MBR20U100CT(TO-220)2015.10 f02

MBR20U100CT
20A Ultra Low VF Trench MOS Schottky Rectifiers - 100V
PRIMARY CHARACTERISTICS
IO
10A×2
VRRM
V
IFSM
0A
VF@A, TJ=125°C
0.V
TJ Max
150℃
TO-220
PACKAGE
● Body Marking Example
VYM
Logo
Date Code
MBR208CT
Marking Code
Equivalent Circuit Diagram
(Samples are usually not indicated Date Code )
V:Product Lines
Y:AD late code, EX : 3-2013,4-2014
M:Month, EX : 1-1,2-2,---10-O,11-N,12-D
FEATURES
MECHANICAL DATA

EXTREMELY LOW VF

CASE:TRANSFER MOLDED,TO-220

TRENCH MOS SCHOTTKY

LEADS:SOLDERABLE PER MIL-STD-202,
METHOD 208
TECHNOLOGY

LOW POWER LOSS / HIGH

POLARITY:AS MARKED
EFFICIENCY

TERMINALS:PURETIN PLATED

HIGH FREQENCY OPERATION

HALOGEN FREE

HIGH FORWARD SURGE
CAPABILITY

MOISTURE SENSITIVITY LEVEL 1
MAXIMUM RATINGS (T A =25℃ UNLESS OTHERWISE NOTED ) AND ELECTRICAL CHARACTERISTICS
RATINGS
SYMBOL
MBR20U100CT
MAXIMUM RECURRENT PEAK REVERSE VOLTAGE
MAXIMUM RMS VOLTAGE
MAXIMUM DC BLOCKING VOLTAGE
MAXIMUM AVERAGE FORWARD RECTIFIED CURRENT
SEE FIG.1
PER LEG
PEAK FORWARD SURGE CURRENT, 8.3ms SINGLE HALF
SINE-WAVE SUPERIMPOSED ON RATED LOAD PER LEG
OPERATING JUNCTION TEMPERATURE RANGE
STORAGE TEMPERATURE RANGE
VRRM
VRMS
VDC
IO
IFSM
A
A
- 55 TO + 150
- 55 TO + 175
SYMBOL
MAXIMUM FORWARD VOLTAGE AT IF= 10A
TJ =25℃
TJ =125℃
T J =25℃
AT IF= 15A
TJ =125℃
MAXIMUM REVERSE CURRENT V R = VRRM @TJ =25℃ PER LEG (NOTE 1)
MAXIMUM REVERSE CURRENT V R = VRRM @TJ =125℃ PER LEG (NOTE 1)
V
V
V
200
TJ
TSTG
RATINGS
UNITS
100
70
100
20
10
VF
IR
℃
℃
MIN
TYP
M AX
UNITS
-----
-0.
--0.1
20
0.
0.
.
0.
V
mA
TYPICAL THERMAL RESISTANCE JUNCTION TO CASE PER LEG
Rθjc
2.2
℃/W
ISOLATION VOLTAGE(ITO-220 ONLY)FROM TERMINAL TO
HEATSINK T=1MIN
VAC
/
V
NOTES ︰ 1. PULSE TEST: 300µS PULSE WIDTH, 1% DUTY CYCLE.
2015.10
www.willas.com.tw
Rev.f 02
P1
MBR20U100CT
20A Ultra Low VF Trench MOS Schottky Rectifiers - 100V
RATINGS AND CHARACTERISTIC CURVES
FIG. 2-MAXIMUM NON-REPETITIVE
PEAK FORWARD SURGE RATING
MBR20U100CT
20
15
10
5
0
0
25
5 0 100 1 25 150 175 2 00
PEAK FORWARD SURGE CURRENT AMPERES
300
25
CURRENT AMPERES
AVERAGE FORWARD CURRENT RECTIFIED
FIG. 1-FORWARD CURRENT DERATING CURVE
8.3 ms Single Half Sine Wave
250
200
150
100
50
0
AMBIENT TEMPERATURE, oC
1
5
10
50
100
NUMBER OF CYCLES AT 60 Hz
FIG. 4- TYPICAL INSTANTANEOUS
FIG. 3- TYPICAL REVERSE
FORWARD CHARCTERISTICS
10000
Tj=125℃
1000
Tj=100℃
100
Tj=25℃
10
0
20
40
60
PERCENT OF RATED VOLTAGE PEAK
REVERSE VOLTAGE
2015.10
80
100
INSTANTANEOUS FORWARD CURRENT ,AMPERES
INSTANTANEOUS REVERSE CURRENT,MICROAMPERES
CHARACTERISTICS
100
Tj=125℃
10
Tj=25℃
1.0
Pulse Width = 300uS
1% Duty Cycle
0.1
0.1
0.3
0.5
0.7
0.9
1.1 1
.3
1.5
INSTANTANEOUS FORWARD VOLTAGE VOLTS
www.willas.com.tw
Rev.f 02
P2
MBR20U100CT
20A Ultra Low VF Trench MOS Schottky Rectifiers - 100V
Outline Drawing
.413(10.5)
.374(9.5)
.129(3.3)
.1(2.54)
TO-220
.153(3.9) .187(4.82)
.138(3.5) .148(3.8)
.053(1.4)
.043(1.1)
.270(6.9)
.230(5.8)
.624(15.87)
.578(14.7)
.057(1.45)
.046(1.16)
.039(1.00)
.023(0.60)
.157(4.00)
.118(3.00)
.583(14.8)
.499(12.7)
.028(0.7)
.014(0.36)
.102(2.6)
.091(2.3)
.126
(3.20)
Dimensions in inches and (millimeters)
Rev.E-1
2015.10
www.willas.com.tw
Rev.f 02
P3
MBR20U100CT
20A Ultra Low VF Trench MOS Schottky Rectifiers - 100V
Ordering Information:
Device PN
MBR20U100CT - (1)G(2)-WS
Packing
Tube Packing:50pcs/Tube; 1000pcs/Box
Note: 1. Packing code: Empty is Tube Packing
2. RoHS product for packing code suffix ”G”, Halogen free product for packing code suffix "H" .
***Disclaimer***
WILLAS reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. WILLAS or anyone on its behalf assumes no responsibility or liability
for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters
which may be included on WILLAS data sheets and/ or specifications can
and do vary in different applications and actual performance may vary over time.
WILLAS does not assume any liability arising out of the application or
use of any product or circuit.
This is the preliminary specification. WILLAS products are not designed, intended or
authorized for use in medical, life-saving implant or other applications intended for
life-sustaining or other related applications where a failure or malfunction of component
or circuitry may directly or indirectly cause injury or threaten a life without expressed
written approval of WILLAS. Customers using or selling WILLAS components for use in
such applications do so at their own risk and shall agree to fully indemnify WILLAS Inc
and its subsidiaries harmless against all claims, damages and expenditures.
2015.10
www.willas.com.tw
Rev.f 02
P4