Test Procedure for MC34063 Buck Regulator (Leaded) Demonstration Board
h
11/11/2003
Three Black Test Leads
12 VDC Power Supply
Four Alligator Clips
Table 1: Required Equipment
Three Red Test Leads
100mA load (or 33 ohm, 1W resistor)
MC34063 Buck Regulator
Digital Multimeter
Figure 1: Test Procedure for MC34063
1.
2.
3.
4.
5.
6.
7.
8.
9.
Attach 100mA load (or 33 ohm, 1W resistor) to connector P502.
Attach 12 VDC source to connector P501 – observe polarity.
Turn on 12 VDC source.
Measure DC output voltage at connector P502.
DC voltage should be 3.3 V +/- 0.15 V.
Remove load.
Measure DC output voltage at connector P502.
DC voltage should be 3.3 V +/- 0.15 V.