INFINEON SFH756

Fiber Optics
Plastic Fiber Optic Transmitter Diode
Plastic Connector Housing
SFH756
SFH756V
Features
• 2.2 mm Aperture holds Standard 1000 Micron
Plastic Fiber
• No Fiber Stripping Required
• Good Linearity (Forward current > 2 mA)
• Molded Microlens for Efficient Coupling
Plastic Connector Housing
• Mounting Screw Attached to the Connector
• Interference Free Transmission from
light-Tight Housing
• Transmitter and Receiver can be flexibly positioned
• No Cross Talk
• Auto insertable and Wave solderable
• Supplied in Tubes
Applications
•
•
•
•
Household Electronics
Power Electronics
Optical Networks
Light Barriers
Type
Ordering Code
SFH756
Q62702-P1716
SFH756V
Q62702-P1715
Data Sheet
1
2004-03-19
SFH756
SFH756V
Technical Data
Technical Data
Absolute Maximum Ratings
Parameter
Symbol
TOP
TSTG
TJ
TS
Operating Temperature Range
Storage Temperature Range
Junction Temperature
Soldering Temperature
(2 mm from case bottom, t ≤ 5 s)
VR
IF
IFSM
PTOT
RthJA
Reverse Voltage
Forward Current
Surge Current (t ≤ 10 µs, D = 0)
Power Dissipation
Thermal Resistance, Junction/Air
Data Sheet
2
Limit Values
Unit
min.
max.
–40
+85
°C
–40
+100
°C
100
°C
260
°C
3
V
50
mA
1
A
120
mW
450
K/W
2004-03-19
SFH756
SFH756V
Technical Data
Characteristics (TA = 25°C)
Parameter
Symbol
Value
Unit
Peak Wavelength
λPeak
660
nm
Spectral Bandwidth
∆λ
25
nm
Switching Times
(RG = 50 Ω), IF(LOW) = 0.1 mA, IF(HIGH) = 50 mA)
10% to 90%
90% to 10%
tR
tF
0.1
0.1
µs
CO
VF
30
pF
Output Power Coupled Into Plastic Fiber
(IF = 10 mA)1)
ΦIN
200
(≥ 100)
µW
Temperature Coefficient ΦIN
TCΦ
TCV
TCλ
–0.4
%/K
–3
mV/K
0.16
nm/K
Capacitance (f = 1 MHz, VR = 0 V)
Forward Voltage (IF = 50 mA)
Temperature Coefficient VF
Temperature Coefficient λPeak
1)
2.1 (≤ 2.8) V
The output power coupled into plastic fiber is measured with a large area detector after a short fiber (about
30 cm). This value must not used for calculating the power budget for a fiber optic system with a long fiber
because the numerical aperture of plastics fibers is decreasing on the first meters. Therefore the fiber seems
to have compared with the specified value a higher attenuation on the first meters.
Data Sheet
3
2004-03-19
SFH756
SFH756V
Technical Data
Relative Spectral Emission Irel = f(λ)
Forward Current IF = f(VF)
single pulse, duration = 20 µs
Relative Output Power Ie/Ie(50 mA) = f(IF)
single pulse, duration = 20 µs
Maximum Permissible Forward Current
IF = f(TA), RthJA = 450 K/W
Data Sheet
4
2004-03-19
SFH756
SFH756V
Technical Data
Permissible Pulse Handling Capability
IF = f(tP), duty cycle D = parameter,
TA = 25°C
Data Sheet
5
2004-03-19
SFH756
SFH756V
Package Outlines
Package Outlines
SFH756
Dimensions in mm
File: 4209
Figure 1
SFH756V
Dimensions in mm
File: 4210
Figure 2
Data Sheet
6
2004-03-19
SFH756
SFH756V
Revision History:
2004-03-19
Previous Version:
2002-03-14
DS1
Edition 2004-03-19
Published by Infineon Technologies AG,
St.-Martin-Strasse 53,
81669 München, Germany
© Infineon Technologies AG 2004.
All Rights Reserved.
Attention please!
The information herein is given to describe certain components and shall not be considered as a guarantee of
characteristics.
Terms of delivery and rights to technical change reserved.
We hereby disclaim any and all warranties, including but not limited to warranties of non-infringement, regarding
circuits, descriptions and charts stated herein.
Information
For further information on technology, delivery terms and conditions and prices please contact your nearest
Infineon Technologies Office (www.infineon.com).
Warnings
Due to technical requirements components may contain dangerous substances. For information on the types in
question please contact your nearest Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or systems with the express written
approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure
of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support
devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain
and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may
be endangered.