BCQ

DC-DC Converter
Bricks, Open/Enclosed
BCQ SERIES, 1/4 BRICK, TWO OUTPUTS, UP TO 65W
FEATURES:
5 year warranty
1500Vdc isolation voltage
Two outputs
Efficiency up to 87%
Operating temperature range -40
Under voltage, over current, short circuit,
℃
to +85
℃
over voltage protection
Remote on/off
Adjustable output voltage
Model
Input voltage
(Vdc)
Vout/Iout 1
(Vdc/A)
Vout/Iout 2
(Vdc/A)
Efficiency
Typ.
3.3/8.0
1.2/8.0
85%
3.3/8.0
1.2/13.0
85%
3.3/8.0
1.5/8.0
85%
3.3/8.0
1.5/12.0
85%
3.3/8.0
1.8/8.0
85%
3.3/8.0
1.8/10.0
85%
3.3/8.0
2.5/8.0
85%
3.3/9.0
2.5/8.0
85%
5.0/3.0
3.3/3.5
85%
5.0/6.0
3.3/7.0
85%
BCQ48-33V8-12V8
BCQ48-33V8-12V13
BCQ48-33V8-15V8
BCQ48-33V8-15V12
BCQ48-33V8-18V8
BCQ48-33V8-18V10
BCQ48-33V8-25V8
BCQ48-33V9-25V8
BCQ48-50V3-33V4
BCQ48-50V6-33V7
48(36~72)
Notes: other input and output models may available on request.
ELECTRICAL
Input voltage range
48Vdc
Remote control
Negative logic
Output power
Input voltage range
30-65W
Input voltage range
±1%
Full load range
±3%
Output voltage accuracy
36-72Vdc
OFF: High level or left close
ON: Low level or grounded
Output voltage adjustable
Positive
Line regulation
Full load
Vo1,vo2 ±0.2%
Load regulation
10%-100% full load
Vo1,vo2 ±0.5%
Dynamic response
(transient/recovery time)
±10%
25%-50%-75% load capability
Ripple and noise
Parallel test, 20MHz wide range
Operating frequency
Typical value
Isolation voltage
Input to output
www.pairuigroup.com
Page:
∆Vo/∆t: ±4.0%/500μs
80mVp-p max.
300KHz typ.
1500Vdc
1/4
Date: 11/07/2015
DC-DC Converter
Bricks, Open/Enclosed
BCQ SERIES, 1/4 BRICK, TWO OUTPUTS, UP TO 65W
ELECTRICAL
Isolation resistance
---
10MΩ
Safety
---
Temperature coefficient
---
Operating temperature range
Auxiliary heat sink
Storage temperature range
---
Over temperature protection
Typical
Under voltage protection
---
Yes
Over current protection
---
Yes
Short circuit protection
---
Yes
Over voltage protection
---
Yes
Relative humidity
---
95% max.
MTBF
Bellcore TR-332, 25
IEC-60950-1, UL-60950-1
EN-60950-1, GB4943
200ppm
℃ to +85℃
-40℃ to +100℃
110℃ typ.
-40
℃
2000KHrs
Notes: All the parameters are measured at 25℃ ambient temperature, humidity < 75%, nominal input voltage,
full load and after warm-up, unless otherwise specified.
MECHANICAL
LOW CURRENT
www.pairuigroup.com
LARGE CURRENT
Page:
2/4
Date: 11/07/2015
DC-DC Converter
Bricks, Open/Enclosed
BCQ SERIES, 1/4 BRICK, TWO OUTPUTS, UP TO 65W
MECHANICAL
CONNECTION
PIN #
DUAL
1
-Vin
2
REM
3
+Vin
4
+Vo2
5
GND
6
TRIM
7
+Vo1
Note:
* Unit is mm(inch).
DERATING CURVE
www.pairuigroup.com
EFFICIENCY CURVE
Page:
3/4
Date: 11/07/2015
DC-DC Converter
Bricks, Open/Enclosed
BCQ SERIES, 1/4 BRICK, TWO OUTPUTS, UP TO 65W
NOTES
RECOMMENDED TEST AND APPLICATION CIRCUIT
1. TVS&FUSE be helpful with over voltage protection and inrush limiting. Recommended FUSE better be 1.5~2times of
the rated current .
2. The input filter capacitor C6 could select the aluminum electrolytic capacitors or tantalum capacitors, and the
withstand voltage should be greater than the highest input voltage. Recommended capacitor should be between
22μF~100μF.
3. C1,C2 for the input filter capacitor,0.1~1μF high-frequency ceramics capacitor or chip capacitor are recommended.
The withstand voltage of output filter C5, C7 should be greater than the highest output voltage. Recommended
capacitor of C7 better within 100μF and C5 connected with the chip to reduce the input voltage peak, recommended
0.1~1μF high-frequency ceramics capacitor or chip capacitor.
www.pairuigroup.com
Page:
4/4
Date: 11/07/2015