LB1909MCGEVB_TEST_PROCEDURE.PDF - 151 KB

Test Procedure for the LB1909MCGEVB Evaluation Board
For stepper motor control
CURRENT PROBE
AMPLIFIER1
Osclloscope
PROBE
INPUT
OUTPUT
CHANNEL
1
2
3
4
Stepping Motor
Power supply 1
A
V
-
+
Logic generator
Power supply 2
A
V
CHANNEL
1
-
2
3
4
+
Table1: Required Equipment
Equipment
Efficiency
25V-3A
10V-0.5A
200kHz
4 channel
25V-2A
Power supply1
Power supply2
Logic generator
Oscilloscope
Current probe1
LB1909MC Evaluation Board
Stepper Motor
1/8/2014
1
www.onsemi.com
Test Procedure:
1. Connect the test setup as shown above.
2. Set it according to the following guide.
[Supply Voltage]
VCC (2.5 to 16V) : Power Supply for LSI
VIN (1.8 to 10V) : Logic “High” voltage for toggle switch
[Toggle Switch State] Upper Side: High (VIN)
Middle: Open, enable to external logic input
Lower Side: Low (GND)
[Operation Guide]
1. Initial Condition Setting: Set “Open” the toggle switches ENA , IN1 and IN2.
2. Power Supply: Supply DC voltage to VCC and VIN.
3. Ready for Operation from Standby State: Turn “High” the ENA terminal toggle switch.
4. Motor Operation: Input the signal which is in condition to want to operate into IN1 and
IN2.
3. Check the IN1 , IN2 and OUT1 terminal voltage at scope CH1 , CH2 and CH3, and the output
current waveform at scope CH4.
Table2: Desired Results
INPUT
OUTPUT
VCC=12V
VIN=5V
* Refer to the following waveform
ENA=H
IN1 , IN2=Full-step signal
Typical current waveform
LB1909MC Full-Step(VCC=12V, 200pps)
High
IN1
Low
Low
High
IN2
High
Low
(%)
100
I1
Ch2
IN2
10V/div
Ch3
VOUT1
10V/div
0
Ch4
IOUT1
200mA/div
-100
100
I2
Ch1
IN1
10V/div
0
T=5ms/div
-100
1/8/2014
2
www.onsemi.com