LV8771VHGEVB_TEST_PROCEDURE.PDF - 149 KB

Test Procedure for the LV8771 Evaluation Board
Data generator
Data waveform
Output
5
6
4
2
3
Power supply 3
1
V
Power supply 2
V
A
A
+
-
-
+
Power supply 1
V
A
Multimeter
+
-
VOUT
OUT1A
OUT2A
OUT1B
+
OUT2B
-
Stepping Motor
Osclloscope
CURRENT PROBE
AMPLIFIER 1
PROBE
INPUT
OUTPUT
CHANNEL
1
2
3
4
Table3: Required Equipment
Equipment
Power supply1
Power supply2
Power supply3
Data generator
multimeter
Oscilloscope
Current probe
LV8771VH Evaluation Board
Stepper Motor
1/8/2014
Efficiency
35V-5A
5V-0.5A
10V-1A
4 channel
35V-3A
1
www.onsemi.com
Test Procedure:
1. Connect the test setup as shown above.
2. Set it according to the following guide.
[Supply Voltage]
VM (9 to 32V): Power Supply for LSI
VREF (0 to 3V): Const. Current Control for Reference Voltage
VDD (2 to 5V): Logic “High” voltage for toggle switch
[Toggle Switch State] Upper Side: High (VDD)
Middle: Open, enable to external logic input
Lower Side: Low (GND)
[Operation Guide]
1. Initial Condition Setting: Set “Open or Low” all switches.
2. Motor Connection: Connect the Motors between OUT1A and OUT1B, between OUT2A
and OUT2B.
3. Power Supply: Supply DC voltage to VM, VREF and VDD.
4. Ready for Operation from Standby State: Turn “High” the ST toggle switch.
5. Motor Operation: Set I01, I02, PH1, I02, I12 and PH2 terminals according to the
purpose.
3. Check VREG5 and VG terminal voltage at multimeter.
4. Check the I01, I11 and PH1; terminal voltage at scope CH1, CH2 and CH3, and the output current
waveform at scope CH4.
5. Switch to channel 2(I02, I12, PH2) as well as channel 1(I01, I11, PH1) and measure it.
Table4: Desired Results
INPUT
VM=24V, VDD=5V, VREF=1.5V
ST=H, FC=L
1/8/2014
OUTPUT
VREG5=4.7V to 5.3V
VG=28V to 29.8V
2
www.onsemi.com