139
Hermetic, Molded-terminal
Switches *1, *2
To increase heat resistance, the rubber material (silicon rubber)
and the material of the built-in switch have been changed.
−40°C
+40°C
Low-temperature
To increase resistance to cold, silicon rubber and other
measures are used.
Chemicals and oil
Water drops and mist
Constant water
drops and mist
General-purpose
Switches
Long-life Switches
+120°C
+5°C
Outdoors
Operating environment
Key specifications
Rubber parts are made from silicone rubber, which has a
high-tolerance to deterioration over time and changes in temperature.
Rollers are made of stainless steel to improve corrosion resistance.
Exposed nuts and screws are made of stainless steel.
Corrosion-proof aluminum diecast has been used for the
housing, fluorine rubber has been used for rubber parts, and
stainless steel has been used for screws and nuts (except for
actuator) to increase resistance to oils, chemicals, and weather.
Cables attached. Uses an airtight built-in switch.
The case cover and box interior are molded from epoxy resin to
increase the seal. The cover cannot be removed.
The SC connector can be removed, so it is possible to use
flexible conduits for the cable.
Cables attached. Uses an airtight built-in switch.
The cover screws, case cover, box interior, and conduit opening
are molded from epoxy resin to increase the seal.
(The cover cannot be removed.)
WL@-RP40
Hermetic, Molded-terminal
Switches *1, *2
WL@-140
Hermetic, Molded-terminal
Switches *1, *2
Constant water
drops or splattering
cutting powder
Cables attached. Uses an airtight built-in switch.
The cover screws, case cover, box interior, conduit opening, box
head, and head screws are molded from epoxy resin to increase
the seal. (The cover cannot be removed.)
The Head opening is protected from cutting powder.
-141: The Head section is molded from epoxy resin;
Head direction cannot be changed.
-145: The Head section is molded from epoxy resin;
Head can be in any of 4 directions.
Coolant
Cables attached. Uses an airtight built-in switch.
WL@-RP60
The case cover, box interior, conduit opening, and head screws
Hermetic, Molded-terminal
are molded from epoxy resin to increase the seal. (The cover
cannot be removed.) Rubber parts are made from fluorine rubber Switches *1, *2
to increase resistance to coolant.
Spattering from
welding
To prevent spatter during welding, a heat-resistant resin is used
for the indicator cover and screws and rollers are all made from
stainless steel.
WL@-141, -145
Hermetic, Molded-terminal
Switches *1, *2
(Only the WLCA2, WLG2, WLGCA2,
and WLH2 can be produced.)
WL@-S
Spatter-prevention
Switches
*1. Not all functions can be combined with environment-resistant switches. Refer to the applicable models on the previous page.
*2. Refer to page 25 for information on the construction of Hermetic Switches.
5
WL/WLM
According to Application Conditions
Conditions
Models
Switching standard
loads
10 A at 125,250, or 500 VAC
0.8 A at 125 VDC
0.4 A at 250 VDC
WL@
WL@-S
WLM@
General-purpose Switches
Spatter-prevention Switches
Long-life Switches
Switching
microloads
0.1 A at 125 VAC, resistive load
0.1 A at 30 VDC, resistive load
WL01@
WL01@-S
General-purpose Microload Switches
Spatter-prevention Microload Switches
Normal durability
Mechanical: 15 million operation min.
(10 million operation min. for overtravel
general-purpose or high-sensitivity models or
flexible rod models)
WL@
WL@-S
General-purpose Switches
Spatter-prevention Switches
Long-life
Mechanical: 30 million operation min.
WLM@
Long-life Switches
Load
Durability
Key specifications
According to Ease of Installation and Maintenance
Operation indicator
Conditions
Daily inspections
and maintenance
checks
Wiring specification
Screw tightening
and installation
One-touch
connector
attachment
Key specifications
Models
Switching light-ON between operating/not
operating. (Switching not possible for models
with molded terminals.)
Neon lamp
125 to 250 VAC
WL@-LE
General-purpose, Indicator-equipped (Neon Lamp) Switches
WL@-LES
Spatter-prevention, Indicator-equipped (Neon Lamp) Switches
Switching light-ON between operating/not
operating. (Switching not possible for models
with molded terminals.)
LED
10 to 115 VAC/DC
WL@-LD
General-purpose, Indicator-equipped (LED) Switches
WL@-LDS
Spatter-prevention, Indicator-equipped (LED) Switches
Screw terminals. No ground terminal.
Conduit size: G1/2
WL@
WLM@
General-purpose Switches
Long-life Switches
Screw terminals. Ground terminal.
Conduit size: 4 sizes
WL@
General-purpose Switches
Direct-wired connector, 2-conductor.
Greatly reduces wiring work.
Water-proof to IP67.
WL@-@LDK13
General-purpose, Direct-wired Connector Switches
WLM@-LDK13
Long-life, Direct-wired Connector Switches
Direct-wired connector, 4-conductor.
Greatly reduces wiring work.
Water-proof to IP67.
WL@-@LDK43
General-purpose, Direct-wired Connector Switches
WLM@-LDK43
Long-life, Direct-wired Connector Switches
Pre-wired connector, 2-conductor.
Greatly reduces wiring work.
Water-proof to IP67.
WL@-@LD-M1J
General-purpose, Pre-wired Connector Switches
WL@-@S-M1J-1
Spatter-prevention, Pre-wired Connector Switches
WLM@-LD-M1J
Long-life, Pre-wired Connector Switches
Pre-wired connector, 4-conductor.
Greatly reduces wiring work.
Water-proof to IP67.
WL@-@LD-@GJO3
General-purpose, Pre-wired Connector Switches
WL@-@S-@GJSO3
Spatter-prevention, Pre-wired Connector Switches
WLM@-LD-@GJO3
Long-life, Pre-wired Connector Switches
Connector
attachment in
control and relay
boxes
6
WL/WLM
According to Form of Operation
Detection object
Key specifications
TT (total travel)
45°
Models
PT (pretravel)
45°
15°
WLCA2
WLCA2-@S
WLMCA2
General-purpose Switches
Spatter-prevention Switches
Long-life Switches
15°
WLH2
WLH2-@S
WLMH2
General-purpose Switches
Spatter-prevention Switches
Long-life Switches
WLG2
WLG2-@S
WLMG2
General-purpose Switches
Spatter-prevention Switches
Long-life Switches
WLCA2-2
WLCA2-2N
General-purpose Switches
General-purpose Switches
Operation angles
General
80°
80°
80°
80°
Passing dogs
Passing dogs,
high sensitivity
10°
WLCA2-2
90°
25°
90°
WLCA2-2N
20°
Passing dogs
45°
5°
45°
High precision
R38
Short lever
One-Horizontal operation possible.
(WLCA@ only)
● Head mounts in any of 4 directions.
● Medium lever
● One-Horizontal operation possible.
(WLCA@ only)
● Head mounts in any of 4 directions.
● Long lever
● One-Horizontal operation possible.
(WLCA@ only)
● Head mounts in any of 4 directions.
● One-Horizontal operation possible.
(WLCA@ only)
● Head mounts in any of 4 directions.
●
●
Dogs and
workpieces
(Mounts in any of
4 directions)
R50
R63
R25 to 89
Adjustable between
dog and lever
25 to 140
Actuators
Dogs or workpieces
with large
deflection
Round-trip
operation of
passing dogs
WLGCA2
General-purpose Switches
WLGCA2-@S Spatter-prevention Switches
WLMGCA2 Long-life Switches
WL@2
WL@2-@S
WLM@2
Roller Lever Actuators
Roller Lever Actuators
Roller Lever Actuators
WL@2-7
Roller Lever Actuators
WL@2-8
Roller Lever Actuators
WL@12
Adjustable Roller Lever Actuators
One-Horizontal operation possible.
WL@L
(WLCL only)
● Head mounts in any of 4 directions.
Adjustable Rod Lever Actuators
One-Horizontal operation not
possible.
WLHAL4
● Head mounts in any of 4 directions.
Adjustable Rod Lever Actuator
One-Horizontal operation not
possible.
WLHAL5
● Head mounts in any of 4 directions.
Rod Spring Lever Actuator
●
350 to 380
●
427.5
●
●
Head mounts in any of 4 directions. WLCA32-41
Fork Lever Lock Actuator
●
Head mounts in any of 4 directions. WLCA32-42
Fork Lever Lock Actuator
●
Head mounts in any of 4 directions. WLCA32-43
Fork Lever Lock Actuator
●
Head mounts in any of 4 directions. WLCA32-44
Fork Lever Lock Actuator
WLD
●
Cams or
workpieces with
vertical movement
Head mounts in any of 4 directions. WLSD
WLD3
●
Head mounts in any of 4 directions. WLSD3
●
Available in sealed models.
(WLD28@)
Top Plunger Actuator
Horizontal Plunger Actuator
Top-ball Plunger Actuator
Horizontal-ball Plunger Actuator
WLD2
WLD28
Top-roller Plunger Actuator
Sealed Top-roller Plunger Actuator
WLSD2
Horizontal-roller Plunger Actuator
7
WL/WLM
Application Examples
Positioning on Production Lines
High-precision Positioning of Machine Tools
Positioning on Suspended Conveyors
Pallet Detection in Arc Welding Lines
Multilevel Car Parking Towers
Limit Detection is Transport Systems
8
WL/WLM
Model Number Structure
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
General-purpose and Environment-resistant Switches
WL @ @-@ @ @ @ @ @ @ @
(1) (2) (3) (4) (5) (6) (7) (8) (9)(10)
(1) Electrical Rating
Blank Standard load
01
Microload
Note: Dimensions are the same as the standard
models.
(3) Environment-resistant Model
Specifications
Blank Standard
RP Corrosion-proof *1
P1
Weather-proof *1
Note: Dimensions are the same as the standard
models.
*1. Refer to page 4 for applicable models.
(4) Built-in Switch Type
Blank Standard
55
Hermetically sealed *1
Note: Dimensions are the same as the standard
models.
*1. Refer to page 4 for applicable models.
(5) Temperature Specifications
Blank Standard: –10°C to +80°C
TH Heat-resistant: +5°C to +120°C *1
TC Low-temperature: –40°C to +40°C *1
Note: Dimensions are the same as the standard
models.
*1. Refer to page 4 for applicable models.
(7) Conduit Size, Ground Terminal
Specifications *2
Blank
G1
G
Y
TS
G1/2 without ground terminal
G1/2 with ground terminal
Pg13.5 with ground terminal
M20 with ground terminal
1/2-14NPT with ground terminal
Note: Dimensions are the same as the standard
models.
*2. Models with ground terminals are approved by
EN/IEC (CE marking).
(2) Actuator and Head Specifications
Symbol
CA2
CA2-7
CA2-8
H2
G2
CA2-2
CA2-2N
GCA2
CA12
H12
G12
CA12-2
CA12-2N
CL
HL
HAL4
GL
CL-2
CL-2N
HAL5
CA32-41
CA32-42
CA32-43
D
D2
D28
D3
SD
SD2
SD3
NJ
NJ-30
NJ-2
NJ-S2
Actuator type
Roller lever: Standard model R38
Roller lever: Standard model R50
Roller lever: Standard model R63
Roller lever: General-purpose overtravel model, 80°
Roller lever: High-sensitivity overtravel, 80°
Roller lever: Overtravel, 90°
Roller lever: Overtravel, 90°
Roller lever: High-precision R38
Adjustable roller lever: Standard
Adjustable roller lever: General-purpose overtravel model, 80°
Adjustable roller lever: High-sensitivity overtravel, 80°
Adjustable roller lever: Overtravel, 90°
Adjustable roller lever: Overtravel, 90°
Adjustable rod lever: Standard, 25 to 140 mm
Adjustable rod lever: General-purpose overtravel model, 80°, 25 to 140 mm
Adjustable rod lever: General-purpose overtravel model, 80°, 350 to 380 mm
Adjustable rod lever: High-sensitivity overtravel, 80°, 25 to 140 mm
Adjustable rod lever: Overtravel, 90°, 25 to 140 mm
Adjustable rod lever: Overtravel, 90°, 25 to 140 mm
Rod spring lever: General-purpose overtravel model, 80°
Fork lever lock: Maintained, WL-5A100
Fork lever lock: Maintained, WL-5A102
Fork lever lock: Maintained, WL-5A104
Plunger: Top plunger
Plunger: Top-roller plunger
Plunger: Sealed top-roller plunger
Plunger: Top-ball plunger
Plunger: Horizontal plunger
Plunger: Horizontal-roller plunger
Plunger: Horizontal-ball plunger
Flexible rod: Coil spring
Flexible rod: Coil spring, multi-wire
Flexible rod: Coil spring, resin rod
Flexible rod: Steel wire
(6) Hermetic Model Specifications
Blank No cables or molding
General-purpose built-in switch with cables attached and mold139
ed conduit opening and cover (cover cannot be removed). *
Airtight built-in switch with cables attached and molded conduit open140
ing, cover, and box interior cover screws (cover cannot be removed). *
Airtight built-in switch with cables attached and molded conduit opening, cover, head, box interior, cover screws, and
141 head screws (cover cannot be removed, Head direction cannot be changed). The Head opening is created to protect it
from cutting powder. *
Airtight built-in switch with cables attached and molded conduit
opening, cover, box interior, and cover screws (cover cannot be
145
removed, Head can be mounted in any of 4 directions). The
Head opening is created to protect it from cutting powder. *
Airtight built-in switch with cables attached and molded cover and
box interior (cover cannot be removed, Head direction can be
RP40
changed). SC Connector can be removed, so it is possible to use
flexible conduits for the cable. *
Airtight built-in switch with cables attached, fluorine rubber used,
RP60 and molded conduit opening, cover, and box interior (cover cannot
be removed, Head direction cannot be changed). *
Switch without lever
WLRCA2
WLRCA2
WLRCA2
WLRH2
WLRG2
WLRCA2-2
WLRCA2-2N
WLRGCA2
WLRCA2
WLRH2
WLRG2
WLRCA2-2
WLRCA2-2N
WLRCL
WLRH2
WLRH2
WLRG2
WLRCA2-2
WLRCA2-2N
WLRH2
WLRCA32
WLRCA32
WLRCA32
—
—
—
—
—
—
—
—
—
—
—
(8) Indicator Type
Symbol
Element
Blank No indicator
LE
Neon lamp
LD
LED
Voltage
Leakage current
125 to 250 VAC
Approx. 0.6 to 1.9 mA
115 VAC/VDC
Approx. 0.5 mA
10 to 24 VAC/VDC Approx. 0.4 mA
Note: Dimensions are the same for both LE and LD models.
(9) Indicator Wiring
2
3
NC connection: Light-ON when operating
NO connection: Light-ON when not operating
Note: Include the indicator wiring specification only when a (6) hermetic seal
and (8) operation indicator have been selected.
(10) Lever Type
Blank
A
Standard lever
Double nut lever
* Refer to page 4 for applicable models.
9
WL/WLM
Direct-wired Connector
General-purpose Switches
Pre-wired Connector
Sensor I/O Connector Switches
WL @ @-@ LD @
(1) (2) (3) (4) (5)
(1) Electrical Rating
Blank
01
Standard load
Microload
(4) Indicator Type
LD
LED, 10 to 115 VAC/DC
Note: Dimensions are the same as the standard models.
(5) Wiring Specifications
(2) Actuator Type
CA2
GCA2
H2
G2
D2
D28
Roller lever: Standard model
Roller lever: High-precision model
Roller lever: General-purpose
overtravel model
Roller-lever: High-sensitivity overtravel model
Top-roller plunger
Sealed top-roller plunger
(3) Built-in Switch Type
Blank
55
Standard
Hermetically sealed
K13A
K13
K43A
K43
-M1J *
-M1GJ *1
-M1JB
-AGJ03
-DGJ03 *1
-DK1EJ03 *1
Direct-wired Connector (2-conductor: AC, NO wiring, connector pins No. 3, 4)
Direct-wired Connector (2-conductor: DC, NO wiring, connector pins No. 3, 4)
Direct-wired Connector (4-conductor: AC)
Direct-wired Connector (4-conductor: DC)
Pre-wired Connector *2 (2-conductor: DC, NO wiring, connector pins No. 3, 4)
Pre-wired Connector *2 (2-conductor: DC, NO wiring, connector pins No. 1, 4)
Pre-wired Connector *2 (2-conductor: DC, NC wiring, connector pins No. 3, 2)
Pre-wired Connector *2 (4-conductor, AC)
Pre-wired Connector *2 (4-conductor, DC)
Pre-wired Connector *2 (3-conductor: DC, NO wiring, connector pins No. 2, 3, 4)
*1. Models with pre-wired connectors and DC specifications have EN/IEC approval (CE marking).
*2. With 0.3-m cable attached.
Note: Dimensions are the same as the standard models.
Spatter-prevention Switches
WL @ @-@ @ S @
(1) (2) (3) (4)
Standard load
Microload
Note: Dimensions are the same as the standard models.
(2) Actuator Type
CA2
GCA2
H2
G2
D28
Roller lever: Standard model
Roller lever: High-precision model
Roller lever: General-purpose Overtravel model
Roller lever: High-sensitivity Overtravel model
Sealed top-roller plunger
(3) Built-in Switch Type
Blank
55
Standard
Hermetically sealed
Note: Dimensions are the same as the standard models.
(4) Indicator Type
LD
LE
WLM @ -LD @
(5)
(1) Electrical Rating
Blank
01
Long-life Switches
LED, AC/DC
Neon lamp
(1) (2) (3)
(1) Actuator
CA2
GCA2
H2
G2
Roller lever: Standard model
Roller lever: High-precision model
Roller lever: General-purpose overtravel model
Roller lever: High-sensitivity overtravel model
(2) Indicator Type
LD
LED, 10 to 115 VAC/DC
(3) Wiring Specifications
Blank
K13A
K13
K43A
K43
-M1J
-AGJ03
-DGJ03
Screw terminal: G1/2 conduit
Direct-wired Connector: 2-conductor, AC
Direct-wired Connector: 2-conductor, DC
Direct-wired Connector: 4-conductor, AC
Direct-wired Connector: 4-conductor, DC
Pre-wired Connector: 2-conductor, DC *
Pre-wired Connector: 4-conductor, AC *
Pre-wired Connector: 4-conductor, DC *
* With 0.3-m cable attached.
Note: Dimensions are the same for both LE and LD models.
(5) Wiring Specifications
Blank
Screw terminal: G1/2 conduit
Pre-wired Connector *2
-M1J-1 *1
(2-conductor: DC, NO wiring, connector pins No. 3, 4)
Pre-wired Connector *2
-M1GJ-1 *1
(2-conductor: DC, NO wiring, connector pins No. 1, 4)
-DGJS03 *1 Pre-wired Connector *2 (4-conductor: DC)
*1. Models with pre-wired connectors and DC specifications are approved by
EN/IEC (CE marking) except for LE Models (Neon Lamp Models).
*2. With 0.3-m cable attached.
10
WL/WLM
Ordering Information
General-purpose Switches
Note: Models are also available with ground terminals.
Standard Switches
Lever
Actuator
Roller lever R38
Item
Standard load
Basic
Microload
Standard load
Generalpurpose
Microload
Standard load
Highsensitivity Microload
Overtravel
Standard load
Microload
90°
operation Standard load
Microload
Standard load
High-precision
Microload
Model
WLCA2
WL01CA2
WLH2
WL01H2
WLG2
WL01G2
WLCA2-2
WL01CA2-2
WLCA2-2N
WL01CA2-2N
WLGCA2
WL01GCA2
Actuator Adjustable roller
lever
Item
Basic
Overtravel
Standard load
Microload
Standard load
Generalpurpose
Microload
Standard load
Highsensitivity Microload
Standard load
Microload
90°
operation Standard load
Microload
Item
Maintained
Model
WLCA12
WL01CA12
WLH12
WL01H12
WLG12
WL01G12
WLCA12-2
WL01CA12-2
WLCA12-2N
WL01CA12-2N
Actuator Fork lever lock (with
WL-5A100 plastic
roller lever)
Model
Standard load WLCA32-41
Microload
WL01CA32-41
Roller lever R50
Roller lever R63
Model
WLCA2-7
WL01CA2-7
—
—
—
—
—
—
—
—
—
—
Model
WLCA2-8
WL01CA2-8
—
—
—
—
—
—
—
—
—
—
Adjustable rod lever
25 to 140mm
Adjustable rod lever
350 to 380mm
Rod spring lever
Model
WLCL
WL01CL
WLHL
WL01HL
WLGL
WL01GL
WLCL-2
—
WLCL-2N
WL01CL-2N
Model
—
—
WLHAL4
—
—
—
—
—
—
—
Model
—
—
WLHAL5
—
—
—
—
—
—
—
Fork lever lock (with
WL-5A102 plastic
roller lever)
Model
WLCA32-42
—
Fork lever lock (with
WL-5A104 plastic
roller lever)
Model
WLCA32-43
WL01CA32-43
Fork lever lock (with
WL-5A104 plastic
roller lever)
Model
WLCA32-44
WL01CA32-44
Top-ball plunger
Sealed top-roller
plunger
Plunger
Actuator
Top plunger
Item
Top plunger
Model
Standard load WLD
Microload
WL01D
Actuator
Horizontal plunger
Item
Side plunger
Model
Standard load WLSD
Microload
WL01SD
Top-roller plunger
Model
WLD2
WL01D2
Model
WLD3
WL01D3
Horizontal-roller
plunger
Horizontal-ball
plunger
Model
WLSD2
WL01SD2
Model
WLSD3
WL01SD3
Coil spring (spring
diameter: 4.8)
Coil spring
(resin rod
diameter: 8)
Model
WLNJ-2
WL01NJ-2
Model
WLD28
WL01D28
Flexible Rod
Actuator Coil spring (spring
diameter: 6.5)
Item
Flexible rod
Model
Standard load WLNJ
Microload
WL01NJ
Model
WLNJ-30
WL01NJ-30
Steel wire (wire
diameter: 1)
Model
WLNJ-S2
WL01NJ-S2
11
WL/WLM
General-purpose Switches
Indicator-equipped Switches
Lever
Actuator
Roller lever R38
Item
Neon lamp
Basic
LED
Neon lamp
Generalpurpose
LED
Neon lamp
Highsensitivity LED
Overtravel
Neon lamp
LED
90°
operation Neon lamp
LED
Neon lamp
High-precision
LED
Model
WLCA2-LE
WLCA2-LD
WLH2-LE
WLH2-LD
WLG2-LE
WLG2-LD
WLCA2-2LE
WLCA2-2LD
WLCA2-2NLE
WLCA2-2NLD
WLGCA2-LE
WLGCA2-LD
Actuator Adjustable rod lever
25 to 140 mm
Item
Basic
Overtravel
Neon lamp
LED
Neon lamp
Generalpurpose
LED
Neon lamp
Highsensitivity LED
Neon lamp
LED
90°
operation Neon lamp
LED
Item
Maintained
Model
WLCL-LE
WLCL-LD
WLHL-LE
WLHL-LD
WLGL-LE
WLGL-LD
WLCL-2LE
WLCL-2LD
WLCL-2NLE
WLCL-2NLD
Actuator Fork lever lock (with
WL-5A100 Plastic
Roller Lever)
Model
Neon lamp
WLCA32-41LE
LED
WLCA32-41LD
Roller lever R50
Roller lever R63
Model
WLCA2-7LE
WLCA2-7LD
—
—
—
—
—
—
—
—
—
—
Model
WLCA2-8LE
WLCA2-8LD
—
—
—
—
—
—
—
—
—
—
Adjustable rod lever
350 to 380 mm
Rod spring lever
Model
—
—
WLHAL4-LE
WLHAL4-LD
—
—
—
—
—
—
Model
—
—
WLHAL5-LE
WLHAL5-LD
—
—
—
—
—
—
Fork lever lock (with
WL-5A102 Plastic
Roller Lever)
Model
WLCA32-42LE
Fork lever lock (with
WL-5A104 Plastic
Roller Lever)
Model
WLCA32-43LE
WLCA32-43LD
—
Adjustable roller
lever
Model
WLCA12-LE
WLCA12-LD
WLH12-LE
WLH12-LD
WLG12-LE
WLG12-LD
WLCA12-2LE
WLCA12-2LD
WLCA12-2NLE
WLCA12-2NLD
—
—
Plunger
Actuator
Top plunger
Item
Top plunger
Neon lamp
LED
Side plunger
Neon lamp
LED
Top-ball plunger
Model
WLD-LE
WLD-LD
Model
WLD2-LE
WLD2-LD
Model
WLD3-LE
WLD3-LD
Horizontal plunger
Horizontal-roller
plunger
Horizontal-ball
plunger
Model
WLSD-LE
WLSD-LD
Model
WLSD2-LE
WLSD2-LD
Model
WLSD3-LE
WLSD3-LD
Coil spring (spring
diameter: 6.5)
Coil spring (spring
diameter: 4.8)
Model
WLNJ-LE
WLNJ-LD
Model
WLNJ-30LE
WLNJ-30LD
Actuator
Item
Top-roller plunger
Sealed top-roller
plunger
Model
WLD28-LE
WLD28-LD
Flexible Rod
Actuator
Item
Flexible rod
Neon lamp
LED
Coil spring
(resin rod
diameter: 8)
Model
WLNJ-2LE
WLNJ-2LD
Steel wire (wire
diameter: 1)
Model
WLNJ-S2LE
WLNJ-S2LD
12
WL/WLM
General-purpose Switches
Sensor I/O Connector Switches
Direct-wired Connectors
Item
Actuator
Roller lever
Wiring
connector Standard
2-conDC NO pins
ductor
Airtight seal
No. 3, 4
4-conDC
ductor
Top-roller
plunger
Built-in switch
specification
Model
Overtravel
General-purpose
High-sensitivity
Model
Model
High-precision
Model
WLCA2-LDK13
WLH2-LDK13
WLG2-LDK13
WLGCA2-LDK13
WLCA2-55LDK13
WLH2-55LDK13
WLG2-55LDK13
WLGCA2-55LDK13
Standard
WLCA2-LDK43
WLH2-LDK43
WLG2-LDK43
WLGCA2-LDK43
Airtight seal
WLCA2-55LDK43
WLH2-55LDK43
WLG2-55LDK43
WLGCA2-55LDK43
connector Standard
2-conDC NO pins
ductor
Airtight seal
No. 3, 4
4-conDC
ductor
Basic
WLD2-LDK13
—
—
—
WLD2-55LDK13
—
—
—
Standard
WLD2-LDK43
—
—
—
Airtight seal
WLD2-55LDK43
—
—
—
Pre-wired Connectors
Item
Actuator
Wiring
NO
2-conDC
ductor
Roller lever
Built-in switch
specification
3-conDC
ductor
NO
2-conDC
ductor
Top-roller
plunger
WLCA2-LD-M1J
connector Standard
pins
Airtight seal
No. 1, 4
WLCA2-LD-M1GJ
3-conDC
ductor
WLCA2-55LD-M1J
WLCA2-55LD-M1GJ
—
WLCA2-55LD-M1JB
Overtravel
General-purpose
High-sensitivity
Model
WLH2-LD-M1J
—
WLH2-LD-M1GJ
—
Model
WLG2-LD-M1J
—
WLG2-LD-M1GJ
High-precision
Model
WLGCA2-LD-M1J
WLGCA2-55LD-M1J
WLGCA2-LD-M1GJ
WLG2-55LD-M1GJ
—
—
WLG2-LD-M1JB
—
—
WLG2-55LD-M1JB WLGCA2-55LD-M1JB
Standard
WLCA2-LD-DGJ03 WLH2-LD-DGJ03
WLG2-LD-DGJ03
Airtight seal
WLCA2-55LD-DGJ03
—
WLG2-55LD-DGJ03 WLGCA2-55LD-DGJ03
connector Standard
pins
No. 2, 3, 4 Airtight seal
WLCA2-LD-DK1EJ03
—
WLG2-LD-DK1EJ03
—
WLCA2-55LD-DK1EJ03
—
WLG2-55LD-DK1EJ03
—
connector Standard
pins
Airtight seal
No. 3, 4
WLD2-LD-M1J
—
—
—
WLD2-55LD-M1J
—
—
—
connector Standard
pins
Airtight seal
No. 1, 4
WLD2-LD-M1GJ
—
—
—
WLD2-55LD-M1GJ
—
—
—
connector Standard
NC pins
Airtight seal
No. 3, 2
4-conDC
ductor
Model
connector Standard
pins
Airtight seal
No. 3, 4
connector Standard
NC pins
Airtight seal
No. 3, 2
4-conDC
ductor
Basic
Standard
Airtight seal
connector Standard
pins
No. 2, 3, 4 Airtight seal
—
—
—
—
—
WLD2-55LD-M1JB
—
—
—
WLD2-LD-DGJ03
—
—
—
—
—
—
—
WLD2-LD-DK1EJ03
—
—
—
WLD2-55LD-DK1EJ03
—
—
—
13
WL/WLM
Environment-resistant Switches
Note: Models are also available with ground terminals.
Actuator
Roller lever R38
Basic
Item
Airtight seal
-139
Molded
-140
terminals
Hermetic
seal
-141
Anti-coolant
Heat-resistant
Low-temperature
Corrosion-proof
Weather-proof
No indicator
LED
Indicator
Neon
No indicator
NC wiring
Indicator
NO wiring
No indicator
NC wiring
Indicator
NO wiring
No indicator
NC wiring
Indicator
NO wiring
No indicator
NC wiring
Indicator
NO wiring
No indicator
Model
WLCA2-55
WLCA2-55LD
WLCA2-55LE
WLCA2-139
WLCA2-139LD2
WLCA2-139LD3
WLCA2-140
WLCA2-140LD2
WLCA2-140LD3
WLCA2-141
WLCA2-141LD2
WLCA2-141LD3
WLCA2-RP60
WLCA2-RP60LD2
WLCA2-RP60LD3
WLCA2-TH
WLCA2-TC
WLCA2-RP
WLCA2-P1
Overtravel
General-purpose
High-sensitivity
Model
Model
WLH2-55
WLG2-55
WLH2-55LD
WLG2-55LD
WLH2-55LE
WLG2-55LE
WLH2-139
WLG2-139
—
—
—
WLG2-139LD3
WLH2-140
WLG2-140
—
WLG2-140LD2
—
WLG2-140LD3
WLH2-141
WLG2-141
—
WLG2-141LD2
WLH2-141LD3
WLG2-141LD3
WLH2-RP60
WLG2-RP60
—
WLG2-RP60LD2
WLH2-RP60LD3
WLG2-RP60LD3
WLH2-TH
WLG2-TH
WLH2-TC
WLG2-TC
WLH2-RP
WLG2-RP
WLH2-P1
WLG2-P1
Actuator
Roller lever R38
Overtravel
Item
Airtight seal
-139
Molded
-140
terminals
Hermetic
seal
-141
Anti-coolant
Heat-resistant
Low-temperature
Corrosion-proof
No indicator
LED
Indicator
Neon
No indicator
NC wiring
Indicator
NO wiring
No indicator
NC wiring
Indicator
NO wiring
No indicator
NC wiring
Indicator
NO wiring
No indicator
NC wiring
Indicator
NO wiring
No indicator
90° (-2 model)
Model
WLCA2-255
WLCA2-255LD
WLCA2-255LE
WLCA2-2139
WLCA2-2139LD2
WLCA2-2139LD3
—
—
—
—
—
—
WLCA2-2RP60
WLCA2-2RP60LD2
WLCA2-2RP60LD3
WLCA2-2TH
WLCA2-2TC
—
90° (-2N model)
Model
WLCA2-2N55
WLCA2-2N55LD
WLCA2-2N55LE
WLCA2-2N139
—
—
WLCA2-2N140
—
—
—
—
—
—
—
—
WLCA2-2NTH
WLCA2-2NTC
—
High-precision
Model
WLGCA2-55
WLGCA2-55LD
WLGCA2-55LE
WLGCA2-139
WLGCA2-139LD2
WLGCA2-139LD3
WLGCA2-140
WLGCA2-140LD2
WLGCA2-140LD3
WLGCA2-141
—
WLGCA2-141LD3
WLGCA2-RP60
WLGCA2-RP60LD2
WLGCA2-RP60LD3
WLGCA2-TH
WLGCA2-TC
WLGCA2-RP
14
WL/WLM
Actuator
Adjustable roller lever
Basic
Item
Airtight seal
-139
Molded
-140
terminals
-141
Anti-coolant
Heat-resistant
Low-temperature
Corrosion-proof
Weather-proof
Hermetic
seal
No indicator
LED
Indicator
Neon
No indicator
No indicator
Model
WLCA12-55
WLCA12-55LD
WLCA12-55LE
WLCA12-139
WLCA12-140
WLCA12-141
WLCA12-RP60
WLCA12-TH
WLCA12-TC
WLCA12-RP
WLCA12-P1
Overtravel
General-purpose
High-sensitivity
Model
Model
—
—
—
—
—
—
—
—
—
—
—
—
—
—
WLH12-TH
WLG12-TH
WLH12-TC
WLG12-TC
WLH12-RP
WLG12-RP
WLH12-P1
WLG12-P1
Actuator
Adjustable roller lever
Overtravel
Item
Heat-resistant
Low-temperature
90° (-2 model)
Model
WLCA12-2TH
WLCA12-2TC
No indicator
90° (-2N model)
Model
WLCA12-2NTH
WLCA12-2NTC
Actuator
Adjustable rod lever 25 to 140 mm
Basic
Item
Airtight seal
-139
Molded
-140
terminals
-141
Anti-coolant
Heat-resistant
Low-temperature
Corrosion-proof
Weather-proof
Hermetic
seal
No indicator
LED
Indicator
Neon
No indicator
No indicator
Model
WLCL-55
WLCL-55LD
—
WLCL-139
WLCL-140
—
WLCL-RP60
WLCL-TH
WLCL-TC
WLCL-RP
WLCL-P1
Overtravel
General-purpose
High-sensitivity
Model
Model
—
—
—
—
—
—
—
—
—
—
—
—
—
—
WLHL-TH
WLGL-TH
WLHL-TC
WLGL-TC
WLHL-RP
WLGL-RP
WLHL-P1
WLGL-P1
Actuator
Adjustable rod lever 25 to 140 mm
Overtravel
Item
Heat-resistant
Low-temperature
Corrosion-proof
No indicator
90° (-2 model)
Model
WLCL-2TH
WLCL-2TC
WLCL-2RP
90° (-2N model)
Model
WLCL-2NTH
WLCL-2NTC
—
15
WL/WLM
Actuator
Item
Airtight seal
Hermetic
seal
-139
Molded
terminals -140
Anti-coolant
Heat-resistant
Low-temperature
Corrosion-proof
No indicator
LED
Indicator
Neon
Top-roller plunger
Sealed top-roller plunger
Horizontal plunger
Model
WLD2-55
WLD2-55LD
WLD2-55LE
Model
WLD28-55
WLD28-55LD
WLD28-55LE
Model
WLSD-55
WLSD-55LD
—
WLD2-139
WLD28-139
WLSD-139
No indicator
—
WLD2-RP60
WLD2-TH
WLD2-TC
WLD2-RP
No indicator
WLD28-140
WLD28-RP60
WLD28-TH
—
WLD28-RP
—
WLSD-RP60
WLSD-TH
WLSD-TC
WLSD-RP
Note: The standard cable length for models with airtight seals is 5 m.
Actuator Horizontal-roller
plunger
Item
Airtight seal
Hermetic
seal
-139
Molded
terminals -140
Anti-coolant
Heat-resistant
Low-temperature
Corrosion-proof
No indicator
LED
Indicator
Neon
No indicator
No indicator
Coil spring (spring
diameter: 6.5)
Model
WLSD2-55
WLSD2-55LD
—
Model
WLNJ-55
WLNJ-55LD
—
WLSD2-139
WLNJ-139
Coil spring (resin rod
diameter: 8)
Model
WLNJ-255
WLNJ-255LD
—
—
WLSD2-140
WLNJ-140
WLNJ-2140
WLSD2-RP60
WLSD2-TH
WLSD2-TC
WLSD2-RP
WLNJ-RP60
WLNJ-TH
WLNJ-TC
WLNJ-RP
WLNJ-2RP60
—
WLNJ-2TC
WLNJ-2RP
Note: The standard cable length for models with airtight seals is 5 m.
16
WL/WLM
Spatter-prevention Switches
Actuator
Roller lever
Sealed top-roller plunger
Double nut lever
Item
Basic
Neon lamp
operation
indicator
LED
operation
indicator
General-purpose
High-sensitivity
High-precision
Basic
General-purpose
Overtravel
High-sensitivity
High-precision
Overtravel
Allen-head lever
Model
WLCA2-LEAS
WLH2-LEAS
WLG2-LEAS
—
WLCA2-LDAS
WLH2-LDAS
WLG2-LDAS
—
Model
WLCA2-LES
WLH2-LES
WLG2-LES
WLGCA2-LES
WLCA2-LDS
WLH2-LDS
WLG2-LDS
WLGCA2-LDS
Model
WLD28-LES
—
—
—
WLD28-LDS
—
—
—
Note: Ask your OMRON representative about WL01@-@S Microload Switches.
Long-life Switches
Item
Basic
Actuator
Model
Roller lever, screw
terminal
Roller lever,
direct-wired
connector
Roller lever,
pre-wired
connector *2
WLMCA2-LD
LED operation indicator *1
Overtravel
General-purpose
High-sensitivity
Model
Model
WLMH2-LD
WLMG2-LD
High-precision
Model
WLMGCA2-LD
AC
WLMCA2-LDK13A
WLMH2-LDK13A
WLMG2-LDK13A
WLMGCA2-LDK13A
DC
WLMCA2-LDK13
WLMH2-LDK13
WLMG2-LDK13
WLMGCA2-LDK13
AC
WLMCA2-LDK43A
WLMH2-LDK43A
WLMG2-LDK43A
WLMGCA2-LDK43A
DC
WLMCA2-LDK43
WLMH2-LDK43
WLMG2-LDK43
WLMGCA2-LDK43
2-conductor
DC
WLMCA2-LD-M1J
WLMH2-LD-M1J
WLMG2-LD-M1J
WLMGCA2-LD-M1J
4-conductor
DC
WLMCA2-LD-DGJ03
WLMH2-LD-DGJ03
WLMG2-LD-DGJ03
2-conductor
4-conductor
—
*1. The default setting is “light-ON when not operating.”
Turn the lamp holder by 180° to change the setting to “light-ON when operating”. (Ask your OMRON representative about 2-conductor models.)
*2. With 0.3-m cable attached.
Connecting Cables
Straight Cable
Voltage specification
Number of conductors
2
AC
4
2
DC
4
Cable length
Model
2m
5m
2m
5m
2m
5m
2m
5m
XS2F-A421-DB0-F
XS2F-A421-GB0-F
XS2F-A421-D90-F
XS2F-A421-G90-F
XS2F-D421-DD0
XS2F-D421-GD0
XS2F-D421-D80-F
XS2F-D421-G80-F
17
WL/WLM
Individual Parts
Heads
Actuator type
Roller lever
Adjustable
roller lever
Adjustable
rod lever
Set model
WLCA2
WLG2
WLH2
WLCA2-2
WLCA2-2N
WLCA12
WLG12
WLH12
WLCA12-2
WLCA12-2N
WLCL
WLGL
WLCL-2
WLCL-2N
Head model (with Actuator)
WL-1H1100
WL-2H1100
WL-2H1100-1 *
WL-3H1100
WL-6H1100
WL-1H2100
WL-2H2100
WL-2H2100-1 *
WL-3H2100
WL-6H2100
WL-4H4100
WL-2H4100
WL-3H4100
WL-6H4100
Actuator type
Top plunger
Horizontal
plunger
Fork lever
lock
Coil spring
Set model
WLD
WLD2
WLD3
WLD28
WLSD
WLSD2
WLSD3
WLCA32-41
WLCA32-42
WLCA32-43
WLCA32-44
WLNJ
WLNJ-30
WLNJ-2
WLNJ-S2
Head model (with Actuator)
WL-7H100
WL-7H200
WL-7H300
WL-7H400
WL-8H100
WL-8H200
WL-8H300
WL-5H5100
WL-5H5102
WL-5H5104
WL-5H5104
WL-9H100
WL-9H200
WL-9H300
WL-9H400
* The model number of Heads without levers are same as those of Heads with levers without the numbers at the end.
Example: WL-1H1100 becomes WL-1H without the lever.
However, the WLH2 and WLH12 become WL-2H-1 and the WLGCA2 becomes WL-1H-1 for the Heads without levers.
Other Heads are also available. Ask your OMRON representative.
Switches without levers
Switches without levers
Actuator type
Model
Switches for roller levers
Switches for adjustable
roller levers
Switches for adjustable
rod lever
Basic R38
High-precision R38
High-sensitivity overtravel, 80°
General-purpose overtravel, 80°
Overtravel, 90° operation
Overtravel, 90° operation
Basic
High-sensitivity overtravel, 80°
General-purpose overtravel, 80°
Overtravel, 90° operation
Overtravel, 90° operation
Basic, 25 to 140 mm
High-sensitivity overtravel, 80°, 25 to 140 mm
Overtravel, 90° operation, 25 to 140 mm
Overtravel, 90° operation, 25 to 140 mm
WLRCA2
WLRGCA2
WLRG2
WLRH2
WLRCA2-2
WLRCA2-2N
WLRCA2
WLRG2
WLRH2
WLRCA2-2
WLRCA2-2N
WLRCL
WLRG2
WLRCA2-2
WLRCA2-2N
Switches for top plungers
—
—
Switches for horizontal
plungers
—
—
Maintained, WL-5A100
Maintained, WL-5A102
Maintained, WL-5A104
Switches for fork
lever locks
Switches for coil springs
—
WLRCA32
—
Covers with Operation Indicators
Cover
Item
Neon lamp
LED
Cover only with
indicator
Model
WL-LE
WL-LD
Note: The default setting is "light-ON when not operating."
Turn the lamp holder by 180° to change the setting to "light-ON when operating."
18
WL/WLM
Spatter-prevention Products
Head (with actuator)
Complete Heads
with allen-head
levers
Model
Lever
Double Nut
Lever
Cover with indicator Switches without Levers
Allen-head
Lever
Model
Double Nut
Lever
Model
Model
WL-1A103S
Roller lever
WL-1A105S
Roller Lever
Cover with
Indicator
Model
Neon lamp
WL-1H1100S
(for WLCA2-@ or
WLGCA2-@)
WL-2H1100S
(for WLH2-@ or
WLG2-@)
WL-LES
LED (LED)
WL-LDS
Switches
without
levers
Model
WLRCA2-LDS
WLRH2-LES
WLRH2-LDS
WLRG2-LDS
WLRGCA2-LES
WL Head Replacement
Heads can be replaced within the same model group. They cannot be replaced between different model groups.
Group No.
1
2
3
4
5
6
7
8
9
10
11
12
13
Set model number
WLCA2
WLCA2-7
WLCA2-8
WLCA12
WLCL
WLH2
WLH12
WLHL
WLHAL4
WLHAL5
WLCA2-2N
WLCA12-2N
WLCL-2N
WLCA2-2
WLCA12-2
WLCL-2
WLG2
WLG12
WLGL
WLCA32-41
WLCA32-42
WLCA32-43
WLCA32-44
WLD
WLD2
WLD3
WLD28
WLSD
WLSD2
WLSD3
WLNJ
WLNJ-30
WLNJ-2
WLNJ-S2
Head model number (with Actuator)
WL-1H1100
WL-1H1200
WL-1H1300
WL-1H2100
WL-4H4100 *
WL-2H1100-1
WL-2H2100-1
WL-2H4100
WL-2H4106
WL-2H4107
WL-6H1100
WL-6H2100
WL-6H4100
WL-3H1100
WL-3H2100
WL-3H4100
WL-2H1100
WL-2H2100
WL-2H4100
WL-5H5100
WL-5H5102
WL-5H5104
WL-5H5104
WL-7H100
WL-7H200
WL-7H300
WL-7H400 *
WL-8H100
WL-8H200
WL-8H300
WL-9H100
WL-9H200
WL-9H300 *
WL-9H400 *
* This Heads are special and must be used. Do not use any other Head.
Specifications
Approved Standards
Agency
UL
CSA
Standard
UL508
CSA C22.2 No.14
TÜV Rheinland
EN60947-5-1
CCC (CQC)
GB14048.5
File No.
Approved models
E76675
LR45746
J50022353,
Contact your OMRON representative for information on approved models.
J9950023,
J9950959
2004010305128675
19
WL/WLM
General-purpose/Weather-proof Switches
Ratings
Item
Model
Basic models,
overtravel
models (except
for highsensitivity
models), and
high-precision
models
High-sensitivity
overtravel
models
Microload Switches (Refer to these ratings before using the product.)
Non-inductive load (A)
Resistive
Lamp
load
load
NC NO NC NO
10
3
1.5
10
2
1
10
1.5 0.8
10
6
3
10
6
3
6
4
3
0.8
0.2 0.2
0.4
0.1 0.1
5
—
5
0.4
—
0.2
Rated
voltage
(V)
125 VAC
250 VAC
500 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
125 VAC
250 VAC
125 VDC
250 VDC
Inductive load (A)
Inductive
Motor
load
load
NC NO NC NO
10
5
2.5
10
3
1.5
3
1.5 0.8
10
6
10
6
6
4
0.8
0.2
0.4
0.1
—
—
—
—
Note: 1. The above figures are for steady-state
30 A max.
currents.
Inrush NC (15 A max. *)
2. Inductive loads have a power factor of 0.4 min.
cur(AC) and a time constant of 7 ms max. (DC).
20
A
max.
rent
NO (10 A max. *)
3. A lamp load has an inrush current of 10
times the steady-state current.
4. A motor load has an inrush current of 6
times the steady-state current.
5. For PC loads, use the microload models.
* For high-sensitivity
overtravel models.
Minimum applicable load
120 VAC
240 VAC
480 VAC
600 VAC
Current (A)
Volt-amperes (VA)
Make
Break
Make
Break
60
30
15
12
6
3
1.5
1.2
7,200
720
10 A
0.1
DC 30
Operation in the following ranges will produce optimum performance.
5 to 30 VDC
0.5 to 100 mA
Recommended load range
30
10
5
0.8 W
5 mW
1
0.1 0.16
1
5 10
Degree of protection
Durability Mechanical
*1
Electrical
Operating speed
Operating Mechanical
frequency Electrical
Rated frequency
Insulation resistance
Contact resistance
Microload Switches
0.1 A 125 VAC, 0.1 A 30 VDC
TÜV (EN60947-5-1) (Only models with ground terminals are approved.)
Application category
and ratings
Thermal current (Ithe)
Indicator
WL@
AC-15: 2 A/250 V
DC-12: 2 A/48 V
10 A
—
WL01@
AC-14: 0.1 A/125V
DC-12: 0.1 A/48 V
0.5 A
—
WL@-LE
AC-15: 2 A/250 V
10 A
Neon lamp
WL01@-LE
AC-14: 0.1 A/125 V
0.5 A
Neon lamp
WL@-LD
AC-15: 2 A/115 V
DC-12: 2 A/48 V
10 A
LED
WL01@-LD
AC-14: 0.1 A/115 V
DC-12: 0.1 A/48 V
0.5 A
LED
Model
Note: As an example, AC-15: 2 A/250 V means the following:
Application category
AC-15
Rated operating current (Ie)
2A
Rated operating voltage (Ue)
250V
Indicator-equipped Switches
Model
WL-LE
WL-LD
Item
Neon
lamp
LED
100
Current (mA)
5 VDC 1 mA
Characteristics
UL/CSA
Standard-load Switches: A600, NEMA
Carry current
Rated current (A) - Resistive load
AC 125
Recommended load range
5 VDC 160 mA
Approved Standard Ratings
Rated
voltage
Rated voltage (V)
Voltage (VDC)
Standard-load Switches
Max. rated voltage (V)
Leakage current (mA)
125 AC
Approx. 0.6
250 AC
Approx. 1.9
115 AC/DC
Approx. 0.5
10 to 24 AC/DC
Approx. 0.4
Between terminals
of the same polarity
Between currentDielectric carrying metal part
strength
and ground
Between each terminal and non-currentcarrying metal part
Rated insulation voltage (Ui)
Pollution degree (operating
environment)
Short-circuit protective device (SCPD)
Conditional short-circuit current
Conventional enclosed thermal
current (Ithe)
Protection against electric shock
Vibration
Malfunction
resistance
Destruction
Shock
resistance Malfunction
Ambient operating temperature
Ambient operating humidity
Weight
IP67
15,000,000 operations min. *2
750,000 operations min. *3
1 mm/s to 1 m/s (in case of WLCA2)
120 operations/minute min.
30 operations/minute min.
50/60 Hz
100 MΩ min. (at 500 VDC)
25 mΩ max. (initial value for the built-in
switch when tested alone) *6
1,000 VAC (600 VAC), 50/60 Hz for
1 min
2,200 VAC (1,500 VAC), 50/60 Hz for
1 min/Uimp 2.5 kV
2,200 VAC (1,500 VAC), 50/60 Hz for
1 min/Uimp 2.5 kV
250 V (EN60947-5-1)
3 (EN60947-5-1)
10 A, fuse type gG or gI (IEC60269)
100 A (EN60947-5-1)
10 A, 0.5 A (EN60947-5-1)
Class I
10 to 55 Hz, 1.5-mm double amplitude *4
1,000 m/s2 max.
300 m/s2 max. *4
–10°C to +80°C (with no icing) *5
35% to 95% RH
Approx. 275 g (in case of WLCA2)
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are those for the highsensitivity overtravel models.
*1. The values are calculated at an operating temperature of +5°C to +35°C and an
operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating environments.
*2. Durability is 10,000,000 operations min. for general-purpose or highsensitivity overtravel models, and for flexible rod models.
500,000 operations min. for weather-proof models.
*3. Durability is 500,000 operations min. for high-sensitivity models. All
microload models are 1,000,000 operations min.
500,000 operations min. for weather-proof models.
*4. Except flexible rod models. The shock resistance (malfunction) for
microload models is 200 m/s2 max.
*5. For low-temperature models this is –40°C to +40°C (with no icing). For heatresistant models the range is +5°C to +120°C.
*6. For microload models, the contact resistance is 50 mΩ max. (initial value for
built-in switch).
20
WL/WLM
Spatter-prevention Switches
Ratings
Characteristics
Screw terminals
Item
Non-inductive load (A)
Rated
voltage (V)
Model
WL@-LES
Resistive
load
NC
NO
NC
NO
3
2
1.5
1
10
3
10
6
3
6
4
2
125 VAC
250 VAC
10
10
115 VAC
WL@-LDS 12 VDC
24 VDC
48 VDC
Lamp
load
Inductive load (A)
Inductive
load
NC
NO
Motor
load
NC
NO
10
10
5
3
2.5
1.5
1.5
10
5
3
3
1.5
10
6
3
2.5
6
4
2
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-state current.
4. A motor load has an inrush current of 6 times the steady-state current.
NC
NO
Operating temperature
Operating humidity
Inrush
current
30 A max.
20 A max.
–10°C to +80°C (with no icing)
35% to 95%RH max.
Approved Standard Ratings
UL/CSA
LE Switches (Neon lamp): A300
Rated
voltage
Carry
current
120 VAC
240 VAC
10 A
Current (A)
Make
Break
60
6
30
3
Volt-amperes (VA)
Make
Break
7,200
720
LD Switches (LED)
Rated voltage
115 VAC
115 VDC
Carry current
10 A
0.8 A
CCC (GB14048.5)
Model
WL@
WL01@
WL@-LE
WL01@-LE
WL@-LD
WL01@-LD
Application category and ratings
AC-15: 2 A/250 V
DC-12: 2 A/48 V
AC-14: 0.1 A/125V
DC-12: 0.1 A/48 V
AC-15: 2 A/250 V
AC-14: 0.1 A/125 V
AC-15: 2 A/115 V
DC-12: 2 A/48 V
AC-14: 0.1 A/115 V
DC-12: 0.1 A/48 V
Note: As an example, AC-15: 2 A/250 V means the following:
Application category
AC-15
Rated operating current (Ie) 2 A
Rated operating voltage (Ue) 250 V
Degree of protection
Durability Mechanical
*1
Electrical
Operating speed
Operating Mechanical
frequency Electrical
Rated frequency
Insulation resistance
Contact resistance
Between
terminals of
the same
polarity
Between
currentcarrying
Dielectric
metal part
strength
and ground
Between
each
terminal and
non-currentcarrying
metal part
Rated insulation voltage
(Ui)
Pollution degree
(operating environment)
Short-circuit protective
device (SCPD)
Conditional short-circuit
current
Conventional enclosed
thermal current (Ithe)
Protection against
electric shock
Vibration
Malfunction
resistance
Destruction
Shock
resistance Malfunction
Ambient operating
temperature
Ambient operating
humidity
Weight
IP67
15,000,000 operations min. *2
750,000 operations min. *3
1 mm/s to 1 m/s (in case of WLCA2)
120 operations/minute min.
30 operations/minute min.
50/60 Hz
100 MΩ min. (at 500 VDC)
25 mΩ max. (initial value for the builtin switch when tested alone)
1,000 VAC (600 VAC), 50/60 Hz for
1 min
2,200 VAC (1,500 VAC), 50/60 Hz for
1 min/Uimp 2.5 kV
2,200 VAC (1,500 VAC), 50/60 Hz for
1 min/Uimp 2.5 kV
250 V (EN60947-5-1)
3 (EN60947-5-1)
10 A, fuse type gG or gI (IEC60269)
100 A (EN60947-5-1)
10 A, 0.5 A (EN60947-5-1)
Class I
10 to 55 Hz, 1.5-mm double amplitude
1,000 m/s2 max.
300 m/s2 max.
–10°C to +80°C (with no icing)
35% to 95%RH
Approx. 275 g (in case of WLCA2)
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are those for the highsensitivity overtravel models.
*1. The values are calculated at an operating temperature of +5°C to +35°C and
an operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating
environments.
*2. Durability is 10,000,000 operations min. for general-purpose or highsensitivity overtravel models.
*3. Durability is 500,000 operations min. for high-precision models. All
microload models however, are 1,000,000 operations min.
21
WL/WLM
Long-life Switches
Ratings
General Ratings (Refer to these ratings before using the product.)
* For high-sensitivity overtravel models.
Screw Terminal Switches
Direct-wired Connector and Pre-wired Connector Switches
Item
Non-inductive load (A)
Rated
voltage
(V)
Model
Resistive
load
NC
NO
Basic models,
overtravel models, (except for
high-sensitivity
models), and
high-precision
models
115 AC
12 DC
24 DC
48 DC
115 DC
10
6
3
0.8
High-sensitivity
overtravel models
115 AC
5
115 DC
0.4
NC
NO
3
1.5
6
4
2
0.2
3
3
1.5
0.2
Inductive load (A)
Inductive load
NC
NO
10
Motor
load
NC
NO
5
2.5
10
6
3
0.8
6
4
2
0.2
—
—
—
—
—
—
Non-inductive load (A)
DC
AC
30 A max. (15 A max. *)
20 A max. (10 A max. *)
Characteristics
Degree of protection
IP67
Mechanical 30,000,000 operations min.
30,000,000 operations min. (10 mA at
24 VDC, resistive load)
Durability *
750,000 operations min. (10 A at 115
Electrical
VAC, resistive load), but for high-precision models: 500,000 operations
min. (10 A at 115 VAC, resistive load)
Operating speed
1 mm/s to 1 m/s (in case of WLCA2)
Mechanical 120 operations/minute
Operating
frequency
Electrical
30 operations/minute
Rated frequency
50/60 Hz
Insulation resistance
100 MΩ min. (at 500 VDC)
25 mΩ max. (initial value for the builtContact resistance
in switch when tested alone)
Between
terminals of
1,000 VAC (except connector models)
the same
polarity
Between
Dielectric
currentstrength
carrying
2,200 VAC (1,500 V)
(50/60 Hz
metal part
for 1 min)
and ground
Between each
terminal and
2,200 VAC (1,500 V)
non-currentcarrying metal
part
Vibration
Malfunction 10 to 55 Hz, 1.5-mm double amplitude
resistance
Destruction 1,000 m/s2 max.
Shock
resistance Malfunction 300 m/s2 max.
Ambient operating
–10°C to +80°C (with no icing)
temperature
Ambient operating
35% to 95%RH
humidity
Weight
Approx. 275 g (in case of WLCA2)
Resistive
load
Inductive load (A)
Lamp load
Inductive
load
Motor load
NC
NO
NC
NO
NC
NO
NC
NO
12 DC
3
3
3
3
3
3
3
3
24 DC
3
3
3
3
3
3
3
3
48 DC
3
3
3
3
3
3
3
3
115 DC
0.8
0.8
0.2
0.2
0.8
0.8
0.2
0.2
115 AC
3
3
3
1.5
3
3
3
2.5
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
3. A lamp load has an inrush current of 10 times the steady-state current.
4. A motor load has an inrush current of 6 times the steady-state current.
Engineering Data
Electrical Durability: cosφ= 1
(Operating temperature: +5°C to +35°C, operating humidity: 40% to
70%RH)
1,000
4
NC
NO
Rated
voltage
(V)
Model
Durability (× 10 operations)
Inrush
current
10
Lamp
load
Operating frequency:
30 operations/min cos φ= 1
500
125 VAC
300
250 VAC
480 VAC
100
50
30
10
0
2
4
6
8
10
12
Switching current (A)
Note: The figures in parentheses for dielectric strength, are those for overtravel
(high-sensitivity) or connector models.
* The values are calculated at an operating temperature of +5°C to +35°C, and
an operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating environments.
22
WL/WLM
Structure and Nomenclature
Structure
General-purpose Switches: WLCA2
Head-mounting Screws
Head
The Head used in the roller lever type,
adjustable rod lever type, or horizontal
plunger type (except for 90° operation
models) can be mounted in any of the
four directions by removing the screws
at the four corners of the Head.
Shaft Section Seal
By fitting an O-ring to the rotary shaft
and with an appropriate interference
of the screws, high-sealing properties
are maintained.
Actuator
Roller
The roller is made of self-lubricating
sintered stainless steel and boasts
high resistance to wear.
Lever
The lever forged of anti-corrosive
aluminium alloy features high corrosion
resistances and outstanding ruggedness.
With roller lever, adjustable rod and
flexible rod models, the actuator position
can be set anywhere within 360°. (The
lever cannot be mounted in the opposite
direction.)
Roller Lever Setscrew
Operational Plunger *2
Bearing
The bearing smooths the
plunger movement.
Built-in Switch
Built-in switch with SPST-NO+NC
contact form.
Set Position Marker Plate
After operation, set the indicator needle
on the marker plate so that is in the
convex section of the bearing. For the
WLD2, insert the needle so that it is
between the two main wires on the
plunger.
Requires maintenance
(excessive overtravel)
Proper range
Requires maintenance (insufficient overtravel)
Proper range
Requires maintenance
(excessive overtravel)
Terminal Screws
Four, M4 screws
Separator
The separator has outstanding insulation
properties and prevents the generation of any
gases which may corrode the internal parts.
Conduit Opening *1
The conduit threads are parallel threads
for G½ tube and offer further increased
sealing properties when used in
conjunction with the SC connector.
Cover Seal
By using a packing seal as the cover seal,
an optimum squeeze can be obtained and
high sealing properties are assured as well.
Cover
Cover Setscrew
Phillips screws are used
to ensure ease of use.
*1. The display for conduit threads has changed from PF½ to G½, according to revisions of JIS B 0202. This is only a change in the display, so the thread size and
pitch have not changed. (Conduit threads Pg 13.5 and ½-14NPT are also available.)
*2. By changing the orientation of the operational plunger, any one of the three operational directions (both sides, left, or right) can be selected electrically.
23
WL/WLM
Indicators
Indicator Covers
Indicator
The indicator covered if outsert molded
from diecast aluminum and has
outstanding sealing properties.
The indicator is either a neon lamp or
an LED. Models with LED indicators
have a built-in rectifier stack, so it is not
necessary to change the polarity.
Indicator Windows
Operation (i.e., light-ON when operating
or light-ON when not operating) depends
on whether a neon lamp or LED is used.
Contact Spring
The built-in switch's terminal screws
are used to connect the indicator
terminal. Since the connection spring
(coil spring) is used for this connection,
it will not be necessary to connect the
indicator terminal. When a ground
terminal is provided however, a lead
wire must be used.
Light-ON when Operating/Not Operating
Indicators can be switched from light-ON
when operating and light-ON when not
operating, by simply rotating the indicator
holder by 180°.
(Molded terminals cannot be switched in
this way.)
Light-ON when Operating
Light-ON when Not Operating
LED at top
LED at bottom
Operation
Internal Circuits
Power
Neon lamp
Built-in switch
Light-ON when
operating *1
4
Za
WL-LE
3
Contact spring
Resistor
1
2
Load
Internal circuits
WL-LE
WL-LD
Rectifier stack
Contact spring
Power
Resistor
Internal circuits
Light-ON when
not operating *2
WL-LD
Za
4
3
1
2
Load
Zener
diode
Rated
current
diode
Resistor
LED
Built-in switch
Note: 1. The indicator cover cannot be replaced on the molded terminals. In all cases the indicator does not light when the load is ON.
2. Leakage current from indicator circuit may cause load's malfunction. Please check the load's OFF current before use the indicator-equipped switch.
*1. Light-ON when operating means that the lamp lights when the Limit Switch contacts (NC) release, or when the actuator rotates or is pushed down.
*2. Light-ON when not operating means the lamp remains lit when the actuator is free, or when the Limit Switch contacts (NO) close when the actuator rotates or is
pushed down.
24
WL/WLM
Environment-resistant Switches
Mold Specifications for Hermetic Seal Switches
WL@-139
: Molded parts
WL@-140
WL@-141
Oil seal for protection against cutting powder
X-ring
Standard
built-in
switch
WL@-145
Airtight
built-in
switch
WL@-RP40
Oil seal for protection against cutting powder
X-ring
Airtight
built-in
switch
WL@-RP60
O-ring
Airtight
built-in
switch
Airtight
built-in
switch
Airtight
built-in
switch
* Florine rubber is used for
all rubber parts.
Model
WL@-139
WL@-140
WL@-141
WL@-145
WL@RP40
WL@RP60
Cable specifications
Standard 5-m VCT (vinyl cabtire cable) cable attached. Finished diameter: 11.5 mm, 4-conductor.
Standard 5-m VCT cable, with high flexibility and good anti-oil properties attached. Finished
diameter: 11.5 mm, 4-conductor.
Spatter-prevention Switches: WLCA2-LEAS
Actuator
Roller, Roller Axis
Using stainless steel prevents spatter
from adhering.
Operating Lever
Melamine sinter-painted, it is easy to
peel off the spatter.
Double Nut
SUS is used for double nut.
Lamp Cover
· Heat-resistant resin is used for the
lamp cover.
· By using spherical surface for the
display part, it disperses the direction
of spatter.
Screws
SUS is used, preventing spatter
from adhering.
Head Cap
Using fluororesin prevents spatter
from adhering.
* Spatter means the zinc powder
produced when welding.
Adhering spatter to the Limit Switch
may cause malfunction of lever or
lamp cover.
The lack of gap prevents spatter
powder from clogging.
25
WL/WLM
Long-life Switches: WLMGCA2-LD
Release Plunger
Set Position Marker Plate
The set position is easy to view.
Hardening method changed for greater
abrasion resistance.
The stroke is indicated in fluorescent color that
is visible from the slit in the rubber cap.
Long-life Model
Standard Model
Stainless
steel +
Hardening
Sintered
alloy
Standard Model
Long-life Model
Head
The Head can be mounted in any of the
four directions by removing the screws
at the four corners of the Head.
Fluorescent paint
Shaft Section Seal
Requires maintenance (excessive overtravel)
Proper range
Requires maintenance (insufficient overtravel)
Proper range
By fitting a double seal consisting of an
oil seal and an X-ring to the rotary
shaft, even greater sealing properties
are achieved.
Standard Model
O-ring
Requires maintenance (excessive overtravel)
Long-life Model
Oil seal
X-ring
Actuator
Head
Mounting
Screws
Roller
The roller is made of self-lubricating stainless
sintered and boasts high resistance to wear.
Lever
Smoother Movement
A grease holder is provided on the
shaft to prevent the grease from
running out.
The lever forged of anti-corrosive aluminium
alloy features high corrosion resistance and
outstanding ruggedness. With roller lever
models, the actuator position can be set
anywhere within 360°. (The lever cannot be
mounted in the opposite direction.)
Standard Model
Operational Plunger *
Cover Seal
By using a packing seal as the
cover seal, an optimum squeeze
can be obtained and high sealing
properties are assured as well.
Long-life Model
Terminal Screws
Grease holder
Four, M4 screws
Smooth movement is achieved using
olefin grease. (Standard models use
molybdenum disulfide grease.)
Cover
Separator
Bearing
The separator has outstanding
insulation properties and prevents
the generation of any gases
which may corrode the internal
parts.
The bearing smooths the plunger
movement.
Built-in Switch
Built-in switch with SPST-NO+NC
contact form.
Cover Mounting Screw
Conduit Opening
In addition to level screws which use G½
tube, direct-wired and pre-wired connectors
have been added to the Series.
Phillips screws are used to
ensure ease of use.
* By changing the direction of the operational plunger, any one of the three operational directions (both sides, left, or right) can be selected.
26
WL/WLM
Contact Forms
Screw Terminal Switches
Za
(NO) 4
Screw Terminal Switches
Indicator-equipped (Light-ON when Not Operating)
Switches *1
Internal
circuits
3 (NO)
Za
(NO) 4
(NC) 1
3 (NO)
2 (NC)
(NC) 1
Direct-wired Connector Switches
Indicator-equipped (Light-ON when Not Operating)
Switches *1
AC
Pre-wired Connector Switches
Indicator-equipped (Light-ON when Not Operating)
Switches *1
DC
Internal
circuits
Internal
circuits
Za
Za
NO NC
connector pin 2-core 4 -No.
4-core 4 1
NC NO
NO NC
-- 3 connector pin 2-core 4 -2 3 No.
4-core 4 1
2
3
1
3
4
NO
NO NC
4 -connector pin
2-core 4
No.
3
DC (3-core, 4-core)
Internal
circuits
Internal
circuits
Za
Za
NC NO
NO NC
-- 3 connector pin 3-core 4 -1 No.
4-core 4 1
2
NC NO
2 3
2 3
NC
1
NO
4
NC NO
-- 3
2 3
2
NC
NC
DC (2-core)
Positioning piece *2
Positioning piece *2
2 (NC)
NC
NO
NO
Note: Leakage current from indicator circuit may cause load's malfunction. Please check the load's OFF current before use the indicator-equipped switch.
*1. Light-ON when not operating means the indicator is lit when the actuator is free and is not light when the Switch contacts (NO) close when the actuator rotates or
is pushed down.
*2. The position of the positioning piece is not always the same. If using an L-shaped connector causes problems in application, use a straight connector.
27
WL/WLM
Dimensions and Operating Characteristics
(Unit: mm)
General-purpose Models
Standard Models
Basic
Rotating Lever ........ For all models WL@ indicates a standard-load model and WL01@ indicates a microload model.
Roller lever R38
WLCA2
WL01CA2
17.5 dia. × 7 *
60 max.
53 ±1.5
41.5 ±1.5
40 ±1.5
13.1
Four, M3.5
25.4
12.7
38R
Roller lever R50
WLCA2-7
WL01CA2-7
25.4
M5 (length: 12)
Allen-head bolt
(137) 14.7
14.7
(125)
25.4
Four, 5.2 +0.2
0
dia. holes
Four, 5.2 +0.2
0
dia. holes
58.7 ±0.2
25.4
12.7
Four, M3.5
50R
M5 (length: 12)
Allen-head bolt
67.2 max.
58.1 ±1.5
36 ±1.5
13.1
17.5 dia. × 15 *
58.7 ±0.2
68.7
Three, M4
(lengh:13)
68.7
Three, M4
(length: 13)
5
5
21.6
(4.9)
JIS B0202 G½
Effective thread:
4 threads min.
(15.1)
30.2 ±0.2
40 ±0.7
* Stainless sintered roller
Roller lever R63
WLCA2-8
WL01CA2-8
17.5 dia. × 7 *
21.6
Four, M6
Depth: 15 min.
±1.2
29.2
35
60 max.
53.2 ±0.8
(15.1)
30.2 ±0.2
40 ±0.7
(4.9)
* Stainless steel roller
60 max.
53 ±1.5
41.5 ±1.5
40 ±1.5
Four, M3.5
(150)
60 ±1.5
41.5 ±1.5
13.1
17.5 dia. × 7 *
25.4
12.7
Four, M3.5
25.4
12.7
Adjustable range:
25 to 89
M5 (length: 16)
Allen-head bolt
25.4
Four, 5.2 +0.2
0
dia. holes
14.7
Four, 5.2 +0.2
0
dia. holes
Four, M6
Depth: 15 min.
±1.2
29.2
35
42 max.
53.2 ±0.8
67 max.
Adjustable Roller Lever
WLCA12
WL01CA12
13.1
63R
JIS B0202 G½
Effective thread:
4 threads min.
25.4
14.7
M5 (length: 12)
Allen-head bolt
58.7 ±0.2
58.7 ±0.2
68.7
Three, M4
(length: 13)
5
21.6
5
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
JIS B0202 G½
Effective thread:
4 threads min.
* Stainless sintered roller
Adjustable Rod Lever (25 to 140 mm)
9
WLCL
WL01CL
Adjustable range:
25 to 140
14.7
3 ±0.2 dia.
(length: 160) *
Four, M3.5 M8 ×12
Allen-head
set screw
M5 × 12
Allen-head
bolt
21.6
±1.2
29.2
35
42 max.
53.2 ±0.8
46 ±1.5
13.1
(For details
see page 42)
25.4
12.7
(15.1)
30.2 ±0.2
40 ±0.7
* Stainless steel rod
35
42 max.
65.2 ±0.8
Two, 17.5 dia.
(length: 7) *
25.4
12.7
90 ±3°
R38
Four, M3.5
34.1
M5 × 16
Allen-head bolt
14.7
(125)
25.4
Four, 5.2 +0.2
0
dia. holes
58.7 ±0.2
68.7
Three, M4
(length: 13)
68.7
5
5
(4.9)
Four, M6
Depth: 15 min.
62.5 max.
56.4 ±3.5
42.8 ±3.5
13.1
Fork Lever Lock
WLCA32-41 to 44
WL01CA32-41 to 44
55 max.
29.2
JIS B0202 G½
Effective thread:
4 threads min.
* Stainless sintered roller
Four, M6
Depth: 15 min.
Three, M4
(length: 13)
JIS B0202 G½
Effective thread:
4 threads min.
±1.2
(15.1)
30.2 ±0.2
40 ±0.7
(4.9)
Four, 5.2 +0.2
0
dia. holes
58.7 ±0.2
68.7
Three, M4
(length: 13)
21.6
±1.2
29.2
Four, M6
Depth: 15 min.
35
42 max.
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
JIS B0202 G½
Effective thread:
4 threads min.
21.6
Four, M6
±1.2
29.2 Depth: 15 min.
35
42 max.
Note: This illustration shows
the external dimensions * Plastic roller
of the WLCA32-41.
(Models WLCA32-041 to -044 and WL01CA32041 to -044 have stainless steel rollers.)
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Model WLCA2
Operating characteristics
WL01CA2
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF max.
RF min.
PT
OT min.
MD max.
13.34 N
2.23 N
15° ±5°
30°
12°
WLCA2-7
WLCA2-8
WLCA12 *1
WLCL *2
WL01CA2-7 WL01CA2-8 WL01CA12 *1 WL01CL *2
10.2 N
1.67 N
15° ±5°
30°
12°
8.04 N
1.34 N
15° ±5°
30°
12°
13.34 N
2.23 N
15° ±5°
30°
12°
1.39 N
0.27 N
15° ±5°
30°
12°
*1. The operating characteristics for WLCA12 and WL01CA12 are measured at the lever length of
38 mm.
*2. The operating characteristics for WLCL and WL01CL are measured at the rod length of 140 mm.
Operating characteristics
Model WLCA32-41 to 44 *1
WL01CA32-41 to 44 *1
Force necessary to reverse the
direction of the lever: Max.
Movement until the lever reverses
Movement until switch operation: Min.
Movement after switch operation: Max.
11.77 N
50° ±5°
55°
35°
OF and RF for WLCA12, with a lever length of 89 mm.
WLCA12, WL01CA12
OF
5.68 N
RF
0.95 N
28
WL/WLM
Basic
Plunger .................... For all models WL@ indicates a standardTop Plunger
WLD
WL01D
load model and WL01@ indicates a
microload model.
Horizontal Plunger
WLSD
WL01SD
13.1
PT
9.2 dia.
12.9
1R *
PT
OP
46.6 ±0.8
13.1
Four, M3.5
12.7
25.4
Four, M3.5
27.5
19.9
OP
17.8
Four, 5.2 +0.2
0
dia. holes
58.7 ±0.2
1R *1
+0.2 25 dia. *2
Four, 5.2 0
dia. holes
(96.2)
58.7 ±0.2
68.7
Three, M4
(length: 13)
68.7
Three, M4
(length: 13)
5
5
21.6
(4.9)
JIS B0202 G½
Effective thread:
4 threads min.
(15.1)
30.2 ±0.2
40 ±0.7
* Stainless steel plunger
Top-roller Plunger
WLD2
WL01D2
PT
Four, M6
Depth: 15 min.
±1.2
29.2
35
42 max.
17.5 dia. (length: 4.6) *
58.7 ±0.2
68.7
Three, M4
(length: 13)
JIS B0202 G½
Effective thread:
4 threads min.
40 ±0.7
* Stainless sintered roller
Top-ball Plunger
WLD3
WL01D3
PT
±1.2
29.2
12.7
68.7
21.6
JIS B0202 G½
Four, M6
±1.2
(15.1)
Effective thread:
Depth: 15 min.
29.2
30.2 ±0.2
4 threads min.
35
40 ±0.7
*1. Stainless sintered roller
42 max.
*2. Cosmetic nuts
Note: The WLSD21 model, which has the roller rotated by 90° is also available.
(4.9)
Four, M6
Depth: 15 min.
35
42 max.
Horizontal-ball Plunger
WLSD3
25.4
WL01SD3
13.1
15.5 dia. 1/2 dia. *
12.9
PT
Four, M3.5
OP
46.6 ±0.8
13.1
12.7
27.5
Four, M3.5
OP
19.9
17.8
(96.2)
Four, 5.2 +0.2
0
dia. holes
58.7 ±0.2
58.7 ±0.2
68.7
Three, M4
(length: 13)
1/2 dia. *1
25 dia. *2
Four, 5.2 +0.2
0
dia. holes
Three, M4
(length: 13)
68.7
5
5
21.6
(4.9)
OP
55.7 ±0.8
13.1
Four, M3.5
17.5 dia.
(length: 4.6)*1
5
21.6
30.2 ±0.2
35
42 max.
25 dia. *2
Four, 5.2 +0.2
0
dia. holes
Three, M4
(length: 13)
(96.2)
5
(4.9)
Four, M6
Depth: 15 min.
17.8
28
Four, 5.2 +0.2
0
dia. holes
(15.1)
PT
±1.2
29.2
27.5
Four, M3.5
58.7 ±0.2
21.6
JIS B0202 G½
(15.1)
Effective thread:
30.2 ±0.2
4 threads min.
40 ±0.7
*1. Stainless steel plunger
*2. Cosmetic nuts
Horizontal-roller Plunger
WLSD2
25.4
WL01SD2
13.1
12.9
OP
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
JIS B0202 G½
Effective thread:
4 threads min.
±1.2
29.2
35
42 max.
Four, M6
Depth: 15 min.
(4.9)
* Stainless steel ball
Sealed Top-roller Plunger
WLD28
PT
WL01D28
JIS B0202 G½
(15.1)
Effective thread:
30.2 ±0.2
4 threads min.
40 ±0.7
*1. Stainless steel ball
*2. Cosmetic nuts
21.6
±1.2
29.2
Four, M6
Depth: 15 min.
35
42 max.
13.1
11.2 dia. (length: 5) *
12.9
Four, M3.5
OP
24
Four, 5.2 +0.2
0
dia. holes
58.7 ±0.2
68.7
Three, M4
(length: 13)
5
21.6
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
JIS B0202 G½
Effective thread:
4 threads min.
* Stainless steel roller
Model WLD
Operating characteristics
WL01D
OF
max.
Operating force
26.67 N
RF min.
Release force
8.92 N
Pretravel
PT max.
1.7 mm
Overtravel
6.4 mm
OT min.
Movement Differential MD max.
1 mm
OP
Operating Position
34 ±0.8 mm
Total travel Position
29.5 mm
TTP max.
±1.2
29.2
Four, M6
Depth: 15 min.
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all
dimensions.
35
42 max.
WLD2
WL01D2
WLD3
WL01D3
WLD28
WL01D28
WLSD2
WL01SD2
WLSD3
WL01SD3
40.03 N
8.89 N
2.8 mm
5.6 mm
1 mm
40.03 N
8.89 N
2.8 mm
4 mm
1 mm
26.67 N
8.92 N
1.7 mm
5.6 mm
1 mm
26.67 N
8.92 N
1.7 mm
4 mm
1 mm
16.67 N
4.41 N
1.7 mm
5.6 mm
1 mm
44 ±0.8 mm
39.5 mm
44.5 ±0.8 mm
41 mm
44 ±0.8 mm
39.5 mm
WLSD
WL01SD
40.03 N
8.89 N
2.8 mm
6.4 mm
1 mm
54.2 ±0.8 mm 54.1 ±0.8 mm 40.6 ±0.8 mm
—
—
—
29
WL/WLM
Basic
Flexible Rod ............ For all models WL@ indicates a standard-load model and WL01@ indicates a microload model.
Coil Spring
WLNJ
WL01NJ
PT
Coil Spring (Multi-wire)
WLNJ-30
PT
WL01NJ-30
6.5 dia.
*1
*2
*3
4.8 dia.
*1
*2
*3
(107)
13.1
13.1
(107)
140 ±2.5
140 ±2.5
32.7 ±0.8
32.7 ±0.8
Four, 5.2 +0.2
0
dia. holes
58.7 ±0.2
Four, 5.2 +0.2
0
dia. holes
68.7
Three, M4
(length: 13)
58.7 ±0.2
5
68.7
Three, M4
(length: 13)
5
21.6
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
JIS B0202 G½
Effective thread:
4 threads min.
21.6
Four, M6
Depth: 15 min.
±1.2
29.2
(4.9)
35
42 max.
Steel Wire
WLNJ-S2
WL01NJ-S2
8 dia.
*1
JIS B0202 G½
Effective thread:
4 threads min.
Four, M6
Depth: 15 min.
±1.2
29.2
35
42 max.
*1. The coil spring may be operated from any direction except the
axial direction (↓).
*2. Piano wire coil
*3. Optimum operating range of the coil spring is within 1/3 of the
entire length from the top end.
*1. The coil spring may be operated from any direction except the
axial direction (↓).
*2. Stainless steel coil spring
*3. Optimum operating range of the coil spring is within 1/3 of the
entire length from the top end.
Coil Spring (Resin Rod) PT
WLNJ-2
WL01NJ-2
*3
(15.1)
30.2 ±0.2
40 ±0.7
*2
PT
1 dia.
*1
*2
*3
(95.4)
13.1
(161)
26 dia.
13.1
193 ±2.5
140 ±2.5
32 ±0.8
44.6 ±0.8
Four, 5.2 +0.2
0
dia. holes
Four, 5.2 +0.2
0
dia. holes
58.7 ±0.2
58.7 ±0.2
68.7
Three, M4
(length: 13)
68.7
Three, M4
(length: 13)
5
5
21.6
21.6
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
JIS B0202 G½
Effective thread:
4 threads min.
±1.2
29.2
35
42 max.
Four, M6
Depth: 15 min.
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
JIS B0202 G½
Effective thread:
4 threads min.
±1.2
29.2
Four, M6
Depth: 15 min.
35
42 max.
*1. The resin rod may be operated from any direction except the axial
direction (↓).
*2. Polyamide resin rod
*3. Optimum operating range of the resin rod is within 1/3 of the
entire length from the top end.
*1. The steel wire may be operated from any direction except the
axial direction (↓).
*2. Stainless steel wire
*3. Optimum operating range of the steel wire is within 1/3 of the
entire length from the top end.
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Model WLNJ *
Operating characteristics
WL01NJ *
Operating force OF max.
1.47 N
PT
Pretravel
20 ±10mm
WLNJ-30 *
WL01NJ-30 *
1.47 N
20 ±10mm
WLNJ-2 *
WL01NJ-2 *
1.47 N
40 ±20mm
WLNJ-S2 *
WL01NJ-S2 *
0.28 N
40 ±20mm
* These values are taken from the top end of the wire or spring.
30
WL/WLM
Overtravel
General-purpose/High-sensitivity Models ........... For all models WL@ indicates a standard-load model and WL01@ indicates a microload model.
Roller Lever R38
WLH2
WL01H2
WLG2
WL01G2
17.5 dia. (length: 7) *
Four, M3.5
38R
60 max.
53 ±1.5
41.5 ±1.5
40 ±1.5
13.1
25.4
12.7
M5 (length: 12)
Allen-head bolt
9
Adjustable Rod Lever
WLHL
WL01HL
Adjustable range:
WLGL
25 to 140
WL01GL
25.4
14.7
M8 (length: 12)
Allen-head
lock screw
68.7
Three, M4
(length: 13)
25.4
M5 (length: 12)
Allenhead bolt
Four, 5.2 +0.2
0
dia. holes
Four, 5.2 +0.2
0
dia. holes
58.7 ±0.2
25.4
12.7
Four, M3.5
14.7
(125)
55 max.
46 ±1.5
41.5 ±1.5
13.1
3 ±0.2 dia.
(length: 160) *
58.7 ±0.2
68.7
Three, M4
(length: 13)
5
JIS B0202 G½
(15.1)
Effective thread:
(4.9)
30.2 ±0.2
4 threads min.
40 ±0.7
* Stainless sintered roller
21.6
±1.2
29.2
35
42 max.
53.2 ±0.8
5
Four, M6
Depth: 15 min.
17.5 dia. (length: 7) *
Four, M3.5
M5 (length: 16)
Allen-head
bolt
Four, 5.2 +0.2
0
dia. holes
14.7
67 max.
60 ±1.5
41.5 ±1.5
13.1
Adjustable Rod Lever
WLHAL4
WL01HAL4
25.4
12.7
Adjustable range:
350 to 380
25.4
3.2 dia. *
54.5 ±1.5
41.5 ±1.5
13 .1
8
12 .8
(15.1)
30.2 ±0.2
40 ±0.7
JIS B0202 G½
Effective thread:
4 threads min.
M5 (length: 12)
Allen-head
bolt
2 5 .4
Four, 5.2 +0.2
0
dia. holes
±1.2
29.2
35
42 max.
65.2 ±0.8
Four, M6
Depth: 15 min.
58.7 ±0.2
6 8 .7
Three, M4
(length: 13)
5
21.6
* Stainless sintered roller
(15.1)
30.2 ±0.2
40 ±0.7
* Stainless steel rod
Note: 1. WL@G12 is identical to other models except in
the shape of the set position marker plate.
2. The built-in switch for WLH12 is W-10FB3.
3. The built-in switch for WLG12 is W-10FB3-8.
Rod Spring Lever
WLHAL5
WL01HAL5
2 5 .4
12 .7
14 .7
21.6
(4.9)
Four, M6
Depth: 15 min.
68.7
Three, M4
(length: 13)
5
±1.2
Note: 1. WL@GL is identical to other models except in
the shape of the set position marker plate.
2. The built-in switch for WLHL is W-10FB3.
3. The built-in switch for WLGL is W-10FB3-8.
65
58.7 ±0.2
21.6
29.2
35
42 max.
* Stainless sintered roller
Note: 1. WL@G2 is identical to other models except in
the shape of the set position marker plate.
2. The built-in switch for WLH2 is W-10FB3.
3. The built-in switch for WLG2 is W-10FB3-8.
Adjustable Roller Lever
WLH12
WL01H12
Adjustable range:
WLG12
25 to 89
WL01G12
JIS B0202 G½
Effective thread:
4 threads min.
(15.1)
30.2 ±0.2
40 ±0.7
(4.9)
(4.9)
JIS B0202 G½
Effective thread:
4 threads min.
±1.2
2 9.2
Four, M6
Depth: 15 mi
35
42 max.
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all
dimensions.
7.7
2.3 dia. *
54 ±1.5
41.5 ±1.5
13 .1
428.5 ±2
65
11
M5 (length: 16)
Allen-head
bolt
25.4
12.7
25.4
14.7
Four, 5.2 +0.2
0
dia. holes
58.7 ±0.2
68.7
Three, M4
(length: 13)
OF and RF for WLH12 and WL01H12, with a lever length of
89 mm.
5
(15.1)
30.2 ±0.2
40 ±0.7
* Piano wire
(4.9)
JIS B0202 G½
Effective thread:
4 threads min.
Model WLH2
Operating characteristics
WL01H2
Operating force
OF max.
9.81 N
Release force
RF min.
0.98 N
Pretravel
PT
15° ±5°
Overtravel
OT min.
55°
Movement Differential MD max.
12°
21.6
±1.2
2 9.2
35
42 max.
WLG2
WL01G2
9.81 N
0.98 N
+2°
10°–1°
65°
7°
Four, M6
Depth: 15 min.
OF
RF
WLH12, WLA01H12
4.18 N
0.42 N
WLG12, WL01G12
4.18 N
0.42 N
WLH12 *1
WLG12 *1
WLHL *1
WLGL *2
WLHAL4 *3
WLHAL5
WL01H12 *1 WL01G12 *1 WL01HL *1 WL01GL *2 WL01HAL4 *3 WL01HAL5
9.81 N
9.81 N
2.84 N
2.84 N
0.98 N
0.90 N
0.98 N
0.98 N
0.25 N
0.25 N
0.15 N
0.09 N
+2°
+2°
15° ±5°
10° –1°
15° ±5°
10°–1°
15° ±5°
15° ±5°
55°
65°
55°
65°
55°
55°
12°
7°
12°
7°
12°
12°
Note: With WLHAL4, WL01HAL4, WLHAL5, and WL01HAL5, the actuator's tare is large, so depending on the installation direction, they may not be properly reset.
Always install so that the actuator is facing downwards.
*1. The operating characteristics of WLH12, WL01HL12, WLG12, and WL01G12 are measured at the lever length of 38 mm.
*2. The operating characteristics of WLHL, WL01HL, WLGL, and WL01GL are measured at the rod length of 140 mm.
*3. The operating characteristics of WLHAL4, and WL01HAL4 are measured at the rod length of 380 mm.
31
WL/WLM
Overtravel
Side-installation Models ... For all models WL@ indicates a standard-load model and WL01@ indicates a microload model.
60 max.
53 ±1.5
Roller Lever
WLCA2-2N
WL01CA2-2N
41.5 ±1.5
40 ±1.5
22
11 13.1
17.5 dia. (length: 7) *
Four, M3
38R
41.5 ±1.5
11.5
58.7 ±0.2
M5 (length: 12)
Allen-head bolt
64 ±0.2
23
21.6
68.7
Three, M4
(length: 13)
5
5
(15.1)
30.2 ±0.2
40 ±0.7
Four, 5.2 +0.2
0
dia. holes
58.7 ±0.2
±0.2
JIS B0202 G½
Effective thread:
4 threads min.
25.4
16.1
(126.5)
101.8
5
25.4
12.7
Four, M3.5
38R
(10.8)
M5 (length: 12)
Allen-head bolt
Four, 5.2 +0.2
0
dia. holes
Two, 5.2 +0.2
0
dia. holes
Three, M4
(length: 13)
40 ±1.5
13.1
17.5 dia. (length: 7) *
Two, M5
(length: 18)
16.1
(126.5)
(4.9)
60 max.
53 ±1.5
Roller Lever
WLCA2-2
WL01CA2-2
21.6
JIS B0202 G½
(15.1)
Effective thread:
30.2 ±0.2
4 threads min.
40 ±0.7
* Stainless sintered roller
5 Four, M6
Depth: 15 min.
±1.2
(4.9)
33 ±1.2
29.2
35
42 max.
35
* Stainless sintered roller
Four, M6
Depth: 15 min.
53.2 ±0.8
42 max.
Adjustable Roller Lever
WLCA12-2N
17.5 dia. (length: 7) *
WL01CA12-2N
67 max.
60 ±1.5
22
11 13.1
Four, M3
Adjustable range:
25 to 89
Adjustable Roller Lever
WLCA12-2
WL01CA12-2
41.5 ±1.5
17.5 dia. (length: 7) *
Adjustable range:
25 to 89
M5 (length: 16)
Allen-head bolt
(10.8)
Four, 5.2 +0.2
0
dia. holes
(4.9)
101.8
68.7
58.7 ±0.2
Three, M4
(length: 13)
Three, M4
(length: 13)
JIS B0202 G½
Effective thread:
4 threads min.
9
Adjustable range:
25 to 140
5
5
21.6
Four, M6
Depth: 15 min.
3 ±0.2 dia.
(length: 160) *
M8 (length: 12)
Allen-head
lock screw
Four, M3
Two, M5 (length: 18)
M5 (length: 12)
Allen-head bolt
Adjustable Rod Lever
WLCL-2
WL01CL-2
46 ±1.5
22
11 13.1
11.5
Adjustable range:
25 to 140
46 ±1.5
3 ±0.2 dia.
(length: 160) *
(15.1)
30.2 ±0.2
40 ±0.7
JIS B0202 G½
Effective thread:
4 threads min.
101.8
42 max.
68.7
Three, M4
(length: 13)
5
(4.9)
35
* Stainless steel rod
25.4
Four, 5.2 +0.2
0
dia. holes
58.7 ±0.2
33 ±1.2
25.4
12.7
M5 (length: 12)
Allen-head bolt
64 ±0.2
5 Four, M6
Depth: 15 min.
41.5 ±1.5
13.1
M8 (length: 12)
Four, M3.5 Allen-head
lock screw
16.1
±0.2
(4.9)
35
55 max.
(10.8)
23
21.6
Four, M6
Depth: 15 min.
42 max.
9
5
5
29.2
65.2 ±0.8
55 max.
Four, 5.2 +0.2
0
dia. holes
Two, 5.2 +0.2
0
dia. holes
Three, M4
(length: 13)
±1.2
(15.1)
30.2 ±0.2
40 ±0.7
JIS B0202 G½
Effective thread:
4 threads min.
* Stainless sintered roller
(4.9)
33 ±1.2
16.1
58.7 ±0.2
5
±0.2
23
21.6
35
42 max.
* Stainless sintered roller
Adjustable Rod Lever
WLCL-2N
WL01CL-2N
25.4
Four, 5.2 +0.2
0
dia. holes
Two, 5.2 +0.2
0
dia. holes
(15.1)
30.2 ±0.2
40 ±0.7
25.4
12.7
M5 (length: 16)
Allen-head bolt
16.1
64 ±0.2
58.7 ±0.2
5
41.5 ±1.5
13.1
Four, M3.5
11.5
Two, M5
(length: 18)
16.1
67 max.
60 ±1.5
(15.1)
30.2 ±0.2
40 ±0.7
JIS B0202 G½
Effective thread:
4 threads min.
21.6
±1.2
29.2
Four, M6
Depth: 15 min.
35
42 max.
* Stainless steel rod
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Model WLCA2-2N
WLCA12-2N *1
WLCL-2N *2
WLCA2-2
Operating characteristics WL01CA2-2N WL01CA12-2N *1 WL01CL-2N *2 WL01CA2-2
Operating force
OF max.
9.61 N
9.61 N
2.84 N
8.83 N
Release force
RF min.
1.18 N
1.18 N
0.25 N
0.49 N
Pretravel
PT
20° max.
20° max.
20° max.
25° ±5°
Overtravel
OT min.
70°
70°
70°
60°
Movement Differential MD max.
10°
10°
10°
16°
WLCA12-2 *1
WLCL-2 *2
WL01CA12-2 *1 WL01CL-2 *2
8.83 N
2.55 N
0.49 N
0.1 N
25° ±5°
25° ±5°
60°
60°
16°
16°
*1. The operating characteristics of WLCA12-2N and WL01CA12-2N are measured at the lever length of 38 mm.
*2. The operating characteristics of WLCL-2N and WL01CL-2N are measured at the rod length of 140 mm.
OF and RF for WLCA12-2N
and WL01CA12-2N, with a
lever length of 89 mm.
OF
RF
WLCA12-2N,
WLA01CA12-2N
4.10 N
0.50 N
32
WL/WLM
High-precision Models
WL@ are Standard Models and WL01@ are Microload Models.
Roller Lever
WLGCA2
WL01GCA2
60 max.
17.5 dia. (length: 7) *
53 ±1.5
41.5 ±1.5
40 ±1.5
13.1
25.4
12.7
Four, M3.5
38R
(125)
M5 (length: 12)
Allen-head bolt
Model WLGCA2
Operating characteristics
WL01GCA2
Operating force
OF max.
13.34 N
Release force
RF min.
1.47 N
+2°
Pretravel
PT
5° 0°
Overtravel
OT min.
40°
Movement Differential MD max.
3°
25.4
14.7
Four, 5.2 +0.2
0
dia. holes
68.7
58.7 ±0.2
Three, M4
(length: 13)
5
(4.9)
JIS B0202 G½
Effective thread:
4 threads min.
(15.1)
30.2 ±0.2
40 ±0.7
* Stainless sintered roller
21.6
±1.2
29.2
Four, M6
Depth: 15 min.
35
42 max.
53.2 ±0.8
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Sensor I/O Connector Switches
Direct-wired Connector/Pre-wired Connector Models
Refer to page 17 for the connecting cable.
Roller Lever Plungers ....... WL@ are Standard Models and WL01@ are Microload Models.
Standard Models (WLCA2), High-precision Models (WLGCA2),
Overtravel General-purpose Models (WLH2), Overtravel High-sensitivity Models (WLG2)
Connector Models
Pre-wired Connector Models
60 max.
17.5 dia. (length: 7) *
38R
Four, M3.5
53 ±1.5
41.5 ±1.5
40 ±1.5
13.1
17.5 dia. (length: 7) *
38R
25.4
12.7
25.4
25.4
M5 (length: 12)
Allen-head bolt
Four, 5.2 +0.2
0
dia. holes
68.7
58.7 ±0.2
Three, M4
(length: 13)
Four, 5.2 +0.2
0
dia. holes
68.7
58.7 ±0.2
(15.1)
30.2 ±0.2
40 ±0.7
* Stainless sintered roller
(20)
Four, M6
21.6 Depth: 15 min.
M12 × 1
(4.9)
5
Three, M4
(length: 13)
5
12.5
±1.2
JIS B0202 G½
Effective thread:
4 threads min.
25.4
12.7
Four, M3.5
M5 (length: 12)
Allen-head bolt
14.7
14.7
60 max.
53 ±1.5
41.5 ±1.5
40 ±1.5
13.1
Four, M6
Depth: 15 min.
SC-1M
+100
300 -50
29.2
35
42 max.
6 dia.
53.2 ±0.8
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
XS2H-D421
M12 × 1
* Stainless sintered roller
21.6
±1.2
29.2
35
42 max.
53.2 ±0.8
Note: 1. Only the dimension of the set position marker plate is different for WLG2 Models.
2. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
3. The models with operation indicators are shown in the above diagrams.
Actuator
Operating characteristics
Operating force
OF max.
Release force
RF min.
Pretravel
PT
Overtravel
OT min.
Movement Differential MD max.
Standard roller lever
actuator
13.34 N
2.23 N
15° ±5°
30°
12°
High-precision roller
lever actuator
13.34 N
1.47 N
+2°
5° 0°
40°
3°
Overdrive generalpurpose actuator
9.81 N
0.98 N
15° ±5°
55°
12°
Overdrive high-sensitivity
actuator
9.81 N
0.98 N
+2°
10° 0°
65°
7°
33
WL/WLM
Top-roller Plunger (WLD2)
Direct-wired Connector Models
Pre-wired Connector Models
13.1
PT
17.5 dia. (length: 4.6) *
12.9
13.1
PT
OP
12.9
17.5 dia. (length: 4.6) *
28
Four, 5.2 +0.2
0
dia. holes
Four, M3.5 (length: 10)
OP
Four, M3.5 (length: 10)
28
68.7
58.7 ±0.2
Three, M4
(length: 13)
Four, 5.2 +0.2
0
dia. holes
5
68.7
58.7 ±0.2
(20)
Three, M4
(length: 13)
5
12.5
Four, M6
Depth: 15 min.
SC-1M
M12 × 1
JIS B0202 G½
Effective thread:
4 threads min.
(15.1)
30.2 ±0.2
40 ±0.7
(4.9)
* Stainless sintered roller
21.6 Four, M6
Depth: 15 min.
±1.2
29.2
300 +100
-50
6 dia.
35
42 max.
XS2H-D421
(15.1)
30.2 ±0.2
M12 × 1
40 ±0.7
* Stainless sintered roller
(4.9)
21.6
±1.2
29.2
35
42 max.
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
2. The following diagrams are for a indicator-equipped models.
Actuator
Operating characteristics
Operating force
OF max.
Release force
RF min.
Pretravel
PT max.
Overtravel
OT min.
Movement Differential MD max.
Operating Position
OP
Total travel Position
TTP max.
Top-roller plunger
26.67 N
8.92 N
1.7 mm
5.6 mm
1 mm
44 ±0.8mm
39.5 mm
Indicator-equipped Models
60 max.
Roller Lever
WLCA2-LE/LD
WL01CA2-LE/LD
53 ±1.5
41.5 ±1.5
17.5 dia. (length: 7) *
38R
40 ±1.5
13.1
25.4
12.7
Four, M3.5
25.4
M5 (length: 12)
Allen-head bolt
14.7
(125)
Four, 5.2 +0.2
0
dia. holes
68.7
58.7 ±0.2
Three, M4
(length: 13)
5
21.6
(15.1)
30.2 ±0.2
40 ±0.7
JIS B0202 G½
Effective thread:
4 threads min.
* Stainless sintered roller
(4.9)
±1.2
29.2
Four, M6
Depth: 15 min.
35
42 max.
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Actuator WLCA2-LE/LD
WL01CA2-LE/LD
Operating characteristics
Operating force
OF max.
13.34 N
Release force
RF min.
2.23 N
Pretravel
PT
15° ±5°
Overtravel
OT min.
30°
Movement Differential MD max.
12°
34
WL/WLM
Spatter-prevention Models
Roller Lever (Screw Terminals)
WLCA2-@S/WL01@-@S
WLH2-@S/WLG2-@S
WLGCA2-@S
Roller Lever (Pre-wired connectors)
WLCA2-@S-M1J*/WL01@-@S-M1J*
WLH2-@S-M1J*/WLG2-@S-M1J*
WLGCA2-@S-M1J*
* External dimensions are the same even for different core
wires.
60 max.
17.5 dia. (length: 7) *
Four, M3.5
head clamping screws
Two, M5 Allen-head nut
and arm set screw
38R
(125)
60 max.
54 ±1.5
13.1
25.4
12.7
Four, M3.5
head clamping screws
Two, M5 Allen-head nut
and arm set screw
38R
25.4
Four, 5.2 +0.2
0
dia. holes
Fluororesin cap
14.7
17.5 dia. (length: 7) *
53 ±1.5
41.5 ±1.5
40 ±1.5
13.1
25.4
12.7
25.4
Four, 5.2 +0.2
0
dia. holes
14.7
Fluororesin cap
68.7
58.7 ±0.2
68.7
Three, M4
(length: 13)
58.7 ±0.2
Lamp cover
Lamp cover
5
5
Three, M4
(length: 13)
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
JIS B0202 G½
Effective thread:
4 threads min.
21.6
±1.2
29.2
(20)
Four, M6
Depth: 15 min.
Four, M6
Depth: 15 min.
SC-1M
35
42 max.
300 +100
−50
* Stainless steel roller
6 dia.
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
21.6
XS2H-D421
±1.2
29.2
35
42 max.
53.2 ±0.8
* Stainless steel roller
Sealed Top-roller Plunger (Screw Terminals)
WLD28-@S
Sealed Top-roller Plunger (Pre-wired connectors)
WLD28-@S-M1J*
* External dimensions are the same even for different core wires.
11.2 dia. (length: 5) *
Rubber cap
(Fluorosilicone)
Four, M3.5 (length: 10)
Mounting bushing
Tightening screws
and spring washers
PT
13.1
PT
11.2 dia. (length: 5) *
12.9
OP
Four, M3.5
OP
58.7 ±0.2
68.7
58.7 ±0.2
(4.9)
Three, M4
(length: 13)
(15.1)
30.2 ±0.2
40 ±0.7
JIS B0202 G½
Effective thread:
4 threads min.
68.7
5
(20)
Lamp cover
5
12.9
Four, 5.2 +0.2
0
dia. holes
Three, M4
(length: 13)
Lamp cover
24
Four, 5.2 +0.2
0
dia. holes
13.1
21.6
±1.2
29.2
Four, M6
Depth: 15 min.
SC-1M
Four, M6
Depth: 15 min.
300 +100
−50
35
42 max.
6 dia.
* Stainless steel roller
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
XS2H-D421
* Stainless steel roller
21.6
±1.2
29.2
35
42 max.
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
Actuator
Operating characteristics
Operating force
OF max.
Release force
RF min.
Pretravel
PT
Overtravel
OT min.
Movement Differential MD max.
Operating Position
OP
Total travel Position
TTP max.
Basic
13.34 N
2.23 N
15° ±5°
30°
12°
—
—
Roller Lever
Overtravel models
General-purpose High-sensitivity
9.81 N
9.81 N
0.98 N
0.98 N
+2°
15° ±5°
10°–1°
55°
65°
12°
7°
—
—
—
—
High-precision
Sealed Top-roller
Plunger
13.34 N
1.47 N
+2°
5° 0°
40°
3°
—
—
16.67 N
4.41 N
1.7 mm max.
5.6 mm
1 mm
44 ±0.8 mm
39.5 mm
35
WL/WLM
Long-life Models
Rotating Lever Models
Roller Lever (Screw Terminals)
WLM@-LD
17.5 dia. (length: 7) *
Four, M3.5
(length: 26.5)
M5 (length: 12)
Allen-head bolt
38R
Roller Lever (Direct-wired Connectors)
WLM@-LD@
60 max.
53 ±1.5
41.5 ±1.5
40 ±1.5
13.1
38R
25.4
Four,
dia. holes
14.7
Rubber cap
58.7 ±0.2
58.7 ±0.2
Lamp cover
21.6
(4.9)
±1.2
(15.1)
30.2 ±0.2
40 ±0.7
29.2
* Stainless sintered roller
JIS B0202 G½
Effective thread:
4 threads min.
17.5 dia. (length: 7) *
38R
68.7
Lamp cover
Four, M6
21.6 Depth: 15 min.
SC-2FD
35
42 max.
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
* Stainless sintered roller
±1.2
29.2
M12 x 1
JIS B0202 G½
Effective thread:
4 threads min.
35
42 max.
53.2 ±0.8
60 max.
53 ±1.5
41.5 ±1.5
40 ±1.5
13.1
Four, M3.5
(length: 26.5)
M5 (length: 12)
Allen-head bolt
25.4
12.7
25.4
Four, 5.2 +0.2
0
dia. holes
14.7
25.4
Three, M4
(length: 13)
5
12.5
Four, M6
Depth: 15 min.
53.2 ±0.8
Roller Lever (Pre-wired Connectors)
WLM@-LD@
M5 (length: 12)
Allen-head bolt
Four, 5.2 +0.2
0
dia. holes
Rubber cap
68.7
Three, M4
(length: 13)
5
25.4
12.7
Four, M3.5
(length: 26.5)
5.2 +0.2
0
14.7
41.5 ±1.5
40 ±1.5
13.1
17.5 dia. (length: 7) *
25.4
12.7
60 max.
53 ±1.5
Rubber cap
Three, M4
(length: 13)
58.7 ±0.2
68.7
Lamp cover
(20)
Four, M6
Depth: 15 min.
5
XS2H-D421
300 ±50
44.7
6 dia.
21.6
(4.9)
(15.1)
30.2 ±0.2
40 ±0.7
* Stainless sintered roller
Model
Operating characteristics
Operating force
OF max.
Release force
RF min.
Pretravel
PT
Overtravel
OT min.
Movement Differential MD max.
±1.2
29.2
35
42 max.
53.2 ±0.8
WLMCA2-LD@
Basic models
9.81 N
0.98 N
15° ±5°
30°
12°
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all
dimensions.
WLMH2-LD@
General-purpose
overtravel models
9.81 N
0.98 N
15° ±5°
55°
12°
WLMG2-LD@
High-sensitivity overtravel
models
9.81 N
0.98 N
+2°
10°–1°
65°
7°
WLMGCA2-LD@
High-precision models
13.34 N
1.47 N
+2°
5° 0°
40°
3°
36
WL/WLM
Actuators (Levers Only)
Lever: Only rotating lever models are illustrated.
WL-1A100
Standard Lever
WL-1A115
Resin Roller
17.9
17.5 dia. (length: 7)
stainless sintered roller
7.3-dia.
mounting
holes
12.6
M5
Allen-head bolt 11.4
16
WL-1A105
Double Nuts
7.3-dia.
mounting
holes
38 54.8
M5
Allen-head bolt 11.4
16
17.9
12.6
7.3-dia.
mounting
holes
38 54.8
Two, M5 Allenhead nut and
arm set screw
WL-1A200
Lever Length: 50
Roller Width: 15
12.6
24.9 ±0.8
19.7 ±0.8
Adjustable lever:
stainless steel
24.9 ±0.8
19.7 ±0.8
17.5 dia. (length: 7)
resin roller
Adjustable lever:
stainless steel
M5
Allen-head bolt 11.4
17.9
12.6
M5
Allen-head bolt 11.4
WL-2A108
Resin Roller
24.9 ±0.8
M5
17.5 dia. (length: 7) Allen-head 19.7 ±0.8
resin roller
bolt
Adjustable lever:
stainless steel
23
Adjustable
range:
25 to 140
23
Adjustable
range:
25 to 89
105.75
7.3-dia.
mounting
holes
7.3-dia.
mounting
holes
7.3-dia.
mounting
holes
M5
Allen-head
bolt
M5
Allen-head
bolt
12
16
12
16
63 ±0.3 79.8
16
17.5 dia. (length: 7)
24.9 ±0.8
stainless sintered M5
roller
Allen-head 19.7 ±0.8
bolt
Adjustable lever:
stainless steel
105.75
105.75
7.3-dia.
mounting
holes
7.3-dia.
mounting
holes
50 66.8
WL-2A107
Double Nuts
Adjustable
range:
25 to 89
Adjustable
range:
25 to 89
17.5 dia. (length: 7)
stainless sintered roller
25.7
16.6
M5
Allen-head bolt 11.4
WL-2A111
Resin Roller
17.5 dia. (length: 7)
stainless sintered roller
M5
Allen-head bolt 11.4
WL-1A300
Lever Length: 63
17.5 dia. (length: 15)
stainless sintered roller
16
WL-2A100
23.6
54.8
7.3-dia.
mounting
holes
16
M5
Allen-head bolt 11.4
40.2 ±0.8
38 ±0.2 54.8
16
11.4
12.1
R38
7.3-dia.
mounting
holes
16
17.5 dia. (length: 30)
Nylon roller
16.9
38 54.8
16
17.9
17.5 dia. (length: 7)
stainless steel roller
WL-1A118
Nylon Roller:
Roller Width: 30 mm
17 dia. (length: 6)
bearing roller
12.6
WL-1A103S
Spatter Prevention
17.5 dia. (length: 7)
stainless sintered roller
7.3-dia.
mounting
holes
17.9
17.5 dia. (length: 7)
resin roller
7.3-dia.
mounting
holes
38 54.8
WL-1A400
Bearing Roller
155.75
Two, M5 Allen-head nut
and arm set screw
12
16
6.2
(15.8)
WL-2A122
WL-2A106
24.9 ±0.8
17.5 dia. (length: 7) M5
stainless sintered Allen-head 19.7 ±0.8
roller
bolt
Adjustable lever:
stainless steel
23
Adjustable
range:
25 to 140
7.3-dia.
mounting
holes
WL-2A130
WL-2A104
24.9 ±0.8
19.7 ±0.8
17.5 dia. (length: 7)
stainless sintered
roller
9.1
Adjustable lever:
stainless steel
24.7 ±0.8
19.5 ±0.8
17.5 dia. (length: 7)
stainless sintered
roller
24.9 ±0.8
50 dia. (length: 6)
Nylon roller
19.7 ±0.8
3
(21.8)
23
Adjustable
range:
25 to 89
(10)
89.5R
(10)
105.75
(112)
Three,
dia. holes
7.3 dia.
mounting holes
155.75
7.3-dia.
mounting
holes
M5
Allen-head
bolt
16
20
* Can be installed
on the rear side.
6.2
(15.8)
Adjustable
from 42 to 89
5.3+0.2
0
15.9
20
Two, M5
(length: 16)
Allen-head bolt
7.3-dia.
mounting
holes
22.1
M5
Allen-head
bolt
12
16
23
Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
37
WL/WLM
Lever: Only rotating lever models are illustrated.
WL-2A110
WL-2A105
34.5
50 dia. (length: 15)
Nylon roller
Adjustable
from 41 to
78.5
24.4
23
122
M5
Allen-head
bolt
7.3-dia.
mounting
holes
WL-1A106
34.2
WL-1A110
24.2
49 dia. rubber roller
Material: NBR
6
50 dia. (length: 6)
Nylon roller
20.1 ±0.8
35 dia. (length: 6)
Nylon roller
20.1 ±0.8
38R
Adjustable
from 41 to
89
38R
M5
Allen-head
16
bolt
7.3-dia.
mounting
holes
M5
Allen-head 16
bolt
11.5
7.3+0.1
0 -dia.
mounting holes 11.5
M5
Allen-head
bolt
7.3-dia.
mounting
holes
16
16
WL-4A100
WL-4A201
9
9
3-dia. stainless
steel rod
7.3-dia. mounting
holes
M5
Allen-head
bolt
Adjustable
from
25 to 140
160
WL-3A100
Adjustable
from 270 to
290
2-dia. stainless
steel for spring
Adjustable
from 350
to 380
7.3-dia.
mounting
holes
M5
Allen-head
bolt
13
19
M8
Allen-head
lock screw
Adjustable
from 350
to 380
8
Actuator's
center of
rotation
11
WL-3A200
11 65 ±2
7.5
6
7.3-dia.
mounting
holes
11 65 ±2
7.5
6
M5
13.4
Allen-head
bolt
25.5 max.
12.8
WL-3A203
7.3-dia.
mounting
12.8
holes
2.3-dia.
operation rod
9
Cap
437.5 ±2
450 ±4
12.5 dia. max.
4-dia. stainless
steel rod
7.3-dia.
mounting holes
7.3-dia.
mounting
12.8
holes
M5
Allen-head
bolt
2.3-dia.
operation
rod
11
7.5
6
13.4
25.5 max.
WL-2A129
15.8
Marking
7.3-dia.
mounting 7.5
holes
M5
Allen-head
bolt
Three, 5.3 +0.2
0
dia. holes
7.3 +0.1
0 dia.
mounting
holes
10
20
19
M8
Allen-head
lock screw
11
7.5
6
13
7.3-dia.
mounting
holes
24.6 max.
WL-5A101
M5
Allen-head
bolt
11
13
24.6 max.
WL-5A103
Two, 17.5 dia. (length: 7)
stainless sintered rollers
6.7
WL-5A105
17.7
Two,M5
(length: 16) 22.1
Allen-head bolts
Two, 17.5 dia. (length: 7)
stainless sintered rollers
12.4
90°
38R
54.8
WL-5A100 has a plastic roller
Two, 17.5 dia. (length: 7)
stainless sintered rollers
17.7 6.7
12.4
17.7
12.4
1.3
90°
90°
7.3 dia.
M5 (length: 16)
Allen-head bolt 11
11.3
15.9
160
12.5
dia.
max.
(95)
1.3
10
M5
Allen-head
bolt
3
8R
(18.5)
84
95.3
(108)
Adjustable
up to 141
Adhesive
470 ±4
(95)
11 65 ±2
7.5
6
13.4
25.5 max.
WL-4A112
417.5 ±2
8 ±0.4
680
Two, M5 Allenhead nut and
arm set screw
8 dia.
50
Adjustable
from 650
to 660
8
400 ±2
11
3.2-dia.
stainless
steel rod
3.2-dia.
stainless
steel rod
400 ±2
M8
Allen-head
lock screw
WL-3A108
WL-3A106
Double Nut
3.2-dia.
stainless
steel rod
7.3 dia.
38R
54.8
M5 (length: 16)
Allen-head bolt 11
WL-5A102 has a plastic roller
7.3 dia.
38R
54.8
M5 (length: 16)
Allen-head bolt 11
WL-5A104 has a plastic roller
Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions.
2. When using the adjustable roller (rod) lever, make sure that the lever is facing downwards. Use caution, as telegraphing (the Switch turns ON and OFF
repeatedly due to inertia) may occur.
38
WL/WLM
Safety Precautions
Refer to Safety Precautions for All Limit Switches.
• When a rod or wired-type actuator is used, do not touch the top end
of the actuator. Doing so may result in injury.
(Applicable models)
WLHAL5 and WL01HAL5 Rod Spring Levers and WLNJ-S2 and
WL01NJ-S2 Steel-wire Actuators.
• A short-circuit may cause damage to the Switch, so insert a circuit
breaker fuse, of 1.5 to 2 times the rated current, in series with the
Switch.
• In order to meet EN approval ratings, use a 10-A fuse that
corresponds to IEC60269, either a gI or gG for general-purpose
types and spatter-prevention models only.
Precautions for Correct Use
• When wiring terminal screws, use M4 round crimp terminals and
tighten screws to the recommended torque. Wiring with bare wires,
or incorrect crimp terminals, or not tightening screws to the
recommended torque can lead to short-circuits, leakage current,
and fire.
• When performing internal wiring there is a chance of short-circuit,
leakage current, or fire, so be sure to protect the inside of the
Switch from splashes of oil or water, corrosive gases, and cutting
powder.
• Using an inappropriate connector or assembling Switches
incorrectly (assembly, tightening torque) can result in malfunction,
leakage current, or fire, so be sure to read the instruction manual
thoroughly beforehand.
• Even when the connector is assembled and set correctly, the end
of the cable and the inside of the Switch may come in contact. This
can lead to malfunction, leakage current, or fire, so be sure to
protect the end of the cable from splashes of oil or water and
corrosive gases.
Using Switches for Micro Loads
Contact faults may occur if a Switch for a general-load is used to
switch a micro load circuit. Use switches in the ranges shown in the
diagram below. However, even when using micro load models within
the operating range shown here, if inrush current occurs when the
contact is opened or closed, it may increase contact wear and so
decrease durability. Therefore, insert a contact protection circuit
where necessary. The minimum applicable load is the N-level
reference value. This value indicates the malfunction reference level
for the reliability level of 60% (λ60).
The equation, λ60 = 0.5 × 10–6/operations indicates that the estimated
malfunction rate is less than 1/2,000,000 operations with a reliability
level of 60%.
Voltage (V)
Precautions for Safe Use
5 mW
800 mW
0.16 mA
30
26 mA
24
Operating range
for micro-load
models
Operating range
for standard
models
12
Unusable
range
5
1 mA
100 mA 160 mA
0
0.1
1
10
100
1,000
Current (mA)
Operating Environment
• Seal material may deteriorate if a Switch is used outdoor or where
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
• Install Switches where they will not be directly subject to cutting
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
Not Suitable
Suitable
• Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
• The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near the
Switch, suppress arcing with contact protective circuits (surge
killers) or remove the source of silicon gas.
39
WL/WLM
Built-in Switch
Connectors
Do not remove or replace the built-in switch. If the position of the builtin switch moves, it can cause reduced performance, and if the
insulation sheet moves (separator), the insulation may become
ineffective.
Either the easy-to-use Allen-head nut or the SC Connector can be
used as connectors. To ensure high-sealing properties, use the SC
Connector. Refer to Limit Switch Connectors for details on SC
Connectors.
Tightening Torque
Wiring
• If screws are too loose they can lead to an early malfunction of the
Switch, so ensure that all screws are tightened using the correct
torque.
• In particular, when changing the direction of the Head, make sure
that all screws are tightened again to the correct torque. Do not
allow foreign objects to fall into the Switch.
• Use 1.25-mm2 lead wires and M4-insulation covered crimp
terminals for wiring.
Crimp Terminal External
Dimensions
L
Type
1.
3.
1.
6.
2.
4.
3.
2.
5.
4.
5.
Head mounting
screw
Cover mounting
screw
Allen-head bolt
(for securing the
lever)
Terminal screw
Connector
Appropriate
tightening
torque
0.78 to 0.88 N·m
1.18 to 1.37 N·m
4.90 to 5.88 N·m
0.59 to 0.78 N·m
1.77 to 2.16 N·m
Ground terminal
F
l
No.
Wiring Method
Switch Box Section
D dia.
B
dz dia. : 4.3
D dia. : 4.5
B
: 8.5
L
: 21.0
F
: 7.8
l
: 9.0 (mm)
dz dia.
NO terminal
NC terminal
• The ground terminal is only installed on models with ground
terminals.
Rotating Lever Set Position (General-purpose or Spatterprevention Switches Only)
Installing the Switch
To install the Switch, make a mounting panel, as shown in the
following diagram, and tighten screws using the correct torque.
Mounting
Mounting
Mounting
locations
WL
All rotating lever models, except the fork lever lock models, have a set
position marker plate. (See page 23.) After operation, set the indicator
needle on the marker plate so that is in the convex section of the
bearing.
Operation Set Position (Long-life Switches Only)
For all Long-life Switching, there is a set position marker slit on the
rubber cap of the head. After operation, set the slit on the rubber cap
so that the fluorescent color on the shaft section can be seen.
Front Mountig : Four, 5.2 +0.2
0 dia. holes
or M5 tapped holes
Rear Mountig : Four, 6.2 +0.2
0 dia. holes
Terminal Plate
Front Mountig/
Rear Mountig
By using a short circuit plate, as shown in the following diagram, the
Switch can be fabricated into a single-polarity double-break switch.
When ordering, specify WL Terminal Plate (product code: WL9662F).
58.7 ±0.15
30.2 ±0.15
9
2.5 +0.2
0
In case of side mounting for
overtravel,90° WL@-@@2N
7.1
Mounting
locations
3R
9 ±0.2
COM
Two, 5.2 +0.2
0 dia. holes
16 ±0.15 23 ±0.4
7
Side Mountig
3.5
2.1R
64 ±0.15
2R
4.2 +0.1
0
t = 0.6 Brass plate
Indicator
23 ±0.15
Indicator-equipped switch has contacts and indicator in parallel.
When contacts are open, leakage current flows through the indicator
circuit and may cause load's malfunction.
Please check the load's OFF current before use the indicatorequipped switch.
40
WL/WLM
Using the Switches
Item
Applicable models and Actuators
Changing the Installation Position
of the Actuator
By loosening the Allen-head bolt on the
actuator lever, the position of the actuator can be set anywhere within the 360°.
With Indicator-equipped Switches, the
actuator lever comes in contact with the
top of the indicator cover, so use caution
when rotating and setting the lever.
When the lever only moves forwards and
backwards, it will not contact the lamp
cover (except for long-life models).
Roller Levers:
WLCA2, WL01CA2, WLCA2-2,
WL01CA2-2, WLH2,WL01H2, WLG2,
WL01G2, WLMCA2@, WLMH2@,
WLMG2@, WLMGCA2@
Adjustable Roller Levers:
WLCA12, WL01CA12, WLCA12-2,
WL01CA12-2, WLH12, WL01H12,
WLG12, WL01G12,
Adjustable Rod Levers:
WLCL, WL01CL, WLCL-2, WL01CL-2,
WLHL, WL01HL, WLGL, WL01GL
Changing the Orientation of the Head
By removing the screws in the four corners of the Head, the Head can be set
in any of the four directions. Be sure to
change the plunger for internal operations at the same time. (The operational plunger does not need to be
changed on general-purpose and highsensitivity overtravel models.) The roller plunger can be set in either two positions at 90°.
WLCA2-2N and WL01CA2-2N can be
set only in either the forward or backward direction.
Roller Levers:
WLCA@, WL01CA@, WLCA@-2,
WL01CA@-2, WLGCA@, WLH@,
WL01H@, WLG@, WL01G@,
WLMCA2@, WLMH2@, WLMG2@,
WLMGCA2@
Adjustable Rod Levers:
WLCL, WL01CL, WLCL-2, WL01CL-2
Horizontal Plungers:
WLSD@, WL01SD@
Top-roller Plungers:
WLD2, WL01D2
Sealed Top-roller Plungers:
WLD28, WL01D28
Does not include -RP60 Series or -141
Series.
Details
Loosen the M5 × 12 bolt, set
the actuator's position and then
tighten the bolt again.
Head
Head
Loosen the screws.
Loosen the screws.
One-side Operation for General-purpose and High-precision Switches
The output of the Switch will be
changed, regardless of which
direction the lever is pushed.
The output of the Switch will
only be changed when the lever
is pushed in one direction.
Operating Operating Not operating Operating Operating
Not operating
Operational
plunger
Operation in both
directions
Changing the Operating Direction
By removing the Head on models
which can operate on one-side only,
and then changing the direction of the
operational plunger, one of three operating directions can be selected. For
overtravel 90° operation models, one
of three operating directions can be selected by loosening the rubber holder
using either a coin or a flat-blade
screwdriver and changing the direction
of the internal rubber section.
The tightening torque for the screws on
the Head is 0.78 to 0.88 N•m.
Clockwise operation
Counterclockwise
operation
Cam Direction Changing Procedure for Overtravel, 90° Operation Switches
Roller Levers:
WLCA2, WL01CA2, WLGCA2,
WLMGCA2@
Adjustable Roller Levers:
WLCA12, WL01CA12
Adjustable Rod Levers:
WLCL, WL01CL
Overtravel Models:
WLCA@-2N, WL01CA@-2N
Loosen the cam holder with a
coin or screwdriver. Take out
the cam from the Switch.
Change the direction of the cam as
required by your intended operation
and then reinstall the cam.
Relationship of cam to operation as observed from the rear of Switch
Operation on both sides
Operates
Operates
Operation on one side
Does not
operate
Operation on one side
Operates
Does not operate
Avoid this combination
Operates
41
WL/WLM
Item
Applicable models and Actuators
Installing the Roller on the Inside
By installing the roller lever in the opposite direction, the roller can be installed on the inside. (Set so that
operation can be completed within a
180° level range.)
Roller Levers:
WLCA@, WL01CA@, WLH@, WLCA@-2, WL01CA@-2, WLMCA2@,
WLMH2@, WLMG2@, WLMGCA2@,
WLG@, except for the adjustable roller
levers.
Fork Lever Locks:
WLCA32-4@, WL01CA32-4@
Selecting the Roller Position
There are four types of fork lever lock
for use depending on the roller position.
Details
Loosen the
Allen-head bolt.
Fork Lever Locks:
WLCA32-4@, WL01CA32-4@
WLCA32-41
WLCA32-43
WLCA32-42
WLCA32-44
Note: An explanation of the operation of fork lever locks is provided after
this table.
WLCA12 etc.
Adjusting the Length of the Rod or
Lever
The length of the rod or lever can be
adjusted by loosening the Allen-head
bolt.
Adjustable Roller Levers:
WLCA12, WL01CA12 etc.
Adjustable Rod Levers:
WLCL, WL01CL, etc.
Adjustment range radius:
25 to 89 mm
Loosen this
Allen-head bolt
and adjust the
length of the
lever.
Loosen this
Allen-head bolt
and adjust the
length of the rod.
Operation of Fork Lever Locks
The fork lever lock is configured so that the dog pushes the lever to reverse the output and this reversed state is maintained even after
the dog continues on. If the dog then pushes the lever from the opposite direction, the lever will return to its original position.
Example
NC terminal: ON
NO terminal: ON
NO terminal: ON
42
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2015.6
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2015 All Right Reserved.